First-Principle Dynamic Electro-Thermal Numerical Model of a Scanning Radiometer for Earth Radiation Budget Applications

Low Earth Observing instruments that are used to monitor the incoming solar and outgoing long wave radiation have been a crucial part of studying the Earth’s radiation budget for the past three decades. These instruments go through several robust design phases followed by vigorous ground calibration campaigns to set their baseline characterization spectrally, spatially, temporally and radiometrically. The knowledge from building and calibrating these instruments has aided in technology advancements and the need for developing more accurate instruments has increased. In order to understand the on-ground instrument performance, NASA Langley Research Center has partnered with the Thermal Radiation Group of Virginia Tech to develop a first-principle, dynamic, electrothermal, numerical model of a scanning radiometer that can be used to enhance the interpretation of an Earth radiation budget-like instrument on orbit. This paper will summarize the current efforts of developing this high-fidelity end-to-end model and also highlight how it can be applied to an Earth radiation budget instrument.

Ashraf, Anum Rauf Bark↗

A small instrument pointing system for shuttle sortie missions

A small instrument pointing system (SIPS) has been conceptually designed as a means of interfacing smaller astronomical instruments with the ESA spacelab system on shuttle sortie missions. Small instruments are defined as being up to 0.9 meter in diameter, three meters in length, and 340 kilograms in mass. Two independently supported instruments are deployed on a common pedestal to give a hemispherical field of view. The instruments are each supported at their centers-of-mass in bi-axial gimbal systems for fine pointing. An optional roll gimbal can be used to give roll about the line of sight. Instruments are held in environmental canisters which protect them thermally, and acoustically as well as from contamination. The canister facilitates instrument integration and provides interfaces to all spacelab subsystems. The SIPS is a total instrument support system for small sortie mission instruments.

Henrikson, C. C.↗

ASTER, a multinational Earth observing concept

The Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER) is a facility instrument selected for launch in 1998 on the first in a series of spacecraft for NASA's Earth Observing System (EOS). The ASTER instrument is being sponsored and built in Japan. It is a three telescope, high spatial resolution imaging instrument with 15 spectral bands covering the visible through to the thermal infrared. It will play a significant role within EOS providing geological, biological, land hydrological information necessary for intense study of the Earth. The operational capabilities for ASTER, including the necessary interfaces and operational collaborations between the US and Japanese participants, are under development. EOS operations are the responsibility of the EOS Project at NASA's Goddard Space Flight Center (GSFC). Although the primary EOS control center is at GSFC, the ASTER control facility will be in Japan. Other aspects of ASTER are discussed.

Bothwell, Graham W.↗

Studies of Potential Mars Surveyor 1998 Landing Sites

The 1998 lander payload consists of a descent imager, the Mars Volatiles and Climate Surveyor (MVACS) instruments (lander stereo camera, arm-mounted close-up imager, meteorology package, thermal and evolved gas analyzer), and a LIDAR instrument. The mission focuses on assessment of near-surface water ice in the south polar region, and the volatile and climate history of Mars. In order to achieve these objectives, the landing site must allow access to polar layered deposits by the robotic arm, which may be able to dig as much as 0.5 m below the surface. Hence, the presence of recent aeolian debris at the landing site may adversely affect the ability of the MVACS instruments to gather the samples and acquire data needed to properly address the science objectives. The studies described here include mapping surface units in the landing region (73S - 77S, 140W - 230W) to infer the distribution of aeolian debris and to identify potential landing sites where mantling is minimal. Because the '98 lander will not be able to survive very low temperature conditions, this study also includes mapping of south polar seasonal frost retreat based on Viking Orbiter images. The results of this work, in conjunction with complementary studies by other investigators, will facilitate the selection of the Mars Surveyor 1998 landing site (and backup) by the summer of 1998.

