Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sample acquisition”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

CHESS 2025: Orthorectified airborne RGB imagery from NEON AOP surveys

This dataset provides Level 1 (L1) and Level 3 (L3) orthorectified Red-Green-Blue (RGB) imagery collected for the 2025 Colorado Headwaters Ecological Spectroscopy Study (CHESS). This high-resolution imagery is a photographic record of red, green, and blue visible light from sunlight reflected off of the Earth’s surface. The data comprise full-color images of the ground surface and are primarily intended to provide context to imaging spectroscopy and light detection and ranging (LiDAR) data. The data were acquired over three study domains in the Upper Gunnison river basin: the upper East River watershed (CRBU); Almont Triangle and Taylor Canyon (ALMO); and Upper Taylor River watershed (UPTA) between 2025-06-13 and 2025-07-15. RGB images were acquired using the PhaseOne IXM-RS150F high-resolution digital camera onboard the National Ecological Observatory Network (NEON) Airborne Observation Platform (AOP). The package data include both an L1 product comprising one camera frame per file and an L3 mosaic aligned to the Universal Transverse Mercator (UTM) Zone 13N grid and the World Geodetic System (WGS) 84 projection. Both products are provided in geotif (.tif) format at 0.1 m ground resolution. The bulk of the imagery was collected during the main CHESS field campaign from June 13 to July 15, 2025. Additional images of a portion of the Upper Taylor (UPTA) domain were collected on September 18, 2025, to fill gaps in imagery identified after the main campaign was complete. RGB camera imagery is not radiometrically calibrated, and therefore pixel values should not be exploited for scientific analysis. Pixel values have undergone a manual adjustment to enhance feature identification. The imagery is rigorously geolocated which does allow for reliable geometric information to be retrieved. To generate the orthorectified imagery, the NEON AOP camera captured visible spectrum in red, green, and blue bands. The raw images were then processed using NEON’s camera orthorectification workflow. A boresight calibration flight was made to build a complete camera, distortion, and alignment model. Color balance/white balance and exposure correction were applied to the raw RGB images. The corrected images were orthorectified by ray-tracing image pixels to a lidar-derived digital surface model (DSM) mesh using the refined camera model, outputting orthorectified raster pixels on a regular grid. Flightline-level data were mosaicked by selecting per-pixel contributions from overlapping orthorectified images using line-of-sight (LOS) zenith angle minimization to reduce edge distortions. CHESS Project Description: The Colorado Headwaters Ecological Spectroscopy Study (CHESS) comprised a multi-week airborne remote sensing and field observation campaign in the Upper Gunnison Basin, Colorado, conducted in June and July of 2025. Airborne remote sensing was conducted by the National Ecological Observatory Network Airborne Observation Platform (NEON AOP), concurrent with a field campaign run by the Rocky Mountain Biological Laboratory (RMBL), the Lawrence Berkeley National Laboratory (LBNL) and SLAC National Accelerator Laboratory Watershed Function Science Focus Area (SFA), and NASA-JPL (Jet Propulsion Laboratory) Earth Surface Mineral Dust Source Investigation (EMIT) program. Between June 10 and July 18, 2025, the NEON AOP flight team collected high-resolution aerial imaging spectroscopy and Light Detection and Ranging (LiDAR) data over three domains: the Upper East River (CRBU), Almont Triangle (ALMO), and the Upper Taylor Basin (UPTA). In coordination with the flights, a field campaign acquired ground-truth observations, including observations of vegetation composition, foliar traits, forest demography, and subsurface properties in 18 core sampling areas within the domains. Additional surface water observations were taken at over 380 point locations. All CHESS campaign datasets can be found within the CHESS ESS-DIVE data portal: https://data.ess-dive.lbl.gov/portals/chess. Funding Acknowledgement: Field and remote-sensing data acquisition was performed under a grant from the National Aeronautics and Space Administration (80NSSC24K1005). This work was also supported by the Watershed Function Science Focus Area at Lawrence Berkeley National Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-05CH11231.

