Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “time resolution data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Performance of the ATLAS RPC detector and Level-1 muon barrel trigger at √(s)=13 TeV

The ATLAS experiment at the Large Hadron Collider (LHC) employs a trigger system consisting of a first-level hardware trigger (L1) and a software-based high-level trigger. The L1 muon trigger system selects muon candidates, assigns them to the correct LHC bunch crossing and classifies them into one of six transverse-momentum threshold classes. The L1 muon trigger system uses resistive-plate chambers (RPCs) to generate the muon-induced trigger signals in the central (barrel) region of the ATLAS detector. The ATLAS RPCs are arranged in six concentric layers and operate in a toroidal magnetic field with a bending power of 1.5 to 5.5 Tm. The RPC detector consists of about 3700 gas volumes with a total surface area of more than 4000 m2. This paper reports on the performance of the RPC detector and L1 muon barrel trigger using 60.8 fb-1 of proton-proton collision data recorded by the ATLAS experiment in 2018 at a centre-of-mass energy of 13 TeV. Detector and trigger performance are studied using Z boson decays into a muon pair. Measurements of the RPC detector response, efficiency, and time resolution are reported. Measurements of the L1 muon barrel trigger efficiencies and rates are presented, along with measurements of the properties of the selected sample of muon candidates. Measurements of the RPC currents, counting rates and mean avalanche charge are performed using zero-bias collisions. Finally, RPC detector response and efficiency are studied at different high voltage and front-end discriminator threshold settings in order to extrapolate detector response to the higher luminosity expected for the High Luminosity LHC.

47 OTHER INSTRUMENTATION↗

Scintillation light detection performance for the DUNE ND-LAr 2 × 2 modules

The Deep Underground Neutrino Experiment (DUNE) will be using a liquid argon time projection chamber (LAr TPC) with optically separated modules in the Near Detector (ND) complex. A prototype experiment, DUNE ND-LAr 2 × 2, is composed of four test modules. They detect ionization charge through a pixel-based readout and scintillation light through fibers in light collection modules and light traps called ArCLights. The light detection performance for two modules of DUNE ND-LAr 2 × 2 that took cosmic ray data at the University of Bern is shown. We present further the role of the 2 × 2 prototype in DUNE and how it is used to demonstrate the reconstruction capabilities of its light detectors in terms of energy thresholds and timing resolution.

47 OTHER INSTRUMENTATION↗

Light-Level Geolocation of the LANL Population of Western Bluebirds

Options for tracking and reconstructing animal movement are increasingly accessible due to rapidly decreasing costs, smaller sizes, and a proliferation of analytical inference techniques (Rutz and Hays, 2009; Wikelski et al., 2007). A wide variety of options exists for determining movement patterns of animals—from high-resolution pinpoint ARGOS satellite tags to time-consuming and logistically challenging radio telemetry. One option, light-level geolocation, offers small, affordable devices with long battery lives known as global location sensors (GLS), making them ideal for gathering preliminary migratory data. Geolocation works by inferring patterns of animal movement from light-level transitions between day and night (Hill and Braun, 2001). The recent advances in tracking technologies allow biologists to zoom in on migratory behavior, delineating heretofore-unidentified intraspecific migratory behavior (Delmore et al., 2012). The ubiquity of migratory divides (populations within a species that exhibit different migratory patterns) remains largely unknown, but their existence can lead to favorable demographic metrics (e.g., genetic diversity) in conservation contexts (Møller et al., 2011) and necessitate the development of population-specific conservation plans (Delmore et al., 2012). Delimiting the populations within a species that migrate and the extent of their migrations relative to individuals that remain resident across a species’ range has important evolutionary, ecological, and conservation implications. Within this context, Los Alamos National Laboratory (LANL) biologists have leveraged the local Avian Nestbox Network (ANN; Fair and Myers, 2002) to evaluate the migratory behaviors of a common local bird species, the Western Bluebird (Sialia mexicana).

