Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “techniques: image processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Time resolved in-situ multi-contrast X-ray imaging of melting in metals

In this work, the application of a time resolved multi-contrast beam tracking technique to the investigation of the melting and solidification process in metals is presented. The use of such a technique allows retrieval of three contrast channels, transmission, refraction and dark-field, with millisecond time resolution. We investigated different melting conditions to characterize, at a proof-of-concept level, the features visible in each of the contrast channels. We found that the phase contrast channel provides a superior visibility of the density variations, allowing the liquid metal pool to be clearly distinguished. Refraction and dark-field were found to highlight surface roughness formed during solidification. This work demonstrates that the availability of the additional contrast channels provided by multi-contrast X-ray imaging delivers additional information, also when imaging high atomic number specimens with a significant absorption.

36 MATERIALS SCIENCE↗

Megahertz-rate shock-wave distortion cancellation via phase conjugate digital in-line holography

Abstract Holography is a powerful tool for three-dimensional imaging. However, in explosive, supersonic, hypersonic, cavitating, or ionizing environments, shock-waves and density gradients impart phase distortions that obscure objects in the field-of-view. Capturing time-resolved information in these environments also requires ultra-high-speed acquisition. To reduce phase distortions and increase imaging rates, we introduce an ultra-high-speed phase conjugate digital in-line holography (PCDIH) technique. In this concept, a coherent beam passes through the shock-wave distortion, reflects off a phase conjugate mirror, and propagates back through the shock-wave, thereby minimizing imaging distortions from phase delays. By implementing the method using a pulse-burst laser setup at up to 5 million-frames-per-second, time-resolved holograms of ultra-fast events are now possible. This technique is applied for holographic imaging through laser-spark plasma-generated shock-waves and to enable three-dimensional tracking of explosively generated hypersonic fragments. Simulations further advance our understanding of physical processes and experiments demonstrate ultra-high-speed PCDIH techniques for capturing dynamics.

Science & Technology - Other Topics↗

HIGH DYNAMIC RANGE IMAGES OF THE SOLAR CORONA BETWEEN 150 AND 450 MHz

We present radio images of the quiet Sun obtained with the Nancay Radioheliograph between 150 and 450 MHz, using the latest improvements in the instrument and in the data processing techniques. We emphasize new aspects of the corona observable in this frequency range, particularly the prominence of coronal holes, and discuss implications for future studies.

99 GENERAL AND MISCELLANEOUS↗

Electro-Hydraulic Forming of Sheet Metals: Free-forming vs. Conical-die Forming

This work builds upon our recent advances in quantifying high-rate deformation behavior of sheet metals, during electro-hydraulic forming (EHF), using high-speed imaging and digital image correlation techniques. Following recent publication of an earlier manuscript, resulting from this project, in the Journal of Materials Processing Technology, this manuscript further details our results and compares forming behavior when the process is carried out inside an open-die or a conical die. It is anticipated that quantitative information of the sheet deformation history, made possible by the experimental technique developed in this work, will improve our understanding on the roles of strain-rate and sheet-die interactions in enhancing the sheet metal formability during high-rate forming. This knowledge will be beneficial to the automotive industry and enable them to fabricate light-weight sheet parts out of Al and advanced high strength steels.

