Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “tantalum”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

TaZr_BCC_SolidSolution_128atoms_VASP6

We performed density functional theory (DFT) calculations for body-centered-cubic (BCC) structures with 128 lattices sites of solid solution binary alloys tantalum-zirconium (Ta-Zr). The electronic structures of alloys have been calculated using Vienna Ab initio Simulation Package (VASP). Within this package the DFT approach is used to reduce many-body Schrodinger equation to set of single particle Kohn-Sham (KS) equations. The generalized electronic exchange-correlation functional is described by generalized gradient approximation with the Perdew-Burke-Ernzerhof parametrization. The electron-ion interactions is described by pseudopotentials developed within the plane-wave basis projector augmented-wave (PAW) approach \cite{PAW}. These pseudopotentials are available at the VASP portal (http://cms.mpi.univie.ac.at/vasp/). Our calculations have been run with the pseudopotentials treating s and p semi-core states as valence in case for the elements Ta and Zr. The electronic densities and potentials are expanded over plane-waves with energy cutoff of 350 eV. 2x2x2 k-mesh and normal precision were used. The alloys were modeled by supercell containing 128 randomly distributed atoms. At initial step the atoms occupy perfect bcc lattice cites. This initial structure was optimized until energy changes less than 1e-6 eV, while forces acting on atoms don't exceed 1e-2 eV/angstrom. The electron-ion interaction is described by PAW pseudopotentials. The calculations have been collected by sampling chemical compositions across the entire compositional range. The chemical compositions have been sampled by progressively changing the number of atoms per constituent by 4. For each chemical composition of binaries and ternaries, the first-principle calculations have been run for 100 randomized arrangements of the constituents on the BCC lattice sites. We collected data for a total of 3,100 randomized atomic structures over 31 chemical compositions. The calculations have been collected on NERSC-Perlmutter and OLCF-Summit using the VASP 6.3.2. The VASP calculations for every atomic structure have been performed in 2 main steps: 1. Starting from an ideal body-centered-cubic (BCC) structure, geometry optimization with low precision has been executed to perform a preliminary optimization of the atomic structure. The output for this calculations is available in the files 0.CONTCAR, 0.OUTCAR, rlx1.out. 2. Using the atomic structure resulting from the preliminary geometry optimization, a second geometry optimization has been performed using normal precision. The output for this calculations is available in the files CONTCAR, OUTCAR, rlx2.out, vaspout.h5, and vasprun.xml. Cases 1-10 have been run without generating the file 'vaspout.h5'. Every chemical composition sampled across the composition range in the dataset has its own directory. The convention used to name the directories for binary alloys is AXBY, where A and B refer to the constituents, whereas X and Y are positive integers that represent the number of atoms for each constituent and their values still sum up to 128. Each atomic structure associated with a specific chemical composition has its own sub-directory within the directory of the corresponding chemical composition. The sub-directories for each atomic structure for each chemical composition are named 'case-*', where * is a positive integer that spans all the values from 1 through 100, extremes included. The files contained in each sub-directory 'case-*' for each atomic structure are as follows: FILES contained in each subdirectory with name "case-N" where N ranges between 11 and 80, extremes included: 1. INCAR: input file that contains various parameters and settings for controlling the behavior of the electronic structure calculations 2. KPOINTS: input file that specifies the Bloch vectors (k points) used to sample the Brillouin zone 3. 0.POSCAR: input file that defines the atomic structure of a system 4. 0.CONTCAR: output file that provides the atomic positions and cell parameters after the first geometry optimization has been run with the precision variable set to PREC=Low in the INCAR file 5. 