Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “thermal camera”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

PROGRESS IN HANFORDS DOUBLE SHELL TANK (DST) INTEGRITY PROJECT

The U.S. Department of Energy's Office of River Protection has an extensive integrity assessment program for the Hanford Site Double-Shell Tank System. The DOE Orders and environmental protection regulations provide the guidelines for the activities used to inspect and maintain 28 double-shell tanks (DSTs), the waste evaporator, and ancillary equipment that compose this system. This program has been reviewed by oversight and regulatory bodies and found to comply with the established guidelines. The basis for the DOE Order 435.1-1 for tank integrity comes from the Tank Structural Integrity Paneled by Brookhaven National Laboratory during the late 1990s. These guidelines established criteria for performing Non-Destructive Examination (NDE), for acceptance of the NDE results, for waste chemistry control, and for monitoring the tanks. The environmental regulations mirror these requirements and allow for the tank integrity program to provide compliant storage of the tanks. Both sets of requirements provide additional guidance for the protection of ancillary equipment. CH2M HILL uses two methods of NDE: visual inspection and Ultrasonic Testing (UT). The visual inspection program examines the primary tank and secondary liner of the DST. The primary tank is examined both on the interior surface above the waste in the tank and on the exterior surface facing the annulus of the DST. The interior surface of the tank liner is examined at the same time as the outer surface of the primary tank. The UT program examines representative areas of the primary tank and secondary liner by deploying equipment in the annulus of the tank. Both programs have led to the development of new equipment for remote inspection of the tanks. Compact camera and enhanced lighting systems have been designed and deployed through narrow access ports (called risers) into the tanks. The UT program has designed two generations of crawlers and equipment for deployment through risers into the thermally hot and radioactive environment. Also extensions were developed to allow inspection of the tank's curve upper (haunch) and lower (knuckle) surfaces. CH2M HILL primarily maintains chemistry control of the DST by ensuring that the concentrations of hydroxide and nitrite ions are favorable with respect to the nitrate ion concentration in the waste. This control program is supported by an extensive sampling program that obtains samples from the supernatant and solid layers in the tank to ensure compliance with the chemical specification. At DOE direction, CH2M HILL has embarked on a waste chemistry optimization program to enhance the protection of the tank surface and the understanding of the parameters that affect general and localized corrosion in the tanks. Over the past decade, DOE has deployed Electrochemical Noise corrosion probes in the DST to monitor localized corrosion. From the information gathered as part of the chemistry control, new information has been identified about the parameters requiring control to ensure tank integrity. CH2M HILL is deploying a series of corrosion probes to test and employ these parameters to provide real time corrosion monitoring of the DSTs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A mobile system for a comprehensive online-characterization of nanoparticle aggregates based on wide-angle light scattering and laser-induced incandescence

A mobile demonstrator for the comprehensive online-characterization of gas-borne nanoparticle aggregates is presented. Two optical measurement techniques are combined, both utilizing a pulsed Nd:YAG laser as light source. Aggregate size and fractal dimension are measured by Wide-Angle Light Scattering (WALS). An ellipsoidal mirror images elastically scattered light from scattering angles between 10° and 165° onto a CCD-camera chip resulting in an almost complete scattering diagram with high angular resolution. Primary particle size and volume fraction are measured by time-resolved Laser-Induced Incandescence (TiRe-LII). Here, particles are heated up to about 3000 K by the short laser pulse, the enhanced thermal radiation signal is detected with gated photomultiplier tubes. Analysis of the signal decay time and maximum LII-signal allows for the determination of primary particle diameter and volume fraction. The performance of the system is demonstrated by combined measurements on soot nanoparticle aggregates from a soot aerosol generator. Particle and aggregate sizes are varied by using different equivalence ratios of the combustion in the generator. Soot volume fraction can be adjusted by different levels of dilution with air. Online-measurements were carried out demonstrating the favorable performance of the system and the potential for industrial applications such as process control and product development. The particle properties obtained are confirmed through transmission electron microscopy analysis on representative samples.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wide Field and Planetary Camera for Space Telescope

