At least 649 records · Page 36

Neutron resonance spin-echo upgrade at the three-axis spectrometer FLEXX

We describe the upgrade of the neutron resonance spin-echo setup at the cold neutron triple-axis spectrometer FLEXX at the BER II neutron source at the Helmholtz-Zentrum Berlin. The parameters of redesigned key components are discussed, including the radio frequency (RF) spin-flip coils, the magnetic shield, and the zero field coupling coils. The RF-flippers with larger beam windows allow for an improved neutron flux transfer from the source to the sample and further to the analyzer. The larger beam cross sections permit higher coil inclination angles and enable measurements on dispersive excitations with a larger slope of the dispersion. Due to the compact design of the spin-echo units in combination with the increased coil tilt angles, the accessible momentum-range in the Larmor diffraction mode is substantially enlarged. In combination with the redesigned components of the FLEXX spectrometer, including the guide, the S-bender polarizer, the double focusing monochromator, and a Heusler crystal analyzer, the count rate increased by a factor of 15.5, and the neutron beam polarization is enhanced. The improved performance extends the range of feasible experiments, both for inelastic scattering on excitation lifetimes in single crystals, and for high-resolution Larmor diffraction. The experimental characterization of the instrument components demonstrates the reliable performance of the new neutron resonance spin-echo option, now available for the scientific community at FLEXX.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PXIE: Project X Injector Experiment

A multi-MW proton facility, Project X, has been proposed and is currently under development at Fermilab. We are planning a program of research and development aimed at integrated systems testing of critical components comprising the front end of the Project X. This program is being undertaken as a key component of the larger Project X R&D program. The successful completion of this program will validate the concept for the Project X front end, thereby minimizing a primary technical risk element within Project X. Integrated systems testing, known as the Project X Injector Experiment (PXIE), will be accomplished with a new test facility under construction at Fermilab and will be completed over the period FY12-16. PXIE will include an H{sup -} ion source, a CW 2.1-MeV RFQ and two superconductive RF (SRF) cryomodules providing up to 25 MeV energy gain at an average beam current of 1 mA (upgradable to 2 mA). Successful systems testing will also demonstrate the viability of novel front end technologies that are expected find applications beyond Project X.

43 PARTICLE ACCELERATORS↗

Design and fabrication of ion traps for low RF power dissipation

Large surface-electrode ion traps with multiple trapping regions and junctions are a natural approach to scaling trapped ion quantum computers, supporting the connectivity and ion counts necessary for complex quantum algorithms. However, a major hurdle in this scaling is on-chip power dissipation from the applied RF voltage, which increases at a rate between linear and cubic relative to trap size, depending on whether the losses are dielectric or Ohmic. Here, we present two versions of a trap with features designed to reduce both types of RF power dissipation. The first variant contains a raised RF electrode that increases the electrode–ground distance to reduce capacitance. Different DC voltage sources are demonstrated on this trap to show that technical noise before the filter remains the dominant source of voltage noise and therefore motional heating. The second variant additionally includes a method for removing dielectric from beneath the RF electrode to further reduce dielectric losses. These traps were demonstrated at room temperature with 40 Ca + ions. In conclusion, the similar heating rates and heating rate axial frequency dependencies between 2.4 and 3.0 MHz illustrate that this dielectric modification is not detrimental to trap performance.

Sterk, J. D. [Sandia National Laboratories (SNL-NM↗

Plasma Flow During RF Discharges in VASIMR

The Variable Specific Impulse Magnetoplasma Rocket (VASIMR) plasma source consists of a helical antenna, driven at frequencies of 4 to 19 MHz with powers up to 1 kW, in a magnetic field up to 3 kG. Helium is the current test gas, and future experiments with hydrogen are planned. Plasma density and temperature profiles were measured by a reciprocating Langmuir probe, and plasma flow profiles were measured with a reciprocating Mach probe. Both probes were located about 0.5 m downstream from the helical antenna. The plasma source operated in capacitive and inductive modes in addition to a helicon mode. During capacitive and inductive modes, densities were low and plasma flow was < 0.5 Cs. When the plasma operated in a helicon mode, the densities measured downstream from the source were higher [10(exp 12) / cubic cm ] and plasma flow along the magnetic field was of the order Mach 1. Details of the measurements will be shown.