0.OUTCAR: output file that contains detailed information about the progress of a calculation after the first geometry optimization has been run with the precision variable set to PREC=Low in the INCAR file 6. rlx1.out: file with diagnostic information about the execution of the first geometry optimization with precision variable set to PREC=Low in the INCAR file 7. POSCAR: input file that defines the atomic structure of a system after the first geometry optimization has been run at low precision. This represents the input for the second geometry optimization run with the precision variable set to PREC=Normal in the INCAR file 8. CONTCAR: output file that provides the atomic positions and cell parameters after the second geometry optimization has been run with the precision variable set to PREC=Normal in the INCAR file 9. OUTCAR: output file that contains detailed information about the progress of a calculation after the second geometry optimization has been run with the precision variable set to PREC=Normal in the INCAR file 10. rlx2.out: file with diagnostic information about the execution of the second geometry optimization with precision variable set to PREC=Normal in the INCAR file 11. vaspout.h5: hierarchical HDF5 file containing the inputs and outputs of a VASP calculation. To analyze the data in this file we recommend using py4vasp. This file is only produced if the VASP version used is compiled with HDF5 support 12. vasprun.xml: contains similar information to OUTCAR, but in an xml format. 13. CHGCAR: contains the charge density data of a system. This data is crucial for analyzing electronic structures, calculating electrostatic potential, and studying the distribution of charge in a crystal or molecular system FILES contained in each subdirectory with name "case-N" where N ranges between 1 and 10 and between 81 and 100, extremes included: 1. INCAR: input file that contains various parameters and settings for controlling the behavior of the electronic structure calculations 2. KPOINTS: input file that specifies the Bloch vectors (k points) used to sample the Brillouin zone 3. {ID}.POSCAR: input file that defines the atomic structure of a system at the beginning of ID execution of geometry optimization with PREC=LOW 4. {ID}.CONTCAR: output file that provides the atomic positions and cell parameters at the end of ID execution of geometry optimization with PREC=LOW in the INCAR file 5. {ID}.OUTCAR: output file that contains detailed information about the progress of a calculation after the ID execution of geometry optimization that has been run with the precision variable set to PREC=Low in the INCAR file 6. rlx1.{ID}.out: file with diagnostic information about the execution of the ID execution of the geometry optimization with precision variable set to PREC=Low in the INCAR file 7. N{ID}.POSCAR: input file that defines the atomic structure of a system after the geometry optimization run at low precision. This represents the input for the ID execution of the second geometry optimization run with the precision variable set to PREC=Normal in the INCAR file 8. N{ID}.CONTCAR: output file that provides the atomic positions and cell parameters after the ID execution of the geometry optimization run with the precision variable set to PREC=Normal in the INCAR file 9. N{ID}.OUTCAR: output file that contains detailed information about the progress of a calculation after the ID execution of the geometry optimization run with the precision variable set to PREC=Normal in the INCAR file 10. rlx2.{ID}.out: file with diagnostic information about the ID execution of geometry optimization with precision variable set to PREC=Normal in the INCAR file 11. vaspout.h5: hierarchical HDF5 file containing the inputs and outputs of a VASP calculation. To analyze the data in this file we recommend using py4vasp. This file is only produced if the VASP version used is compiled with HDF5 support 12. vasprun.xml: contains similar information to OUTCAR, but in an xml format. 13. CHGCAR: contains the charge density data of a system. This data is crucial for analyzing electronic structures, calculating electrostatic potential, and studying the distribution of charge in a crystal or molecular system This research is sponsored by the Artificial Intelligence Initiative as part of the Laboratory Directed Research and Development (LDRD) Program of Oak Ridge National Laboratory, managed by UT-Battelle, LLC, for the US Department of Energy under contract DE-AC05-00OR22725. This work used resources of the Oak Ridge Leadership Computing Facility, which is supported by the Office of Science of the U.S. Department of Energy under Contract No. DE-AC05-00OR22725, under Directorate Discretionary awards MAT025 (Materials Science) and LRN026 (Machine Learning), and INCITE award MAT201. This work also used resources of the National Energy Research Scientific Computing Center, which is supported by the Office of Science of the U.S. Department of Energy under Contract No. DE-AC02-05CH11231, under award ERCAP0025216. REFERENCES (1) Kresse, G. & Hafner, J. Ab initio molecular dynamics for liquid metals. Phys. review B 47, 558 (1993). (2) Kresse, G. & Hafner, J. Ab initio molecular-dynamics simulation of the liquid-metal–amorphous-semiconductor transition in germanium. Phys. Rev. B 49, 14251 (1994) (3) Kresse, G. & Furthmüller, J. Efficiency of ab-initio total energy calculations for metals and semiconductors using a plane-wave basis set. Comput. materials science 6, 15–50 (1996) (4) Kresse, G. & Furthmüller, J. Efficient iterative schemes for ab initio total-energy calculations using a plane-wave basis set. Phys. review B 54, 11169 (1996) (5) Kresse, G. & Joubert, D. From ultrasoft pseudopotentials to the projector augmented-wave method. Phys. review b 59, 1758 (1999)