The Space Telescope's Wide Field and Planetary Camera instrument, presently under construction, will be used to map the observable universe and to study the outer planets. It will be able to see 1000 times farther than any previously employed instrument. The Wide Field system will be located in a radial bay, receiving its signals via a pick-off mirror centered on the optical axis of the telescope assembly. The external thermal radiator employed by the instrument for cooling will be part of the exterior surface of the Space Telescope. In addition to having a larger (1200-12,000 A) wavelength range than any of the other Space Telescope instruments, its data rate, at 1 Mb/sec, exceeds that of the other instruments. Attention is given to the operating modes and projected performance levels of the Wide Field Camera and Planetary Camera.

Lockhart, R. F.↗

Investigations Using Laboratory Testbeds to Interpret Flight Instrument Datasets from Mars Robotic Missions

The Astromaterials Research and Exploration Science Directorate at the NASA Johnson Space Center (JSC) has laboratory instrumentation that mimic the capabilities of corresponding flight instruments to enable interpretation of datasets returned from Mars robotic missions. The lab instruments have been and continue to be applied to datasets for the Moessbauer Spectrometer (MB) on the Mars Exploration Rovers (MER), the Thermal & Evolved Gas Analyzer (TEGA) on the Mars Phoenix Scout, the CRISM instrument on the Mars Reconnaissance Orbiter Missions and will be applied to datasets for the Sample Analysis at Mars (SAM), Chemistry and Mineralogy (CheMin) and Chemistry & Camera (ChemCam) instruments onboard the Mars Science Laboratory (MSL). The laboratory instruments can analyze analog samples at costs that are substantially lower than engineering models of flight instruments, but their success to enable interpretation of flight data depends on how closely their capabilities mimic those of the flight instrument. The JSC lab MB instruments are equivalent to the MER instruments except without flight qualified components and no reference channel Co-57 source. Data from analog samples were critical for identification of Mg-Fe carbonate at Gusev crater. Fiber-optic VNIR spectrometers are used to obtain CRISM-like spectral data over the range 350-2500 nm, and data for Fephyllosilicates show irreversible behavior in the electronic transition region upon dessication. The MB and VNIR instruments can be operated within chambers where, for example, the absolute H2O concentration can be measured and controlled. Phoenix's TEGA consisted of a calorimeter coupled to a mass spectrometer (MS). The JSC laboratory testbed instrument consisted of a differential scanning calorimeter (DSC) coupled to a MS configured to operate under total pressure (12 mbar), heating rate (20 C/min), and purge gas composition (N2) analogous to the flight TEGA. TEGA detected CO2 release at both low (400-680 C) and high (725-820 C) temperature and an endothermic reaction in concert with the high temperature release. The high-temperature thermal decomposition is consistent with calcite, dolomite, or ankerite, (3-6 wt.%) or any combination of these phase based upon laboratory testbed experiments. Recent laboratory experiments suggest that the low temperature CO2 release was caused by a reaction between calcium carbonate and hydrated magnesium perchlorate; although, CO2 release by the oxidation of organic materials and Fe-/Mg-rich carbonates cannot be ruled out. MSL landed in Gale crater on August 5, 2012. Although numerous analog samples have been analyzed on the JSC laboratory testbeds, no SAM, CheMin, or ChemCam analyses have been acquired by MSL to date. The JSC SAM laboratory testbed consists of a thermal analyzer coupled with a MS configured to operate under total pressure (30 mbar), heating rate (35 C/min), and purge gas composition (He) analogous to the flight SAM. The CheMin and ChemCam laboratory testbeds were developed and built by inXitu, Inc. and Los Alamos National Laboratory, respectively, to acquire datasets relevant to the MSL CheMin and ChemCam flight instruments.

