Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “scintillation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Adiabatic light guide with S-shaped strips

A light guide is an essential part of many scintillator counters and light collection systems. Our main interest is a light guide for a thin, wide scintillator that has high light transmission while converting the area of the light source to the shape of a photo-detector. Here, we propose a variation of the light guide that avoids a 90° twist of the strips, reduces the length of the light pipe, and reduces the complexity of production. Detailed Monte Carlo simulation studies have been performed for a three-strip S-shaped light-guide system.

47 OTHER INSTRUMENTATION↗

Optically multiplexed neutron time-of-flight technique for inertial confinement fusion

Neutron time-of-flight (nTOF) detectors are crucial in diagnosing the performance of inertial confinement fusion (ICF) experiments, which implode targets of deuterium–tritium fuel to achieve thermonuclear conditions. These detectors utilize the fusion neutron energy spectrum to extract key measurements, including the hotspot ion temperature and fuel areal density. Previous work [Danly et al., Rev. Sci. Instrum. 94, 043502 (2023)] has demonstrated adding 1D spatial resolution to an nTOF-like detector using a neutron aperture and streak camera to measure the ion temperature profile of an ICF implosion. By contrast, the study presented herein explores modifying the 1D detector to use a fast photomultiplier tube (PMT) to validate the design of a 2D spatially resolved instrument based on reconstruction from 1D profiles. The modification would collect time-of-flight traces from separate scintillators in an imaging array with one PMT using optical fibers of varying lengths to time-multiplex the signals. This technique has been demonstrated in ride-along experiments on the OMEGA laser with 20 fiber-coupled scintillator channels connected to a Photek PMT210. Results provide constraints on the fiber lengths and PMT gating requirements to promote pulse fidelity throughout all channels. Calibration of the detector to fixed nTOFs can provide a preliminary estimate of the instrument response function (IRF), although measurement of the IRF is currently under way. These results suggest that nTOF signals can potentially be time-multiplexed with fibers so long as the design is strategic to mitigate signal-to-noise reduction, modal dispersion, and charge build-up in the PMT, which has implications beyond ion temperature imaging.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Solid, structured composite neutron detectors with high dynamic range capability

Neutron detectors are essential across disciplines such as fundamental science, nuclear security, safeguards, and civilian applications. While 3 He-filled gas proportional counters have long been revered for their efficacy in detecting thermal neutrons and praised for their efficiency, neutron/gamma discrimination, and stability, the scarcity of 3He has spurred a search for alternatives. Here, we explore a solid structured scintillating particle composite (SPC) consisting of 6 Li-containing scintillating glass particles within an acrylic matrix as a neutron detector for high dynamic range applications. We show for the first time that an SPC neutron detector can boast an intrinsic detection efficiency of 0.261% for pure 252 Cf fission neutrons and an overall neutron detection efficiency of (0.546 ± 0.003)% at the Neutron Free-in-Air facility while being able to function in an intense gamma-ray environment. We also show that the SPC neutron detector supports fast neutron capture times and enables a dual-readout scheme that extends the detector dynamic range to high incident neutron fluxes. A scalable fabrication process allows for tailoring the SPC detector properties to the requirements of specific applications. Good agreement is found between the experimental results taken with a National Institute of Standards and Technology traceable 252 Cf source and the coupled MCNP6 and optical-ray-tracing simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermal Characterization of Tl 2 LiYCl 6 :Ce (TLYC)

Tl 2 LiYCl 6 :Ce (TLYC) is a new dual-detection elpasolite scintillator that can detect and distinguish between gamma rays and neutrons using pulse shape discrimination (PSD). It has a higher density and Z -number than the more mature and well-known elpasolite Cs 2 LiYCl 6 :Ce (CLYC), causing it to have a significantly better gamma-ray stopping power. These properties make TLYC an attractive alternative to CLYC for resource-constrained applications where size and weight are important, such as space or national security applications. Such applications may be subjected to a wide range of temperatures, and therefore, TLYC's performance was characterized for the first time over a temperature range of -20 °C to +50 °C in 10 °C increments. TLYC's thermal response effects on light-output linearity with energy, gamma-ray photopeak energy resolution, detected neutron energy, pulse shapes, and figure of merit (FOM) is analyzed and reported. The light output of TLYC was found to be linear with energy over the tested temperature range and was observed to decrease with increasing temperature. The decay time of the scintillation light output was observed to decrease with decreasing temperature at short times, leading to a decreasing PSD FOM. The gamma-ray photopeak energy resolution was also observed to degrade with decreasing temperature, due to an asymmetric broadening of the photopeak at low temperatures.

