At least 649 records · Page 36

High-Torque Heavy-Rare-Earth-Free Electric Motor Thermal Management

This project is part of a multi-lab Next-Generation Reliable Electric Drive Systems for Medium and Heavy-Duty Vehicles (NEXT-DRIVE) project led by Oak Ridge National Laboratory (ORNL), and including NREL, Sandia National Laboratories (SNL), and Ames Laboratory that leverages research expertise and facilities of these national labs to develop tools and approaches for reducing the design and development time of new electric drive technologies for medium and heavy-duty vehicles (MHDVs) and their associated costs while increasing reliability and asset utilization. The Next-Drive project aligns with the DOE's goals by introducing high-fidelity multi-physics and AI/ML-based modeling to design low-cost, highly reliable, and longer-lifetime drivetrains, aiming to achieve 25 years of progress in 5 years. The efforts of this project will focus on NEXT-DRIVE Task 4 (led by ORNL, NREL, and AMES) - developing high-fidelity modeling framework and identifying technologies enabling heavy-rare-earth-free electric motors for medium- and heavy-duty vehicles to achieve 1 million miles of operation. Contrary to conventional approaches that optimize the motor for power density, the focus will be to identify motor designs that achieve the best trade-off between motor power density and durable operation. NREL tasks include development of high-fidelity motor thermal models incorporating rotor windage losses and identification, evaluation and measurement of motor interface materials in key thermal pathways. The poster summarizes NREL's accomplishments for the first half of FY 2025 and outlines future plans.

33 ADVANCED PROPULSION SYSTEMS↗

High-energy-density-physics measurements in implosions using Bayesian inference

Convergent high-energy-density (HED) experimental platforms are used to study matter under some of the most extreme conditions that can be produced on Earth, comparable to the interior of stars. There are many challenges in using these systems for fundamental measurements currently being addressed by new analysis methods, such as the combination of a reduced physics model and Bayesian inference, allowing a self-consistent inference of physical quantities with a robust error analysis. These methods in combination with simple (as compared to inertial confinement fusion implosions) implosion platforms, which can be modified to show sensitivity to different physical mechanisms of interest, are used to study the physical properties of matter under extreme conditions. This work discusses a subset of implosion targets for studying opacity effects, electron-ion equilibration, and thermal conductivity and, as an example, a system consisting of a thick-shelled, gas-filled laser-direct-drive implosion is used to show how a reduced model and Bayesian inference can help inform experimental design decisions such as diagnostic choice. It is shown that for this system that a combination of neutron and x-ray self-emission diagnostics is critical for constraining the details of the thermodynamic states in the system and that the conductivity exponent in a Spitzer like framework can be constrained to the 30% level in deuterium at gigabar conditions. Furthermore, this process can be applied to many HED systems to make underlying model assumptions explicit and facilitate experimental design and analysis.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

NMPC for Mode-Switching Operation of Reversible Solid Oxide Cell Systems

Solid oxide cells (SOCs) are a promising dual-mode technology that generates hydrogen through high-temperature water electrolysis and generates power through a fuel cell reaction that consumes hydrogen. Reversible operation of SOCs requires a transition between these two modes for hydrogen production setpoints as the demand and price of electricity fluctuate. Moreover, a well-functioning control system is important to avoid cell degradation during mode-switching operation. In this work, we apply nonlinear model predictive control (NMPC) to an SOC module and supporting equipment and compare NMPC performance to classical proportional integral (PI) control strategies, while ramping between the modes of hydrogen and power production. While both control methods provide similar performance in many metrics, NMPC significantly reduces cell thermal gradients and curvatures (mixed spatial-temporal partial derivatives) during mode switching. A dynamic process flowsheet of the reversible SOC system was developed in the open-source, equation-based IDAES modeling framework. Our IDAES dynamic simulation results show that NMPC can ramp the SOC system between hydrogen and power production targets within short mode-switching times. Moreover, NMPC can comply with operating limits in the SOC system more effectively than PI, and only NMPC can directly enforce user-specified limits for mixed spatial-temporal partial derivatives of temperature. This allows for management of the trade-off be-tween operating efficiency and cell degradation, which is dependent on these temperature curvatures.