Jacobson, V. T.↗

Radiation Safety System for SPIDER Neutral Beam Accelerator

SPIDER (Source for Production of Ion of Deuterium Extracted from RF Plasma only) and MITICA (Megavolt ITER Injector Concept Advanced) are the ITER neutral beam injector (NBI) testing facilities of the PRIMA (Padova Research Injector Megavolt Accelerated) Center. Both injectors accelerate negative deuterium ions with a maximum energy of 1 MeV for MITICA and 100 keV for SPIDER with a maximum beam current of 40 A for both experiments. The SPIDER facility is classified in Italy as a particle accelerator. At present, the design of the radiation safety system for the facility has been completed and the relevant reports have been presented to the Italian regulatory authorities. Before SPIDER can operate, approval must be obtained from the Italian Regulatory Authority Board (IRAB) following a detailed licensing process. In the present work, the main project information and criteria for the SPIDER injector source are reported together with the analysis of hypothetical accidental situations and safety issues considerations. Neutron and photon nuclear analysis is presented, along with special shielding solutions designed to meet Italian regulatory dose limits. The contribution of activated corrosion products (ACP) to external exposure of workers has also been assessed. Nuclear analysis indicates that the photon contribution to worker external exposure is negligible, and the neutron dose can be considered by far the main radiation protection issue. Our results confirm that the injector has no important radiological impact on the population living around the facility.

43 PARTICLE ACCELERATORS↗

Oxygen vacancies in niobium pentoxide as a source of two-level system losses in superconducting niobium

Two-level systems (TLS) have long been a catch-all explanation for RF loss and quantum decoherence in superconducting devices. In our study, the first to directly link TLS losses to a specific physical mechanism, we demonstrate that oxygen vacancies in the naturally formed Nb₂O₅ on oxidized niobium are a major driver of such dissipation. We performed sequential in situ vacuum-baking treatments on niobium superconducting radio-frequency (SRF) cavities and used time-of-flight secondary ion mass spectrometry (TOF-SIMS) to reveal a nonmonotonic evolution in cavity quality factor (Q₀). This behavior correlates with the interplay of Nb₂O₅ vacancy generation and oxide-thickness dissolution. We localize this effect to the oxide itself and present the insignificant role of diffused interstitial oxygen in the underlying Nb by regrowing the oxide via wet oxidation, revealing a mitigation of aggravated TLS losses. We hypothesize that such vacancies in the pentoxide serve as magnetic impurities and are a source of TLS-driven rf loss. Although our measurements center on 3-D SRF cavities, the insights gained here have significant implications for mitigating decoherence in 2-D superconducting qubits.

Bafia, Daniel P. [Fermilab]↗

Simulation of plasma and neutral transport in PISCES-RF using SOLPS-ITER

In this research, the fluid plasma transport code SOLPS-ITER is applied and validated against experimental data from the plasma interaction surface component experimental station (PISCES)-RF linear plasma device to establish a physics basis for plasma and neutral transport in its two magnetic field (B-field) geometry setups-(1)the cusp and (2) non-cusp or linear B-field. The main focus of this study is to understand (1) radial plasma transport (2) heat and particle loads on the upstream dump and downstream target plate, and (3) the physics of plasma-neutral interactions in PISCES-RF. The simulation setup adheres to typical PISCES-RF experimental conditions, with a 2D helicon power deposition profile as an input heating source. SOLPS-ITER simulations reproduce experimental conditions with the Bohm diffusion model for both B-field configurations of the PISCES-RF experiment. Major energy loss channels include neutral radiation and power deposited on the wall and dump plate, with only 1% of the input power reaching the target. The ionization front is well confined near the dump plate due to the heating and puffing regions. Additionally, SOLPS-ITER simulation results are also found to be in very good agreement with the particle-in-cell calculations using the code-PICOS++ which supports the validity of SOLPS in low collisionality regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A High Power CW Input Coupler with Reduced Static and Dynamic Losses