Herkenhoff, K. E.↗

Thermal Decomposition of Calcium Perchlorate/Iron-Mineral Mixtures: Implications of the Evolved Oxygen from the Rocknest Eolian Deposit in Gale Crater, Mars

A major oxygen release between 300 and 500 C was detected by the Mars Curiosity Rover Sample Analysis at Mars (SAM) instrument at the Rocknest eolian deposit. Thermal decomposition of perchlorate (ClO4-) salts in the Rocknest samples are a possible explanation for this evolved oxygen release. Releative to Na-, K-, Mg-, and Fe-perchlorate, the thermal decomposition of Ca-perchlorate in laboratory experiments released O2 in the temperature range (400-500degC) closest to the O2 release temperatures observed for the Rocknest material. Furthermore, calcium perchlorate could have been the source of Cl in the chlorinated-hydrocarbons species that were detected by SAM. Different components in the Martian soil could affect the decomposition temperature of calcium per-chlorate or another oxychlorine species. This interaction of the two components in the soil could result in O2 release temperatures consistent with those detected by SAM in the Rocknest materials. The decomposition temperatures of various alkali metal perchlorates are known to decrease in the presence of a catalyst. The objective of this work is to investigate catalytic interactions on calcium perchlorate from various iron-bearing minerals known to be present in the Rocknest material

Bruck, A. M.↗

Results of thermal environment measurements on the thermal cannister experiment and get away special enclosure

Because the OSS-1 pallet contained a variety of instruments with irregular surface geometry and properties which limited predictability, the total absorbed flux on thermal canister radiators was measured to determine heat rejection capability. The instrumentation and sensor cup design and locations for the thermal canister experiment are illustrated. Graphs show flux sensor history in hot and coal orbits. Kapton erosion is also considered. Results show that the flux levels measured in all STS attitudes are higher than predictions. In cold and moderate attitudes, flight results are a factor of two to three higher than predicts. In hot attitude, much better agreement occurred. It is concluded that in cold or moderate attitudes other sources may be contributing to added inputs (albedo, Earth shine, shuttle background). In hot attitude, smaller differences could be attributed to coatings assumptions or calculation uncertainty.

Ollendorf, S.↗

Fault tolerant capabilities of the Cosmic Background Explorer attitude control system

The Cosmic Background Explorer (COBE), which was launched November 18, 1989 from Vandenberg Air Force Base aboard a Delta rocket, has been classified by the scientific community as a major success with regards to the field of cosmology theory. Despite a number of anomalies which have occurred during the mission, the attitude control system (ACS) has performed remarkably well. This is due in large part to the fault tolerant capabilities that were designed into the ACS. A unique triaxial control system orientated in the spacecraft's transverse plane provides the ACS the ability to safely survive various sensor and actuator failures. Features that help to achieve this fail-operational system include component cross-strapping and autonomous control electronics switching. This design philosophy was of utmost importance because of the constraint placed upon the ACS to keep the spinning observatory and its cryogen-cooled science instruments pointing away from the sun. Even though the liquid helium was depleted within the expected twelve months from launch, it is still very much desirable to avoid any thermal disturbances upon the remaining functional instruments.

Placanica, Samuel J.↗

A Simplified Model of VIPER Thermal Management System. Part II: Integrated Vehicle

NASA’s Volatiles Investigating Polar Exploration Rover (VIPER) thermal management system (TMS) relies on four loop heat pipes (LHPs) to transport electronic waste heat to the vehicle cooling radiative surface and avoid overheating. The TMS has also ten constant conductance heat pipes (CCHPs) dedicated to balance the thermal load within the internal environment where the avionics boxes are mounted, also called warm electronic box (WEB), and to transport the heat from two of the science payload instruments. The TMS also uses two thermal straps to thermally link the batteries to the WEB. These thermal components, in addition to heaters, thermostat, multi-layer insulation (MLIs), and isolators forms the core of the VIPER TMS. The complex heat transport balance managed by the TMS is challenging to characterize and model. The more fidelity and granularity of a model, the more costly the computational resources needed and the longer the simulation and modeling time. When the priority is to provide quick but reliable assessments of the thermal performance or real time thermal feedback for training of console operators, simplified modeling tools are needed. To satisfy that need, this paper describes the effort to develop and correlate a model of VIPER TMS based on control volume approach. The correlation effort in particular focuses on hibernation, cold thermal balance, and hot thermal balance data from the integrated vehicle thermal vacuum (TVAC) test. Thus, the correlated model captures the heat leaks during hibernations and the performance at two extremes, bounding, operating scenarios.