36 MATERIALS SCIENCE↗

TaTi_BCC_SolidSolution_128atoms_VASP6

We performed density functional theory (DFT) calculations for body-centered-cubic (BCC) structures with 128 lattices sites of solid solution binary alloys tantalum-titanium (Ta-Ti). The electronic structures of alloys have been calculated using Vienna Ab initio Simulation Package (VASP). Within this package the DFT approach is used to reduce many-body Schrodinger equation to set of single particle Kohn-Sham (KS) equations. The generalized electronic exchange-correlation functional is described by generalized gradient approximation with the Perdew-Burke-Ernzerhof parametrization. The electron-ion interactions is described by pseudopotentials developed within the plane-wave basis projector augmented-wave (PAW) approach. These pseudopotentials are available at the VASP portal (http://cms.mpi.univie.ac.at/vasp/). Our calculations have been run with the pseudopotentials treating s and p semi-core states as valence in case for the elements Hf and Nb. The electronic densities and potentials are expanded over plane-waves with energy cutoff of 350 eV. 2x2x2 k-mesh and normal precision were used. The alloys were modeled by supercell containing 128 randomly distributed atoms. At initial step the atoms occupy perfect bcc lattice cites. This initial structure was optimized until energy changes less than 1e-6 eV, while forces acting on atoms don't exceed 1e-2 eV/angstrom. The electron-ion interaction is described by PAW pseudopotentials. The calculations have been collected by sampling chemical compositions across the entire compositional range. The chemical compositions have been sampled by progressively changing the number of atoms per constituent by 4. For each chemical composition of binaries and ternaries, the first-principle calculations have been run for 100 randomized arrangements of the constituents on the BCC lattice sites. We collected data for a total of 3,100 randomized atomic structures over 31 chemical compositions. The calculations have been collected on Air Force HPC11 cluster using the VASP 6.5.1. Additional methodology and file structure information is available in the dataset README.txt file.

36 MATERIALS SCIENCE↗

Decay Dose Shielding Analysis with Hybrid Unstructured Mesh/Constructive Solid Geometry Monte Carlo Calculation and ADVANTG Acceleration

The Oak Ridge National Laboratory (ORNL) Second Target Station (STS) neutron production facility is an accelerator driven pulsed neutron source that is currently being actively developed at ORNL. The neutrons are produced by proton-induced spallation reactions. A proton beam of 700 kW power is delivered to a spallation target in short, less than 1 µs long pulses, with 15 Hz repetition rate. The spallation target of ORNL STS is a rotating water-cooled tungsten target with tantalum cladding housed in a stainless-steel shroud. It is divided into 21 segments. These segments become highly activated due to spallation reactions or nuclei transmutation by the emitted neutrons. The radioactive nuclides continue to decay after ceasing operation. The decay dose rates generated from the target segments once they are removed from their operational location within the core vessel must be accurately quantified to determine the shielding configurations of remote handling tools and transport casks and to aid in planning maintenance events. To determine the shielding configurations needed for an activated target segment after ceasing operation, both the hybrid unstructured mesh (UM)/constructive solid geometry (CSG) approach that was previously utilized for STS analyses [1] and the ADVANTG code [2] were used. Even though the ADVANTG code does not include UM capability, the utilization of its advanced variance reduction technique was crucial to accelerate the extremely difficult final photon transport calculation in this analysis. This paper also describes the procedures taken to mitigate the convergence issues that occur when ADVANTG uses a source definition that does not match the source of the final Monte Carlo (MC) calculation. These convergence issues often occur because of inconsistencies between source and transport biasing parameters.