Li, Mingrui↗

Thermal-Hydraulics Modeling and Simulations of Hot Pool Using the SAS-CFD Coupled Code

The main goal of this activity is to test the dynamic coupling of the SAS4A/SASSYS-1 (SAS) and CFD models, using a recently patched version of the SAS code intended to address an undocumented limitation that hindered the Versatile Test Reactor (VTR) simulation efforts in FY21. As described in previous VTR calculation reports, the undocumented limitation in SAS v5.4 does not allow the user to activate the CFD coupling option during restart calculations. Since the analysts were unaware of this limitation, prior SAS-CFD simulation results for the protected station blackout (PSBO) transient were erroneous. Root-cause analysis was performed to determine the cause of this undocumented limitation in SAS v5.4, the SAS software was updated in a new patch, and the SAS-CFD simulations were repeated with this patched software. The results of the SAS-CFD simulations documented in this report show that the software patch does address the cited issue, and that the patched software indeed supports the activation of the CFD coupling model in restart calculations. The SAS development team will determine the schedule for implementing the patch in an official software release. This report documents updated SAS-CFD simulations of the PSBO transient response in the VTR. The hot pool is modeled with the CFD code STAR-CCM+, which is coupled at the flow boundaries to the SAS model of the primary heat transport system. SAS computes the mass flow rate and temperature at each core subassembly outlet, the thermal insulation cavity bypass, and the IHX inlet windows. CFD in turn computes the absolute pressure and temperature at each of these boundaries. The SAS code will ignore the temperature data at flow boundaries where flow is directed into the hot pool, i.e., at the core subassembly outlets unless flow reversal occurs. Similarly, CFD will ignore temperature data at boundaries where the flow is directed out of the hot pool, i.e., at the IHX inlets except under flow reversal. The focus of this work is to ensure that the SAS software patch addresses the undocumented limitation described in prior VTR calculation reports, rather than the accurate assessment of thermal stratification in the VTR during protected transients. This motivates the development of a new, simplified CFD model with a coarser mesh to accelerate the testing process. The updated model, and simplifying assumptions, are documented in this report. In future work, the thermal stratification assessment should be performed in more detail. The simplified CFD model can be improved by performing grid convergence studies sensitivity studies of turbulence parameters (e.g., Prandtl number, turbulence production and dissipation parameters) on temperature distributions and thermal stratification.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Plasma thermal transport with a generalized 8-moment distribution function

Moment equations that model plasma transport require an ansatz distribution function to close the system of equations. The resulting transport is sensitive to the specific closure used, and several options have been proposed in the literature. Two different 8-moment distribution functions can be generalized to form a single-parameter family of distribution functions. The transport coefficients resulting from this generalized distribution function can be expressed in terms of this free parameter. This provides the flexibility of matching the 8-moment model to some validating result at a given magnetization value, such as Braginskii’s transport, or the more recent results of Davies et al. [Physics of Plasma, 28, 012305 (2021)]. Here, this process can be thought of as solving for the 8-moment distribution function that matches the value of a transport coefficient given by a Chapman-Enskog expansion, while retaining the improved physical properties, such as finite propagation speeds and time dependence which belong to the hyperbolic moment models. Since the presented generalized distribution function only has a single free parameter, only a single transport coefficient can be matched at a time. However, this generalization process may be extended to provide multiple free parameters. The focus of this Brief Communication is on the dramatically improved thermal conductivity of the proposed model compared to the two base moment models.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thermal Hydraulic Experimental Test Article: Second Year of Testing with Secondary Sodium System (Fiscal Year 2025 Final Report)

The Thermal Hydraulic Experimental Test Article (THETA) is currently installed in the Mechanisms Engineering Test Loop (METL) 28” test vessel #4. Both the primary and secondary sodium systems remain online to facilitate continued testing. This fiscal year, work was performed using a COMSOL Multiphysics magnetohydrodynamic model to characterize flow more accurately in the secondary electromagnetic flowmeters. Experimental campaigns were then performed to study the thermal hydraulic differences between sodium and water as a surrogate fluid in the THETA geometry as well as a study to better characterize and understand temperature oscillations that exist at the outlet of the core to the hot pool. A peer-reviewed article was published in the ASME Journal of Nuclear Engineering and Radiation Science detailing the THETA facility and providing an overview of a test that was performed with the primary and secondary system online [1]. Work continues to develop a database to house experimental THETA data to better facilitate collaboration with industry and laboratory partners for their use of the data for code benchmarking/validation. THETA remains fully operational and is positioned for continued testing in fiscal year 2026.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Accelerating Nuclear-Integrated Data Centers in the USA: SWOT Analysis, Power-Thermal Management Strategies, and Industrial-Scale Demonstration and Potential Deployment