2018 NEON and 2025 CHESS Campaigns↗

CHESS 2025: Post-survey report for 2025 NEON AOP Assignable Asset collection of East River and Washington Gulch, Almont and Upper Taylor watersheds at Crested Butte, CO

This report contains details of the National Ecological Observatory Network (NEON) Airborne Observation Platform (AOP) Research Support Services (RSS) Assignable Asset (AA) flights of the East River, Almont and Upper Taylor watersheds near Crested Butte, CO, June–July 2025. The Rocky Mountain Biological Laboratory (RMBL) contracted the NEON AOP AA flights to observe watersheds of interest near Crested Butte with remotely sensed data including high resolution LiDAR, imaging spectroscopy, and high-resolution camera imagery. The report includes a summary of the acquired flight lines over the planned survey areas, results of calibration flights, and results of the acquired data. The report details how the AOP has met the contracted delivery requirements in terms of the data delivered, quality of the data, and describes issues that resulted in data degradation or data loss. CHESS Project Description: The Colorado Headwaters Ecological Spectroscopy Study (CHESS) comprised a multi-week airborne remote sensing and field observation campaign in the Upper Gunnison Basin, Colorado, conducted in June and July of 2025. Airborne remote sensing was conducted by the National Ecological Observatory Network Airborne Observation Platform (NEON AOP), concurrent with a field campaign run by the Rocky Mountain Biological Laboratory (RMBL), the Lawrence Berkeley National Laboratory (LBNL) and SLAC National Accelerator Laboratory Watershed Function Science Focus Area (SFA), and NASA-JPL (Jet Propulsion Laboratory) Earth Surface Mineral Dust Source Investigation (EMIT) program. Between June 10 and July 18, 2025, the NEON AOP flight team collected high-resolution aerial imaging spectroscopy and Light Detection and Ranging (LiDAR) data over three domains: the Upper East River (CRBU), Almont Triangle (ALMO), and the Upper Taylor Basin (UPTA). In coordination with the flights, a field campaign acquired ground-truth observations, including observations of vegetation composition, foliar traits, forest demography, and subsurface properties in 18 core sampling areas within the domains. Additional surface water observations were taken at over 380 point locations. All CHESS campaign datasets can be found within the CHESS ESS-DIVE data portal: https://data.ess-dive.lbl.gov/portals/chess. Funding Acknowledgement: Field and remote-sensing data acquisition was performed under a grant from the National Aeronautics and Space Administration (80NSSC24K1005). This work was also supported by the Watershed Function Science Focus Area at Lawrence Berkeley National Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-05CH11231.

2018 NEON and 2025 CHESS Campaigns↗

Evaluation of Potential DAS Array Geometries for the Source Physics Experiment, Phase III

Distributed Acoustic Sensing (DAS) is a rapidly developing technology that can record acoustic wavefields at high sampling rates and with dense spatial spacing difficult to achieve with seismometers. However, the geophysical community has not fully explored DAS survey parameters to characterize the ideal array design. A better quantitative understanding of DAS array behavior prior to SPE Phase III acquisition can help improve the quality of the data recorded by guiding the DAS array design. Here we use array response functions as well as beamforming and backprojection results from forward modelling calculations to assess the performance of varying DAS array geometries to record regional and local sources. A seven-sided polygon DAS array demonstrated improved capabilities for recording regional sources over segmented linear arrays, with potential improvements in recording and locating local sources. These results help reveal DAS array performance as a function of geometry.

58 GEOSCIENCES↗

Introduction to Evolve Central Appalachia

The Evolve-CAPP project is developing and implementing strategies to enable the Central Appalachian basin to realize its full economic potential for producing high-value, non-fuel, carbon-ore (CO) products, rare earth elements (REE), and critical minerals (CM). The Basinal Assessment of CORE-CM Resources is a state-of-the-art geological model and comprehensive database that will be used to identify, locate, and quantify in-situ resources in the basin. Restrictive aspects of resource recovery, such as ownership and legal restrictions, are being considered in estimating recoverable resources. A gap analysis of missing or unavailable data that could not be fully integrated in the initial assessment due to budget, access, or other constraints during the assessment effort is planned. A characterization and data acquisition plan to fully characterize the basin’s CORE-CM potential will address gaps in data. The plan will be developed with input from project team members and relevant stakeholders, including land and mineral holding companies and coal operators, who maintain sampling programs as part of their normal operations.

