Collisionality dependence and ion species effects on heat transport in He and H plasma, and the role of ion scale turbulence in LHD

Here, surveys of the ion and electron heat transports of neutral beam (NB) heating plasma were carried out by power balance analysis in He and H rich plasma at LHD. Collisionality was scanned by changing density and heating power. The characteristics of the transport vary depending on collisionality. In low collisionality, with low density and high heating power, an ion internal transport barrier (ITB) was formed. The ion heat conductivity (χ i ) is lower than electron heat conductivity (χ e ) in the core region at ρ < 0.7. On the other hand, in high collisionality, with high density and low heating power, χ i is higher than χ e across the entire range of plasma. These different confinement regimes are associated with different fluctuation characteristics. In ion ITB, fluctuation has a peak at ρ = 0.7, and in normal confinement, fluctuation has a peak at ρ = 1.0. The two confinement modes change gradually depending on the collisionality. Scans of concentration ratio between He and H were also performed. The ion confinement improvements were investigated using gyro-Bohm normalization, taking account of the effective mass and charge. The concentration ratio affected the normalized χ i only in the edge region (ρ ~ 1.0). This indicates ion species effects vary depending on collisionality. Turbulence was modulated by the fast ion loss instability. The modulation of turbulence is higher in H rich than in He rich plasma.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Simultaneous translational temperature measurements of different atomic species in plasma flows using scanning Fabry-Perot interferometry

A revised scientific instrument to measure simultaneously kinetic temperatures of different atoms from their optical emission profile is reported. Emission lines are simultaneously detected using one single scanning Fabry-Perot-interferometer (FPI) for a combined spectroscopic setup to acquire different emission lines simultaneously. The setup consists in a commercial Czerny-Turner spectrometer configuration which is combined with a scanning Fabry-Perot interferometer. The fast image acquisition mode of an intensified charge coupled device camera allows the detection of a wavelength interval of interest continuously while acquiring the highly resolved line during the scan of the FPI ramp. Results using this new setup are presented for the simultaneous detection of atomic nitrogen and oxygen in a high enthalpy air plasma flow as used for atmospheric re-entry research and their respective kinetic temperatures derived from the measured line profiles. The paper presents the experimental setup, the calibration procedure, and an exemplary result. The determined temperatures are different, a finding that has been published so far as due to a drawback of the experimental setup of sequential measurements, and which has now to be investigated in more detail.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scanning secondary-electron microscopy on ferroelectric domains and domain walls in YMnO{sub 3}

Ferroelectric domain structures in YMnO{sub 3} single crystals on the hexagonal polar surface have been investigated by scanning electron microscopy in secondary electron emission mode. The experimental results demonstrate that the domain, as well as domain walls, can be clearly revealed under the operation voltages ranging from 0.6 to 3 kV. Evolution of domain contrasts arising from electron-beam irradiation can be mainly explained by the pyroelectric effect and related charging process. A rich variety of microstructure features of ferroelectric domains can be clearly revealed in YMnO{sub 3} by this high-resolution technique.

36 MATERIALS SCIENCE↗

Creep-rupture performance of 0.07C-23Cr-45Ni-6W-Ti,Nb austenitic alloy (HR6W) tubes

A series of base metal and cross-weld creep-rupture tests were conducted on the advanced austenitic alloy, HR6W, to evaluate the material for use at advanced ultrasupercritical (A-USC) steam conditions. Creep deformation and rupture were evaluated by traditional methods and data were compared with other studies to evaluate the creep response of the material. Optical and scanning electron microscopy revealed changes in failure mode and precipitation behavior. Thermodynamic predictions of phase stability were conducted and the results were compared with the experimental data. This research confirmed the important role of W and the precipitation of laves phase in the alloy system, but a direct relationship between laves phase content and creep strength was not observed. Furthermore, Cr content was investigated as an additional factor which may be important in the microstructural stability of the alloy which had not been previously considered. Finally, when compared to commercially available stainless steels, this heat of HR6W showed no creep strength advantage for A-USC application.