47 OTHER INSTRUMENTATION↗

2021 GeoAI Workshop Report: The Trillion Pixel Challenge

The convergence of geospatial big data with advancements from artificial intelligence, cloud infrastructure, and high-performance computing continues to revolutionize mapping and analysis of Earth's surface in unprecedented detail. Rapid innovations in sensing technologies will soon collect geospatial data in even higher resolution and throughput. These developments offer the potential for breakthroughs in science, policy, and national security via end-to-end GeoAI systems that can provide fresh insights into how humans occupy and alter their environment over time. At the 2021 GeoAI Trillion Pixel workshop, international subject matter experts from government, academia, industry, and nonprofit organizations gathered virtually to discuss the Trillion Pixel GeoAI Challenge. The event focused on six major themes currently influencing scientific innovation and breakthroughs. Particular focus was paid to societal impacts. As an additional takeaway message, the gathering identified remaining application gaps and challenges that are in need of stronger community partnerships and collaborations.

58 GEOSCIENCES↗

Improving the representation of shallow cumulus convection with the simplified-higher-order-closure–mass-flux (SHOC+MF v1.0) approach

Abstract. Parameterized boundary layer turbulence and moist convection remain some of the largest sources of uncertainty in general circulation models. High-resolution climate modeling aims to reduce that uncertainty by explicitly attempting to resolve deep moist convective motions. An example of such a model is the Simple Cloud-Resolving E3SM Atmosphere Model (SCREAM) with a target global resolution of 3.25 km, allowing for a more accurate representation of complex mesoscale deep convective dynamics. Yet, small-scale planetary boundary layer turbulence and shallow convection still need to be parameterized, which in SCREAM is accomplished through the turbulent-kinetic-energy-based (TKE-based) simplified higher-order closure (SHOC) – a simplified version of the assumed-double-Gaussian-PDF (probability density function) higher-order-closure method. In this paper, we implement a stochastic-multiplume mass-flux (MF) parameterization of dry and shallow convection in SCREAM to go beyond the limitations of double-Gaussian-PDF closures and couple it to SHOC (SHOC+MF). The new parameterization implemented in a single-column model type version of SCREAM produces results for two shallow cumulus convection cases (marine and continental shallow convection) that agree well with the reference data from large-eddy simulations, thus improving the general representation of the thermodynamic quantities and their turbulent fluxes as well as cloud macrophysics in the model. Furthermore, SHOC+MF parameterization shows weak sensitivity to the vertical grid resolution and model time step.

54 ENVIRONMENTAL SCIENCES↗

Scintillation light detection performance for the DUNE ND-LAr 2 × 2 modules

The Deep Underground Neutrino Experiment (DUNE) will be using a liquid argon time projection chamber (LAr TPC) with optically separated modules in the Near Detector (ND) complex. A prototype experiment, DUNE ND-LAr 2 × 2, is composed of four test modules. They detect ionization charge through a pixel-based readout and scintillation light through fibers in light collection modules and light traps called ArCLights. The light detection performance for two modules of DUNE ND-LAr 2 × 2 that took cosmic ray data at the University of Bern is shown. We present further the role of the 2 × 2 prototype in DUNE and how it is used to demonstrate the reconstruction capabilities of its light detectors in terms of energy thresholds and timing resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

BeyondPlanck: I. Global Bayesian analysis of the Planck Low Frequency Instrument data

We describe the BEYONDPLANCK project in terms of our motivation, methodology, and main products, and provide a guide to a set of companion papers that describe each result in more detail. Building directly on experience from ESA’s Planck mission, we implemented a complete end-to-end Bayesian analysis framework for the Planck Low Frequency Instrument (LFI) observations. The primary product is a full joint posterior distribution P(ω | d), where ω represents the set of all free instrumental (gain, correlated noise, bandpass, etc.), astrophysical (synchrotron, free-free, thermal dust emission, etc.), and cosmological (cosmic microwave background – CMB – map, power spectrum, etc.) parameters. Some notable advantages of this approach compared to a traditional pipeline procedure are seamless end-to-end propagation of uncertainties; accurate modeling of both astrophysical and instrumental effects in the most natural basis for each uncertain quantity; optimized computational costs with little or no need for intermediate human interaction between various analysis steps; and a complete overview of the entire analysis process within one single framework. As a practical demonstration of this framework, we focus in particular on low-ℓ CMB polarization reconstruction with Planck LFI. In this process, we identify several important new effects that have not been accounted for in previous pipelines, including gain over-smoothing and time-variable and non-1/f correlated noise in the 30 and 44 GHz channels. Modeling and mitigating both previously known and newly discovered systematic effects, we find that all results are consistent with the ΛCDM model, and we constrained the reionization optical depth to τ = 0.066 ± 0.013, with a low-resolution CMB-based χ 2 probability to exceed of 32%. This uncertainty is about 30% larger than the official pipelines, arising from taking a more complete instrumental model into account. The marginal CMB solar dipole amplitude is 3362.7 ± 1.4 μK, where the error bar was derived directly from the posterior distribution without the need of any ad hoc instrumental corrections. We are currently not aware of any significant unmodeled systematic effects remaining in the Planck LFI data, and, for the first time, the 44 GHz channel is fully exploited in the current analysis. We argue that this framework can play a central role in the analysis of many current and future high-sensitivity CMB experiments, including LiteBIRD, and it will serve as the computational foundation of the emerging community-wide COSMOGLOBE effort, which aims to combine state-of-the-art radio, microwave, and submillimeter data sets into one global astrophysical model.