Bishop, Richard↗

Endophyte-Promoted Phosphorus Solubilization in Populus

Phosphorus is an important plant nutrient, but in soils the majority of phosphorus, present in the form of a phosphate, forms metal complexes in soil making it relatively unavailable to plants. Therefore, inorganic phosphate solubilization is an important process of plant growth promotion by plant associated bacteria and fungi. Non nodulating plant species have been shown to thrive in low-nutrient environments, in some instances by relying on plant associated microorganisms called endophytes. These microorganisms live within the plant and help supply nutrients for the plant. Despite their potential enormous environmental importance, there are a limited number of studies looking at the direct molecular impact of phosphate solubilizing endophytic bacteria on the host plant. In this work, we studied the impact of two endophyte strains of wild poplar (Populus trichocarpa) that solubilize phosphate. Using a combination of x-ray imaging, spectroscopy methods, and proteomics we report direct evidence of endophyte-promoted phosphorus uptake in poplar. We found that the solubilized phosphate inside the plant may react and become insoluble again suggesting that the phosphate could be re-released within the plant by endophytes. Using synchrotron x-ray fluorescence spectromicroscopy combined with x-ray absorption near-edge structure, we visualized the nutrient phosphorus inside poplar roots inoculated by the selected endophytes and found the phosphorus in both forms of organic and inorganic phosphates inside the root. Tomography-based root imaging revealed a markedly different root biomass and root architecture for poplar samples inoculated with the phosphate solubilizing bacteria strains. Proteomics characterization on poplar roots coupled with protein network analysis revealed novel proteins and metabolic pathways with possible involvement in endophyte enriched phosphorus uptake. These findings suggest an important role of endophytes for phosphorus acquisition and provide a deeper understanding of the critical symbiotic associations between poplar and the endophytic bacteria.

36 MATERIALS SCIENCE↗

High resolution and fast scanning squid based non-destructive inspection system of niobium sheets for SRF cavities

Applications in high energy physics accelerators and other fields require the use of thousands of superconducting RF (SRF) cavities that are made of high purity Nb material and the purity of niobium is critical for these cavities to reach the highest accelerating fields. Tantalum is the most prolific of metal inclusions, which can cause thermal breakdown and prevent the cavities from reaching their theoretical performance limits of 45-50 MV/m, and DOE Labs are searching for a technology that could detect small impurities in superconducting Nb sheets reaching the highest possible accelerating fields. The proposed innovative SQUID-based Nondestructive system can scan Niobium sheets used in the manufacturing of SRF cavities with both high speed and high resolution. A highly sensitive SQUID system with a gradiometer probe, non-magnetic dewar, data acquisition system, and a scanning system will be developed for fast detection of impurities in planar Nb sheets. In phase I, we will modify our existing SQUID-based eddy current system to detect 100 micron size Ta defects and a great effort will focus on achieving fast scanning of a large number of niobium sheets in a shorter time and with reasonable resolution. An older system operated by moving the sample 1 mm, stopping and waiting for 1-2 seconds, then activating a measurement by the SQUID after the short settle time is modified. A preliminary designed and implemented a SQUID scanning system that is fast and is capable of scanning a 30 cm x 30 cm Nb sheet in 15 minutes by continuously moving the table at speeds up to 10 mm/s while activating the SQUID at 1mm interval is modified and reached the Phase I goal of 100mm resolution. We have successfully demonstrated the feasibility that a fast speed SQUID scanner without sacrificing the resolution of detection can be done, and a data acquisition and analysis system is also preliminary developed. The SQUID based scanner will help reach the highest accelerating field in SRF cavities that will provide a considerable cost reduction for new accelerators and for upgrades of existing accelerators. This will be realized either by reducing the length required for the SRF cavities or by the installation of higher gradient cavities for energy upgrades in the same space. The SQUID based scanner will also be used for the detection of defects on the surface, inside the bulk or at the back side of metallic sheets in other industries.