Ibrahim, Ahmad↗

Degradation of Ta 2 O 5 / SiO 2 dielectric cavity mirrors in ultra-high vacuum

In order for optical cavities to enable strong light-matter interactions for quantum metrology, networking, and scalability in quantum computing systems, their mirrors must have minimal losses. However, high-finesse dielectric cavity mirrors can degrade in ultra-high vacuum (UHV), increasing the challenges of upgrading to cavity-coupled quantum systems. We observe the optical degradation of high-finesse dielectric optical cavity mirrors after high-temperature UHV bake in the form of a substantial increase in surface roughness. We provide an explanation of the degradation through atomic force microscopy (AFM), X-ray fluorescence (XRF), selective wet etching, and optical measurements. We find the degradation is explained by oxygen reduction in Ta 2 O 5 followed by growth of tantalum sub-oxide defects with height to width aspect ratios near ten. We discuss the dependence of mirror loss on surface roughness and finally give recommendations to avoid degradation to allow for quick adoption of cavity-coupled systems.

Optics↗

Materials Data on Ta2O by Materials Project

Ta2O is alpha Po structured and crystallizes in the cubic I-43m space group. The structure is zero-dimensional and consists of six tantalum molecules and two Ta5O4 clusters. In each Ta5O4 cluster, there are two inequivalent Ta sites. In the first Ta site, Ta is bonded in a distorted single-bond geometry to one O atom. The Ta–O bond length is 1.84 Å. In the second Ta site, Ta is bonded in a tetrahedral geometry to four equivalent O atoms. All Ta–O bond lengths are 1.88 Å. O is bonded in a distorted linear geometry to two Ta atoms.

36 MATERIALS SCIENCE↗

Materials Data on Ta2Se17Br12 by Materials Project

(Ta)2(Se)17(Br)12 crystallizes in the triclinic P-1 space group. The structure is zero-dimensional and consists of twenty-four hydrobromic acid molecules, four tantalum molecules, and two Se clusters. In each Se cluster, there are seventeen inequivalent Se2- sites. In the first Se2- site, Se2- is bonded in a water-like geometry to two Se2- atoms. There are one shorter (2.34 Å) and one longer (2.38 Å) Se–Se bond lengths. In the second Se2- site, Se2- is bonded in a water-like geometry to two Se2- atoms. The Se–Se bond length is 2.33 Å. In the third Se2- site, Se2- is bonded in a water-like geometry to two Se2- atoms. There are one shorter (2.32 Å) and one longer (2.47 Å) Se–Se bond lengths. In the fourth Se2- site, Se2- is bonded in a water-like geometry to two Se2- atoms. The Se–Se bond length is 2.45 Å. In the fifth Se2- site, Se2- is bonded in a water-like geometry to two Se2- atoms. The Se–Se bond length is 2.39 Å. In the sixth Se2- site, Se2- is bonded in a water-like geometry to two Se2- atoms. The Se–Se bond length is 2.34 Å. In the seventh Se2- site, Se2- is bonded in a water-like geometry to two Se2- atoms. The Se–Se bond length is 2.41 Å. In the eighth Se2- site, Se2- is bonded in a water-like geometry to two Se2- atoms. The Se–Se bond length is 2.28 Å. In the ninth Se2- site, Se2- is bonded in a water-like geometry to two Se2- atoms. The Se–Se bond length is 2.57 Å. In the tenth Se2- site, Se2- is bonded in a trigonal non-coplanar geometry to three Se2- atoms. The Se–Se bond length is 2.39 Å. In the eleventh Se2- site, Se2- is bonded in a water-like geometry to two Se2- atoms. The Se–Se bond length is 2.36 Å. In the twelfth Se2- site, Se2- is bonded in a water-like geometry to two Se2- atoms. The Se–Se bond length is 2.35 Å. In the thirteenth Se2- site, Se2- is bonded in a water-like geometry to two Se2- atoms. The Se–Se bond length is 2.39 Å. In the fourteenth Se2- site, Se2- is bonded in a trigonal non-coplanar geometry to three Se2- atoms. The Se–Se bond length is 2.56 Å. In the fifteenth Se2- site, Se2- is bonded in a distorted water-like geometry to two Se2- atoms. The Se–Se bond length is 2.28 Å. In the sixteenth Se2- site, Se2- is bonded in a water-like geometry to two Se2- atoms. The Se–Se bond length is 2.40 Å. In the seventeenth Se2- site, Se2- is bonded in a distorted water-like geometry to two Se2- atoms.

36 MATERIALS SCIENCE↗

Materials Data on TaP2S2Cl5 by Materials Project

TaCl5(PS1)2 crystallizes in the monoclinic P2_1/c space group. The structure is zero-dimensional and consists of four 2,4,7,8-tetrathia-1,3,5,6-tetraphosphatricyclo[3.2.1.0^{3,6}]octane molecules and eight tantalum chloride (tacl5) molecules.