36 MATERIALS SCIENCE↗

A Large Area Picosecond Photodetector for Neutron Transmission Measurements at DICER at LANSCE

The Device for Indirect Capture Experiments on Radionuclides (DICER) is a new instrument that is being developed at the Los Alamos Neutron Science Center (LANSCE) to study neutron capture reactions on short-lived radionuclides. To achieve that, DICER is using an indirect technique based on measuring the neutron transmission through very small samples (0.12–1.2 mm in diameter, $\mu \text{g}$ -mg in mass). The main detection system of DICER consists of two dual photomultiplier (PMT)-based detectors which are sensitive to the scintillation light produced when neutrons interact with 6 Li glass disks. DICER is developing a new collimation system that includes a 0.1-mm collimator. In such small sizes, the need for neutron beam imaging is crucial and necessary to confirm the appropriate alignment between the irradiated sample and the neutron detectors. The large area picosecond photodetector (LAPPD) is a multichannel plate (MCP)-based photodetector, with picosecond-level timing, single-photon detection capabilities, and spatial resolution of the order of 1 mm. Coupling the LAPPD with a 6 Li glass scintillator results in a neutron imaging detector. The first irradiation of the LAPPD at DICER indicated that apart from imaging the beam, the LAPPD can be used as the main neutron detection system. Furthermore, these results were proof of principle measurements demonstrating the capabilities of the beamline, and the challenge with small samples will be addressed in the future. The first efforts and developments, including irradiations of the LAPPD and the first beam images, will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of angle-resolved reflectivity of PTFE in liquid xenon with IBEX

Abstract Liquid xenon particle detectors rely on excellent light collection efficiency for their performance. This depends on the high reflectivity of polytetrafluoroethylene (PTFE) at the xenon scintillation wavelength of 178 nm, but the angular dependence of this reflectivity is not well-understood. IBEX is designed to directly measure the angular distribution of xenon scintillation light reflected off PTFE in liquid xenon. These measurements are fully described by a microphysical reflectivity model with few free parameters. Dependence on PTFE type, surface finish, xenon pressure, and wavelength of incident light is explored. Total internal reflection is observed, which results in the dominance of specular over diffuse reflection and a reflectivity near 100% for high angles of incidence.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Comparison of NMC estimates with trans-stilbene, EJ-309, and He-3 detection systems

Neutron multiplicity counting (NMC) is a technique for the assay of fissile material. In this work, three detection systems are utilized for active interrogation assay of shells of the Rocky Flats shells (highly enriched uranium, 93% 235U) stacked from 13.25-54.92 kg assemblies. The singles ($R_1$) and doubles ($R_2$) rates are calculated with each system to estimate two sample parameters: $M_L$- the leakage multiplication and F - the sample fission rate. The estimated mass, m, is found by dividing F by a constant activity per unit mass. Since we are interrogating HEU, the α ratio of (α; n) to fission neutrons is taken to be zero. The system of equations to calculate these quantities was originally derived. The Neutron Multiplicity 3 He Array Detector (NOMAD) consists of 15 3 He tubes inside polyethylene and is the traditional, capture-based detection system for NMC. The polyethylene moderates incoming neutrons for thermal capture in individual tubes. The low gamma background, discrete capture signals, and high efficiency of the NOMAD are beneficial for NMC. However, the time to slow down neutrons to thermal energies leads to a system die away time on the scale of microseconds. Comparatively, the Rossi-alpha Measurements – Rapid Organic (n, γ) Discrimination Detector (RAMRODD) and the Organic Scintillator Array (OSCAR) are scatter-based detection systems. RAMRODD consists of 8, 5.08 by 5.08 cm EJ-309 liquid scintillators in 4 pairs, evenly-spaced with 90 degrees separation about the center of each assembly. OSCAR consists of a single array of 12, 5.08 by 5.08 cm trans-stilbene crystals aligned with the center of the assembly. Scatter-based systems detect fast neutrons without any moderation, leading to system die away times on the scale of tens of nanoseconds. This allows much shorter timing gate widths compared to thermal systems, thus increasing counting statistics of true correlated fission events. However, scatter-based systems are susceptible to neutron cross-talk when an incident neutron scatters off one detector and interacts in an adjacent detector, causing two seemingly correlated detection signals. The equations developed adjust for cross-talk to conduct NMC with scatter-based systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron Multiplicity Counting Diagnosis of Uranium Assemblies Interrogated by Cf-252 [Poster]