Ming, D. W.↗

Color Change During Thermal Degradation of Polyolefin Electric Cable Insulations

Color change of electric cable insulations used in nuclear power plants (NPPs) is a non-destructive, quick and inexpensive technique to measure degradation. Quantification of color change is facilitated by a light booth of CIE D65 illuminant, a commercial camera and open-source software ImageJ with micaToolbox plugin. Yellowness index (YI) and total color difference (?E) are calculated from calibrated photos of a white cross-linked polyethylene (XLPE) and a black ethylene-propylene rubber (EPR) based specimens aged at 110°C, 121°C, 136°C and 150°C after 1~640 days. Using the same setup and software, pixelwise ?E profile is determined for the cross-sectional photo of a white EPR specimen, where heterogeneous aging is detected.

cable aging, color analysis↗

Development of a scintillator based fast-ion loss detector for the Wendelstein 7-X stellarator

A new scintillator based fast-ion loss detector (FILD) system has been designed for the Wendelstein 7-X (W7-X) stellarator. The mechanical design of the system is presented here along with engineering analyses of the system. This includes an assessment of the structural loads which also considers electromagnetic forces calculated for possible disruption scenarios as well as a mode frequency analysis of the system. Furthermore, an analysis of the thermal characteristics of the actively cooled probe head under prescribed steady state and transient heat loads is presented. Finally, the optical relay system is described and its properties used to forward model synthetic camera signals using the FILDSIM code and based on theoretical fast-ion losses incident on the probe head calculated using the ASCOT5 code.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Active beam position stabilization of pulsed lasers for long-distance ion profile diagnostics at the Spallation Neutron Source (SNS)

A high peak-power Q-switched laser has been used to monitor the ion beam profiles in the superconducting linac at the Spallation Neutron Source (SNS). The laser beam suffers from position drift due to movement, vibration, or thermal effects on the optical components in the 250-meter long laser beam transport line. We have designed, bench-tested, and implemented a beam position stabilization system by using an Ethernet CMOS camera, computer image processing and analysis, and a piezo-driven mirror platform. The system can respond at frequencies up to 30 Hz with a high position detection accuracy. With the beam stabilization system, we have achieved a laser beam pointing stability within a range of 2 rad (horizontal) to 4 rad (vertical), corresponding to beam drifts of only 0.5 mm 1 mm at the furthest measurement station located 250 meters away from the light source.

43 PARTICLE ACCELERATORS↗

Evolution of Occator Crater on (1) Ceres

The dwarf planet Ceres (diameter 939 km) is the largest object in the main asteroid belt. Recent investigations suggest that Ceres is a thermally evolved, volatile-rich body with potential geological activity, a body which was never completely molten but possibly differentiated into a rocky core, an ice-rich mantle, and which may contain remnant internal liquid water. Thermal alteration and exogenic material infall contribute to producing a (dark) carbonaceous chondritic-like surface containing ammoniated phyllosilicates. Here we report imaging and spectroscopic analyses of Occator crater derived from the Framing Camera and the Visible and Infrared Spectrometer onboard Dawn. We found that the central bright spot (Cerealia Facula) of Occator is ∼30 Myr younger than the crater itself. The central spot is located in a central pit which contains a dome that is spectrally homogenous, exhibiting absorption features that are consistent with carbonates. Multiple radial fractures across the dome indicate an extrusive formation process. Our results lead us to conclude that the floor region was subject to past endogenic activity. Dome and bright material in its vicinity formed likely due to a long-lasting, periodic, or episodic ascent of bright material from a subsurface reservoir rich in carbonates. Originally triggered by an impact event, gases, possibly dissolved from a subsurface water/brine layer, enabled material rich in carbonates to ascend through fractures and be deposited onto the surface.

