Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “storage performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Performance of MoS2 Coated Gears Exposed to Humid Air During Storage - (Study Number Two)

This work is a follow-on to a prior study on the effect of exposure to humid air on the durability of a molybdenum disulfide (MoS2) dry film lubricant on spur gears operated in vacuum, motivated by the James Webb Space Telescope (JWST) mission. In this study, MoS2 dry-lubricating films (DFLs) matching JWST specification were applied to test gears. The gear specimens were subjected to a brief run-in period in vacuum prior to their exposure to humid air, mimicking the sequence of mechanism checkout testing, exposure to air during integration, and then storage prior to launch. Test gear exposure times to humid air ranged from 1 hour to 326 days. After exposure, gear durability tests were conducted as an indication of film lifetime. MoS2 DFLs that were exposed to humid air (57% RH) exhibited reduced film durability relative to DFLs that were not exposed. On average, the exposed specimens demonstrated 75% shorter film life. The severity of the reduction in film durability did not correlate with the duration of exposure, i.e., long exposures to humid air were not more impactful to film durability than were short exposures.

MoS2↗

Leakage detection using smart field technology

Various examples are provided for gas leakage detection from geologic storage sites. In one example, a system for detection of gas leakage from a geologic storage site includes permanent down-hole gauges (PDGs) disposed at different depths within a well and an evaluation system that can determine a three-dimensional (3D) location of the gas leakage from the geologic storage site and a leakage indicator. The 3D location and leakage indicator can be determined using pressure data provided by the PDGs. The geologic storage site can store, e.g., CO2, natural gas or other type of gas. In another example, a method for detecting gas leakage from a geologic storage site includes receiving pressure data provided by PDGs disposed within one or more wells associated with the geologic storage site, determining key performance indicators using the pressure data and determining a 3D location and a leakage indicator using the key performance indicators.

47 OTHER INSTRUMENTATION↗

A Ceph S3 Object Data Store for HEP

We present a novel data format design that obviates the need for data tiers by storing individual event data products in column objects. The objects are stored and retrieved through Ceph S3 technology, with a layout designed to minimize metadata volume and maximize data processing parallelism. Performance benchmarks of data storage and retrieval are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Mechanical Response of Cr-Coated Zircaloy-4 Cladding to Pellet-Cladding Interactions

Chromium-coated zircaloy is a promising accident tolerant fuel (ATF) cladding design which can help mitigate high temperature oxidation. The mechanical response of the cladding during and after loading may be altered by the Cr coating throughout anticipated operational and accident occurrences such as a pellet-cladding interaction (PCI). In this work, the mechanical behavior of Cr-coated and uncoated cold worked stress-relieved (CWSR) Zircaloy-4 (Zry-4) cladding to PCI loading conditions are studied. Stress relaxation tests are performed on CWSR Zry-4 cladding using full-tube axial tension and internal pressurization to investigate mechanical anisotropy and rate-limiting deformation mechanisms of the uncoated Zry-4. These results are compared to internal pressure testing results of similar cladding with physical vapor deposition (PVD) Cr-coating to reveal how the Cr-coating affects the cladding mechanical response. Findings are discussed in the context of ATF cladding performance during operation and storage.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Performance Assessment of a Heat Pump Integrated with Thermal Energy Storage in Cooling & Heating Modes

Thermal Energy Storage (TES) systems have demonstrated significant potential to manage the fluctuating nature of energy demand and shifting peak loads. This technology has made significant recent advances, including new research on the integration of TES with residential and commercial Heating, Ventilation, and Air-Conditioning (HVAC) systems. In this paper, we present the use of a novel laboratory assessment framework for a prototype heat pump system integrated with latent heat phase change material-based TES. The assessment framework consists of 22 total test points (11 heating, 11 cooling) using psychrometric conditions from AHRI Standard 210/240 and includes transient conditions to evaluate TES charging and discharging modes. In addition, both continuous mode and cyclic mode were evaluated for charging and discharging to explore the benefits to TES heat transfer from repeated transient operation. The ambient conditions evaluated include heating mode charging at cold-climate heat pump conditions when winter-peaking utilities may most require demand reduction (H4Full conditions, 5°F/-15°C) and cooling mode charging at high ambient temperature that may occur during times of day when excess solar power generation results in low-cost electricity (105°F/40.6°C). The work demonstrates the demand reduction capabilities of integrating TES with HVAC, including up to 44% in cooling mode and 60% in heating mode compared to conventional HVAC equipment without TES.