Loop Heat Pipe↗

A Simplified Model of VIPER Thermal Management System. Part II: Integrated Vehicle

NASA’s Volatiles Investigating Polar Exploration Rover (VIPER) thermal management system (TMS) relies on four loop heat pipes (LHPs) to transport electronic waste heat to the vehicle cooling radiative surface and avoid overheating. The TMS has also ten constant conductance heat pipes (CCHPs) dedicated to balance the thermal load within the internal environment where the avionics boxes are mounted, also called warm electronic box (WEB), and to transport the heat from two of the science payload instruments. The TMS also uses two thermal straps to thermally link the batteries to the WEB. These thermal components, in addition to heaters, thermostat, multi-layer insulation (MLIs), and isolators forms the core of the VIPER TMS. The complex heat transport balance managed by the TMS is challenging to characterize and model. The more fidelity and granularity of a model, the more costly the computational resources needed and the longer the simulation and modeling time. When the priority is to provide quick but reliable assessments of the thermal performance or real time thermal feedback for training of console operators, simplified modeling tools are needed. To satisfy that need, this paper describes the effort to develop and correlate a model of VIPER TMS based on control volume approach. The correlation effort in particular focuses on hibernation, cold thermal balance, and hot thermal balance data from the integrated vehicle thermal vacuum (TVAC) test. Thus, the correlated model captures the heat leaks during hibernations and the performance at two extremes, bounding, operating scenarios.

Thermal Modeling↗

The CHANDRA X-Ray Observatory: Thermal Design, Verification, and Early Orbit Experience

The CHANDRA X-ray Observatory (formerly AXAF), one of NASA's "Great Observatories" was launched aboard the Shuttle in July 1999. CHANDRA comprises a grazing-incidence X-ray telescope of unprecedented focal-length, collecting area and angular resolution -- better than two orders of magnitude improvement in imaging performance over any previous soft X-ray (0.1-10 keV) mission. Two focal-plane instruments, one with a 150 K passively-cooled detector, provide celestial X-ray images and spectra. Thermal control of CHANDRA includes active systems for the telescope mirror and environment and the optical bench, and largely passive systems for the focal plans instruments. Performance testing of these thermal control systems required 1-1/2 years at increasing levels of integration, culminating in thermal-balance testing of the fully-configured observatory during the summer of 1998. This paper outlines details of thermal design tradeoffs and methods for both the Observatory and the two focal-plane instruments, the thermal verification philosophy of the Chandra program (what to test and at what level), and summarizes the results of the instrument, optical system and observatory testing.

Boyd, David A.↗

Cryogenic Insulation Standard Data and Methodologies Project

Extending some recent developments in the area of technical consensus standards for cryogenic thermal insulation systems, a preliminary Inter-Laboratory Study of foam insulation materials was performed by NASA Kennedy Space Center and LeTourneau University. The initial focus was ambient pressure cryogenic boil off testing using the Cryostat-400 flat-plate instrument. Completion of a test facility at LETU has enabled direct, comparative testing, using identical cryostat instruments and methods, and the production of standard thermal data sets for a number of materials under sub-ambient conditions. The two sets of measurements were analyzed and indicate there is reasonable agreement between the two laboratories. Based on cryogenic boiloff calorimetry, new equipment and methods for testing thermal insulation systems have been successfully developed. These boiloff instruments (or cryostats) include both flat plate and cylindrical models and are applicable to a wide range of different materials under a wide range of test conditions. Test measurements are generally made at large temperature difference (boundary temperatures of 293 K and 78 K are typical) and include the full vacuum pressure range. Results are generally reported in effective thermal conductivity (ke) and mean heat flux (q) through the insulation system. The new cryostat instruments provide an effective and reliable way to characterize the thermal performance of materials under subambient conditions. Proven in through thousands of tests of hundreds of material systems, they have supported a wide range of aerospace, industry, and research projects. Boiloff testing technology is not just for cryogenic testing but is a cost effective, field-representative methodology to test any material or system for applications at sub-ambient temperatures. This technology, when adequately coupled with a technical standards basis, can provide a cost-effective, field-representative methodology to test any material or system for applications at sub-ambient to cryogenic temperatures. A growing need for energy efficiency and cryogenic applications is creating a worldwide demand for improved thermal insulation systems for low temperatures. The need for thermal characterization of these systems and materials raises a corresponding need for insulation test standards and thermal data targeted for cryogenic-vacuum applications. Such standards have a strong correlation to energy, transportation, and environment and the advancement of new materials technologies in these areas. In conjunction with this project, two new standards on cryogenic insulation were recently published by ASTM International: C1774 and C740. Following the requirements of NPR 7120.10, Technical Standards for NASA Programs and Projects, the appropriate information in this report can be provided to the NASA Chief Engineer as input for NASA's annual report to NIST, as required by OMB Circular No. A-119, describing NASA's use of voluntary consensus standards and participation in the development of voluntary consensus standards and bodies.