Each niobium cavity employed in superconducting accelerators requires a power coupler that supplies it with up to hundreds of kW’s of CW RF power, which is delivered to the 2K or 4K cold cavity from a Room Temperature (RT) source. Coupler design is a challenging task. It should transmit the minimum possible thermal power flow to the cavity, because a single watt at 2K requires 1 kW of cryogenic system power to remove it. Since the coupler connects the cold cavity to a Room Temperature (RT) power source, it transmits a static thermal load due to its thermal conductivity. Also, the coupler experiences heating by RF fields. This dissipated power partially penetrates to the 2K zone, and is called a dynamic load. From one point of view, the coupler should have low thermal conductivity, in order to decrease the static load. Stainless steel (SS) is usually used for that reason, but it also has low electrical conductivity, which introduces a high dynamic load. Copper plating on the SS is required to improve the electrical conductivity, but it is not reliable and often flakes. One copper flake might cause an electrical discharge and contaminate the surface of the niobium cavity, thus spoiling its Q-factor. In that case, decommissioning of the entire cryomodule is required to restore the cavity Q-factor, which means it is a tremendously expensive procedure. That is why an improved reliability coupler is of very high interest. As a result, the main idea of the proposed project is to completely eliminate the unreliable copper plating by employing solid copper shields to screen the SS pipe from RF fields.

43 PARTICLE ACCELERATORS↗

A neutron diagnostic for high current deuterium beams

A neutron diagnostic for high current deuterium beams is proposed for installation on the spectral shear interferometry for direct electric field reconstruction (SPIDER, Source for Production of Ion of Deuterium Extracted from RF plasma) test beam facility. The proposed detection system is called Close-contact Neutron Emission Surface Mapping (CNESM). The diagnostic aims at providing the map of the neutron emission on the beam dump surface by placing a detector in close contact, right behind the dump. CNESM uses gas electron multiplier detectors equipped with a cathode that also serves as neutron-proton converter foil. The cathode is made of a thin polythene film and an aluminium film; it is designed for detection of neutrons of energy >2.2 MeV with an incidence angle < 45 deg. CNESM was designed on the basis of simulations of the different steps from the deuteron beam interaction with the beam dump to the neutron detection in the nGEM. Neutron scattering was simulated with the MCNPX code. CNESM on SPIDER is a first step towards the application of this diagnostic technique to the MITICA beam test facility, where it will be used to resolve the horizontal profile of the beam intensity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimizing Native Ion Mobility Q-TOF in Helium and Nitrogen for Very Fragile Noncovalent Structures

The amount of internal energy imparted to the ions prior to the ion mobility cell influences the ion structure and thus the collision cross section. Non-covalent complexes with few internal degrees of freedom and/or high charge densities are particularly sensitive to collisional activation. Here, we investigated the effects of virtually all tuning parameters of the Agilent 6560 IM-Q-TOF on the arrival time distributions of ubiquitin{sup 7+} and found conditions in which the native state prevails. We discuss the effects of solvent evaporation conditions in the source, of the entire pre-IM DC voltage gradient, of the funnel RF amplitudes. We also report on ubiquitin{sup 7+} conformations in different solvents, including native supercharging conditions. Collision-induced unfolding (CIU) can be conveniently provoked either behind the source capillary or in the trapping funnel. The softness of the instrumental conditions behind the mobility cell was further optimized with the DNA G-quadruplex [(dG{sub 4}T{sub 4}G{sub 4}){sub 2}·(NH{sub 4}{sup +}){sub 3}-8H]{sup 5−}, for which ion activation results in ammonia loss. To reduce the ion internal energy and obtain the intact 3-NH{sub 4}{sup +} complex, we reduce the post-IM voltage gradient, but this results in a lower IM resolving power due to increased diffusion behind the drift tube. The article describes the various trade-offs between ion activation, ion transmission, and ion mobility performance for native MS of very fragile structures. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