36 MATERIALS SCIENCE↗

3D nanolithography with metalens arrays and spatially adaptive illumination

The growing demand for advanced materials, miniaturized devices and integrated microsystems calls for the reliable fabrication of complex, multiscale, three-dimensional (3D) architectures, a need increasingly addressed through light-based and laser-based processes. However, owing to the field-of-view (FOV) limitations of conventional imaging optics, existing 3D laser nanofabrication techniques face fundamental challenges in throughput, proximity error and stitching defects on the path to scaling. Here, in this study, we present a scalable 3D nanofabrication platform that uses a metalens-generated focal spot array to parallelize two-photon lithography (TPL) beyond centimetre-scale write field areas. Metalenses are ideally suited for producing submicron-scale focal spots for high-throughput nanolithography, as they uniquely feature large numerical apertures (NAs), immersion media compatibility and large-scale manufacturability. We experimentally demonstrate a printing system that uses a 12-cm 2 metalens array to produce more than 120,000 cooperative focal spots, corresponding to a throughput exceeding 10 8 voxels s −1 . By programmatically patterning the focal spot array using a spatial light modulator (SLM), an adaptive parallel printing strategy is developed for precise greyscale linewidth modulation and choreographed printing of semiperiodic and fully aperiodic 3D geometries. We demonstrate parallel printing of replicated microstructures (>50 M microparticles per day), centimetre-scale 3D architectures with feature sizes down to 113 nm, and photonic and mechanical metamaterials. This work demonstrates the potential of 3D nanolithography towards wafer-scale production, showing how TPL could be used at scale for applications in microelectronics, biomedicine, quantum technology and high-energy laser targets.

Materials science↗

Recent Advances and Future Advances in Time-of-Flight PET

Simple theory predicts that the statistical noise variance in PET can be reduced by an order of magnitude by using time-of-flight (TOF) information. This reduction can be obtained by improving the coincidence timing resolution, and so would be achievable in clinical, whole body studies using with PET systems that differ little from existing cameras. The potential impact of this development is large, especially for oncology studies in large patients, where it is sorely needed. TOF PET was extensively studied in the 1980's but died away in the 1990's, as it was impossible to reliably achieve sufficient timing resolution without sacrificing other important PET performance aspects, such as spatial resolution and efficiency. Recent advances in technology (scintillators, photodetectors, and high speed electronics) have renewed interest in TOF PET, which is experiencing a rebirth. However, there is still much to be done, both in instrumentation development and evaluating the true benefits of TOF in modern clinical PET. This paper looks at what has been accomplished and what needs to be done before time-of-flight PET can reach its full potential.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

NEW DEVELOPMENTS IN DIGITAL X-RAY TECHNIQUES: A SIMULATION TOOL FOR SCATTERING IMAGING

This paper focus mainly on a simulation tool used to compute X-ray imaging technique and the last developments with the calculation of the scattering. It allows evaluating the scattered contribution on a transmission detector but also simulating scattering technique as Compton or Rayleigh tomography. A major interest of the Compton scattering technique is that the experimental device is located on one side of the object, and thus, an image can be acquired even if we can not access to the other side of the object.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast Tomography: A Study Of Image Quality

We present tomographic slices of fast X-ray computed microtomography, focusing on one hand on the comparison of scans with identical scan time but varying experimental settings, on the other hand on comparing scans with total scan times that are two orders of magnitude apart. We show that streaks in the Fourier-space of the transformed images appear when the number of projections is reduced. These streaks exhibit spacing by the same angle as the one that is covered by the sample during the exposure time of one projection. Further a method for the estimation of information loss in fast scans is presented.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Image Quality and Radiation Dose Assessment of a Digital Mammography System

Image quality and radiation dose of a direct amorphous selenium digital mammography system were considered in terms of contrast to noise ratio (CNR) and average glandular dose (AGD). They were measured for various qualities and breast phantom thicknesses with different types of breast tissue composition to determine optimal radiation quality and dose. Three sets of breast tissue equivalent slabs (30%:70%, 50%:50% and 70%:30% glandular-adipose) with thickness of 2 cm to 7 cm and 0.2 mm aluminum foil were used to provide certain CNR. Two different combinations of anode/ilter material and a wide range of tube voltages were employed for each phantom thickness. Phantom images with grid were acquired using automatic exposure control (AEC) mode for each thickness. Phantom images without grid were also obtained in manual exposure mode by selecting the same anode/filter combination and kVp as the image obtained with grid at the same thickness, but varying mAs of 10 to 200 mAs. Optimization indicated that relatively high energy beam qualities should be used with a greater dose to compensate for lower energy x-rays. The results also indicate that current AEC setting for a fixed detector is not optimal.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimum exposure conditions for computed radiography depending on fixed pattern noise and efficiency of imaging plate-scanner systems