Technology Portfolio System↗

Plutonium isotope ratio measurements by total evaporation-thermal ionization mass spectrometry (TE-TIMS): an evaluation of uncertainties using traceable standards from the New Brunswick Laboratory

The accuracy and precision of isotope amount ratio measurements using thermal ionization mass spectrometry (TIMS) instrumentation are described, and the measurement of Pu materials is emphasized. The mass fractionation observed for Am, Ga, Pu, and U for isotope amount ratio measurements using the total evaporation (TE) technique is compared with theoretical estimates to demonstrate the advantage of the TE methodology and to investigate systematic biases in the major isotope amount ratios of U and Pu certified reference material (CRM) standards from the U.S. provider of CRMs. The quality of the Pu isotopic data generated by TIMS instruments in an analytical laboratory is demonstrated by the application of the double ratio technique to estimate the 241 Pu half-life. Analytical data on traceable Pu CRMs from the New Brunswick Laboratory (NBL), generated as part of routine measurements supporting various programs, are used for this half-life estimation. Although the 241 Pu abundances in CRMs of 136, 137, 138, and 126-A are approximately 200–2000× smaller than those in the 241 Pu material used in the previous Institute for Reference Materials and Measurements (IRMM) evaluation of the 241 Pu half-life, the half-life value estimated in this work shows excellent agreement with the currently accepted value from the IRMM. This agreement also demonstrates the pedigree of the Pu isotopic standards from the NBL and the quality of the isotope amount ratio measurements using TIMS instrumentation. For both the major and minor Pu isotope amount ratios, this report describes the relative importance of the factors affecting the uncertainty of TIMS measurements, which are considered the gold standard in isotope ratio measurements (LA-UR-24-29199).

07 ISOTOPE AND RADIATION SOURCES↗

ATONA TE-TIMS of minor uranium isotopes (FY25 Mid-Year Report)

Isotopic measurements of the minor isotopes of uranium ( 233 U, 234 U, 236 U) are indispensable measures for material accountability and processing history but can be particularly challenging to accurately measure due to the very low abundance of the minor isotopes relative to 238 U, or 235 U in the case of highly enriched uranium (HEU). The goal of this project is to quantify detection limits for minor uranium isotope species at environmental levels (e.g 236 U/ 238 U < 10 -7 ) utilizing an ATONA-outfitted instrument and the Total Evaporation Thermal Ionization Mass Spectrometry (TE-TIMS) method. In the first half of Fiscal Year 2025, we set out to identify a suitable experimental material (Task 1) and to optimize our TE-TIMS measurement routine (Task 2). We have successfully identified a material and are in the process of getting an aliquot shipped to LANL. Simultaneously, we began working on our measurement routine utilizing CRM 112A. The results of each task are discussed in detail below.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Initial Feasibility Assessment and Broader Strategy Development for Fiber Integration via Advanced Manufacturing

Structural health monitoring is critical for ensuring the operational safety and cost-competitiveness of the developing advanced reactor designs. The extreme operational envelopes of these advanced architectures, having operating temperatures ranging 400°C–1,000°C and heightened displacement damage doses, render conventional commercially available piezoelectric transducers and resistive strain gauges unviable. Optical fiber sensors present an attractive solution for advanced radiation-hardened instrumentation due to their high thermal stability and distributed sensing capabilities. However, their deployment in embedded applications can be hindered by the severe thermomechanical strain driven by the coefficient of thermal expansion mismatch between fused silica glass and structural metal alloys like stainless steel (e.g., SS316L).

36 MATERIALS SCIENCE↗

Infrared scanning radiometer

The Apollo 17 infrared scanning radiometer (ISR) experiment for mapping lunar surface thermal emission is reported. The instrument, lunar surface coverage, and the data obtained are discussed.

Low, F. J.↗