43 PARTICLE ACCELERATORS↗

Glacier ice archives nearly 15,000-year-old microbes and phages

Background Glacier ice archives information, including microbiology, that helps reveal paleoclimate histories and predict future climate change. Though glacier-ice microbes are studied using culture or amplicon approaches, more challenging metagenomic approaches, which provide access to functional, genome-resolved information and viruses, are under-utilized, partly due to low biomass and potential contamination. Results We expand existing clean sampling procedures using controlled artificial ice-core experiments and adapted previously established low-biomass metagenomic approaches to study glacier-ice viruses. Controlled sampling experiments drastically reduced mock contaminants including bacteria, viruses, and free DNA to background levels. Amplicon sequencing from eight depths of two Tibetan Plateau ice cores revealed common glacier-ice lineages including Janthinobacterium, Polaromonas, Herminiimonas, Flavobacterium, Sphingomonas, and Methylobacterium as the dominant genera, while microbial communities were significantly different between two ice cores, associating with different climate conditions during deposition. Separately, ~355- and ~14,400-year-old ice were subject to viral enrichment and low-input quantitative sequencing, yielding genomic sequences for 33 vOTUs. These were virtually all unique to this study, representing 28 novel genera and not a single species shared with 225 environmentally diverse viromes. Further, 42.4% of the vOTUs were identifiable temperate, which is significantly higher than that in gut, soil, and marine viromes, and indicates that temperate phages are possibly favored in glacier-ice environments before being frozen. In silico host predictions linked 18 vOTUs to co-occurring abundant bacteria (Methylobacterium, Sphingomonas, and Janthinobacterium), indicating that these phages infected ice-abundant bacterial groups before being archived. Functional genome annotation revealed four virus-encoded auxiliary metabolic genes, particularly two motility genes suggest viruses potentially facilitate nutrient acquisition for their hosts. Finally, given their possible importance to methane cycling in ice, we focused on Methylobacterium viruses by contextualizing our ice-observed viruses against 123 viromes and prophages extracted from 131 Methylobacterium genomes, revealing that the archived viruses might originate from soil or plants. Conclusions Together, these efforts further microbial and viral sampling procedures for glacier ice and provide a first window into viral communities and functions in ancient glacier environments. Such methods and datasets can potentially enable researchers to contextualize new discoveries and begin to incorporate glacier-ice microbes and their viruses relative to past and present climate change in geographically diverse regions globally.

59 BASIC BIOLOGICAL SCIENCES↗

Adversarial uncertainty quantification in physics-informed neural networks

Here, we introduce a deep learning framework for quantifying and propagating uncertainty in systems governed by non-linear differential equations using physics-informed neural networks. Specifically, we employ latent variable models to construct probabilistic representations for the system states, and put forth an adversarial inference procedure for training them on data, while constraining their predictions to satisfy given physical laws expressed by partial differential equations. Such physics-informed constraints provide a regularization mechanism for effectively training deep generative models as surrogates of physical systems in which the cost of data acquisition is high, and training data-sets are typically small. This provides a flexible framework for characterizing uncertainty in the outputs of physical systems due to randomness in their inputs or noise in their observations that entirely bypasses the need for repeatedly sampling expensive experiments or numerical simulators. Moreover, we demonstrate the effectiveness of our approach through a series of examples involving uncertainty propagation in non-linear conservation laws, and the discovery of constitutive laws for flow through porous media directly from noisy data.

97 MATHEMATICS AND COMPUTING↗

Coherent diffraction microscopy at SPring-8: instrumentation, data acquisition and data analysis

Since the first demonstration of coherent diffraction microscopy in 1999, this lensless imaging technique has been experimentally refined by continued developments. Here, instrumentation and experimental procedures for measuring oversampled diffraction patterns from non-crystalline specimens using an undulator beamline (BL29XUL) at SPring-8 are presented. In addition, detailed post-experimental data analysis is provided that yields high-quality image reconstructions. As the acquisition of high-quality diffraction patterns is at least as important as the phase-retrieval procedure to guarantee successful image reconstructions, this work will be of interest for those who want to apply this imaging technique to materials science and biological samples.

oversampling↗

Temperature dependence of secondary electron emission: A new route to nanoscale temperature measurement using scanning electron microscopy