36 MATERIALS SCIENCE↗

Electron temperature gradient driven transport model for tokamak plasmas

A new model for electron temperature gradient (ETG) modes is developed as a component of the multi-mode anomalous transport module [Rafiq et al., Phys Plasmas 20, 032506 (2013)] to predict a time-dependent electron temperature profile in conventional and low aspect ratio tokamaks. This model is based on two-fluid equations that govern the dynamics of low-frequency short- and long-wavelength electromagnetic toroidal ETG driven drift modes. A low collisionality NSTX discharge is used to scan the plasma parameter dependence on the ETG real frequency, growth rate, and electron thermal diffusivity. Electron thermal transport is discovered in the deep core region where modes are more electromagnetic in nature. Several previously reported gyrokinetic trends are reproduced, including the dependencies of density gradients, magnetic shear, β and gradient of β (β'), collisionality, safety factor, and toroidicity, where β is the ratio of the plasma pressure to the magnetic pressure. Furthermore, the electron heat diffusivity associated with the ETG mode is discovered to be on a scale consistent with the experimental diffusivity determined by power balance analysis.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electron Temperature Gradient Driven Transport Model for Tokamak Plasmas

A new model for electron temperature gradient (ETG) modes is developed as a component of the Multi-Mode anomalous transport module [T. Rafiq \textit{et al.,} Phys Plasmas \textbf{20}, 032506 (2013)] to predict a time dependent electron temperature profile in conventional and low aspect ratio tokamaks. This model is based on two-fluid equations that govern the dynamics of low-frequency short- and long-wavelength electromagnetic toroidal ETG driven drift modes. A low collisionality NSTX discharge is used to scan the plasma parameter dependence on the ETG real frequency, growth rate, and electron thermal diffusivity. Electron thermal transport is discovered in the deep core region where modes are more electromagnetic in nature. Several previously reported gyrokinetic trends are reproduced, including the dependencies of density gradients, magnetic shear, $\beta$ and gradient of $\beta$ $(\betap)$, collisionality, safety factor, and toroidicity, where $\beta$ is the ratio of plasma pressure to the magnetic pressure. The electron heat diffusivity associated with the ETG mode is discovered to be on a scale consistent with the experimental diffusivity determined by power balance analysis.

ETG↗

Evidence of a distinct collective mode in Kagome superconductors

The collective modes of the superconducting order parameter fluctuation can provide key insights into the nature of the superconductor. Recently, a family of superconductors has emerged in non-magnetic kagome materials AV 3 Sb 5 (A = K, Rb, Cs), exhibiting fertile emergent phenomenology. However, the collective behaviors of Cooper pairs have not been studied. Here, we report a distinct collective mode in CsV 3-x Ta x Sb 5 using scanning tunneling microscope/spectroscopy. The spectral line-shape is well-described by one isotropic and one anisotropic superconducting gap, and a bosonic mode due to electron-mode coupling. With increasing x, the two gaps move closer in energy, merge into two isotropic gaps of equal amplitude, and then increase synchronously. The mode energy decreases monotonically to well below 2Δ and survives even after the charge density wave order is suppressed. We propose the interpretation of this collective mode as Leggett mode between different superconducting components or the Bardasis-Schrieffer mode due to a subleading superconducting component.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Molecular beam epitaxy of bilayer Bi(111) films on topological insulator Bi{sub 2}Te{sub 3}: A scanning tunneling microscopy study

We report on molecular beam epitaxy growth of bilayer Bi(111) films on topological insulator Bi{sub 2}Te{sub 3}. In situ scanning tunneling microscopy/spectroscopy shows that Bi growth mode changes from quasi bilayer-by-bilayer to step-flow with increasing substrate temperature. Bilayer Bi(111) exhibits an electron donor behavior, causing an 80 meV downshift of the Dirac point of Bi{sub 2}Te{sub 3}. Local work function difference between the bilayer films and Bi{sub 2}Te{sub 3} films is measured to be 390 meV. Based on the observations, we propose a schematic energy-band diagram which reveals band bending effect at the Bi/Bi{sub 2}Te{sub 3} interface. Our work paves a way to explore the exotic topological properties of bilayer islands and thin films of Bi.