Driven by the growth in digital services, cloud computing, AI, and manufacturing, data centers face rising energy demands that challenge traditional power sources and cooling efficiency. This study explores using nuclear power to meet these demands, focusing on accelerated reactor technology deployment and highlighting needs such as N+1/N+2 power supplies and integrated power-thermal management. A SWOT analysis addresses grid connectivity, reactors, and site selection, particularly DOE sites. Reactor technology demonstration and deployment could be accelerated by leveraging test facilities such as MARVEL, MAGNET, TED, FAS, DOME, LOTUS, ATR, Energy System Proving Grounds, and upcoming Energy Launch Pads, along with modeling and simulation tools such as RELAP5, MOOSE, VERA, RAVEN, and FORCE. The potential power and thermal management options, including various cooling technologies, waste-heat utilization, and an industrial-scale demonstration plan, aim to accelerate the integration of nuclear power and data centers in the USA, while emphasizing community and stakeholder engagement and synergistic efforts.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Nonlinear thermodynamic computing out of equilibrium

We present the design for a thermodynamic computer that can perform arbitrary nonlinear calculations in or out of equilibrium. Simple thermodynamic circuits, fluctuating degrees of freedom in contact with a thermal bath and confined by a quartic potential, display an activity that is a nonlinear function of their input. Such circuits can therefore be regarded as thermodynamic neurons, and can serve as the building blocks of networked structures that act as thermodynamic neural networks, universal function approximators whose operation is powered by thermal fluctuations. We simulate a digital model of a thermodynamic neural network, and show that its parameters can be adjusted by genetic algorithm to perform nonlinear calculations at specified observation times, regardless of whether the system has attained thermal equilibrium. This work expands the field of thermodynamic computing beyond the regime of thermal equilibrium, enabling fully nonlinear computations, analogous to those performed by classical neural networks, at specified observation times.

Whitelam, Stephen [Lawrence Berkeley National Labo↗

Adaptive variational quantum minimally entangled typical thermal states for finite temperature simulations

Scalable quantum algorithms for the simulation of quantum many-body systems in thermal equilibrium are important for predicting properties of quantum matter at finite temperatures. Here we describe and benchmark a quantum computing version of the minimally entangled typical thermal states (METTS) algorithm for which we adopt an adaptive variational approach to perform the required quantum imaginary time evolution. The algorithm, which we name AVQMETTS, dynamically generates compact and problem-specific quantum circuits, which are suitable for noisy intermediate-scale quantum (NISQ) hardware. We benchmark AVQMETTS on statevector simulators and perform thermal energy calculations of integrable and nonintegrable quantum spin models in one and two dimensions and demonstrate an approximately linear system-size scaling of the circuit complexity. We further map out the finite-temperature phase transition line of the two-dimensional transverse field Ising model. Finally, we study the impact of noise on AVQMETTS calculations using a phenomenological noise model.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Leveraging MARVEL and SPHERE to Demonstrate NEAMS Thermal Hydraulics Codes

The Single Primary Heat Extraction and Removal Emulator (SPHERE) and Microreactor Applications Research Validation and Evaluation (MARVEL) were utilized to demonstrate thermal hydraulics codes of the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program. A recent long-duration test of a sodium heat pipe conducted at the SPHERE facility was utilized for the validation of the heat pipe code Sockeye. The first 10 hours of operation featured a startup of the heat pipe from room temperature; this portion was modeled with Sockeye and compared to the experimental data. Measurements included several thermocouple measurements across the length of the heat pipe surface. Two of Sockeye’s heat pipe models were applied to experiment, as well as several models of the cooling at the condenser end of the heat pipe. Sockeye results gave a decent match to the experimental data, with notable discrepancy in the condenser section, where experimental data indicated a significant inactive length of the heat pipe. The MARVEL microreactor was modeled through a coupled simulation of System Analysis Module (SAM) and SubChannel Module (SCM). This multiscale coupled simulation was performed as an exercise to demonstrate the compatibility and applicability of these codes for thermal-hydraulic analysis of microreactors. The coupling between the SCM and SAM codes for multiscale modeling of MARVEL, was achieved through a domain overlapping approach. In this example a transient SAM simulation provided boundary conditions to SCM, and SCM provided pressure drop to SAM.