Scanning electron microscopy (SEM) is ubiquitous for imaging but is not generally regarded as a tool for thermal measurements. Here, the temperature dependence of secondary electron (SE) emission from a sample's surface is investigated. Spatially uniform SEM images and the net charge flowing through a sample were recorded at different temperatures to quantify the temperature dependence of SE emission and electron absorption. The measurements also demonstrated charge conservation during thermal cycling by placing the sample inside a Faraday cup to capture the emitted SEs and back-scattered electrons from the sample. The temperature dependence of SE emission was measured for four semiconducting materials (Si, GaP, InP, and GaAs) with response coefficients found to be of magnitudes ~100-1000 ppm/K. The detection limits for temperature changes were no more than ±8 °C for 60 s acquisition time.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evaluation of an event-driven 3FI ASIC for spectroscopic X-ray detection with synchrotron radiation

The novel design and evaluation on the NSLS-II beamline of the 3FI application-specific integrated circuit (ASIC) bump-bonded to a simple, planar, 2D segmented silicon sensor are presented. The ASIC was developed for full-field fluorescence spectral X-ray imaging (3FI). It is a small-scale prototype that features a square array of 32 × 32 pixels, and the size of the pixels is 100 µm × 100 µm. The ASIC was implemented in a 65 nm CMOS integrated circuit fabrication process. Each pixel incorporates a charge-sensitive amplifier, a shaping filter, a discriminator, a peak detector and a sample-and-hold circuit, allowing detection of events and storage of signal amplitudes. The system operates in a frameless event-driven readout mode, outputting analog values for threshold-triggered events, allowing high-speed multi-element X-ray fluorescence data acquisition. The 3FI ASIC achieves per-channel spectrometric performance at a power consumption of only 200 µW per pixel, with nearly all dissipation confined to the analog front-end. An energy resolution is measured at the level of 308 eV full width at half-maximum (FWHM) at 8.04 keV (Cu Kα), and 138 eV FWHM at 3.69 keV (Ca Kα). This per-pixel capability makes the prototype suitable for in situ trace element microanalysis in biological and environmental studies. Moreover, the frameless architecture of the detector is designed to address limitations of conventional X-ray fluorescence microscopy, which typically requires mechanical scanning, by enabling continuous high-throughput data acquisition in future full-field implementations.

47 OTHER INSTRUMENTATION↗

Connect the Dots: In Situ 4-D Seismic Monitoring of CO 2 Storage With Spatio-Temporal CNNs

4-D seismic imaging has been widely used in CO 2 sequestration projects to monitor the fluid flow in the volumetric subsurface region that is not sampled by wells. Ideally, real-time monitoring and near-future forecasting would provide site operators with great insights to understand the dynamics of the subsurface reservoir and assess any potential risks. However, due to obstacles such as high deployment cost, availability of acquisition equipment, exclusion zones around surface structures, only very sparse seismic imaging data can be obtained during monitoring. That leads to an unavoidable and growing knowledge gap over time. The operator needs to understand the fluid flow throughout the project lifetime and the seismic data are only available at a limited number of times. This is insufficient for understanding reservoir behavior. To overcome those challenges, we have developed spatio-temporal neural-network-based models that can produce high-fidelity interpolated or extrapolated images effectively and efficiently. Specifically, our models are built on an autoencoder, and incorporate the long short-term memory (LSTM) structure with a new loss function regularized by optical flow. We validate the performance of our models using real 4-D post-stack seismic imaging data acquired at the Sleipner CO 2 sequestration field. We employ two different strategies in evaluating our models. Numerically, we compare our models with different baseline approaches using classic pixel-based metrics. We also conduct a blind survey and collect a total of 20 responses from domain experts to evaluate the quality of data generated by our models. Finally, via both numerical and expert evaluation, we conclude that our models can produce high-quality 2-D/3-D seismic imaging data at a reasonable cost, offering the possibility of real-time monitoring or even near-future forecasting of the CO 2 storage reservoir.