79 ASTRONOMY AND ASTROPHYSICS↗

MVACS Robotic Arm

The primary purpose of the Mars Volatiles and Climate Surveyor (MVACS) Robotic Arm is to support to the other MVACS science instruments by digging trenches in the Martian soil; acquiring and dumping soil samples into the thermal evolved gas analyzer (TEGA); positioning the Soil Temperature Probe (STP) in the soil: positioning the Robotic Arm Air Temperature Sensor (RAATS) at various heights above the surface, and positioning the Robotic Arm Camera (RAC) for taking images of the surface, trench, soil samples, magnetic targets and other objects of scientific interest within its workspace.

robotics robotic arm sampling MVACS↗

NASA Tech Briefs, September 2006

Topics covered include: Improving Thermomechanical Properties of SiC/SiC Composites; Aerogel/Particle Composites for Thermoelectric Devices; Patches for Repairing Ceramics and Ceramic- Matrix Composites; Lower-Conductivity Ceramic Materials for Thermal-Barrier Coatings; An Alternative for Emergency Preemption of Traffic Lights; Vehicle Transponder for Preemption of Traffic Lights; Automated Announcements of Approaching Emergency Vehicles; Intersection Monitor for Traffic-Light-Preemption System; Full-Duplex Digital Communication on a Single Laser Beam; Stabilizing Microwave Frequency of a Photonic Oscillator; Microwave Oscillators Based on Nonlinear WGM Resonators; Pointing Reference Scheme for Free-Space Optical Communications Systems; High-Level Performance Modeling of SAR Systems; Spectral Analysis Tool 6.2 for Windows; Multi-Platform Avionics Simulator; Silicon-Based Optical Modulator with Ferroelectric Layer; Multiplexing Transducers Based on Tunnel-Diode Oscillators; Scheduling with Automated Resolution of Conflicts; Symbolic Constraint Maintenance Grid; Discerning Trends in Performance Across Multiple Events; Magnetic Field Solver; Computing for Aiming a Spaceborne Bistatic- Radar Transmitter; 4-Vinyl-1,3-Dioxolane-2-One as an Additive for Li-Ion Cells; Probabilistic Prediction of Lifetimes of Ceramic Parts; STRANAL-PMC Version 2.0; Micromechanics and Piezo Enhancements of HyperSizer; Single-Phase Rare-Earth Oxide/Aluminum Oxide Glasses; Tilt/Tip/Piston Manipulator with Base-Mounted Actuators; Measurement of Model Noise in a Hard-Wall Wind Tunnel; Loci-STREAM Version 0.9; The Synergistic Engineering Environment; Reconfigurable Software for Controlling Formation Flying; More About the Tetrahedral Unstructured Software System; Computing Flows Using Chimera and Unstructured Grids; Avoiding Obstructions in Aiming a High-Gain Antenna; Analyzing Aeroelastic Stability of a Tilt-Rotor Aircraft; Tracking Positions and Attitudes of Mars Rovers; Stochastic Evolutionary Algorithms for Planning Robot Paths; Compressible Flow Toolbox; Rapid Aeroelastic Analysis of Blade Flutter in Turbomachines; General Flow-Solver Code for Turbomachinery Applications; Code for Multiblock CFD and Heat-Transfer Computations; Rotating-Pump Design Code; Covering a Crucible with Metal Containing Channels; Repairing Fractured Bones by Use of Bioabsorbable Composites; Kalman Filter for Calibrating a Telescope Focal Plane; Electronic Absolute Cartesian Autocollimator; Fiber-Optic Gratings for Lidar Measurements of Water Vapor; Simulating Responses of Gravitational-Wave Instrumentation; SOFTC: A Software Correlator for VLBI; Progress in Computational Simulation of Earthquakes; Database of Properties of Meteors; Computing Spacecraft Solar-Cell Damage by Charged Particles; Thermal Model of a Current-Carrying Wire in a Vacuum; Program for Analyzing Flows in a Complex Network; Program Predicts Performance of Optical Parametric Oscillators; Processing TES Level-1B Data; Automated Camera Calibration; Tracking the Martian CO2 Polar Ice Caps in Infrared Images; Processing TES Level-2 Data; SmaggIce Version 1.8; Solving the Swath Segment Selection Problem; The Spatial Standard Observer; Less-Complex Method of Classifying MPSK; Improvement in Recursive Hierarchical Segmentation of Data; Using Heaps in Recursive Hierarchical Segmentation of Data; Tool for Statistical Analysis and Display of Landing Sites; Automated Assignment of Proposals to Reviewers; Array-Pattern-Match Compiler for Opportunistic Data Analysis; Pre-Processor for Compression of Multispectral Image Data; Compressing Image Data While Limiting the Effects of Data Losses; Flight Operations Analysis Tool; Improvement in Visual Target Tracking for a Mobile Robot; Software for Simulating Air Traffic; Automated Vectorization of Decision-Based Algorithms; Grayscale Optical Correlator Workbench; "One-Stop Shopping" for Ocean Remote-Sensing and Model Data; State Analysis Database Tool; Generating CAHV and CAHVOmages with Shadows in ROAMS; Improving UDP/IP Transmission Without Increasing Congestion; FORTRAN Versions of Reformulated HFGMC Codes; Program for Editing Spacecraft Command Sequences; Flight-Tested Prototype of BEAM Software; Mission Scenario Development Workbench; Marsviewer; Tool for Analysis and Reduction of Scientific Data; ASPEN Version 3.0; Secure Display of Space-Exploration Images; Digital Front End for Wide-Band VLBI Science Receiver; Multifunctional Tanks for Spacecraft; Lightweight, Segmented, Mostly Silicon Telescope Mirror; Assistant for Analyzing Tropical-Rain-Mapping Radar Data; and Anion-Intercalating Cathodes for High-Energy- Density Cells.