The presently active standards on Computed Radiography (CR) need a major revision. It was observed by many users that the image quality for class B of EN 14784-2 is not achievable under the same exposure conditions as used for film exposure. A mathematical model was developed and tested, which allows the calculation of the image quality, proven by image quality indicators (IQI), depending on the fixed pattern noise and the efficiency of the used imaging plate (IP) scanner system. All tested IP scanner systems provide a fixed correlation between the measured signal/noise ratio (SNR) and the grey values in the digital images. The maximum achievable SNR{sub max} depends on the fixed pattern noise of the plate (high dose limit). Depending on the exposure dose an optimum visibility of IQIs can be predicted by calculation and measured considering the attenuation coefficient for calculation of the contrast/noise ratio (CNR). The diameter of the just visible wire is proportional to 1/sqrt(CNR). The optimum tube voltage for best visibility of IQIs and maximum CNR depend on the exposure dose. The optimum tube voltage for best visibility is achieved only at exposures with high dose. A dose dependant optimal tube voltage was not observed for film radiography.

07 ISOTOPE AND RADIATION SOURCES↗

Three-dimensional modeling of a plasma in a strong azimuthal magnetic field

Three-dimensional magnetohydrodynamic (MHD) simulations are able to model the generation of disc-shaped plasma, driven by laser ablation from a current carrying rod in a pulsed-power machine producing azimuthal magnetic fields of 2–3 MG. The plasma at such extreme conditions is unique in that the parameter space for the plasma β and Hall parameter χ transition from below unity to greater than unity at different stages of the plasma generation. In simulations, the formation of the plasma disc in the azimuthal direction, is driven by heat flux from the laser spot and depends on the set of transport coefficients used in simulations. The most recent set of transport coefficients leads to the formation of plasma ejecta at the back end of the rod, that qualitatively matches experiments. Specifically, the cross-gradient Nernst effect, which twists magnetic field, is shown to have a large effect on the shape of the back end ejecta. In the direction along the axis of the rod there is propagation of perturbations from the disc as observed in experiments. In simulations the period of temperature perturbations is in good agreement with experimental results. Furthermore, an instability due to coupling of heat flux and the magnetic field advection provides a possible explanation for perturbation growth along the axis of the rod, and the instability growth rate is consistent with experimental results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Imaging Modes for Ground Penetrating Radar and Their Relation to Detection Performance

The focus of this paper is an empirical study conducted to determine how imaging modes for ground penetrating radar (GPR) affect buried object detection performance. GPR data was collected repeatedly over lanes whose buried objects were mostly non-metallic. This data was collected and processed with a GPR antenna array, system hardware, and processing software developed by the authors and their colleagues. The system enables GPR data to be collected, imaged, and processed in real-time on a moving vehicle. The images are focused by applying multistatic and synthetic aperture imaging techniques either separately or jointly to signal scans acquired by the GPR antenna array. An image-based detection statistic derived from the ratio of buried object energy in the foreground to energy of soil in the background is proposed. Detection – false alarm performance improved significantly when the detection algorithm was applied to focused multistatic synthetic aperture radar (SAR) images rather than to unfocused GPR signal scans.