79 ASTRONOMY AND ASTROPHYSICS↗

A time-resolved imaging system for the diagnosis of x-ray self-emission in high energy density physics experiments

A diagnostic capable of recording spatially and temporally resolved x-ray self-emission data was developed to characterize experiments on the MAGPIE pulsed-power generator. The diagnostic used two separate imaging systems: a pinhole imaging system with two-dimensional spatial resolution and a slit imaging system with one-dimensional spatial resolution. The two-dimensional imaging system imaged light onto the image plate. The one-dimensional imaging system imaged light onto the same piece of image plate and a linear array of silicon photodiodes. This design allowed the cross-comparison of different images, allowing a picture of the spatial and temporal distribution of x-ray self-emission to be established. The design was tested in a series of pulsed-power-driven magnetic-reconnection experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling Global Vegetation Gross Primary Productivity, Transpiration and Hyperspectral Canopy Radiative Transfer Simultaneously Using a Next Generation Land Surface Model—CliMA Land

Recent progress in satellite observations has provided unprecedented opportunities to monitor vegetation activity at global scale. However, a major challenge in fully utilizing remotely sensed data to constrain land surface models (LSMs) lies in inconsistencies between simulated and observed quantities. For example, gross primary productivity (GPP) and transpiration (T) that traditional LSMs simulate are not directly measurable from space, although they can be inferred from spaceborne observations using assumptions that are inconsistent with those LSMs. In comparison, canopy reflectance and fluorescence spectra that satellites can detect are not modeled by traditional LSMs. To bridge these quantities, we presented an overview of the next generation land model developed within the Climate Modeling Alliance (CliMA), and simulated global GPP, T, and hyperspectral canopy radiative transfer (RT; 400–2,500 nm for reflectance, 640–850 nm for fluorescence) at hourly time step and 1° spatial resolution using CliMA Land. CliMA Land predicts vegetation indices and outgoing radiances, including solar-induced chlorophyll fluorescence (SIF), normalized difference vegetation index (NDVI), enhanced vegetation index (EVI), and near infrared reflectance of vegetation (NIRv) for any given sun-sensor geometry. The spatial patterns of modeled GPP, T, SIF, NDVI, EVI, and NIRv correlate significantly with existing data-driven products (mean R 2 = 0.777 for 9 products). CliMA Land would be also useful in high temporal resolution simulations, for example, providing insights into when GPP, SIF, and NIRv diverge.

54 ENVIRONMENTAL SCIENCES↗

Converting dark matter to dark radiation does not solve cosmological tensions

Tensions between cosmological parameters (in particular the local expansion rate H 0 and the amplitude of matter clustering S8) inferred from low-redshift data and data from the cosmic microwave background (CMB) and large-scale structure (LSS) experiments have inspired many extensions to the standard cosmological model, LCDM. Models which simultaneously lessen both tensions are of particular interest. We consider one scenario with the potential for such a resolution, in which some fraction of the dark matter has converted into dark radiation since the release of the CMB. Such a scenario encompasses and generalizes the more standard "decaying dark matter" model, allowing additional flexibility in the rate and time at which the dark matter converts into dark radiation. In this paper, we constrain this scenario with a focus on exploring whether it can solve (or reduce) these tensions. We find that such a model is effectively ruled out by CMB data, in particular by the reduced peak-smearing due to CMB lensing on the power spectrum and the excess integrated Sachs--Wolfe (ISW) signal caused by the additional dark energy density required to preserve flatness after dark matter conversion into dark radiation. Thus, such a model does not have the power to reduce these tensions without further modifications. This conclusion extends and generalizes related conclusions derived for the standard decaying dark matter model.