4-D seismic imaging↗

Syracuse University Test Report On Uptake Factor Resulting From A Dropped Storage Container

Under certain circumstances, powder from an accidently dropped container can become airborne and inhaled by people nearby such as those who are moving the containers. The inhaled fine particles can deposit on respiratory tracts and lungs, causing asthma, lung cancer, and other acute respiratory illnesses and chronic symptoms. The objective of this study was to develop a standard procedure to measure the airborne concentrations of different size particles within the vicinity of a dropped container where a significant portion of the contained powder is ejected. Tungsten oxide (WO{sub 3}) was selected in this study to represent relatively heavy powders (7.16 g/cm3 specific gravity for WO{sub 3}). A typical can with the outer dimensions of 4.25” diameter and 4.875” tall was used as the container. The powder was dropped in two different configurations: 1) contained within a can covered by a lid that has a 0.25” diameter hole, and 2) contained within a can without a lid. The packing volume of the powder was 51.4 in{sup 3} (842.7 cm{sup 3}) and the target mass was 1936 g. The tests were carried out in a full-scale stainless steel environmental chamber with an interior volume of 852 ft{sup 3} (24.1 m{sup 3}). The chamber system includes an internal recirculation loop with a rectangular air diffuser and 10 variable frequency drive fans to provide a typical room air recirculation flow pattern. Two air filters were installed in the chamber air supply duct and return duct to achieve the required low background particle concentration. The initial chamber air conditions were set at 70°F (± 5°F) and 50% (± 10%) RH. A supporting frame and releasing device were designed and built to trigger consistently the dropping of the can at a height of 8 feet from the bottom of the can to the impacting surface. The particle sampling inlet was placed 5 ft above the floor and 6 inches laterally away from the can’s falling path. Concentrations of particles between 0.5 μm and 20 μm were recorded in units of mass and number of particles per unit volume. The data acquisition rate was once every 2 seconds during the first 2 hours and every 20 seconds thereafter. A test procedure was developed and a total of nine drop tests were performed. In most cases (seven tests), the can tipped over after dropping. The can in Test 1 stayed upright. The can in Test 7 showed a special behavior: after the rebound, it turned upside down and stayed upright. Major findings are summarized below: The amount of spilled powder varied from 0.12 g to 252.35 g and the non-recovered powder varied from 0.11 g to 1.18 g. The corresponding percentage of the spilled powder ranged from 0.01% to 13%;The peak value of particle number concentration after the dropping of the can occurred at approximately 0.9 μm particle size per measured data of individual channels. The peak value of particle mass concentration occurred in the range of 4.3 - 10 μm particle size per grouped data calculated from the measured data with the exception of Test 4 where a different batch powder with unexpectedly different bulk density and particle size distribution; After the dropping of the can, the total airborne mass concentrations ranged from 0.03 to 0.35 mg/m{sup 3}, while the total airborne number concentrations ranged from 2 to 125 #/cm{sup 3} except for Test 4. The number concentration in Test 4 was 1 or 2 orders of magnitude less than those of other tests because the powder was from a different batch. However, its mass concentration was comparable to that in Test 7 because relatively more big airborne particles were detected in Test 4. In general, tests with lid (Test 5, 6, 7 and 8) had smaller concentrations than tests without lid (Test 0, 1, 2, and 3). The influence of lid was not as prominent as the powder (Test 4). However, this needs more tests for verification; The ratio of airborne mass to non-recovered mass ranged from 0.1% to 2%. This means that it is challenging to use this method to check the mass balance, while the uptake factor and associated inhalation exposure can be readily assesse; The calculated cumulative uptake mass within first 10 minutes after the dropping of the can for each test was within the range of 0.002 mg to 0.035 mg. Assuming a breathing rate of 1.2 m{sup 3}/h, the uptake factor during the first 10 minutes was calculated to be between 10{sup -9} and 2×10{sup -8} in reference to the amount loaded; or between 10{sup -8} and 6×10{sup -5} in reference to the amount spilled. The experimental results of this study will be useful for standardizing the test method and provide data for estimating the exposure and associated risk to building occupants in the case of an accidental dropping of heavy powder containers.