97 - MATHEMATICS AND COMPUTING↗

Latent heat thermal energy storage performance maps enabling fast & accurate building energy simulations

Thermal energy storage (TES) using phase change materials (PCMs) has gained attention as an effective approach to manage energy demand fluctuations and shift peak building loads. PCM embedded heat exchangers (PCM-HXs) offer high energy storage density and low temperature variation during phase change, being suitable for load-shifting applications. However, this component is typically evaluated using computationally expensive methods, which present significant challenges when the ultimate goal is to assess the performance of PCM-HX integrated thermal energy storage systems in the full building context. In this paper, we present a methodology to generate highly accurate and computationally efficient PCM-HX performance maps which can be easily integrated into building energy simulation tools to analyze the feasibility of space conditioning systems with latent heat PCM-based TES. The performance maps are generated using a computationally efficient PCM-HX simulation tool based on a Generalized Resistance-Capacitance Model (GRCM) which can simulate arbitrary PCM-HXs with high accuracy and significantly less computational effort compared to full CFD simulations. The methodology was verified for a case study considering a 5-ton (~17.5 kW) air-to-water heat pump-thermal energy storage system (HP-TES), which was co-simulated in Modelica for a DOE prototype small-office building in Vienna, Austria, using Spawn of EnergyPlus™. The TES performance maps provided accurate predictions of PCM-HX behavior when used as Modelica component, with deviations within 2-4% while also achieving at least 103 computational time reduction. Leveraging this faster prediction capability, four PCMs with different melting temperatures for cooling (12°C, 16°C) and heating (31°C, 36°C) were assessed to investigate their impact on system performance. This work highlights the importance of robust PCM-HX models for efficient and high-fidelity building-level simulations, presenting new opportunities for advanced control strategy development and parametric analysis of TES configurations in a computationally efficient manner

Modelica Building Simulations↗

Performance assessment of active insulation systems in residential buildings for energy savings and peak demand reduction

Active insulation systems (AISs) in buildings are envelopes that integrate thermal insulation, thermal energy storage, and controls. Although different designs for AISs have been proposed in the literature, a comprehensive analysis of feasible AISs is lacking. This paper discusses the energy performance, peak demand reduction potential, and performance characteristics of an AIS that uses a concrete wall as thermal mass sandwiched between two solid-state thermal switches (STSs). These STSs change their thermal conductivity using an on/off metal switch to create or break a thermal bridge across the STS. This paper first describes the experimental setup, used to determine the ratio of thermal resistance during R-high (low thermal conductivity) and R-low (high thermal conductivity) states of the STSs. This ratio was then used in whole-building energy simulations to evaluate the performance of AIS walls across different climate zones with/without a freeze timer of 60 min. The timer was added to reduce the number of switches of STSs from one state to another, and hence the energy needed for these switches. Analysis of the switching frequency and interval of STSs, thermal conductivity of walls, impact of wall orientation, and heat transfer through the wall from the use of AIS at different climate zones/locations were performed. The simulation results show that the AIS can achieve energy savings ranging from ~980 to 2,290 kWh in a single-family home with a floor area of ~220 m 2 compared with an IECC 2018 baseline. We found the energy savings was higher in dry climate zones which represent 17% of residential buildings in the United States, compared to humid or marine climate.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Analysis of Combi Heat Pump System Configurations for Space Conditioning and Domestic Hot Water Heating in Residential Buildings