47 OTHER INSTRUMENTATION↗

Automating High-Precision X-Ray and Neutron Imaging Applications with Robotics

Los Alamos National Laboratory and the University of Texas at Austin recently implemented a robotically controlled nondestructive testing (NDT) system for X-ray and neutron imaging. This system is intended to address the need for accurate measurements for a variety of parts and, be able to track measurement geometry at every imaging location, and is designed for high-throughput applications. This system was deployed in a beam port at a nuclear research reactor and in an operational inspection X-ray bay. The nuclear research reactor system consisted of a precision industrial seven-axis robot, 1.1-MW TRIGA research reactor, and a scintillator-mirror-camera-based imaging system. The X-ray bay system incorporated the same robot, a 225-keV microfocus X-ray source, and a custom flat panel digital detector. The robotic positioning arm is programmable and allows imaging in multiple configurations, including planar, cylindrical, as well as other user defined geometries that provide enhanced engineering evaluation capability. The imaging acquisition device is coupled with the robot for automated image acquisition. The robot can achieve target positional repeatability within 17 μm in the 3-D space. Flexible automation with nondestructive imaging saves costs, reduces dosage, adds imaging techniques, and achieves better quality results in less time. Specifics regarding the robotic system and imaging acquisition and evaluation processes are presented. In conclusion, this paper reviews the comprehensive testing and system evaluation to affirm the feasibility of robotic NDT, presents the system configuration, and reviews results for both X-ray and neutron radiography imaging applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Physical and mechanical metallurgy of zirconium alloys for nuclear applications: a multi-scale computational study

In the post-Fukushima world, the stability of materials under extreme conditions is an important issue for the safety of nuclear reactors. Because the nuclear industry is going to continue using advanced zirconium cladding materials in the foreseeable future, it become critical to gain fundamental understanding of the several interconnected problems. First, what are the thermodynamic and kinetic factors affecting the oxidation and hydrogen pick-up by these materials at normal, off-normal conditions, and in long-term storage? Secondly, what protective coatings (if any) could be used in order to gain extremely valuable time at off-normal conditions, e.g., when temperature exceeds the critical value of 2200°F? Thirdly, the kinetics of oxidation of such protective coating or braiding needs to be quantified. Lastly, even if some degree of success is achieved along this path, it is absolutely critical to have automated inspection algorithms allowing identifying defects of cladding as soon as possible. This work strives to explore these interconnected factors from the most advanced computational perspective, utilizing such modern techniques as first-principles atomistic simulations, computational thermodynamics of materials, diffusion modeling, and the morphological algorithms of image processing for defect identification. Consequently, it consists of the four parts dealing with these four problem areas preceded by the introduction and formulation of the studied problems. In the 1st part an effort was made to employ computational thermodynamics and ab initio calculations to shed light upon the different stages of oxidation of ziraloys (2 and 4), the role of microstructure optimization in increasing their thermal stability, and the process of hydrogen pick-up, both in normal working conditions and in long-term storage. The 2nd part deals with the need to understand the influence and respective roles of the two different plasticity mechanisms in Zr nuclear alloys: twinning (at low T) and crystallographic slip (higher T’s). For that goal, a description of the advanced plasticity model is outlined featuring the non-associated flow rule in hcp materials including Zr. The 3rd part describes the kinetic theory of oxidation of the several materials considered to be perspective coating materials for Zr alloys: SiC and ZrSiO 4 . In the 4th part novel and advanced projectional algorithms for defect identification in zircaloy coatings are described. In so doing, the author capitalized on some 12 years of his applied industrial research in this area. Our conclusions and recommendations are presented in the 5th part of this work, along with the list of used literature and the scripts for atomistic, thermodynamic, kinetic, and morphological computations.

36 MATERIALS SCIENCE↗

Project 1640 Observations of Brown Dwarf GJ 758 B: Near-infrared Spectrum and Atmospheric Modeling