Researchers concluded: First neutron multiplicity counting of tens of kilograms of 235 U with organic scintillators; leakage multiplication estimates to be improved by incorporating detector cross-talk; provides data comparison for “Multiplicity Theory Beyond the Point Model;" promotes continued use of organic scintillators for NCERC and elsewhere.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron detector development for high-rate neutron reflectometry at the Second Target Station of Oak Ridge National Laboratory

The Second Target Station (STS) at the Oak Ridge National Laboratory Spallation Neutron Source (SNS) is expected to produce a neutron source that is the brightest in the world, having a significantly higher peak brightness compared to the First Target Station (FTS), where the reflectometry instruments already fall short of being able to handle the highest available flux by a factor of ~100. The neutron reflectometers at the SNS FTS are not suitable for the reflectometers planned for the SNS STS because of its unprecedentedly high peak brightness and the already limited capabilities of these instruments at high count rates. Furthermore, the high rate instruments that are now under development are expected to underperform with regard to gamma sensitivity, meaning that signal-to-noise will be reduced and they will be unable to measure weaker reflectance phenomena in the presence of the significant prompt gamma flash at SNS. To address these challenges, we conducted research to advances associated instruments, techniques, and capabilities for the SNS STS reflectometers. More specifically, we investigated the development of a scalable, 2-D positive-sensitive, pixelated, scintillator-based neutron detector module based on a newly developed scintillator. The work has potential for impact on future neutron reflectometry instruments and neutron science performed at the SNS STS. In particular, the improved background rejection capability of the developed detector could extend the available experimental dynamic Q range, allowing it to measure weak reflectance phenomena.

reflectometry, radiation instrumentation, neutron ↗

Development of a Convolutional Neural Network Classifier for Data Starved Spectra - 20199

The Institute for Clean Energy Technology (ICET) at Mississippi State University is exploring the utility of machine learning in augmenting its mobile radiation surveying platforms, which are currently being developed as means to survey depleted uranium contaminated areas in support of remediation and decommissioning efforts. Mobile survey platforms provide a means to efficiently scan large areas of interest while reducing human exposure to radiation and other hazards. The survey platforms can also be used for scanning for any gamma emitting isotope in addition to depleted uranium. The spectral data that the platforms collect may be data starved with relatively low counts and poorly defined spectral features depending on the speed of the platforms and scintillation detector selection. Such data-starved spectra are difficult to use for isotope identification, requiring advanced knowledge of the possible radionuclides that could be present and environmental factors that could attenuate signals or introduce background noise. These factors in combination with the volume of survey data increases the time it takes to perform analysis of survey data when the source type is unknown. There are a number of algorithms in the field of machine learning that can be used to classify data that would be challenging and time-consuming for a human to identify. Supervised machine learning algorithms train models based on extensive amounts of human-labeled training data. Once sufficiently trained, these models can be used to quickly make high-fidelity predictions on new data. Convolutional neural networks are machine learning algorithms that excel in learning representations of 'shapes'. They do this by taking numerical input data and convolving them with spatial feature detectors referred to as filters. These filters are incrementally adjusted to reduce the prediction error on the data during the backpropagation step of training. Discussed in this paper is the development of a convolutional neural network classifier (CNNC) that can utilize spectral survey data for source discrimination and isotope identification. Bench-top laboratory experiments data using LaBr{sub 3}(Ce) scintillation detectors were used to train and evaluate the performance of the developed CNNC. The CNNC is capable of discriminating a variety of gamma emitting source types, differentiating different forms of uranium (depleted vs. natural), and estimating the amount of uranium for a known geometry. The discussed CNNC may be useful in scenarios where survey systems are deployed in situations where hazardous radioactive material maybe present, but the type is unknown. When used in remediation applications the CNNC can be used to screen-out false positives, helping reduce remediation costs. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Design and implementation of the cosmic ray tagger system for the ICARUS detector at FNAL

The ICARUS-T600 Liquid Argon Time Projection Chamber is operating at Fermilab at shallow depth and thus exposed to a high flux of cosmic rays that can fake neutrino interactions. A cosmic ray tagging (CRT) system (∼ 1100 m 2 ), surrounding the cryostat with two layers of fiber embedded plastic scintillators, was developed to mitigate the cosmic ray induced background. Using nanosecond-level timing information, the CRT can distinguish incoming cosmic rays from outgoing particles from neutrino interactions in the TPC. In this paper an overview of the CRT system, its installation and commissioning at Fermilab, and its performance are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An approach to characterizing spatial aspects of image system blur

