Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “schedules”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Coupling thermal energy storage with a thermally anisotropic building envelope for building demand-side management across various US climate conditions

Here, the thermally anisotropic building envelope (TABE) is a novel active building envelope that enhances energy efficiency and thermal comfort in buildings by transferring heat and cold between building envelopes and hydronic loops. When coupled with thermal energy storage (TES) units, the TABE + TES enables the storage of both heat and cold energy captured by the TABE roof or exterior walls. This stored energy can be later released by the TABE floor for indoor heating and cooling, benefiting both the grid and the end user. This paper evaluates the merits of TABE + TES for building demand-side management across various US climate conditions, focusing on peak load shaving, annual energy savings, and cost savings under time-of-use (TOU) electric rate schedules. Simulations were conducted by integrating time-of-day–informed, rule-based control strategies in MATLAB, TABE components and TES units in COMSOL Multiphysics, and whole-building energy analysis in EnergyPlus. A case study using the US Department of Energy’s prototype single-family detached house model in Birmingham, Alabama; Los Angeles, California; Oak Ridge, Tennessee; and Denver, Colorado, showed that the TABE + TES system achieved (1) 70 % peak load shaving in Los Angeles and Denver and 20 % in Birmingham and Oak Ridge; (2) significant peak electricity savings of 351–497 kWh, reducing peak energy consumption by 38 %–78 %; and (3) annual heating cost savings of 0.79 $\$$/m2–1.17 $\$$/m 2 and cooling cost savings of 0.60 $\$$/m 2 –1.17 $\$$/m 2 using a normal utility rate or low-TOU rate. The benefits of employing the TABE + TES system are even more significant under high TOU rates.

25 ENERGY STORAGE↗

Energy performance of an operational government building retrofitted with ceiling phase change material tiles in a mixed-humid climate

The aging U.S. building stock requires various retrofit measures to enhance their energy efficiency. Here, this study explores the integration of thermal energy storage and advanced building controls as viable retrofit solutions for load flexibility and peak demand response while maintaining the occupants' comfort. A detailed assessment is conducted on the energy use of an administrative building in Sumner County, Kansas, focusing on the implementation of phase change materials (PCMs) in the ceiling of occupied zones. First, a time-resolved, whole-building energy model is developed in EnergyPlus, incorporating complex thermal behaviors such as air exchange between the plenum space and occupied zones, envelope leakage, and operational schedules. The model is then validated using experimental field test data, and subsequently a parametric assessment of key PCM properties and application strategies is performed to evaluate cooling electricity demand benefits. The parametric study shows that the optimal retrofit strategy, comprising a PCM with 23°C peak melting temperature, 0.125 in. (3.17 mm) thickness, and 150 kJ/kg latent heat, combined with active controls that include 8 h of precooling, forced convection under the ceiling, and a 2°C thermostat setback during peak hours, can result in a maximum load shift during the peak period of 99.6 % and the total electricity savings during the peak period of 98.9 % for the optimum case and thus provide significant cost savings under time-of-use pricing scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Machine learning-enhanced MPC for demand flexibility in small commercial buildings: An experimental study

Small- and medium-sized commercial buildings (SMCBs) represent the majority of U.S. commercial building stock and a significant share of peak electricity demand, yet they often lack centralized building automation systems, representing a significant untapped resource for urban energy management. This infrastructure gap makes advanced control implementation challenging, limiting the potential for widespread demand flexibility. Model Predictive Control (MPC) has shown strong potential for load shifting, peak demand reduction, and cost savings, but its effectiveness is hindered by unmeasured disturbances such as internal heat gains. This paper presents a Hybrid MPC framework that integrates a physics-based gray-box building thermal model, identified using a lumped disturbance (LD) approach, with a machine learning (ML) model for forecasting unmeasured disturbances. The hybrid approach is designed for buildings with multiple individually controlled heat pump and thermostat pairs, common in SMCBs, and aims to optimize coordinated scheduling of multiple heat pumps under dynamic electricity pricing while respecting comfort constraints. The methodology is validated through both simulations of case study buildings and experimental studies at a highly-instrumented test facility. Simulation results show that the Hybrid MPC achieves substantial load shifting and peak demand reduction, approaching the performance of an ideal MPC with perfect disturbance knowledge, and outperforming a conventional MPC without disturbance forecasting. In experiments, the Hybrid MPC reduced daily HVAC energy costs by 8.7%, peak-price time load (load shifting) by 41.7%, and peak demand by 29.2% compared to baseline control, demonstrating comparable benefits to the 11.6% cost savings, 42.9% load shifting, and 23.2% peak reduction of the ideal MPC. These results demonstrate that the proposed hybrid modeling approach can significantly improve MPC performance in real-world SMCB applications without requiring additional disturbance measurements.