Combi heat pump systems, also referred to multifunctional variable refrigerant flow heat recovery (MF-VRFHR) systems, are specifically designed for residential applications to manage both space conditioning and domestic hot water (DHW). They have attracted attention due to their potential for energy conservation through heat recovery. The incorporation of a hot water tank introduces various system configurations, each characterized by distinct pros and cons related to energy efficiency, system stability, and maintenance. Despite this, a critical gap exists as the specific energy performance remains unquantified under diverse operational modes (e.g., heating mode and heat recovery mode). This paper aims to bridge this gap by conducting a comprehensive comparative analysis of two prevalent system configurations while considering feasible proposed control logics. Configuration 1 integrates a separate hot water tank and a refrigerant-to-water heat exchanger (HEX), also known as a Hydro Kit while Configuration 2 incorporates a refrigerant-wrapped hot water tank. To facilitate this analysis, we developed high-fidelity system models for both configurations in Modelica, capturing system dynamics and detailed control sequences effectively. These system models were built upon the TIL library for HVAC equipment components and the Buildings library for residential building thermal load calculations. The validation of the simulation testbed utilized data from experiments conducted in the PNNL lab home for Configuration 1. To establish the simulation testbed for Configuration 2, we extended the modeling setup derived from Configuration 1. This extension specifically involved substituting the separate hot water tank and Hydro Kit with a refrigerant-wrapped hot water tank of similar sizing sourced from an actual product. The simulation analysis of heating-only and heat recovery modes reveals that Configuration 2 not only saves energy and maintains warmer tank temperatures but also demonstrates faster water heating capabilities. This is attributed to decreased energy loss and improved heat transfer. The study encompasses a wide range of scenarios, considering diverse thermal loads and water usage patterns across heating and heat recovery modes. Overall, the comprehensive results indicate that Configuration 2 achieves energy savings ranging from 3.5% to 12.2% compared to Configuration 1, depending on factors such as water usage patterns, thermal loads, and operational modes.

Configuration, Comparison, Multi-functional, Resid↗

Analysis of Building Model Forecasts using Autonomous HVAC Optimization System for Residential Neighborhood

Heating, ventilation, and air conditioning (HVAC) systems account for the highest share of home energy consumption in the United States. Optimized HVAC control can provide thermal improved comfort to the occupants, improve energy efficiency, reduce energy cost, and support grid services. In this paper, we discuss a multi-agent and cloud-based software framework that has been deployed in occupied residential neighborhood. This system enables automatic data collection, learning, optimization, and dispatches signals to neighborhood devices. HVAC optimization is based on model predictive control (MPC). Since the operational performance of MPC depends on model forecasting accuracy, it is crucial to evaluate the model continuously and modify or retrain it as necessary. In this research, we developed an automated workflow to evaluate the performance of temperature and power forecasts based on measured data in the real world. This will provide researchers with a deeper understanding of the model and how it can be improved.

Lebakula, Viswadeep↗

Development & Experimental Validation of a Generalized Resistance-Capacitance Model for Numerical Simulation of Phase-Change Material Embedded Heat Exchangers

Latent heat thermal energy storage (LHTES) using phase change material (PCM) has attracted increased attention as a viable solution for overcoming the mismatch between energy supply and demand for renewable energy-based systems. PCM-embedded heat exchangers (PCM-HX) have the potential to significantly improve thermal performance due to high storage capacity and low temperature variation during the phase change process. Most models for simulating LHTES heat transfer use Computational Fluid Dynamics (CFD) simulations, which have high computational costs resulting from considering the complex and time-dependent physics relevant to PCM-HXs. In this paper, a Generalized Resistance Capacitance-based Model (GRCM) was developed to predict the thermal performance of arbitrary PCM-HXs in a computationally efficient manner without compromising modeling accuracy. The GRCM is exercised for three case studies: (i) verification for a single-slabbed finned PCM-HX, (ii) verification and validation for a copper foam/paraffin composite PCM-HX, and (iii) validation for a straight tube annular finned PCM-HX. The copper foam PCM-HX uses an electric heater at the top of HX, while the other two configurations utilize water as heat transfer fluid. For the single-slabbed finned PCM-HX melting case, the mean deviation in average PCM temperature predicted by the GRCM compared to the CFD model was between 0.56 – 0.73 K, with maximum temperature deviation of 2.68 K. For the HTF outlet temperature, the validation results showed that GRCM prediction matches very well with experimental data, with mean temperature deviation of 0.24 K during melting case, while for solidification case was 0.34 K. These results showcase the GRCM’s capability for accurately reproducing the thermal characteristics of PCM-HXs with considerably lower computational effort.