Source record↗

JWST's Cryogenic Position Metrology System

The James Webb Space Telescope will undergo a full system test in the cryogenic vacuum chamber A at the Johnson Spaceflight Center in order to verify the overall performance of the combined telescope and instrument suite. This will be the largest and most extensive cryogenic test ever undertaken. Early in the test system development, it was determined that precise position measurements of the overall hardware would enhance the test results. Various concepts were considered before selecting photogrammetry for this metrology. Photogrammetry has been used in space systems for decades, however cryogenic use combined with the size and the optical/thermal sensitivity of JWST creates a unique set of implementation challenges. This paper provides an overview of the JWST photogrammetric system and mitigation strategies for three key engineering design challenges: 1) the thermal design of the viewing windows to prevent excessive heat leak and stray light to the test article 2) cost effective motors and mechanisms to provide the angle diversity required, and 3) camera-flash life and reliability sufficient for inaccessible use during the number and duration of the cryogenic tests.

Whitman, Tony L.↗

FY23 Progress Report on Viscosity and Thermal Conductivity Measurements of Molten Salts

As presented in this report, thermal conductivity and viscosity measurements were performed on key chloride pseudo-binary molten salt systems of relevance to molten salt reactor developers. Thermal conductivity measurements were conducted with a variable gap technique, in which a known heat flux is driven across a molten salt specimen and the temperature difference is measured, allowing calculation of the thermal conductivity. This is achieved by establishing a small gap between the bottom of a cylindrical inner containment, which houses electrical heating elements, and an outer containment, which houses cooling channels; the gap size can be varied by compression of a formed bellows. A new calibration scheme was developed herein, involving a correction factor to the heat flux based on He measurements at various temperatures. Furthermore, the data processing methodology was improved to minimize the impact of radiative heat transfer in the calculation of salt specimen thermal conductivity from the temperature difference measurements. Viscosity measurements were conducted with a rolling ball viscometer, in which a ball rolls some known distance in an angled tubular crucible, and the terminal velocity can be used to calculate the viscosity of the salt. The measurement can be performed in a quartz crucible, with which a standard camera can be used to track the ball, or in a metal crucible, with which x-ray radiography is required to track the ball. A new custom x-ray system was made and dedicated to the rolling ball viscometer to enable high throughput automated measurements with salts which require containment with metal. Both systems have been integrated with a ventilation stack which allows for off-gassing of radioactive material, enabling future measurements with U-bearing salts. The thermal conductivity measurements performed herein were with NaCl-KCl (44 mol% NaCl). This salt system was measured in the previous fiscal year, however the thermal conductivity values obtained were comparatively low, and so the system was remeasured with the aforementioned calibration scheme and improved post-processing techniques. The newly obtained thermal conductivity values for NaCl-KCl (44 mol% NaCl) indicate good agreement with kinetic theory and ab-initio models (within 5–10 %). The viscosity measurements performed herein were with three different compositions of NaCl-KCl: 75, 50, and 25 mol% NaCl; a new calibration scheme was applied to account for variable flow effects in the laminar regime. The results show reasonable agreement with literature (5–20 %, depending on the temperature, composition, and study); however, literature values are likely higher than true values based on pure end-member measurements performed in the comparative studies. The measurements conducted herein do show a trend such that viscosity increases with increasing NaCl concentration, which agrees well with one of two comparative studies. In general, the measurements conducted herein gives confidence in the capability to use these systems to accurately measure thermal conductivity and viscosity of actinide-bearing salts within the next fiscal year.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