Demand Flexibility↗

Envelope-driven comfort risk in residential demand response

Residential demand response (DR) is a valuable resource for grid reliability, but remains challenging because the highly heterogeneous residential building stock leads to widely varying and hard-to-predict load and comfort responses during DR events. Although prior research has estimated the technical potential of DR-capable technologies for achieving energy demand savings, little is known about how they affect thermal comfort. In particular, it remains unclear how indoor thermal conditions due to DR depend on the thermal envelope characteristics of the housing stock. To address this gap, this study provides a systematic, location-specific assessment of indoor thermal performance during DR-events across the US housing stock using both typical DR weather data and detailed building metadata. We evaluate how envelope characteristics influence indoor temperatures during realistic simulated summer and winter DR events across 37 US locations, applying both temperature threshold and rate of temperature change criteria to estimate region-level probabilities of discomfort. Additionally, we show the impact of distinct weather patterns that intensify or abate thermal stress on comfort outcomes. Results show a near-universal overheating risk in summer DR events, where comfort outcomes are strongly influenced by rapid risk of comfort violations. In contrast, overall winter DR discomfort risk is lower, risk escalation is more gradual and shows greater sensitivity to event duration. These findings offer a data-driven quantification of comfort risk across diverse climates and building envelopes, demonstrating the need for region-specific DR scheduling and discomfort mitigation strategies tailored to local weather patterns and the performance of existing residential buildings.

Demand response↗

Off-design performance of molten salt-driven Rankine cycles and its impact on the optimal dispatch of concentrating solar power systems

This paper presents a model for improving off-design performance predictions for molten salt-driven Rankine power cycles, such as in concentrating solar power tower applications. The model predicts cycle off-design performance under various boundary conditions, including molten salt inlet temperature, mass flow rate, and ambient temperature. The model is validated using industry performance data and benchmarked with results from the literature. A complete concentrating solar power plant, inclusive of solar heliostat field and receiver, is then considered, by implementing the Rankine cycle off-design performance results into the National Renewable Energy Laboratory’s System Advisor Model software, which includes a tool that determines optimal power production schedules. The work improves upon the current System Advisor Model by updating off-design performance characteristics. A case study demonstrates the impact of cycle off-design behavior on annual performance for a stand-alone concentrating solar power system and a concentrating solar power-photovoltaic hybrid system. In addition, we demonstrate how cycle off-design performance influences optimal operator dispatch decisions and, thereby, overall system design and economics. We conclude that off-design cycle performance impacts “optimal” sub-system sizing, especially for a concentrating solar power-photovoltaic hybrid configuration in which concentrating solar power must dispatch in conjunction with photovoltaic generation.

14 SOLAR ENERGY↗

Optimal operation of solid-oxide electrolysis cells considering long-term chemical degradation

Optimizing the performance of solid oxide electrolysis cells (SOECs) for long-term hydrogen (H 2 ) production at high temperatures is crucial, as prolonged operation leads to efficiency losses and shorter cell lifespans due to chemical degradation. Here, in this work, we adopt a quasi-steady state approach for dynamic optimization over extended operational periods to address the disparity in timescales between cell operation and degradation. Integrating a 2-D non-isothermal SOEC model with balance-of-plant (BOP) equipment, we explore three optimization objectives: minimizing terminal degradation, maximizing integral efficiency, and minimizing the levelized cost of H 2 (LCOH). Our dynamic optimization algorithm reduces LCOH by 9.5% and 16% compared to strategies focusing solely on terminal degradation and integral efficiency, respectively. For electricity prices of 0.03 $\$$/mWh and 0.3 $\$$ mWh optimal replacement schedules range from 5 to 2 years, depending on the operational mode. Furthermore, a flexible operational mode yields additional improvements in LCOH over traditional galvanostatic and potentiostatic modes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optimal sizing of battery energy storage systems for peak shaving and demand response using a degradation-aware Bayesian Optimization-Mixed-Integer Linear Programming framework

