Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “turning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Hohlraum used as a single turn solenoid to generate seed magnetic field for inertial confinement fusion

Application of axial seed magnetic fields in the range 20-100 T that compress to greater than 10,000 T (100 MG) under typical NIF implosion conditions may significantly relax the conditions required for ignition and propagating burn in NIF ignition targets that are degraded by hydrodynamic instabilities. Such magnetic fields can: (a) permit the recovery of ignition, or at least significant alpha particle heating, in submarginal NIF targets that would otherwise fail because of adverse hydrodynamic instability growth, (b) permit the attainment of ignition in conventional cryogenic layered solid-DT targets redesigned to operate under reduced drive conditions, (c) permit the attainment of volumetric ignition in simpler, room-temperature single-shell DT gas capsules, and (d) ameliorate adverse hohlraum plasma conditions during laser drive and capsule compression. In general, an applied magnetic field should always improve the ignition condition for any NIF ignition target design.

Perkins, Lindsay John↗

New coal dewatering technology turns sludge to powder

Virginian Tech's College of Engineering's Roe-Hoan Yoon and his group have developed a hyperbaric centrifuge that can dewater coal as fine as talcum powder. Such coal fines presently must be discarded by even the most advanced coal cleaning plants because of their high moisture content. The new technology can be used with the Microcel technology to remove ash, to re-mine the fine coal discarded to impoundments and to help minimize waste generation. Virginia Tech has received $1 million in funding from the US Department of State to also help the Indian coal industry produce a cleaner product. 1 photo.

01 COAL, LIGNITE, AND PEAT↗

Maximizing Operational Efficiencies in Waste Management on the Hanford Plateau Remediation Contract in a Down-turned Market - 13484

Recent changes in DOE priorities and funding have pressed DOE and its contractors to look for innovative methods to sustain critical operations at sites across the Complex. At the Hanford Site, DOE Richland Operations and its prime contractor, CH2M Hill Plateau Remediation Company (CHPRC), have completed in-depth assessments of the Plateau Remediation Contract (PRC) operations that compared available funding to mission and operational objectives in an effort to maintain requisite safety and compliance margins while realizing cost savings that meet funding profiles. These assessments included confirmation of current baseline activities, identification of potential efficiencies, barriers to implementation, and potential increased risks associated with implementation. Six operating PRC waste management facilities were evaluated against three possible end-states: complete facility closure, maintaining base operations, and performing minimum safe surveillance and maintenance activities. The costs to completely close evaluated facilities were determined to be prohibitively high and this end-state was quickly dropped from consideration. A summary of the analysis of remaining options by facility, efficiencies identified, impact to risk profiles, and expected cost savings is provided in Table I. The expected cost savings are a result of: - right-sizing and cross-training work crews to address maintenance activities across facilities; - combining and sequencing 'like-moded' operational processes; - cross-cutting emergency planning and preparedness staffing; - resource redistribution and optimization; - reducing areas requiring routine surveillance and inspection. For the efficiencies identified, there are corresponding increases in risk, including a loss of breadth and depth of available resources; lengthened response time to emergent issues; inability to invest in opportunities for improvement (OFIs); potential single-point failures or non-compliancies due to resource scarcity; limited cross-training capability; and reduced capability to respond to changes in DOE priorities. Finally, there are many challenges to achieving these cost savings. With a workforce nearing retirement effective succession planning becomes critical to success and requires establishing a balance between the cost of hiring and training and cost-saving activities. With six active waste management facilities spread across nearly 15 square miles, scheduling and deploying cross-trained surveillance and maintenance teams is a logistical challenge, particularly as the loss of funding has not diminished emphasis by regulatory agencies placed on the safe and compliant performance of DOE and its contractors. As reflected in Table I, efficiencies are currently being implemented on the Hanford Plateau Remediation Contract (PRC) that deliver cost savings that align with the current site budget while maintaining critical capabilities. It is currently estimated that these efficiencies will result in a cost savings of approximately $9 million for FY13 in base and minimum safe operations on the PRC - a cost reduction of more than 13 percent over FY12 and nearly 30 percent over FY09 levels. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hohlraum used as a single turn solenoid to generate seed magnetic field for inertial confinement fusion