36 MATERIALS SCIENCE↗

Kilovoltage Imaging Doses in the Radiotherapy of Pediatric Cancer Patients

Purpose: To investigate doses induced by kilovoltage cone-beam computed tomography (kVCBCT) to pediatric cancer patients undergoing radiotherapy, as well as strategies for dose reduction. Methods and Materials: An EGS4 Monte Carlo code was used to calculate three-dimensional dose deposition due to kVCBCT on 4 pediatric cancer patients. Absorbed doses to various organs were analyzed for both half-fan and full-fan modes. Clinical conditions, such as distance from organ at risk (OAR) to CBCT field border, kV peak energy, and testicular shielding, were studied. Results: The mean doses induced by one CBCT scan operated at 125 kV in half-fan mode to testes, liver, kidneys, femoral heads, spinal cord, brain, eyes, lens, and optical nerves were 2.9, 4.7, 7.7, 10.5, 8.8, 7.6, 7.7, 7.8, and 7.2 cGy, respectively. Increasing the distances from OARs to CBCT field border greatly reduced the doses to OARs, ranging from 33% reduction for spinal cord to 2300% reduction for testes. As photon beam energy increased from 60 to 125 kV, the dose increase due to kVCBCT ranged from 170% for lens to 460% for brain and spinal cord. A testicular shielding made of 1-cm cerrobend could reduce CBCT doses down to 31%, 51%, 68%, and 82%, respectively, for 60, 80, 100, and 125 kV when the testes lay within the CBCT field. Conclusions: Generally speaking, kVCBCT deposits much larger doses to critical structures in children than in adults, usually by a factor of 2 to 3. Increasing the distances from OARs to CBCT field border greatly reduces doses to OARs. Depending on OARs, kVCBCT-induced doses increase linearly or exponentially with photon beam energy. Testicular shielding works more efficiently at lower kV energies. On the basis of our study, it is essential to choose an appropriate scanning protocol when kVCBCT is applied to pediatric cancer patients routinely.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dissociation pathways of a single dimethyl disulfide on Cu(111): Reaction induced by simultaneous excitation of two vibrational modes

We present a novel reaction mechanism for a single adsorbed molecule that proceeds via simultaneous excitation of two different vibrational modes excited by inelastic tunneling electrons from a scanning tunneling microscope. Specifically, we analyze the dissociation of a single dimethyl disulfide (DMDS, (CH{sub 3}S){sub 2}) molecule on Cu(111) by using a versatile theoretical method, which permits us to simulate reaction rates as a function of sample bias voltage. The reaction is induced by the excitation of C-H stretch and S-S stretch modes by a two-electron process at low positive bias voltages. However, at increased voltages, the dissociation becomes a single-electron process that excites a combination mode of these stretches, where excitation of the C-H stretch is the energy source and excitation of the S-S stretch mode enhances the anharmonic coupling rate. A much smaller dissociation yield (few orders of magnitude) at negative bias voltages is understood in terms of the projected density of states of a single DMDS on Cu(111), which reflects resonant excitation through the molecular orbitals.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-E-J-271: A Feasibility Study to Utilize XR-QA2 Radiochromic Films as An Alternative Tool for Measuring Beam Parameters of Kilovoltage CBCT Systems

Purpose: The beam parameters of the x-ray beams used in image guidance are difficult to measure in water due to the low exposure. This study is to investigate if XR-QA2 radiochromic films can be used in obtaining beam parameters, such as beam profiles and outputs for kV-CBCT systems. Methods: The kV-CBCT beams were from a Varian OBI system. The films used were XR-QA2-GAFCHROMICTM films placed in the middle of two Plastic -Water slab phantoms at isocenter. The scanner used to analyze the films was an Epson Expression 1680 flat-bed scanner. Pre and 24 h-post-irradiated scans of films were obtained by using the reflective mode. The corresponding pixel-by-pixel dose in the films was obtained using a dose calibration equation as a function of net reflectance from the literature. Beam profiles of different scan protocols with and without bow-tie filters were measured. Monte Carlo simulations were used to compare the accuracy of the measured dose profiles. Results: The beam profiles measured from XR-QA2 films for different clinical default kV-CBCT scan protocols were benchmarked against Monte Carlo simulated profiles which have been validated by measurements performed in water phantom. We confirmed that a minimum post-irradiated time of 24 hours is necessary to pass to scan the films to account for light scatter stability. We found that the uncertainties of the results depend on the scan orientation of the film when analyzed in different directions. Conclusion: The XR-QA2 radiochromic films are sensitive to measure the x-ray beam profiles with irradiated dose ranging 1–5 cGy. The film measurements can be performed with an easy setup compared to ion chamber measurements in a water phantom. These films provide an alternative method to obtain the beam profiles for kV-CBCT beams.