36 MATERIALS SCIENCE↗

Materials Data on TaP2Se2Cl5 by Materials Project

TaCl5(PSe)2 crystallizes in the monoclinic P2_1/c space group. The structure is zero-dimensional and consists of eight tantalum chloride (tacl5) molecules and four PSe clusters. In each PSe cluster, there are four inequivalent P2+ sites. In the first P2+ site, P2+ is bonded in a water-like geometry to two Se2- atoms. There are one shorter (2.27 Å) and one longer (2.29 Å) P–Se bond lengths. In the second P2+ site, P2+ is bonded in a trigonal non-coplanar geometry to three Se2- atoms. There are two shorter (2.29 Å) and one longer (2.31 Å) P–Se bond lengths. In the third P2+ site, P2+ is bonded in a water-like geometry to two Se2- atoms. There are one shorter (2.27 Å) and one longer (2.29 Å) P–Se bond lengths. In the fourth P2+ site, P2+ is bonded in a single-bond geometry to one Se2- atom. The P–Se bond length is 2.22 Å. There are four inequivalent Se2- sites. In the first Se2- site, Se2- is bonded in a distorted water-like geometry to two P2+ atoms. In the second Se2- site, Se2- is bonded in a water-like geometry to two P2+ atoms. In the third Se2- site, Se2- is bonded in a distorted L-shaped geometry to two P2+ atoms. In the fourth Se2- site, Se2- is bonded in a distorted water-like geometry to two P2+ atoms.

36 MATERIALS SCIENCE↗

Materials Data on TaP4(SCl)5 by Materials Project

TaCl5P4S5 crystallizes in the monoclinic P2_1/c space group. The structure is zero-dimensional and consists of four tantalum chloride (tacl5) molecules and four tetraphosphorus pentasulfide molecules.

36 MATERIALS SCIENCE↗

Materials Data on Ta2Mo2O5 by Materials Project

TaTaMo2O5 crystallizes in the tetragonal P4/mmm space group. The structure is two-dimensional and consists of one tantalum molecule and one TaMo2O5 sheet oriented in the (0, 0, 1) direction. In the TaMo2O5 sheet, Ta3+ is bonded to twelve O2- atoms to form a mixture of corner and face-sharing TaO12 cuboctahedra. There are eight shorter (2.31 Å) and four longer (2.44 Å) Ta–O bond lengths. Mo2+ is bonded in a 4-coordinate geometry to four equivalent O2- atoms. All Mo–O bond lengths are 2.06 Å. There are two inequivalent O2- sites. In the first O2- site, O2- is bonded to two equivalent Ta3+ and two equivalent Mo2+ atoms to form a mixture of distorted edge and corner-sharing OTa2Mo2 tetrahedra. In the second O2- site, O2- is bonded in a distorted square co-planar geometry to four equivalent Ta3+ atoms.

36 MATERIALS SCIENCE↗

CHARACTERIZATION OF RADIATION DAMAGES TO POSITRON SOURCE MATERIALS

The secondary beam production target at future positron sources at the Continuous Electron Beam Accelerator Facility (CEBAF), the International Linear Collider (ILC) or the Future Circular Collider (FCC), features unprecedented mechanical and thermal stresses which may compromise sustainable and reliable operation. Candidate materials are required to possess high melting temperature together with excellent thermal conductivity, elasticity and radiation hardness properties. In order to substantiate the material choice for the CEBAF and ILC positron sources, the response of candidate materials such as titanium alloys, tungsten, and tantalum to electron beam irradiation was experimentally investigated. CEBAF and ILC expected operating conditions were mimicked using the 3.5 MeV electron beam of the MAMI facility injector. The material degradations were precisely analyzed via high energy X-ray diffraction at the HEMS beamline operated by the Helmholtz-Zentrum Hereon at the PETRA III synchrotron facility. This work reports the results of these measurements and their interpretation.