79 ASTRONOMY AND ASTROPHYSICS↗

Tracking seasonal variability in plant traits from spaceborne PRISMA and NEON AOP across forest types and ecoregions

Plant traits serve as critical indicators of how plants adapt to environmental changes and influence ecosystem functions. While airborne hyperspectral remote sensing effectively maps plant traits through detailed reflectance properties, it is limited by cost and scale, making large-scale and temporal studies challenging. The recently launched spaceborne hyperspectral imager, PRecursore IperSpettrale della Missione Applicativa (PRISMA), offers frequent, large scale and high-fidelity observations on a spatial resolution of 30 m and a revisit time of around 29 days, making it suitable for large-scale seasonal trait mapping. However, their potential remains largely unexplored. This study developed a multi-stage framework by leveraging the PRISMA spaceborne hyperspectral data and National Ecological Observatory Network (NEON) Airborne Observation Platform (AOP) hyperspectral data to investigate the seasonal dynamics of four key plant traits — chlorophyll content, carotenoid content, equivalent water thickness, and nitrogen content — across eleven NEON sites representing diverse forest types and ecoregions in the contiguous U.S. Our results demonstrated that PRISMA hyperspectral data can reliably track seasonal variability in plant traits, achieving overall R 2 values ranging from 0.78 to 0.88 and normalized root mean square error (NRMSE) values ranging from 5.4% to 8.4% for the four traits. Seasonal patterns revealed bell-shaped trajectories for chlorophyll and carotenoids, while equivalent water thickness decreased steadily across most sites, driven by structural changes during leaf maturation and senescence. Nitrogen content exhibited less pronounced seasonal variation but followed expected nutrient resorption patterns. Analysis of environmental drivers showed that seasonal variability is primarily controlled by solar radiation and day length in northern sites, vapor pressure in semi-arid regions, and temperature in mid-southeastern sites. Spatial variability, meanwhile, was primarily driven by soil properties, particularly during the peak growing season. However, the influence of soil variables slightly declines toward the end of the season at several sites, as climatic factors become more prominent. This study highlights the capability of PRISMA, and potentially other similar spaceborne hyperspectral data for large-scale, time-series plant trait mapping and provides valuable insights into the interactions between plant traits and environmental factors. In conclusion, these findings contribute to advancing our understanding of plant functional ecology and improving predictions of ecosystem responses to environmental changes.

Environmental drivers↗

Development of Lipid-Coated Semiconductor Nanosensors for Recording of Membrane Potential in Neurons

In the past decade, optical imaging methods have significantly improved our understanding of the information processing principles in the brain. Although many promising tools have been designed, sensors of membrane potential are lagging behind the rest. Semiconductor nanoparticles are an attractive alternative to classical voltage indicators, such as voltage-sensitive dyes and proteins. Such nanoparticles exhibit high sensitivity to external electric fields via the quantum-confine Stark effect. Here we report the development of semiconductor voltage-sensitive nanorods (vsNRs) that self-insert into the neuronal membrane. To facilitate interaction of the nanorods with the membrane, we functionalized their surface with the lipid mixture derived from brain extract. We describe a workflow to detect and process the photoluminescent signal of vsNRs after widefield time-lapse recordings. We also present data indicating that vsNRs are feasible for sensing membrane potential in neurons at a single-particle level. This shows the potential of vsNRs for the detection of neuronal activity with unprecedentedly high spatial and temporal resolution.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Heterogeneity in M. tuberculosis β-lactamase inhibition by Sulbactam

Abstract For decades, researchers have elucidated essential enzymatic functions on the atomic length scale by tracing atomic positions in real-time. Our work builds on possibilities unleashed by mix-and-inject serial crystallography (MISC) at X-ray free electron laser facilities. In this approach, enzymatic reactions are triggered by mixing substrate or ligand solutions with enzyme microcrystals. Here, we report in atomic detail (between 2.2 and 2.7 Å resolution) by room-temperature, time-resolved crystallography with millisecond time-resolution (with timepoints between 3 ms and 700 ms) how the Mycobacterium tuberculosis enzyme BlaC is inhibited by sulbactam (SUB). Our results reveal ligand binding heterogeneity, ligand gating, cooperativity, induced fit, and conformational selection all from the same set of MISC data, detailing how SUB approaches the catalytic clefts and binds to the enzyme noncovalently before reacting to a trans- enamine. This was made possible in part by the application of singular value decomposition to the MISC data using a program that remains functional even if unit cell parameters change up to 3 Å during the reaction.