60 APPLIED LIFE SCIENCES↗

Domain formation due to surface steps in topological insulator Bi{sub 2}Te{sub 3} thin films grown on Si (111) by molecular beam epitaxy

The atomic structure of topological insulators Bi{sub 2}Te{sub 3} thin films on Si (111) substrates grown in van der Waals mode by molecular beam epitaxy has been investigated by in situ scanning tunneling microscopy and scanning transmission electron microscopy. Besides single and multiple quintuple layer (QL) steps, which are typical for the step-flow mode of growth, a number of 0.4 QL steps is observed. We determine that these steps originate from single steps at the substrate surface causing domain boundaries in the Bi{sub 2}Te{sub 3} film. Due to the peculiar structure of these domain boundaries the domains are stable and penetrate throughout the entire film.

36 MATERIALS SCIENCE↗

Synchrotron-based X-ray fluorescence imaging and elemental mapping from biological samples

The present study utilized the new hard X-ray microspectroscopy beamline facility, X27A, available at NSLS, BNL, USA, for elemental mapping. This facility provided the primary beam in a small spot of the order of {approx}10 {mu}m, for focussing. With this spatial resolution and high flux throughput, the synchrotron-based X-ray fluorescent intensities for Mn, Fe, Zn, Cr, Ti and Cu were measured using a liquid-nitrogen-cooled 13-element energy-dispersive high-purity germanium detector. The sample is scanned in a 'step-and-repeat' mode for fast elemental mapping measurements and generated elemental maps at 8, 10 and 12 keV, from a small animal shell (snail). The accumulated trace elements, from these biological samples, in small areas have been identified. Analysis of the small areas will be better suited to establish the physiology of metals in specific structures like small animal shell and the distribution of other elements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantification of the carbon bonding state in amorphous carbon materials: A comparison between EELS and NEXAFS measurements

In this report the quantitative determination of the carbon hybridization is critical for establishing processing-structure-properties relationships for carbon-based materials, including amorphous carbon coatings. While several techniques have been employed to characterize the amount of sp 2 and sp 3 carbon in these materials, direct comparisons between analytical results are limited. Here, we compare near edge X-ray absorption fine structure (NEXAFS) spectra of a silicon- and oxygen-containing hydrogenated amorphous carbon (a-C:H:Si:O) coating acquired in synchrotron-based scanning transmission X-ray microscopy (STXM) mode with electron energy loss spectra (EELS) obtained from the same a-C:H:Si:O lamella. While the fractions of sp 2 carbon computed from STXM and EELS spectra are in close agreement, the comparison of NEXAFS spectra acquired in STXM mode with NEXAFS spectra collected in partial electron yield mode on a flat a-C:H:Si:O surface indicated that the destructive preparation of thin lamellae for STXM analyses induces variations in the structure of a-C:H:Si:O, namely the breakage of carbon-silicon and carbon-hydrogen bonds, a change in ordering of sp 2 -bonded carbon, and an increase in the sp 2 carbon fraction. These findings can help scientists in the careful interpretation of spectroscopic results obtained from the analysis of samples made of metastable materials after the destructive preparation of specimens for analytical purposes.

36 MATERIALS SCIENCE↗

Resistance of concrete to different exposures with chloride-based salts

Formation of complex salts (oxychlorides) has been suspected for causing chemical degradation of concrete in cold regions. In this study, conditioned mode (controlled temperature and relative humidity) environmental scanning electron microscopy was specifically used to minimize changes in the crystal structures of oxychlorides phases and thus reliably capture their unaltered morphology and existence/effects on concrete exposed to different de-icing salts under two different environmental conditions (constant low temperature and wetting/drying (W/D) cycles). Formation of acicular flattened blades of 3- and 5-form magnesium oxychloride (MOX) and tiny fibrous crystals as well as subhedral pseudo-hexagonal calcium oxychloride plates (COX) were found in deteriorated concrete specimens, depending on the type of solution. The reversible formation of hydrous and anhydrous COX during W/D cycles had a significant effect on aggravating the kinetics of damage of concrete in this exposure. The combined salt (MgCl{sub 2} + CaCl{sub 2}), which simulates using a synergistic maintenance and protective strategy for concrete pavements in winter, was the most aggressive solution; thus, this practice should be cautiously reconsidered. The incorporation of 30% fly ash had a pronounced effect on improving the concrete resistance to damage as reflected by sound mechanical properties and longevity. Also, the performance of concrete was much enhanced when an innovative supplementary cementitious material, nanosilica, was incorporated in the cementitious system.