Application of axial seed magnetic fields in the range 20-100 T that compress to greater than 10,000 T (100 MG) under typical NIF implosion conditions may significantly relax the conditions required for ignition and propagating burn in NIF ignition targets that are degraded by hydrodynamic instabilities. Such magnetic fields can: (a) permit the recovery of ignition, or at least significant alpha particle heating, in submarginal NIF targets that would otherwise fail because of adverse hydrodynamic instability growth, (b) permit the attainment of ignition in conventional cryogenic layered solid-DT targets redesigned to operate under reduced drive conditions, (c) permit the attainment of volumetric ignition in simpler, room-temperature single-shell DT gas capsules, and (d) ameliorate adverse hohlraum plasma conditions during laser drive and capsule compression. In general, an applied magnetic field should always improve the ignition condition for any NIF ignition target design.

Perkins, Lindsay John↗

Turning a liability into an asset: creating liquid transportation fuels from CO2, natural gas, or RNG

GTI will be discussing our Cool GTL process, a new low cost versatile integrated modular process which can convert CO2, methane, ethane, and biogas, to gasoline jet and diesel with no wax intermediate product. We have tested Cool GTL at small scale and are beginning tests at larger 2 gallon/day scale for biogas conversion ( with DOE funding). Our ultimate goal is to have several commercial deployments of Cool GTL in a variety of applications running in 5 years. Most exciting is the fact that Cool GTL can totally eliminate Global Warming and produce all the worlds transportation fuel by conversion of the excess CO2 currently in the air to liquid transportation fuels, leading to a modern revolution in the way transportation fuels are produced.

09 BIOMASS FUELS↗

Combining CO2 Electrolysis with Biological Upgrading to Fuels and Chemicals: Turning Waste into Fuels

The utilization of flue gas-derived CO2 presents an opportunity to enhance carbon utilization in the bioethanol industry, contributing to the production of valuable products. In the context of a 90 million-gallon-per-year corn ethanol plant generating approximately 30 tons per hour of 99% pure CO2, a collaborative effort involving six national laboratories has been established. This initiative, known as the CO2 Reduction and Upgrading for e-Fuels (CO2RUe) Consortium, is funded by the Department of Energy's BioEnergy Technologies Office (BETO). The primary objective of the CO2RUe Consortium is to explore innovative approaches to harness CO2 as a valuable feedstock. This interdisciplinary consortium integrates electrochemistry with biological upgrading techniques, aiming to yield sustainable, value-added products and aviation fuels. The presentation will delve into the recent advancements in the realms of electrochemistry and biological upgrading, with a specific focus on formic acid and CO. Additionally, the talk will include an analysis of future electricity grid scenarios, technoeconomic evaluations, and life-cycle assessments. These assessments aim to provide a comprehensive understanding of the impacts of various conversion pathways on both cost and carbon intensity. The CO2RUe Consortium is at the forefront of steering the development of economically favorable and sustainable processes for CO2 utilization. The presentation will showcase the consortium's progress in driving the advancement of technology and processes, emphasizing the economic viability and sustainability of CO2 utilization within the broader context of the bioethanol industry.

biological upgrading↗

Demonstration of a multi-channel, low-profile wire gauge for tracing wave development and detonation turning in explosives

The multi-channel low-profile wire gauge is a device which measures high pressure wave position via the continuous variation in length of a conductor in conjunction with a fiducial, allowing in situ measurement of wave front curvature during wave development. The gauge's low profile ({approx}250 {micro}m) and high resolution measurements (up to 0.5 nanoseconds) make it minimally intrusive and highly responsive, with a typically wave position accuracy of {+-}1 mm. Gauge construction and data analysis methods are described and waveforms are presented for Detasheet and N-9 explosives.