Quantitative X-ray radiographic imaging systems that utilize a charged couple device (CCD) camera connected to a thick, monolithic scintillator can exhibit blur that varies spatially across the field of view, especially for thick scintillators used in pulse-power radiography of dynamically compressed objects. Here, a three-point approach to estimating and accounting for this effect is demonstrated by (a) using a local estimation technique to measure the effect of blurring a calibration object at key locations across the field of view, (b) combining each of the local estimates into a spatially varying blurring function via partitions of unity interpolation, and (c) resolving the effects of that blur on the image by solving an ill-posed inverse problem using a spatially varying regularization term. The technique is demonstrated on synthetic examples and actual radiographs collected at the Naval Research Laboratory’s (NRL)Mercury pulsed power facility.

97 MATHEMATICS AND COMPUTING↗

Low-diffusion Xe-He gas mixtures for rare-event detection: electroluminescence yield

High pressure xenon Time Projection Chambers (TPC) based on secondary scintillation (electroluminescence) signal amplification are being proposed for rare event detection such as directional dark matter, double electron capture and double beta decay detection. The discrimination of the rare event through the topological signature of primary ionisation trails is a major asset for this type of TPC when compared to single liquid or double-phase TPCs, limited mainly by the high electron diffusion in pure xenon. Helium admixtures with xenon can be an attractive solution to reduce the electron diffusion significantly, improving the discrimination efficiency of these optical TPCs. We have measured the electroluminescence (EL) yield of Xe-He mixtures, in the range of 0 to 30% He and demonstrated the small impact on the EL yield of the addition of helium to pure xenon. For a typical reduced electric field of 2.5 kV/cm/bar in the scintillation region, the EL yield is lowered by ~ 2%, 3%, 6% and 10% for 10%, 15%, 20% and 30% of helium concentration, respectively. This decrease is less than what has been obtained from the most recent simulation framework in the literature. The impact of the addition of helium on EL statistical fluctuations is negligible, within the experimental uncertainties. The present results are an important benchmark for the simulation tools to be applied to future optical TPCs based on Xe-He mixtures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for low-energy neutrinos from astrophysical sources with Borexino

We report on searches for neutrinos and antineutrinos from astrophysical sources performed with the Borexino detector at the Laboratori Nazionali del Gran Sasso in Italy. Electron antineutrinos ( $\bar{ν}_e$ ) are detected in an organic liquid scintillator through the inverse β -decay reaction. In the present work we set model-independent upper limits in the energy range 1.8-16.8 MeV on neutrino fluxes from unknown sources that improve our previous results, on average, by a factor 2.5. Using the same data set, we first obtain experimental constraints on the diffuse supernova $\bar{ν}_e$ fluxes in the previously unexplored region below 8 MeV. A search for $\bar{ν}_e$ in the solar neutrino flux is also presented: the presence of $\bar{ν}_e$ would be a manifestation of a non-zero anomalous magnetic moment of the neutrino, making possible its conversion to antineutrinos in the strong magnetic field of the Sun. We obtain a limit for a solar $\bar{ν}_e$ flux of 384 cm -2 s -1 (90% C.L.), assuming an undistorted solar 8 B neutrinos energy spectrum, that corresponds to a transition probability pνe→$\bar{ν}_e$< 7.2 ×10-5 (90% C.L.) for E $\bar{ν}_e$ > 1.8 MeV.At lower energies, by investigating the spectral shape of elastic scattering events, we obtain a new limit on solar 7 Be- ν e conversion into $\bar{ν}_e$ of pνe→$\bar{ν}_e$< 0.14 (90% C.L.) at 0.862 MeV. Last, we investigate solar flares as possible neutrino sources and obtain the strongest up-to-date limits on the fluence of neutrinos of all flavor neutrino below 3–7 MeV. Assuming the neutrino flux to be proportional to the flare’s intensity, we exclude an intense solar flare as the cause of the observed excess of events in run 117 of the Cl-Ar Homestake experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

COCOA: A compact Compton camera for astrophysical observation of MeV-scale gamma rays

COCOA (COmpact COmpton cAmera) is a next-generation gamma-ray telescope designed for astrophysical observations in the MeV energy range. The detector comprises a scatterer volume employing the LiquidO detection technology and an array of scintillating crystals acting as absorber. Surrounding plastic scintillator panels serve as a veto system for charged particles. The detector's compact, scalable design enables flexible deployment on microsatellites or high-altitude balloons. Gamma rays at MeV energies have not been well explored historically (the so-called "MeV gap") and COCOA has the potential to improve the sensitivity in this energy band.