The increasing integration of renewable energy and rising electricity demand highlight the importance of battery energy storage systems for peak shaving and demand response. Unlike prior approaches that overlook operational impacts on degradation, this study proposes a Bayesian Optimization–Mixed Integer Linear Programming framework for optimal battery energy storage system sizing. In this framework, Mixed Integer Linear Programming determines short-term scheduling while a calibrated electrochemical model iteratively evaluates degradation. The central hypothesis is that the framework can efficiently identify optimal sizes that yield realistic and economically robust outcomes. The method is tested across three scenarios: peak shaving, peak shaving with energy-reduction demand response, and peak shaving with power-reduction demand response. Results show that the framework converge to the optimum within 20 iterations out of 150 possible sizes. Under baseline conditions, the framework consistently selects the smallest feasible system, minimizing unnecessary degradation costs from oversized storage. Sensitivity analyses reveal that larger systems are favored as demand rates or incentives increase. Comparisons of demand response programs indicate that power-reduction demand response offers greater economic benefits than energy-reduction demand response, although demand savings from peak shaving remain the dominant contributor to overall performance. This study demonstrates that the proposed framework balances computational tractability with degradation fidelity, identifies critical economic thresholds for investment, and offers a practical, flexible tool to guide industrial stakeholders in cost-effective battery energy storage system deployment.

Batteries↗

Energy-efficient multimodal mobility networks in transportation digital twins: Strategies and optimization

The study proposes a comprehensive Transportation Mobility (TransitMo) framework covering conceptual design, model formulation, optimization, simulation, and impact analysis of the transportation mobility system. TransitMo is composed of a transportation digital twin developed in Simulation of Urban MObility (SUMO) and an Intelligent Traffic Management and Control Center (ITMCC) that identifies the best ways to improve the movement of people within urban areas using various modes of transportation. This study encompasses advanced modeling techniques, algorithms, and strategic testing to optimize energy efficiency and mobility in a multimodal shared mobility network. TransitMo’s practical applications are exemplified through a city-scaled simulation network in Chattanooga, TN, employing demographic data to analyze historical traffic patterns and forecast future demands. Central to this methodology are three models: the User Preference Model (UP), the Energy Consumption Model (EC), and the System Optimization Model (SO). These models work in concert to iteratively devise the optimal travel incentives and minimize the total system cost in a real-time manner. In conclusion, test results verified that the proposed adaptive incentive program and optimized bus scheduling can improve network performance by increasing public transit ridership.

42 ENGINEERING↗

Exploratory analysis and performance prediction of big data transfer in High-performance Networks

Big data transfer in large-scale scientific and business applications is increasingly carried out over connections with guaranteed bandwidth provisioned in High-performance Networks (HPNs) via advance bandwidth reservation. Provisioning agents need to carefully schedule data transfer requests, compute network paths, and allocate appropriate bandwidths. Such reserved bandwidths, if not fully utilized, could be simply wasted due to the exclusive access during the approved time window, and cause extra overhead and complexity for resource management. This calls for accurate performance prediction to reserve bandwidths that match actual needs and avoid over-provisioning. We employ machine learning algorithms to predict big data transfer performance based on extensive performance measurements collected in the past several years from data transfer tests using different protocols and toolkits between various end sites on several real-life physical or emulated testbeds. We first analyze the performance patterns in response to a comprehensive list of parameters in end-host systems, network connections, and data transfer applications, which motivate the use of machine learning and also help us identify the effects of latent factors. We then propose threshold- and clustering-based methods to eliminate negative effects of latent factors in data preprocessing and build a robust performance predictor based on customized domain-oriented loss functions. The performance of the proposed methods is verified by extensive experiments using SVR and RFR as well as theoretical analysis of the general performance bound.

97 MATHEMATICS AND COMPUTING↗

City-level impacts of building tune-ups: Findings from Seattle's building tune-ups program

Many U.S. cities are implementing policies to reduce greenhouse gas (GHG) emissions of their buildings. These range from building energy benchmarking and disclosure to building performance standards (BPS) that require buildings to meet specific targets of energy use or emissions. The City of Seattle adopted a climate action plan in 2013 that set a goal of zero net GHG emissions in the road transportation, buildings, and waste sectors by 2050, with a number of near and long term actions. Seattle implemented mandatory building tune-ups in 2016, applying to commercial buildings larger than 50,000 sqft. Building tune-ups1 involve assessment and implementation of operational and maintenance (O + M) improvements to achieve energy and water efficiency, such as changes to thermostat set points or adjusting lighting or irrigation schedules. Seattle's tune-ups program covered 27 such improvements in HVAC, lighting, domestic hot water, and envelope systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Stochastic DC optimal power flow with reserve saturation