25 ENERGY STORAGE↗

SNF Interim Storage Canister Corrosion and Surface Environment Investigations (FY21 Status Report)

This progress report describes work performed during FY21 at Sandia National Laboratories (SNL) to assess the localized corrosion performance of canister materials used in the interim storage of spent nuclear fuel (SNF). Of particular concern is stress corrosion cracking (SCC), by which a through-wall crack could potentially form in a canister outer wall over time intervals that are shorter than possible dry storage times. In FY21, modeling and experimental work was performed that further defined our understanding of the potential chemical and physical environment present on canister surfaces at both marine and inland sites. Research also evaluated the relationship between the environment and the rate, extent, and morphology of corrosion, as well as the corrosion processes that occur. Finally, crack growth rate testing under relevant environmental conditions was initiated.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Study to establish cost predictions for the production of Redox chemicals

The chromium and iron chloride chemicals are significant first costs for NASA Redox energy storage systems. This study was performed to determine the lowest cost at which chromium and iron chlorides could be obtained for a complex of redox energy storage systems. In addition, since the solutions gradually become intermixed during the course of operation of Redox units, it was an objective to evaluate schemes for regeneration of the operating solutions. Three processes were evaluated for the production of chromium and iron chlorides. As a basis for the preliminary plant design and economic evaluation, it was assumed that the plant would produce about 25,000 tons of contained chromium as CrCl3 and an equivalent molar quantity of FeCl2. Preliminary plant designs, including materials and energy balances and sizing of major equipment, were prepared, and capital and operating costs were estimated.

Ammann, P. R.↗

Optimize heat prosumers' economic performance under current heating price models by using water tank thermal energy storage

Due to heat prosumers' dual roles of heat producer and heat consumer, the future district heating (DH) systems will become more flexible and competitive. However, the current heating price models have not yet supported the reverse heat supply from prosumers to the central DH system, which means the prosumers would gain no economic benefit from supplying heat to the central DH system. These unidirectional heating price models will reduce interest in prosumers, and thus hinder the promotion of prosumers in DH systems. This study aimed to optimize prosumers' economic performance under the current heating price models by introducing water tank thermal energy storage (WTTES). A dynamic optimization problem was formulated to explore prosumers' economic potentials. The size parameter of WTTESs was swept in prosumers to obtain the optimal storage size considering the trade-off between the payback period and the heating cost saving. The proposed method was tested on a campus DH system in Norway. The results showed that the prosumer's annual heating cost was saved up to 9%, and the investment of WTTES could be recovered in less than ten years. This study could provide guidelines on improving prosumers' economic performance and promote the development of prosumers during the transformation period of DH systems.

Li, H↗

Characterization of iron-doped lithium niobate for holographic storage applications

A comprehensive characterization of chemical and holographic properties of eight systematically chosen Fe:LiNbO3 crystals is performed in order to determine optimum performance of the crystals in holographic storage and display applications. The discussion covers determination of Fe(2+) and Fe(3+) ion concentrations in Fe:LiNbO3 system from optical absorption and EPR measurements; establishment of the relation between the photorefractive sensitivity of Fe(2+) and Fe(3+) concentrations; study of the spectral dependence, the effect of oxygen annealing, and of other impurities on the photorefractive sensitivity; analysis of the diffraction efficiency curves for different crystals and corresponding sensitivities with the dynamic theory of hologram formation; and determination of the bulk photovoltaic fields as a function of Fe(2+) concentrations. In addition to the absolute Fe(2+) concentration, the relative concentrations of Fe(2+) and Fe(3+) ions are also important in determining the photorefractive sensitivity. There exists an optimal set of crystal characteristics for which the photorefractive sensitivity is most favorable.

Shah, R. R.↗

Bio-Energy with Carbon Capture and Storage (BECCS): Achieving Net Zero and Beyond

This work evaluates the life cycle environmental performance of Bioenergy with Carbon Capture and Storage (BECCS) across different biomass types, processing technologies, and capture rates. Preliminary results suggest that carbon neutrality could be achieved if 35% biomass is co-fired with 90% carbon capture and sequestration.

Carlson, Derrick R.↗

Operations, maintenance, and cost considerations for PV+Storage in the United States

Battery storage systems are increasingly being installed at photovoltaic (PV) sites to address supply-demand balancing needs. Although there is some understanding of costs associated with PV operations and maintenance (O&M), costs associated with emerging technologies such as PV plus storage lack details about the specific systems and/or activities that contribute to the cost values. This study aims to address this gap by exploring the specific factors and drivers contributing to utility-scale PV plus storage systems (UPVS) O&M activities costs, including how technology selection, data collection, and related and ongoing challenges. Specifically, we used semi-structured interviews and questionnaires to collect information and insights from utility-scale owners and operators. Data was collected from 14 semi-structured interviews and questionnaires representing 51.1 MW with 64.1 MWh of installed battery storage capacity within the United States (U.S.). Differences in degradation rate, expected life cycle, and capital costs are observed across different storage technologies. Most O&M activities at UPVS related to correcting under-performance. Fires and venting issues are leading safety concerns, and owner operators have installed additional systems to mitigate these issues. There are ongoing O&M challenges due the lack of storage-specific performance metrics as well as poor vendor reliability and parts availability. Insights from this work will improve our understanding of O&M consideration at PV plus storage sites.