79 ASTRONOMY AND ASTROPHYSICS↗

Thermal Processing Conditions for the Synthesis of Near Theoretical Density Li 5 La 3 Ta 2 O 12 Ceramics for Ceramic Dual-Mode Detectors

A family of Li-containing garnet compounds, extensively investigated for Li-ion solid electrolyte applications, show great potential to be developed into transparent ceramic dual-mode scintillators. In particular, Li 5 La 3 Ta 2 O 12 (LLTaO) shows promise as an efficient dual-mode scintillator due to its high Li content, high density, non-hygroscopicity, and high effective-Z. Often the synthesis of LLTaO ceramics involves solid state processing techniques starting with oxide and carbonate powders, calcining, sintering for the removal of residual porosity, and post-processing. This study focuses on two objectives: (1) establishing thermal processing boundary conditions for a flexible alkoxide-based sol-gel method for synthesizing fine-grained powders; and (2), consolidating powders via hot-pressing to form high-density ceramics. In this study, near single-phase ceramics were achieved by hot-pressing sol-gel powders with varying amounts of excess Li. Rietveld refinements were used to analyze X-ray diffraction data and provide a quantitative evaluation of the phases present in the hot pressed ceramics. Some of the diffraction data showed large low angle peak asymmetry, suggesting the presence of two cubic Li 5 La 3 Ta 2 O 12 garnet phases with different lattice parameters. Depending on the synthesis and processing conditions, the refinement revealed ~ 90 wt% concentration of a phase with a ≈ 12.8 Å and ~ 10 wt% concentration of a phase with a ≈ 12.9 Å, indicating a remaining excess of Li in the hot pressed ceramics in the large lattice parameter phase. These synthesis experiments allowed for the determination of a baseline for Li loss during hot-pressing. X-ray excited radioluminescence and photoluminescence excitation and emission spectra were obtained from the hot pressed ceramics. In conclusion, the measured emission spectra featured broad tantalate emission and line emissions likely from a rare-earth impurity.

36 MATERIALS SCIENCE↗

Calibration of large neutron detection arrays using cosmic rays

Cosmic muons are used to calibrate the position, light output and the relative timing offset of the Large Area Neutron Array (LANA). Each 2 × 2 m 2 LANA wall consists of twenty-five horizontal neutron detection bars. Each bar is 2 m long with a cross-section of 6.35 × 7.62 cm 2 Pyrex container filled with NE-213 organic scintillation liquid. The average position and time resolution of a bar is found to be about 8 cm and 500 ps FWHM, respectively. Furthermore, our method provides an accurate, fast and convenient calibration of LANA that can be applied to general scintillation arrays without the use of radioactive sources or beams.

79 ASTRONOMY AND ASTROPHYSICS↗

CsI(Tl) pulse shape discrimination with the Belle II electromagnetic calorimeter as a novel method to improve particle identification at electron–positron colliders

Here we describe the implementation and performance of CsI(Tl) pulse shape discrimination for the Belle II electromagnetic calorimeter, representing the first application of CsI(Tl) pulse shape discrimination for particle identification at an electron–positron collider. The pulse shape characterization algorithms applied by the Belle II calorimeter are described. Control samples of $γ, μ^+, π^±, K^±$ and $ρ/ \bar{ρ}$ are used to demonstrate the significant insight into the secondary particle composition of calorimeter clusters that is provided by CsI(Tl) pulse shape discrimination. Comparisons with simulation are presented and provide further validation for newly developed CsI(Tl) scintillation response simulation techniques, which when incorporated with GEANT4 simulations allow the particle dependent scintillation response of CsI(Tl) to be modelled. Comparisons between data and simulation also demonstrate that pulse shape discrimination can be a new tool to identify sources of improvement in the simulation of hadronic interactions in materials. The $K^0_L$ efficiency and photon-as-hadron fake-rate of a multivariate classifier that is trained to use pulse shape discrimination is presented and comparisons are made to a shower-shape based approach. CsI(Tl) pulse shape discrimination is shown to reduce the photon-as-hadron fake-rate by over a factor of 3 at photon energies of 0.2 GeV and over a factor 10 at photon energies of 1 GeV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