42 ENGINEERING↗

Syracuse Univesity Test Report On Uptake Factor Resulting From A Dropped Storage Container - Phase II

Under certain circumstances, powder from an accidently dropped container can become airborne and inhaled by people nearby such as those who are moving the containers. The inhaled fine particles can deposit on respiratory tracts and lungs, causing asthma, lung cancer, and other acute respiratory illnesses and chronic symptoms. The objective of this study was to develop a standard procedure to measure the airborne concentrations of different size particles within the vicinity of a dropped container where a significant portion of the contained powder is ejected. Tungsten oxide (WO 3 ) was selected in this study to represent relatively heavy powders (7.16 g/cm 3 specific gravity for WO 3 ). A typical can with the outer dimensions of 4.25” diameter and 4.875” tall was used as the container. The powder was dropped in two different configurations: 1) contained within a can covered by a lid that has a 0.25” diameter hole, and 2) contained within a can without a lid. The packing volume of the powder was 51.4 in 3 (842.7 cm 3 ) and the target mass was 1936 g. The tests were carried out in a full-scale stainless steel environmental chamber with an interior volume of 852 ft 3 (24.1 m3). The chamber system includes an internal recirculation loop with a rectangular air diffuser and 10 variable frequency drive fans to provide a typical room air recirculation flow pattern. Two air filters were installed in the chamber air supply duct and return duct to achieve the required low background particle concentration. The initial chamber air conditions were set at 70°F (± 5°F) and 50% (± 10%) RH. A supporting frame and releasing device were designed and built to trigger consistently the dropping of the can. The particle sampling inlet was placed 5 ft above the floor and 6 inches laterally away from the can’s falling path. Concentrations of particles between 0.5 μm and 20 μm were recorded in units of mass and number of particles per unit volume. The data acquisition rate was once every 2 seconds during the first 2 hours. A test procedure was developed and verified. A total of thirty two drop tests were performed, eight in Phase I and twenty four in Phase II, covering variations in dropping height (8 ft or 4 ft from the floor), room air movement (0.25-0.30 m/s or 0.10-0.15 m/s near the ceiling), landing scenario (on a flat plate or a block), and lid condition (¼” lid hole or no lid). There were ten tests with flat plate and ¼” lid hole, ten tests with flat plate no lid and twelve tests with block no lid.

42 ENGINEERING↗

Heteronuclear single quantum coherence (HSQC) NMR spectra of lignin isolated from switchgrass residues after fermentation with milling

Here we present a curated dataset of two-dimensional heteronuclear single quantum coherence (HSQC) nuclear magnetic resonance (NMR) spectra of lignin isolated from a herbaceous energy crop (Panicum virgatum L.). The lowland variant “Timber” switchgrass from Ernst seeds was used. The switchgrass was knife milled and passed through a 2 mm sieve prior to consolidated bioprocessing (CBP) process. Switchgrass was suspended in Milli-Q water and autoclaved for 90 min on liquid cycles. The residues after autoclaving were then subjected to CBP using coculture of Clostridium thermocellum (C. thermocellum DSM 1313 (LL1004)) and Thermoanaerobacterium thermosaccarolyticum ( T. thermosaccharolyticum HG-8 ATCC 31960 (LL1244)). Once-fermented and twice-fermented (FF) switchgrass were subjected to ball and disc milling in bioreactors at 55 °C and 60, 48 grams/L solids loadings for primary and secondary fermentation respectively. When fermentations were completed, the residual solids were rinsed with milli-Q water. Lignin was isolated from the pretreated residues after ball-milling in a porcelain jar with ceramic balls via Retsch PM 200 at 600 rpm for 2 h followed by enzymatic hydrolysis in acetate buffer (pH 4.8, 50 °C) for 48 h. The dry lignin samples were dissolved in deuterated dimethyl sulfoxide (d6) and characterized using 13C–1H HSQC in a Bruker Avance III HD 500-MHz NMR spectrometer. A standard Bruker pulse sequence (hsqcetgpsisp.2) was used on a Prodigy platform cryoprobe. The spectra were acquired with the following acquisition conditions: 230 ppm spectral width in F1 (13C) dimension with 256 data points and 12 ppm spectral width in F2 (1H) dimension with 2048 data points, a 90° pulse, with a C–H coupling constant of 145 Hz, a 1.0 s pulse delay, and 64 scans. Spectra were processed using the Bruker TopSpin 3.6 software.