The nearby Sun-like star GJ 758 hosts a cold substellar companion, GJ 758 B, at a projected separation of ≲30 au, previously detected in high-contrast multi-band photometric observations. In order to better constrain the companion’s physical characteristics, we acquired the first low-resolution (R ∼ 50) near-infrared spectrum of it using the high-contrast hyperspectral imaging instrument Project 1640 on Palomar Observatory’s 5 m Hale telescope. We obtained simultaneous images in 32 wavelength channels covering the Y, J, and H bands (∼952–1770 nm), and used data processing techniques based on principal component analysis to efficiently subtract chromatic background speckle-noise. GJ 758 B was detected in four epochs during 2013 and 2014. Basic astrometric measurements confirm its apparent northwest trajectory relative to the primary star, with no clear signs of orbital curvature. Spectra of SpeX/IRTF observed T dwarfs were compared to the combined spectrum of GJ 758 B, with χ {sup 2} minimization suggesting a best fit for spectral type T7.0 ± 1.0, but with a shallow minimum over T5–T8. Fitting of synthetic spectra from the BT-Settl13 model atmospheres gives an effective temperature T {sub eff} = 741 ± 25 K and surface gravity logg=4.3±0.5 dex (cgs). Our derived best-fit spectral type and effective temperature from modeling of the low-resolution spectrum suggest a slightly earlier and hotter companion than previous findings from photometric data, but do not rule out current results, and confirm GJ 758 B as one of the coolest sub-stellar companions to a Sun-like star to date.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of NDE/NDT Tools for High-Volume & High-Speed Inspection of CFRP Structures in Automotive Manufacturing

Main advantages of the air-coupled ultrasound testing (ACUT) and electromagnetic testing (EMT) techniques for NDE of CFRP composites were non-contact sensing, scalability for high-speed inspection, cost-effectiveness, and non-hazardous operation. Despite these advantages, no systems that would satisfy the project requirements were commercially available. Hence, one of the major efforts of the Michigan State University (MSU) team at the initial stage of the project was to close this technological gap by developing, optimizing, and validating array sensors that would provide sufficient sensitivity, spatial coverage, and resolution for robust defect detection. Optimization of the ACUT and EMT sensor designs was performed using experimentally validated finite element models. Initial experiments using array probes were conducted on relatively flat CFRP samples. In parallel, the MSU team designed and assembled a portable platform with two robotic arms. The robots were equipped with newly designed sensors that enabled high-speed NDE of curved CFRP parts. Presently, the developed robotic platform can be used as a demo/template NDE system, which is easily adaptable to manufacturing environments and in-line NDE. The ACUT NDE system developed by the MSU team used a high-power 4-channel pulser receiver for parallel data acquisition. The array probes were designed by stacking commercially available ACUT transducers, which operated in the frequency range between 100 kHz and 500 kHz. MSU optimized the excitation procedure and developed wave focusing cones so as to reduce the crosstalk between the transducers and to provide higher pulse repletion frequency (PRF). The through-transmission (TT) and single-side access (SSA) inspection modes were successfully implemented. In the TT-ACUT, structural defects in CFRP were detected by passing ultrasonic waves through the test part. Hence, the ACUT transmitters and receivers needed to be placed on the opposite sides of the test part. In the SSA-ACUT, guided waves (GW) were excited in the test part using the transmitters and were sensed by the receivers from the same side. Multi-channel TT-ACUT and SSA-ACUT provided high-speed NDE, and were successfully validated on CFRP test samples with interlaminar delaminations and other embedded defects The EM techniques developed by the MSU team included: 1) eddy current testing (ECT), 2) capacitive imaging (CI) and hybrid dual-mode imaging. In ECT, structural damage was detected in CFRP using coils sensor arrays. In ECT, the excitation magnetic field is generated by passing an alternating current through a coil, which is placed above the test sample. The excitation field penetrates the conductive sample and induces the eddy currents in its transect. In turn, the eddy currents generate the reaction field, which affects the total field sensed by a coil. Hence, the presence of structural flaws will alter the eddy current flow and the picked-up signal. ECT is mostly sensitive to local changes of the electric conductivity of the test sample, and CFRPs are mostly conductive in the direction of carbon fibers. Hence, ECT was well suited for the detection of fiber damage/fiber irregularities. The MSU team developed printed circuit boards (PCB) with coil sensor arrays optimized for NDE of CFRP. Unlike most commercial probes designed for ECT of metallic structures, the MSU array probes were designed for operation in [1-10] MHz frequency range, which was optimal for low-conductive CFRP. Multiple sensing topologies (coil groups excitation/sensing arrangements) were implemented and successfully validated. Capacitive Imaging (CI) technique developed by MSU was complementary to ECT. In contrast to ECT, which was sensitive to local changes of the electrical conductivity, the CI was sensitive to local changes of the dielectric constant. Therefore, CI could provide information about matrix damage/matrix irregularities in CFRP. The MSU CI sensor arrays were made of multiple circular or rectangular open-plate capacitors printed on PCB. Sensors of this type are not commercially available. In addition to ECT and CI, the MSU team developed a hybrid (dual-mode) inductive/capacitive measurement technique that synergistically combined the benefits of inductive and capacitive sensing for rapid NDE of fiber reinforced polymer (FRP) composite structures. Fiber damage and fiber irregularities in FRPs were detected by configuring hybrid sensors as coil sensors. Similarly, matrix damage, matrix irregularities and interlaminar delaminations were detected by configuring hybrid sensors as capacitive sensors. ECT and CI were performed sequentially by means of electronic switching. Hence, eliminating the need for mounting two separate sensor arrays on the probe. Portable robotic platform was developed by MSU for multi-technique high-speed NDE of CFRP test parts. The platform had two 6-axis robots, which enabled inspection of curved parts in approximately a 6×6×6 ft 3 active scan area. On the software side, the MSU team integrated scripts for NDE hardware control with scripts for robot motion control. MSU also implemented automated path planning for the robots, reconstruction of part’s surfaces via stereovision, 3D rendering of inspection data, and image processing algorithms for enhanced defect detection. Automotive composite parts manufactured by Plasan Composites from Phase I were used to validate the ACUT and EMT techniques on representative testbeds. Among those parts were three X-braces for a Dodge Viper, one composite calibration plaque with known defects at known locations, and four other test sections, including sections from a front splitter, a corner section from a composite hood, and a high-pressure RTM panel made using non crimp fabric. Other test samples included CFRP and GFRP calibration plates with fiber/matrix defects fabricated at MSU/CVRC.