47 OTHER INSTRUMENTATION↗

Ultrafast Power Processor for Smart Grid: Power Module Development

This project’s goal was to increase the switching speed and decrease the losses of the power semiconductor devices and power switch modules necessary to enable Smart Grid energy flow and control equipment such as the Ultra-Fast Power Processor. The primary focus of this project involves exploiting the new silicon-based Super-GTO (SGTO) technology and build on prototype modules already being developed. The prototype super gate-turn-off thyristor (SGTO) has been tested fully under continuously conducting and double-pulse hard-switching conditions for conduction and switching characteristics evaluation. The conduction voltage drop measurement results indicate that SGTO has excellent conduction characteristics despite inconsistency among some prototype devices. Tests were conducted with two conditions: (1) fixed gate voltage and varying anode current condition, and (2) fixed anode current and varying gate voltage condition. The conduction voltage drop is relatively a constant under different gate voltage condition. In terms of voltage drop as a function of the load current, there is a fixed voltage drop about 0.5V under zero current condition, and then the voltage drop is linearly increased with the current. For a 5-kV voltage blocking device that may operate under 2.5-kV condition, the projected voltage drop is less than 2.5 V under 50-A condition, or 0.1%. If the device is adopted in a converter operating under soft-switching condition, then the converter can achieve an ultrahigh efficiency, typically above 99%. The two-pulse switching test results indicate that SGTO switching speed is very fast. The switching loss is relatively low as compared to that of the insulated-gate-bipolar-transistors (IGBTs). A special phenomenon needs to be noted is such a fast switching speed for the high-voltage switching tends to create an unexpected Cdv/dt current, which reduces the turn-on loss because the dv/dt is negative and increases the turn-off loss because the dv/dt is positive. As a result, the turn-on loss at low current is quite low, and the turn-off loss at low current is relatively high. The phenomenon was verified with junction capacitance measurement along with the dv/dt calculation. Under 2-kV test condition, the turn-on and turn-off losses at 25-A is about 3 and 9 mJ, respectively. As compared to a 4.5-kV, 60-A rated IGBT, which has turn-on and turn-off losses about 25 and 20 mJ under similar test condition, the SGTO shows significant switching loss reduction. The switching loss depends on the switching frequency, but under hard-switching condition, the SGTO is favored to the IGBT device. The only concern is during low current turn-on condition, there is a voltage bump that can translate to significant power loss and associated heat. The reason for such a current bump is not known from this study. It is necessary that the device manufacturer perform though test and provide the answer so the user can properly apply SGTO in pulse-width-modulated (PWM) converter and inverter applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Discrete modeling of a transformer with ALEGRA

We report progress on a task to model transformers in ALEGRA using the “Transient Magnetics” option. We specifically evaluate limits of the approach resolving individual coil wires. There are practical limits to the number of turns in a coil that can be numerically modeled, but calculated inductance can be scaled to the correct number of turns in a simple way. Our testing essentially confirmed this “turns scaling” hypothesis. We developed a conceptual transformer design, representative of practical designs of interest, and that focused our analysis. That design includes three coils wrapped around a rectangular ferromagnetic core. The secondary and tertiary coils have multiple layers. The tertiary has three layers of 13 turns each; the secondary has five layers of 44 turns; the primary has one layer of 20 turns. We validated the turns scaling of inductance for simple (one-layer) coils in air (no core) by comparison to available independent calculations for simple rectangular coils. These comparisons quantified the errors versus reduced number of turns modeled. For more than 3 turns, the errors are <5%. The magnetic field solver failed to converge (within 5000 iterations) for >10 turns. Including the core introduced some complications. It was necessary to capture the core surfaces in thin grid sheaths to minimize errors in computed magnetic energy. We do not yet have quantitative benchmarks with which to compare, but calculated results are qualitatively reasonable.

42 ENGINEERING↗