36 MATERIALS SCIENCE↗

Investigation of the Distribution of Elements in Snail Shell With the use of Synchrotron-Based, Micro-Beam X-ray Fluorescence Spectrometry

In this study, synchrotron-based micro-beam was utilized for elemental mapping of a small animal shell. A thin X-ray spot of the order of {approx}10 em was focused on the sample. With this spatial resolution and high flux throughput, the X-ray fluorescent intensities for Ca, Mn, Fe, Ni, Zn, Cr and Cu were measured using a liquid-nitrogen-cooled 13-element energy-dispersive HpGe detector. The sample is scanned in a estep-and-repeat' mode for fast elemental mapping and generated elemental maps at 8, 10 and 12 keV. All images are of 10 em resolution and the measurement time was 1 s per point. The accumulation of trace elements was investigated from the soft-tissue in small areas. Analysis of the small areas will be better suited to establish the physiology of metals in specific structures like small animal shell and the distribution of other trace elements.

59 BASIC BIOLOGICAL SCIENCES↗

Studies of various physics effects on an on-axis LHCD experiment using numerical tools

The lower hybrid current drive (LHCD) plays an important role in the long pulse and high performance experiments on the EAST Tokamak, using LHW systems with frequencies of 2.45 GHz and 4.6 GHz. With the initial parallel refractive index mostly peaking at n ∥ ~1.8-2.1, it is difficult to have on-axis LHCD due to the accessibility conditions which prevents the LHW from propagating into the plasma core. However, according to the investigation of HXR diagnostics, LHW did provide an on-axis current drive in an EAST experiment. To interpret this on-axis LHCD phenomenon, various physics effects that give rise to variations in parallel wave numbers, thus influencing the propagation and the absorption of the LHW, have been taken into account, such as toroidal effects, full wave effects with focusing and diffraction, and scattering effects due to density fluctuations. Numerical tools including ray-tracing and full wave codes that contain one or two of the above physics effects have been used to model the heating and current drive of the LHW on EAST. Linear Landau damping and quasi-linear Landau damping have been compared by using the coupling between ray-tracing and the Fokker-Planck codes. Convergence studies have been performed for the full wave modeling, the maximum poloidal modes in the full wave have been scanned, and the results are compared with each other. The factors that characterize the amplitude, the radial thickness, and the location of the density fluctuations have been studied and scanned. The measurement of HXR diagnostics has been compared with synthetic diagnostics by reconstructing the HXR data from both the standard GENRAY/CQL3D LHCD modelling and the modeling taking the scattering effects into account.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Demonstration of reconstruction-free static magnetic control of DIII-D plasma with deep reinforcement learning

This paper presents the development and experimental validation of a reinforcement learning (RL)-based magnetic controller on the DIII-D tokamak. The controller directly maps raw magnetic diagnostic signals to actuator commands, replacing the traditional isoflux control algorithm based on equilibrium reconstruction. Four RL controllers are trained using the Soft Actor–Critic algorithm with an asymmetric Actor–Critic architecture in the NSFsim simulator. All controllers are deployed in the DIII-D Plasma Control System and operated with a 4 kHz feedback loop. Two randomization strategies are evaluated during training: evolving kinetic profiles and fixed kinetic profiles within each episode. The latter approach is found to better capture experimental deviations in the current density profile and to provide overall improved control performance. Robust operation is demonstrated across heating power scans in both L- and H-mode plasmas, as well as during transient events such as L–H transitions and pellet injections. Control errors in plasma shape and radial position remained within 1.5–2.0 cm and 1 cm, respectively. A notable discrepancy was observed in the vertical X-point position, with errors of up to approximately 4 cm, attributed to the current density distribution mismatches between simulations and experiments.