74 ATOMIC AND MOLECULAR PHYSICS↗

Serial femtosecond and serial synchrotron crystallography can yield data of equivalent quality: A systematic comparison

For the two proteins myoglobin and fluoroacetate dehalogenase, we present a systematic comparison of crystallographic diffraction data collected by serial femtosecond (SFX) and serial synchrotron crystallography (SSX). To maximize comparability, we used the same batch of micron-sized crystals, the same sample delivery device, and the same data analysis software. Overall figures of merit indicate that the data of both radiation sources are of equivalent quality. For both proteins, reasonable data statistics can be obtained with approximately 5000 room-temperature diffraction images irrespective of the radiation source. The direct comparability of SSX and SFX data indicates that the quality of diffraction data obtained from these samples is linked to the properties of the crystals rather than to the radiation source. Therefore, for other systems with similar properties, time-resolved experiments can be conducted at the radiation source that best matches the desired time resolution.

59 BASIC BIOLOGICAL SCIENCES↗

LLNL FY22 Aging and Lifetimes Exit Criteria (Milestone 8118, GC#5)

This report introduces a novel characterization tool that can rapidly collect in-situ time-dependent oxide thickness and hydride growth data together with spatial data using while-light interferometry. White-light interferometry is a non-destructive and non-contact optical surface profiling technique for materials characterization that offers excellent lateral and vertical resolution. A depleted uranium sample was used to assess the ability of white-light interferometry to provide quantitative corrosion reaction rates at metal surfaces for by hydriding and oxidation and compare this technique to existing characterization tools for capturing early-stage hydride and oxide growth kinetics.

36 MATERIALS SCIENCE↗

Assessing Heterogeneity of Surface Water Temperature Following Stream Restoration and a High-Intensity Fire from Thermal Imagery

Thermal heterogeneity of rivers is essential to support freshwater biodiversity. Salmon behaviorally thermoregulate by moving from patches of warm water to cold water. When implementing river restoration projects, it is essential to monitor changes in temperature and thermal heterogeneity through time to assess the impacts to a river’s thermal regime. Lightweight sensors that record both thermal infrared (TIR) and multispectral data carried via unoccupied aircraft systems (UASs) present an opportunity to monitor temperature variations at high spatial (<0.5 m) and temporal resolution, facilitating the detection of the small patches of varying temperatures salmon require. Here, we present methods to classify and filter visible wetted area, including a novel procedure to measure canopy cover, and extract and correct radiant surface water temperature to evaluate changes in the variability of stream temperature pre- and post-restoration followed by a high-intensity fire in a section of the river corridor of the South Fork McKenzie River, Oregon. We used a simple linear model to correct the TIR data by imaging a water bath where the temperature increased from 9.5 to 33.4 °C. The resulting model reduced the mean absolute error from 1.62 to 0.35 °C. We applied this correction to TIR-measured temperatures of wetted cells classified using NDWI imagery acquired in the field. We found warmer conditions (+2.6 °C) after restoration (p < 0.001) and median absolute deviation for pre-restoration (0.30) to be less than both that of post-restoration (0.85) and post-fire (0.79) orthomosaics. In addition, there was statistically significant evidence to support the hypothesis of shifts in temperature distributions pre- and post-restoration (KS test 2009 vs. 2019, p < 0.001, D = 0.99; KS test 2019 vs. 2021, p < 0.001, D = 0.10). Moreover, we used a Generalized Additive Model (GAM) that included spatial and environmental predictors (i.e., canopy cover calculated from multispectral NDVI and photogrammetrically derived digital elevation model) to model TIR temperature from a transect along the main river channel. This model explained 89% of the deviance, and the predictor variables showed statistical significance. Collectively, our study underscored the potential of a multispectral/TIR sensor to assess thermal heterogeneity in large and complex river systems.