42 ENGINEERING↗

Preliminary Primary System Thermal Fluids Analysis of a Horizontal Compact HTGR

The Horizontal Compact High Temperature Gas Reactor (HC-HTGR) is being designed by a multi-disciplinary team of nuclear, mechanical, and structural engineers, under the support of a DOE-NE Advanced Reactor Demonstration Program’s Advanced Reactor Concepts-20 (ARC-20) award. The objective of this ARC-20 project is to deliver a conceptual design for the proposed HC-HTGR in 3 years and support its commercialization as a safe, low-cost HTGR. Argonne National Laboratory (Argonne) is collaborating on the thermal hydraulic design and analysis of the HC-HTGR reactor pressure vessel internals. The scope of this work includes ensuring the reactor is able to maintain maximum core temperatures below designated safety thresholds during normal operation, shutdown, and accident conditions. This report documents the preliminary thermal hydraulic analysis of the HC-HTGR core design performed with a 1D fluid-3D solid coupled model built using the System Analysis Module (SAM). This assembly level model was utilized to inform the core assembly design, predict the temperature distribution in the peak power assembly including the peak fuel temperature, coolant channel outlet temperatures, and graphite temperature gradients. A key result of this analysis was the determination that the peak fuel temperature remains below the safety threshold of 1250°C. Additionally, this model was used to assess the assembly coolant channel and bypass flow mass flow rate distribution. Following the assembly level analysis, attention turned to the development of a full core reduced order model to be used to predict the core wide coolant flow distribution and to model certain operational and accidental transients.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Thermal Analysis of Liquid and Air Cooling of High-Power-Density Integrated Motor Drives

Thermal management is a crucial aspect in the design of motor and drive systems. This paper introduces a coordinated cooling approach utilizing both liquid and air to enhance the integrated motor drive's power density. The proposed solution incorporates a shared water jacket to cool both the machine and power electronics, combined with forced air ventilation for the end windings and rotor. This approach is structurally simpler, less expensive, and more effective than conventional non-interacting cooling schemes. The paper addresses the modeling of key thermal features and nonlinearities including material anisotropy, contact thermal resistance, and uneven winding loss distributions. In addition, this study utilizes a more detailed model of the loss distribution among the winding turns in each slot that delivers a higher level of accuracy. Finite Element Analysis (FEA) results demonstrate the effectiveness of the integrated cooling system for efficiently cooling the designed integrated motor drive system.

42 ENGINEERING↗

Preliminary Sensitivity Analysis for Sensors Impacts on Building Control Performance

This report describes the preliminary sensitivity analysis for sensor impacts on building control performance through the US Department of Energy’s Oak Ridge National Laboratory’s Flexible Research Platform (FRP-2) building. The rooftop unit system provides cooling and heating to the building. The main heating coil is a gas heating coil. Each zone is served by a variable air volume box with an electricity reheat coil. The rooftop unit and variable air volume box controls adopted the practical control sequences from ASHRAE Guideline 36-2018: High-Performance Sequences of Operation. For sensors, the incipient (time-changing) sensor errors, including bias sensor error and precision sensor error, are the inputs of interest. The outputs are energy consumption and thermal comfort (e.g., the predicted percentage of dissatisfied occupants). The large-scale simulation (3,600 cases) was conducted on a cloud platform by integrating sensor errors and ASHRAE Guideline 36 control sequences into an emulator based on the EnergyPlus simulation program with Python energy management system feature. The surrogate models were developed based on cloud simulation results. The uncertainty analysis showed that the sensor errors substantially affect building energy consumption and thermal comfort. The sensitivity analysis shows a ranking of sensor error impacts for each interested output item (e.g., cooling energy, reheat coil heating energy, predicted percentage of dissatisfied occupants). In FY 2022, sensor locations, types, and costs will be evaluated. The field test in Oak Ridge National Laboratory’s Flexible Research Platform building regarding sensor impacts will also be performed. Finally, a comparative analysis will be conducted based on the field test results and emulator results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