Lengler, T.↗

Electron beam irradiated foil expansion simulated by a coupled HYDRA/MCNP6 application

Simulating the hydrodynamic evolution of a temporally pulsed electron beam with multiple metal foils requires coupling the nearly monoenergetic, relativistic electron beam to the foil target. This deposition may be effectively calculated by Monte Carlo transport. Once this energy is deposited on a computational mesh representing the foil target, highly developed radiation-hydrodynamic codes, such as HYDRA, can describe the subsequent evolution. Currently, HYDRA does not have an internal Monte Carlo electron transport capability. To partially rectify this deficiency, a PYTHON-based scheme to link MCNP6 to HYDRA has been developed for quadrilateral meshes. Results from a seven-foil tantalum target configuration are presented to demonstrate this capability.

42 ENGINEERING↗

Characterization of Self-Magnetic Pinch (SMP) Radiographic Diode Performance on RITS-6 at Sandia National Laboratories

The goals of an electron beam-driven radiographic source are the focusing of high current at high voltage to a minimal spot size with excellent shot-to-shot reproducibility. The Self-Magnetic Pinch (SMP) diode makes use of such an intense electron beam impinging on a high-atomic weight (tantalum) converter, a counter-streaming ion beam to help minimize the spot size, and operation in a magnetic field-free diode region which further encourages small spot size. Through a series of diode development experiments, output voltages up to 12.5 MV and output currents up to 225 kA have been characterized, with resulting spot sizes below ~ few mm. Scaling studies with parameter variation, such as diode aspect ratio and anode-cathode (A-K) gap variation, give systematic validation to what has heretofore been noted anecdotally by other research groups. While the lack of an imbedded magnetic field helps minimize the SMP spot size, a secondary result may be the generation of beam instabilities which can terminate the radiation pulse. There is anecdotal evidence that in-situ DC heating of the diode region can help stabilize the beam pinch. Clear experimental evidence exists that DC heating/RF cleaning results in better control over the counter-streaming ion population. Expanded use of spatial dose-rate detection is shown to yield new insights into electron beam dynamics in the SMP diode. An attendant study of the SMP diode as a load for an Inductive Voltage Adder (IVA) driver leads to insights into the behavior of the IVA-SMP diode configuration, viewed as a total system, and yields constraints on the overall impedance behavior of the SMP diode load.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Assembly Operations Welding Filter(s) in Drum Calculation

This calculation documents the estimation of temperature and pressure rise inside a 55-gal TRU waste drum with a HEPA filter containing Titanium and Tantalum fume dust based on operational history.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A New MCNP6 Electron-Photon Transport Validation Test: The Lockwood Energy Deposition Experiment (V.1.0)

This memo announces the availability of a new validation test for quantifying the accuracy of the MCNP6 electron-photon transport algorithm for use in energy-deposition calculations. Specifically, energy-deposition results are compared with the Lockwood energy-deposition experiment. The comparison includes energy-deposition profiles in a variety of different single-element materials including beryllium, aluminum, carbon, copper, iron, molybdenum, tantalum, and uranium for pencil beam electron sources with energies including 0.05-, 0.1-, 0.3-, 0.5, and 1-MeV and angles of incidence including normal, 30°, and 60° off-normal. The purpose of this memo is to discuss the contents of the Lockwood validation directory and to outline the procedure for generating the input files, running the tests, processing the results, and comparing results to the experimental and numerical benchmark. Each step is mostly automated by a makefile that executes the necessary perl script.

74 ATOMIC AND MOLECULAR PHYSICS↗

Transmitted wave measurements in cold sprayed materials under dynamic compression

Spray-formed materials have complex microstructures which pose challenges for microscale and mesoscale modeling. To constrain these models, experimental measurements of wave profiles when subjecting the material to dynamic compression are necessary. The use of a gas gun to launch a shock into a material is a traditional method to understand wave propagation and provide information of time-dependent stress variations due to complex microstructures. This data contains information on wave reverberations within a material and provides a boundary condition for simulation. Here we present measurements of the wavespeed and wave profile at the rear surface of tantalum, niobium, and a tantalum/niobium blend subjected to plate impact. Measurements of the Hugoniot elastic limit are compared to previous work and wavespeeds are compared to longitudinal sound velocity measurements to examine wave damping due to the porous microstructure.