Barker, Matthew I. (ORCID:0000000252864930)↗

Analysis and Validation of PMT s Waveforms in ICARUS LArTPC Using Monte Carlo Simulations

ICARUS (Imaging Cosmic and Rare Underground Signals) serves as the Far Detector in the Short Baseline Neutrino (SBN) program at Fermilab, playing a central role in investigating the potential existence of sterile neutrinos in the eV squared mass range. The detector consists of two large Liquid Argon Time Projection Chambers (LArTPCs) with a total capacity of 760 tons of liquid Argon. A key component of the system is its array of 360 Photo-Multiplier Tubes (PMTs), which detect the scintillation light produced by charged particles in liquid Argon; the fast scintillation signal enables accurate event timing, triggering, and reconstruction. Together with the TPC and CRT systems, the PMTs ensure precise interaction time measurements, which are crucial for distinguishing neutrino interactions from cosmic-ray backgrounds. ICARUS uses Hamamatsu R5912-MOD PMTs, optimized for cryogenic temperatures, with high quantum efficiency, excellent timing resolution, low dark current (around 10 nA at 1500 V), and broad spectral sensitivity (300–650 nm). These characteristics are crucial for the efficient detection of scintillation light. Analyzing the waveforms of PMT signals allows for a detailed comparison between experimental data and Monte Carlo simulations. This analysis is fundamental for improving the accuracy of neutrino event reconstruction, enhancing detector calibration, and optimizing the detector's performance for current and future operations.

Brio, V. [Catania U.] (ORCID:0009000088807391)↗

Technical Performance and Cost Optimization of Unobtrusive Multi-static Serial LiDAR Imager (UMSLI) for Wide-area Surveillance and Identification of Marine Life at Marine Energy Installations

Florida Atlantic University developed an underwater optical monitoring system prototype - Unobtrusive Multi-static Serial LiDAR Imager (UMSLI) - suitable for marine energy full project lifecycle observation (baseline, commissioning, and decommissioning), with an automated real-time classification of marine animals. With precursor 2014 DOE funding (award DE-EE0006787), a prototype UMSLI was demonstrated in a controlled laboratory environment and achieved a TRL 6. This EERE DE-EE0007828 award aimed to both increase the TRL of the UMSLI by improving the technology performance (e.g., increase distance of marine animal target detection capability, add additional species classification capabilities, improve the system performance during the day, etc.) and reduce the cost. The UMSLI presents a novel application of underwater distributed Light Detection And Ranging (LiDAR), an advanced remote sensing method that uses light in the form of laser pulses for an application, this paired with an algorithm provides 360 degrees underwater detection, imaging, and classification of marine life. This solution for underwater monitoring of biota preserves the advantages of traditional optical and acoustic solutions while overcoming many associated disadvantages for marine energy site environmental monitoring, such as difficulties in species detection and classification in low light or night and turbid environments. This new approach is a purposefully designed, reconfigurable adaptation of an existing class 3B laser technology into one UMSLI instrument that can be easily mounted on or around different classes of marine energy equipment, such as devices to capture ocean current energy or wave energy. The system uses relatively low average power, utilizes far-red (> 635nm) laser illumination to be invisible and eye-safe to marine animals, is compact, and cost-effective. The equipment is designed for long-term, maintenance-free operations (i.e., current design is targeting more than 7 days continuous operation), to inherently generate a sparse primary dataset that only includes detected anomalies, and to allow robust real-time automated animal classification and identification with a low data bandwidth requirement. The technology’s overarching goal for application, is a system that can be deployed to collect pre-installation baseline species observations at a proposed marine energy deployment site with minimal post-processing overhead. The envisioned system will also produce high-resolution imagery of marine animals through a wide range of conditions and support automated tracking and notification of the presence of managed animals within established perimeters of marine energy equipment to satisfy deployed marine energy projects’ endangered and threatened species monitoring requirements. Through the current project, we demonstrated the UMSLI prototype in an operational environment and increased the UMSLI’s Technology Readiness Level from 6 to 7. The project resulted in many novel technologies, including: 1) an eye-safe red laser based, low-cost LiDAR system that can detect targets up to 10 meters distance; 2) the GAN-based machine learning underwater LiDAR image enhancement technique (this is the first known application of GAN technique in underwater LiDAR); 3) LiDAR-based real-time automated detection capabilities; and 4) a template matching based automated classification tool. These technologies build a solid foundation for future efforts to develop an extended range electro-optical monitoring system suitable for marine energy deployments. In addition to technology development, a key lesson learned is that addressing regulatory and safety requirements must be front and center in any marine energy monitoring applications.

16 TIDAL AND WAVE POWER↗