One-dimensional hybrid simulation of the dc/RF combined driven capacitively coupled CF{sub 4} plasmas

We developed a one-dimensional hybrid model to simulate the dc/RF combined driven capacitively coupled plasma for CF{sub 4} discharges. The numerical results show the influence of the dc source on the plasma density distribution, ion energy distributions (IEDs), and ion angle distributions (IADs) on both RF and dc electrodes. The increase of dc voltage impels more ions with high energy to the electrode applied to the dc source, which makes the IEDs at the dc electrode shift toward higher energy and the peaks in IADs shift toward the small angle region. At the same time, it also decreases ion-energy at the RF electrode and enlarges the ion-angles which strike the RF electrode.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Compact, energy efficient superconducting asymmetric ERL for ultra-high fluxes of X-ray and THz

To make the light sources compact and energy efficient, an energy recovery Superconducting RF LINAC can be used. We suggest a dual-axis, asymmetric cavity instead of conventional single axis, symmetric cavity configurations to generate average electron beam currents above 1 A, while still avoiding development of the beam breakup instability (BBU). The use of an asymmetric cavity allows one to increase the start current of HOMs participating in BBU instability development, as well as to break the positive feedback, resulting in the capability of a high average current electron beam to be driven without loss through the system. In this work, the results of experimental studies of an asymmetric cavity are presented and compared with theoretical predictions. The following steps toward design of a full-scale superconducting cavity are also discussed.

43 PARTICLE ACCELERATORS↗

Temperature Compensated Sapphire Resonator for Ultrastable Oscillator Operating at Temperatures Near 77 Deg Kelvin

A sapphire resonator for an ultrastable oscillator capable of substantial performance improvements over the best available crystal quartz oscillators in a compact cryogenic package is based on a compensation mechanism enabled by the difference between copper and sapphire thermal expansion coefficients for so tuning the resonator as to cancel the temperature variation of the sapphire's dielectric constant. The sapphire resonator consists of a sapphire ring separated into two parts with webs on the outer end of each to form two re-entrant parts which are separated by a copper post. The re-entrant parts are bonded to the post by indium solder for good thermal conductivity between parts of that subassembly which is supported on the base plate of a closed copper cylinder (rf shielding casing) by a thin stainless steel cylinder. A unit for temperature control is placed in the stainless steel cylinder and is connected to the subassembly of re-entrant parts and copper post by a layer of indium for good thermal conduction. In normal use, the rf shielding casing is placed in a vacuum tank which is in turn placed in a thermos flask of liquid nitrogen. The temperature regulator is controlled from outside the thermos flask to a temperature in a range of about 40K to 150K, such as 87K for the WGH-811, mode of resonance in response to microwave energy inserted into the rf shielding casing through a port from an outside source.

Dick, G. John↗

Method and apparatus for low-loss signal transmission

The present invention relates to the field of radio-frequency (RF) waveguides. More specifically, the present invention pertains to a method and apparatus that provides ultra-low-loss RF waveguide structures targeted between approximately 300 GHz and approximately 30 THz. The RF waveguide includes a hollow core and a flexible honeycomb, periodic-bandgap structure surrounding the hollow core. The flexible honeycomb, periodic-bandgap structure is formed of a plurality of tubes formed of a dielectric material such as of low-loss quartz, polyethylene, or high-resistivity silicon. Using the RF waveguide, a user may attach a terahertz signal source to the waveguide and pass signals through the waveguide, while a terahertz signal receiver receives the signals.