Lignin, HSQC, Switchgrass, CBP , Ball mill, Disc m↗

High-Speed Tandem Mass Spectrometric in Situ Imaging by Nanospray Desorption Electrospray Ionization Mass Spectrometry

Nanospray desorption electrospray ionization (nano-DESI) combined with tandem mass spectrometry (MS/MS), high-resolution mass analysis (m/m=17,500 at m/z 200), and rapid spectral acquisition enabled simultaneous imaging and identification of more than 300 molecules from 92 selected m/z windows (± 1 Da) with a spatial resolution of better than 150 um. Uterine sections of implantation sites on day 6 of pregnancy were analyzed in the ambient environment without any sample pre-treatment. MS/MS imaging was performed by scanning the sample under the nano-DESI probe at 10 um/s while acquiring higher-energy collision-induced dissociation (HCD) spectra for a targeted inclusion list of 92 m/z values at a rate of ~6.3 spectra/s. Molecular ions and their corresponding fragments, separated using high-resolution mass analysis, were assigned based on accurate mass measurement. Using this approach, we were able to identify and image both abundant and low-abundance isobaric species within each m/z window. MS/MS analysis enabled efficient separation and identification of isobaric sodium and potassium adducts of phospholipids. Furthermore, we identified several metabolites associated with early pregnancy and obtained the first 2D images of these molecules.

Environmental Molecular Sciences Laboratory↗

Towards Diverse and Representative Global Pretraining Datasets for Remote Sensing Foundation Models

The design of a pretraining dataset is emerging as a critical component for the generality of foundation models. In the remote sensing realm, large volumes of imagery and benchmark datasets exist that can be leveraged to pretrain foundation models, however using this imagery in absence of a well-crafted sampling strategy is inefficient and has the potential to create biased and less generalizable models. Here, we provide a discussion and vision for the curation and assessment of pretraining datasets for remote sensing geospatial foundation models. We highlight the importance of geographic, temporal, and image acquisition diversity and review possible strategies to enable such diversity at global scale. In addition to these characteristics, support for various spatial-temporal pretext tasks within the dataset is also critical. Ultimately, our primary objective is to place emphasis on and draw attention to the data curation stage of the foundation model development pipeline. By doing so, we think it is possible to reduce biases of geospatial foundation models, as well as enable broader generalization to downstream remote sensing tasks and applications.

Arndt, Jacob↗

Superficial dosimetry imaging based on Čerenkov emission for external beam radiotherapy with megavoltage x-ray beam

Purpose: Čerenkov radiation emission occurs in all tissue, when charged particles (either primary or secondary) travel at velocity above the threshold for the Čerenkov effect (about 220 KeV in tissue for electrons). This study presents the first examination of optical Čerenkov emission as a surrogate for the absorbed superficial dose for MV x-ray beams.Methods: In this study, Monte Carlo simulations of flat and curved surfaces were studied to analyze the energy spectra of charged particles produced in different regions near the surfaces when irradiated by MV x-ray beams. Čerenkov emission intensity and radiation dose were directly simulated in voxelized flat and cylindrical phantoms. The sampling region of superficial dosimetry based on Čerenkov radiation was simulated in layered skin models. Angular distributions of optical emission from the surfaces were investigated. Tissue mimicking phantoms with flat and curved surfaces were imaged with a time domain gating system. The beam field sizes (50 × 50–200 × 200 mm{sup 2}), incident angles (0°–70°) and imaging regions were all varied.Results: The entrance or exit region of the tissue has nearly homogeneous energy spectra across the beam, such that their Čerenkov emission is proportional to dose. Directly simulated local intensity of Čerenkov and radiation dose in voxelized flat and cylindrical phantoms further validate that this signal is proportional to radiation dose with absolute average discrepancy within 2%, and the largest within 5% typically at the beam edges. The effective sampling depth could be tuned from near 0 up to 6 mm by spectral filtering. The angular profiles near the theoretical Lambertian emission distribution for a perfect diffusive medium, suggesting that angular correction of Čerenkov images may not be required even for curved surface. The acquisition speed and signal to noise ratio of the time domain gating system were investigated for different acquisition procedures, and the results show there is good potential for real-time superficial dose monitoring. Dose imaging under normal ambient room lighting was validated, using gated detection and a breast phantom.Conclusions: This study indicates that Čerenkov emission imaging might provide a valuable way to superficial dosimetry imaging in real time for external beam radiotherapy with megavoltage x-ray beams.

61 RADIATION PROTECTION AND DOSIMETRY↗