14 SOLAR ENERGY↗

Data Management in the Continuum: Cross-facility Object-based Data Transfers

Scientific workflows are evolving from relying on a monolithic storage subsystem at a single High-Performance Computing (HPC) facility to using geographically distributed file systems, repositories, and cloud storage. As a result, storing, accessing, transferring, and managing scientific data have become highly complex and prone to performance inefficiencies. This paper delves into these challenges by exploring an optimized end-to-end interface designed to seamlessly connect various local and remote storage systems, enabling efficient data movement of objects across HPC–Cloud and HPC–HPC environments. We showcase this capability through an object-focused data management runtime system, discuss the effects of relaxed consistency semantics in distributed object scenarios, and illustrate its application in an earthquake simulation workflow. Besides reducing the amount of data by selectively transferring regions of interest, our facility-local results achieved a speedup of 45 × over an optimized HDF5 usage and 15 × over the HDF5 with caching by using the new interface in PDC-XF.

Bez, Jean Luca↗

Lithium-Ion rechargeable batteries on Mars Rover

NASA's Mars Rovers, Spirit and Opportunity, have been roving on the surface of Mars, capturing impressive images of its terrain and analyzing the drillings from Martian rocks, to answer the ever -puzzling questions of life beyond Earth and origin of our planets. These rovers are being enabled by an advanced rechargeable battery system, lithium-ion, for the first time on a space mission of this scale, for keeping the rover electronics warm, and for supporting nighttime experimentation and communications. These rover Li-ion batteries are characterized by their unique low temperature capability, in addition to the usual advantages associated with Li-ion chemistry in terms of mass, volume and energy efficiency. To enable a rapid insertion of this advanced Li-ion chemistry into flight missions, we have performed several performance assessment studies on several prototype cells over the last few years. These tests mainly focused primarily on the long-term performance characteristics, such as cycling and storage, as described in our companion paper. In addition, various tests have been performed on MER cells and engineering and proto flight batteries; under conditions relevant to these missions. For example, we have examined the performance of the cells in: a) an inverted orientation, as during integration and launch, and b) conditions of low rate discharge, between 3.0-2.5 V to support the mission clock. Likewise, we have determined the impedance of the proto-flight Rover battery assembly unit in detail, with a view to asses whether a current-limiting resistor would be unduly stressed, in the event of a shorting induced by a failed pyro. In this paper we will describe these studies in detail, as well as the performance of Li-ion batteries in Spirit and Opportunity rovers, during cruise and on Mars.

2003 Mars Exploration Rover (MER)↗

Improved thermal storage material for portable life support systems

The availability of thermal storage materials that have heat absorption capabilities substantially greater than water-ice in the same temperature range would permit significant improvements in performance of projected portable thermal storage cooling systems. A method for providing increased heat absorption by the combined use of the heat of solution of certain salts and the heat of fusion of water-ice was investigated. This work has indicated that a 30 percent solution of potassium bifluoride (KHF2) in water can absorb approximately 52 percent more heat than an equal weight of water-ice, and approximately 79 percent more heat than an equal volume of water-ice. The thermal storage material can be regenerated easily by freezing, however, a lower temperature must be used, 261 K as compared to 273 K for water-ice. This work was conducted by the United Aircraft Research Laboratories as part of a program at Hamilton Standard Division of United Aircraft Corporation under contract to NASA Ames Research Center.

Kellner, J. D.↗

The mass storage testing laboratory at GSFC

Industry-wide benchmarks exist for measuring the performance of processors (SPECmarks), and of database systems (Transaction Processing Council). Despite storage having become the dominant item in computing and IT (Information Technology) budgets, no such common benchmark is available in the mass storage field. Vendors and consultants provide services and tools for capacity planning and sizing, but these do not account for the complete set of metrics needed in today's archives. The availability of automated tape libraries, high-capacity RAID systems, and high- bandwidth interconnectivity between processor and peripherals has led to demands for services which traditional file systems cannot provide. File Storage and Management Systems (FSMS), which began to be marketed in the late 80's, have helped to some extent with large tape libraries, but their use has introduced additional parameters affecting performance. The aim of the Mass Storage Test Laboratory (MSTL) at Goddard Space Flight Center is to develop a test suite that includes not only a comprehensive check list to document a mass storage environment but also benchmark code. Benchmark code is being tested which will provide measurements for both baseline systems, i.e. applications interacting with peripherals through the operating system services, and for combinations involving an FSMS. The benchmarks are written in C, and are easily portable. They are initially being aimed at the UNIX Open Systems world. Measurements are being made using a Sun Ultra 170 Sparc with 256MB memory running Solaris 2.5.1 with the following configuration: 4mm tape stacker on SCSI 2 Fast/Wide; 4GB disk device on SCSI 2 Fast/Wide; and Sony Petaserve on Fast/Wide differential SCSI 2.

Venkataraman, Ravi↗