36 MATERIALS SCIENCE↗

Preparation of Single Cells for Imaging Mass Spectrometry

Characterizing chemical changes within single cells is important for determining fundamental mechanisms of biological processes that will lead to new biological insights and improved disease understanding. Imaging biological systems with mass spectrometry (MS) has gained popularity in recent years as a method for creating precise chemical maps of biological samples. In order to obtain high-quality mass spectral images that provide relevant molecular information about individual cells, samples must be prepared so that salts and other cell-culture components are removed from the cell surface and the cell contents are rendered accessible to the desorption beam. We have designed a cellular preparation protocol for imaging MS that preserves the cellular contents for investigation and removes the majority of the interfering species from the extracellular matrix. Using this method, we obtain excellent imaging results and reproducibility in three diverse cell types: MCF7 human breast cancer cells, Madin-Darby canine kidney (MDCK) cells, and NIH/3T3 mouse fibroblasts. This preparation technique allows routine imaging MS analysis of cultured cells, allowing for any number of experiments aimed at furthering scientific understanding of molecular processes within individual cells.

59 BASIC BIOLOGICAL SCIENCES↗

Multi-resolution 3D visualization of the early stages of cellular uptake of peptide-coated nanoparticles

A detailed understanding of the cellular uptake process is essential to the development of cellular delivery strategies and to the study of viral trafficking. However, visualization of the entire process, encompassing the fast dynamics (local to the freely diffusing nanoparticle) as well the state of the larger-scale cellular environment, remains challenging. Here, we introduce a three-dimensional multi-resolution method to capture, in real time, the transient events leading to cellular binding and uptake of peptide (HIV1-Tat)-modified nanoparticles. Applying this new method to observe the landing of nanoparticles on the cellular contour in three dimensions revealed long-range deceleration of the delivery particle, possibly due to interactions with cellular receptors. Furthermore, by using the nanoparticle as a nanoscale ‘dynamics pen’, we discovered an unexpected correlation between small membrane terrain structures and local nanoparticle dynamics. This approach could help to reveal the hidden mechanistic steps in a variety of multiscale processes.

77 NANOSCIENCE AND NANOTECHNOLOGY↗