CONSTRAINING THE OPTICAL EMISSION FROM THE DOUBLE PULSAR SYSTEM J0737-3039

We present the first optical observations of the unique system J0737-3039 (composed of two pulsars, hereafter PSR-A and PSR-B). Ultra-deep optical observations, performed with the High Resolution Camera of the Advanced Camera for Surveys on board the Hubble Space Telescope, could not detect any optical emission from the system down to m{sub F435W} = 27.0 and m{sub F606W} = 28.3. The estimated optical flux limits are used to constrain the three-component (two thermal and one non-thermal) model recently proposed to reproduce the XMM-Newton X-ray spectrum. They suggest the presence of a break at low energies in the non-thermal power-law component of PSR-A and are compatible with the expected blackbody emission from the PSR-B surface. The corresponding efficiency of the optical emission from PSR-A's magnetosphere would be comparable to that of other Myr-old pulsars, thus suggesting that this parameter may not dramatically evolve over a timescale of a few Myr.

79 ASTRONOMY AND ASTROPHYSICS↗

HUBBLE SPACE TELESCOPE DETECTION OF THE DOUBLE PULSAR SYSTEM J0737–3039 IN THE FAR-ULTRAVIOLET

We report on detection of the double pulsar system J0737–3039 in the far-UV with the Advanced Camera for Surveys/Solar-blind Channel detector aboard Hubble Space Telescope. We measured the energy flux F = (4.6 ± 1.0) × 10{sup –17} erg cm{sup –2} s{sup –1} in the 1250-1550 Å band, which corresponds to the extinction-corrected luminosity L ≈ 1.5 × 10{sup 28} erg s{sup –1} for the distance d = 1.1 kpc and a plausible reddening E(B – V) = 0.1. If the detected emission comes from the entire surface of one of the neutron stars with a 13 km radius, the surface blackbody temperature is in the range T ≅ (2-5) × 10{sup 5} K for a reasonable range of interstellar extinction. Such a temperature requires an internal heating mechanism to operate in old neutron stars, or, less likely, it might be explained by heating of the surface of the less energetic Pulsar B by the relativistic wind of Pulsar A. If the far-ultraviolet emission is non-thermal (e.g., produced in the magnetosphere of Pulsar A), its spectrum exhibits a break between the UV and X-rays.

79 ASTRONOMY AND ASTROPHYSICS↗

Energy-resolved neutron imaging and diffraction including grain orientation mapping using event camera technology

Time-of-flight neutron diffraction and energy-resolved imaging each provide unique perspectives into material properties. Neutron diffraction is useful for assessing microstructural parameters such as phase composition, texture, and dislocation densities, though it typically provides averaged data over the sampled volume. Energy-resolved imaging, on the other hand, offers both spatial and spectral information by detecting Bragg edges and neutron absorption resonances, which enables detailed mapping of microstructure and isotopic composition. When combined, these techniques have the potential to enrich our understanding of material behavior across different scales, enhancing our understanding of complex materials. Traditionally, these modalities are conducted on separate instruments, which is time-consuming and poses challenges for data integration. Here, we report the integration of the LumaCam, an event-mode energy-resolved neutron imaging camera with the HIPPO time-of-flight diffractometer at LANSCE. This integration enables simultaneous diffraction and imaging across the full spectrum, with analysis optimized for diffraction and Bragg-edge imaging in the thermal range (0.45–10 Å) and resonance imaging in the epithermal range (0.5–3000 eV), facilitating comprehensive multi-modal analysis. We demonstrate its capabilities through case studies, including spatial mapping of grain orientations in a steel sample and accurate thickness estimations for irregular samples including a depleted uranium cylinder and a natural silver-containing mineral specimen. The combined setup enhances real-time sample alignment and provides comprehensive data for crystal structure, texture, and isotopic composition analysis. This approach opens new possibilities for advanced applications in nuclear engineering, archaeology, and materials science.