We propose an optimization framework for stochastic optimal power flow with uncertain loads and renewable generator capacity. Our model follows previous work in assuming that generator outputs respond to load imbalances according to an affine control policy, but introduces a model of saturation of generator reserves by assuming that when a generator’s target level hits its limit, it abandons the affine policy and produces at that limit. This is a particularly interesting feature in models where wind power plants, which have uncertain upper generation limits, are scheduled to provide reserves to balance load fluctuations. Here, the resulting model is a nonsmooth nonconvex two-stage stochastic program, and we use a stochastic approximation method to find stationary solutions to a smooth approximation. Computational results on 6-bus and 118-bus test instances demonstrate that by considering the effects of saturation, our model can yield solutions with lower expected generation costs (at the same target line violation probability level) than those obtained from a model that enforces the affine policy to stay within generator limits with high probability.

17 WIND ENERGY↗

Modeling the AC Power Flow Equations with Optimally Compact Neural Networks: Application to Unit Commitment

Nonlinear power flow constraints render a variety of power system optimization problems computationally intractable. Emerging research shows, however, that the nonlinear AC power flow equations can be successfully modeled using neural networks. These neural networks can be exactly transformed into mixed integer linear programs and embedded inside challenging optimization problems, thus replacing nonlinearities that are intractable for many applications with tractable piecewise linear approximations. Such approaches, though, suffer from an explosion of the number of binary variables needed to represent the neural network. Accordingly, this paper develops a technique for training an "optimally compact'' neural network, i.e., one that can represent the power flow equations with a sufficiently high degree of accuracy while still maintaining a tractable number of binary variables. We demonstrate the use of this neural network as an approximator of the nonlinear power flow equations by embedding it in the AC unit commitment problem, transforming the problem from a mixed integer nonlinear program into a more manageable mixed integer linear program. We use the 14-, 57-, and 89-bus networks as test cases and compare the AC-feasibility of commitment decisions resulting from the neural network, DC, and linearized power flow approximations. Our results show that the neural network model outperforms both the DC and linearized power flow approximations when embedded in the unit commitment problem. The neural network formulation most often selects a feasible unit commitment schedule, and furthermore, it only s

AC power flow↗

Real-time hybrid controls of energy storage and load shedding for integrated power and energy systems of ships

This paper presents an original energy management methodology to enhance the resilience of ship power systems. The integration of various energy storage systems (ESS), including battery energy storage systems (BESS) and super-capacitor energy storage systems (SCESS), in modern ship power systems poses challenges in designing an efficient energy management system (EMS). The EMS proposed in this paper aims to achieve multiple objectives. The primary objective is to minimize shed loads, while the secondary objective is to effectively manage different types of ESS. Considering the diverse ramp-rate characteristics of generators, SCESS, and BESS, the proposed EMS exploits these differences to determine an optimal long-term schedule for minimizing shed loads. Furthermore, the proposed EMS balances the state-of-charge (SoC) of ESS and prioritizes the SCESS’s SoC levels to ensure the efficient operation of BESS and SCESS. For better computational efficiency, we introduce the receding horizon optimization method, enabling real-time EMS implementation. Further, a comparison with the fixed horizon optimization (FHO) validates its effectiveness. Simulation studies and results demonstrate that the proposed EMS efficiently manages generators, BESS, and SCESS, ensuring system resilience under generation shortages. Additionally, the proposed methodology significantly reduces the computational burden compared to the FHO technique while maintaining acceptable resilience performance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

From roads to roofs: How urban and rural mobility influence building energy consumption

In this article, understanding the relationship between travel behavior and building energy use at an urban scale is crucial for developing effective energy management strategies. Mobility patterns significantly impact building occupancy, which in turn affects energy consumption. However, existing methods often focus on individual buildings, whereas geographical influences on energy usage are not adequately examined. This study addresses this gap by using transportation origin-destination (OD) data to estimate building occupancy and energy. The proposed method assigns OD trips from census block groups to the building level, incorporating building, travel survey, and census data to derive building occupancy profiles. This method was applied to urban and rural areas with 4062 buildings in 70 census block groups. We found that the OD-informed occupancy profile exhibits smoother energy consumption patterns compared with that of Department of Energy reference occupancy profiles. Our analysis reveals distinct building energy consumption patterns among groups with long and short commutes, emphasizing the effect of commute times and work schedules on residential energy usage. This framework is useful for practitioners in transportation agencies and utility companies, enabling the estimation of building energy based on mobility patterns. Overall, this study shows the potential of integrating transportation and building energy data to inform cross-sector energy management strategies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dispatch optimization of electric thermal energy storage within System Advisor Model