Siegel, Peter↗

Stabilization of Phase of a Sinusoidal Signal Transmitted Over Optical Fiber

In the process of connecting widely distributed antennas into a coherent array, it is necessary to synchronize the timing of signals at the various locations. This can be accomplished by distributing a common reference signal from a central source, usually over optical fiber. A high-frequency (RF or microwave) tone is a good choice for the reference. One difficulty is that the effective length of the optical fiber changes with temperature and mechanical stress, leading to phase instability in the received tone. This innovation provides a new way to stabilize the phase of the received tone, in spite of variations in the electrical length of the fiber. Stabilization is accomplished by two-way transmission in which part of the received signal is returned to the transmitting end over an identical fiber. The returned signal is detected and used to close an electrical servo loop whose effect is to keep constant the phase of the tone at the receiving end.

DAddario, Larry R.↗

NASA Tech Briefs, June 2007

Topics covered include: High-Accuracy, High-Dynamic-Range Phase-Measurement System; Simple, Compact, Safe Impact Tester; Multi-Antenna Radar Systems for Doppler Rain Measurements; 600-GHz Electronically Tunable Vector Measurement System; Modular Architecture for the Measurement of Space Radiation; VLSI Design of a Turbo Decoder; Architecture of an Autonomous Radio Receiver; Improved On-Chip Measurement of Delay in an FPGA or ASIC; Resource Selection and Ranking; Accident/Mishap Investigation System; Simplified Identification of mRNA or DNA in Whole Cells; Printed Multi-Turn Loop Antennas for RF Biotelemetry; Making Ternary Quantum Dots From Single-Source Precursors; Improved Single-Source Precursors for Solar-Cell Absorbers; Spray CVD for Making Solar-Cell Absorber Layers; Glass/BNNT Composite for Sealing Solid Oxide Fuel Cells; A Method of Assembling Compact Coherent Fiber-Optic Bundles; Manufacturing Diamond Under Very High Pressure; Ring-Resonator/Sol-Gel Interferometric Immunosensor; Compact Fuel-Cell System Would Consume Neat Methanol; Algorithm Would Enable Robots to Solve Problems Creatively; Hypothetical Scenario Generator for Fault-Tolerant Diagnosis; Smart Data Node in the Sky; Pseudo-Waypoint Guidance for Proximity Spacecraft Maneuvers; Update on Controlling Herds of Cooperative Robots; and Simulation and Testing of Maneuvering of a Planetary Rover.

Source record↗

THE PROJECT-X INJECTOR EXPERIMENT: A NOVEL HIGH PERFORMANCE FRONT-END FOR A FUTURE HIGH POWER PROTON FACILITY AT FERMILAB

A multi-MW proton facility, Project X, has been proposed and is currently under development at Fermilab. We are carrying out a program of research and development aimed at integrated systems testing of critical components comprising the front end of Project X. This program, known as the Project X Injector Experiment (PXIE), is being undertaken as a key component of the larger Project X R&D program. The successful completion of this program will validate the concept for the Project X front end, thereby minimizing a primary technical risk element within Project X. PXIE is currently under construction at Fermilab and will be completed over the period FY12-17. PXIE will include an H* ion source, a CW 2.1-MeV RFQ and two superconductive RF (SRF) cryomodules providing up to 25 MeV energy gain at an average beam current of 1 mA (upgradable to 2 mA). Successful systems testing will also demonstrate the viability of novel front end technologies that are expected find applications beyond Project X.

43 PARTICLE ACCELERATORS↗

Evaluating Light Source Color Rendition using the IES TM-30-15 Method

A system for evaluating the color rendition of light sources was recently published as IES TM-30-15 IES Method for Evaluating Light Source Color Rendition. The system includes a fidelity index (Rf) to quantify similarity to a reference illuminant, a relative-gamut index (Rg) to quantify saturation relative to a reference illuminant, and a color vector icon that visually presents information about color rendition. The calculation employs CAM02-UCS and uses a newly-developed set of reflectance functions, comprising 99 color evaluation samples (CES). The CES were down-selected from 105,000 real object samples and are uniformly distributed in color space (fairly representing different colors) and wavelength space (avoiding artificial increase of color rendition values by selective optimization).

color fidelity↗