36 MATERIALS SCIENCE↗

OBSERVATIONS OF THE OPTICAL TRANSIENT IN NGC 300 WITH AKARI/IRC: POSSIBILITIES OF ASYMMETRIC DUST FORMATION

We present the results of near-infrared (NIR) multi-epoch observations of the optical transient in the nearby galaxy NGC 300 (NGC 300-OT) at 398 and 582 days after the discovery with the Infrared Camera (IRC) on board AKARI. NIR spectra (2-5 {mu}m) of NGC 300-OT were obtained for the first time. They show no prominent emission nor absorption features, but are dominated by continuum thermal emission from the dust around NGC 300-OT. NIR images were taken in the 2.4, 3.2, and 4.1 {mu}m bands. The spectral energy distributions (SEDs) of NGC 300-OT indicate the dust temperature of 810 {+-} 14 K at 398 days and 670 {+-} 12 K at 582 days. We attribute the observed NIR emission to the thermal emission from dust grains formed in the ejecta of NGC 300-OT. The multi-epoch observations enable us to estimate the dust optical depth as {approx}>12 at 398 days and {approx}>6 at 582 days at 2.4 {mu}m by assuming an isothermal dust cloud. The observed NIR emission must be optically thick, unless the amount of dust grains increases with time. Little extinction at visible wavelengths reported in earlier observations suggests that the dust cloud around NGC 300-OT should be distributed inhomogeneously so as to not screen the radiation from the ejecta gas and the central star. The present results suggest the dust grains are not formed in a spherically symmetric geometry, but rather in a torus, a bipolar outflow, or clumpy cloudlets.

79 ASTRONOMY AND ASTROPHYSICS↗

Hardware development for the surface tension driven convection experiment aboard the USML-1 spacelab mission

The Surface Tension Driven Convection Experiment is a Space Transportation System flight experiment to study both transient and steady thermocapillary fluid flows aboard the USML-1 Spacelab mission planned for March 1992. Hardware is under development to establish the experimental conditions and perform the specified measurements, for both ground based research and the flight experiment in a Spacelab single rack. Major development areas include an infrared thermal imaging system for surface temperature measurement, a CO2 laser and control system for surface heating, and for flow visualization, a He-Ne laser and optical system in conjunction with an intensified video camera. For ground based work the components of each system were purchased or designed, and tested individually. The three systems will be interfaced with the balance of the experimental hardware and will constitute a working engineering model. A description of the three systems and examples of the component performance is given along with the plans for the development of flight hardware.

Pline, A. D.↗

Hardware development for the Surface Tension Driven Convection Experiment aboard the USML-1 Spacelab mission

The Surface Tension Driven Convection Experiment is a Space Transportation System flight experiment to study both transient and steady thermocapillary fluid flows aboard the USML-1 Spacelab mission planned for March 1992. Hardware is under development to establish the experimental conditions and perform the specified measurements, for both ground based research and the flight experiment in a Spacelab single rack. Major development areas include an infrared thermal imaging system for surface temperature measurement, a CO2 laser and control system for surface heating, and for flow visualization, a He-Ne laser and optical system in conjunction with an intensified video camera. For ground based work the components of each system were purchased or designed, and tested individually. The three systems will be interfaced with the balance of the experimental hardware and will constitute a working engineering model. A description of the three systems and examples of the component performance is given along with the plans for the development of flight hardware.

Pline, A. D.↗