A stand-alone electric thermal energy storage (ETES) system converts low-value electricity into heat using resistance heating elements. During periods of high-value electricity, an ETES system uses a thermodynamic power cycle to convert stored thermal energy back to electricity. These dispatchable systems derive value from their ability to store energy when prices are low and generate electricity when prices are favorable, i.e., energy arbitrage. Consequently, dispatch optimization of system operations, through maximizing revenue subject to system constraints, is essential to evaluate the economic value of a particular system design. While stand-alone ETES systems offer potential advantages as dispatchable grid storage technologies, there is a lack of a neutral third-party, publicly available, open-source model to evaluate the performance, dispatch, and financial viability of these systems. To address this problem, we have developed a techno-economic model for stand-alone ETES systems, within National Renewable Energy Laboratory's (NREL's) System Advisor Model (SAM). We implement a mixed-integer linear program to determine an ETES optimal operating schedule that maximizes electricity sales less maintenance costs caused by operation and cycling given temporal-varying grid electricity prices. Our contributions include a mixed-integer linear program for energy arbitrage of an ETES system, an ETES performance model through a publicly-available software (i.e., SAM), and an exercise of our model through case studies that compare ETES operational strategies and annual financial metrics. With our dispatch optimization model, we were able to improve revenue by 20% compared to a myopic heuristic while reducing the operational cost of the ETES system through decreases in cycle starts, cycles per day, and heater starts.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Air compressor load forecasting using artificial neural network

Air compressor systems are responsible for approximately 10% of the electricity consumed in United States and European Union industry. As many researches have proven the effectiveness of using Artificial Neural Network inair compressor performance prediction, there is still a need to forecast the air compressor electrical load profile. The objective of this study is to predict compressed air systems’ electrical load profile, which is valuable to industry practitioners as well as software providers in developing better practice and tools for load managementand look-ahead scheduling programs. Two artificial neural networks, Two-Layer Feed-Forward Neural Networkand Long Short-Term Memory were used to predict an air compressors electrical load. Compressors with three different control mechanisms are evaluated with a total number of 11,874 observations. Here, the forecasts were validated using out-of-sample datasets with 5-fold cross-validation. Models produced average coefficient ofdetermination values from 0.24 to 0.94, average root-mean-square errors from 0.05 kW - 5.83 kW, and meanabsolute scaled errors from 0.20 to 1.33. The results indicate that both artificial neural networks yield goodresults for compressors using variable speed drive (average R 2 = 0.8 and no naïve forecasting), only the longshort-term memory model gives acceptable results for compressors using on/off control (average R 2 = 0.82 and no naïve forecasting), and no satisfactory results are obtained for load/unload type air compressors (models constituting active forecasting).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Aerial drone fleet deployment optimization with endogenous battery replacements for direct delivery of time-sensitive products

Aerial drones offer a distinct potential to reduce the delivery time and energy consumption for the delivery of time-sensitive and small products. However, there is still a need in the relevant industry to understand the performance of drone-based delivery under different business needs and drone operating conditions. We studied a drone deployment optimization problem for direct delivery of time-sensitive products with release dates to customers maintaining a specified time window. This paper presents a new mixed-integer programming model, new valid inequalities, a new greedy heuristic algorithm, and a Genetic algorithm to help business owners optimally schedule and route their drone fleet minimizing the required fleet size, the required number of additional batteries, and total energy consumption. A realistic feature of the optimization method is that instead of replacing the drone battery after each return to the depot, it keeps track of the remaining energy in the drone battery and decides on battery replacements accounting for the drone routing and the user-specified minimum required battery energy. Numerical results based on real data from drone flight tests and prepared food delivery industry provide insights into the effect of different practical drone operating parameters on the required fleet size, the required number of battery replacements, and energy consumption. Here, results demonstrate that the proposed heuristic algorithm substantially outperforms the accelerated CPLEX in runtime while sacrificing the solution quality by a small amount. Additionally, results show that using a mixed fleet of hexacopter and quadcopter drones reduces the total energy consumption by 48.52% compared to using a homogeneous fleet of only hexacopters.

Drone energy consumption↗