36 MATERIALS SCIENCE↗

Upgrade of Gamma Spectrometry Systems for ORNL TRISO Fuel PIE

Gamma spectrometry is a key element in much of the post-irradiation examination (PIE) work performed under the Advanced Gas Reactor Fuel Development and Qualification (AGR) Program (Demkowicz et al. 2015; Stempien et al. 2021). Gamma spectrometers are integrated into three major capabilities used at the Oak Ridge National Laboratory (ORNL) Irradiated Fuels Examination Laboratory (IFEL) for PIE of tristructural-isotropic (TRISO) coated particles and fuel compacts: the Core Conduction Cooldown Test Facility (CCCTF), the Vertical Counting System (VCS), and the Irradiated Microsphere Gamma Analyzer (IMGA). The CCCTF includes liquid-nitrogen-cooled traps to extract 85 Kr out of the He sweep gas that passes through the furnace in which the fuel compacts are heated during safety testing. Analysis of the 85 Kr activity in the traps is the primary indicator for TRISO failure during safety testing. The VCS is a system used to accurately measure gamma emission from components placed in a lead-shielded chamber. It is used to count the CCCTF deposition cups after removal from furnace. Each cup resides in the CCCTF furnace for typically 12–24 h and is periodically replaced with a fresh cup throughout the safety test. Metallic fission products collect on the water-cooled cups and several gamma-emitting isotopes ( 110 mAg, 134 Cs, 137 Cs, 154 Eu, and 155 Eu) are often measured and provide indication of the retention performance of the TRISO coatings. The VCS is also used to measure the presence of these isotopes on the CCCTF tantalum liner and sweep gas inlet tube for the determination of cup collection efficiency, as well as support other gamma spectrometry needs related to calibration of the 85 Kr fission gas traps and various other special PIE tasks. The IMGA uses gamma spectrometry to measure the inventory of gamma-emitting isotopes in individual TRISO particles. An automated particle handling system within the IMGA hot cell removes each particle from a source vial and positions it in front of a gamma detector, and output from the gamma spectrometer is used by the IMGA software to determine a destination vial such that particles are sorted according to their inventory and retention characteristics. At the conclusion of the AGR-1 and AGR-2 PIE campaigns, the gamma spectrometer systems used at ORNL to support that PIE had reached the end of its life cycle due to gradual obsolescence of the hardware and software. Upgrade of the Canberra Genie 2000 software used by these systems to a Windows 10 version was not a viable option, because the newest Windows 10 version offered by Mirion (the new owner of the Canberra technology) did not include the dynamic-link libraries (DLLs) needed for integration with the custom PIE software used with the CCCTF and IMGA, and Mirion had no current plans for development and release of Windows 10 versions of these DLLs with the Model S560 Genie 2000 Programming Library. Ultimately a switch was made to ORTEC gamma spectrometry systems, which appeared to be a more sustainable solution due to more proactive vendor support. The ORTEC conversion involved replacing the aging detector preamplifier and multichannel analyzer (MCA) hardware, upgrading the obsolete Windows 7 computers to Windows 10 compatible models, adopting ORTEC GammaVision software, and extensive modification of the ORNL-developed Visual Basic .NET (VB.NET) programs that provide the CCCTF and IMGA user interfaces.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nuclear data covariances are critical input to determine upper sub-critical limits and to design experiments to increase it [Slides]

This presentation discusses how Upper Subcritical Limits (USL) are key parameters to determine operational limits in nuclear criticality safety evaluations. It also discusses an example of plutonium casting operation using tantalum at LANL PF-4. The Whisper tool at Los Alamos relies on many inputs, including covariance data, leading the presentation to ask if an existing benchmark data be used in Whisper to adjust nuclear data and covariances to justify a higher USL. If not, Whisper can be used to help design an optimal new benchmark experiment. The presentation also seeks to determine what the possible impacts are on USL and operational limits for plutonium casting. In conclusion, nuclear data covariances are used for by Whisper for: GSSL adjustment of nuclear data and covariances, identification of most similar existing benchmark experiments to application, simulation of Upper Subcritical Limit of application, and input to optimization techniques for designing most appropriate new benchmark experiment(s) to meet requirements. This requires a complete set of nuclear data covariances, benchmarks and k-effective sensitivity profiles (for both benchmarks and applications). The presentation concludes by asking if end users should trust results that depend on current covariance data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