Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “refrigerators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Cryogenics program overview

An overview of the cryogenics program of the Goddard Space Flight Center is given in viewgraph form. Goddard's role and the flight programs requiring cryogenics are outlined. Diagrams are given of the Cosmic Background Explorer, the Broad Band X-Ray Telescope, the Hubble Space Telescope, an adiabatic demagnetization refrigerator, a liquid cryogenic cooler for the Shuttle Glow Experiment, a liquid helium dewar, and the X-ray spectrometer on the Advanced X-Ray Astrophysics Facility.

Castles, Stephen H.↗

Large capacity cryopropellant orbital storage facility

A comprehensive study was performed to develop the major features of a large capacity orbital propellant storage facility for the space-based cryogenic orbital transfer vehicle. Projected propellant usage and delivery schedules can be accommodated by two orbital tank sets of 100,000 lb storage capacity, with advanced missions expected to require increased capacity. Information is given on tank pressurization schemes, propellant transfer configurations, pump specifications, the refrigeration system, and flight tests.

Schuster, J. R.↗

A 2.3-GHz maser at Usuda, Japan, for TDRSS-orbiting VLBI experiment

A 2.3 GHz traveling-wave maser/closed-cycle refrigerator (TWM/CCR) that is used in the DSN was installed and successfully operated on the 64 m antenna at Usuda, Japan. The TWM/CCR supported the first very long baseline interferometry (VLBI) experiment to use an orbiting spacecraft as one of the receiving antennas. The experiment required a 15 K receiving system over a 2271 to 2285 MHz bandwidth. The maser installation was made during June 1986, and successful VLBI measurements were made during July and August 1986 and again in January 1987.

Quinn, R. B.↗

Comparison of open and closed multimegawatt space power systems

One of the major questions that is being addressed at present by SDI Multimegawatt Space Power Project is whether or not space weapon power systems must be closed, i.e., whether effluents from the systems are tolerable. If they are not tolerable, the major penalty that must be paid to close space systems is increased mass. Open systems remove waste heat by producing effluents, e.g., hot hydrogen gas. Closed systems require radiators, thermal storage masses, effluent storage, or refrigeration to remove waste heat. The mass penalty incurred by addition of these devices is so severe that the option of closing space power systems should be avoided if at all possible. The mass penalty is even more severe if the weapon system itself must also be closed.

Gallup, D. R.↗

Low temperature storage container for transporting perishables to space station

This invention is directed to the long term storage of frozen and refrigerated food and biological samples by the space shuttle to the space station. A storage container is utilized which has a passive system so that fluid/thermal and electrical interfaces with the logistics module is not required. The container for storage comprises two units, each having an inner storage shell and an outer shell receiving the inner shell and spaced about it. The novelty appears to lie in the integration of thermally efficient cryogenic storage techniques with phase change materials, including the multilayer metalized surface thin plastic film insulation and the vacuum between the shells. Additionally the fiberglass constructed shells having fiberglass honeycomb portions, and the lining of the space between the shells with foil combine to form a storage container which may keep food and biological samples at very low temperatures for very long periods of time utilizing a passive system.

Dean, William G↗

A 2.3-GHz low-noise cryo-FET amplifier

A cryogenic cooled, low-noise Field Effect Transistor (FET) amplifier assembly for use at 2.2 to 2.3 GHz was developed for the DSN to meet the requirements of a Very Long Baseline Interferometry (VLBI) upgrade. An amplifier assembly was developed at JPL that uses a commercial closed-cycle helium refrigerator (CCR) to cool a FET amplifier to an operating temperature of 15 K. A cooled probe waveguide-to-coaxial transition similar to that used in the research and development Ultra-Low-Noise S-band Traveling Wave Maser (TWM) is used to minimize input line losses. Typical performance includes an input flange equivalent noise contribution of 14.5 K, a gain slope of less than 0.05 dB/MHz across a bandwidth of 2.2 to 2.3 GHz, an input VSWR of 1.5:1 at 2.25 GHz, and an insertion gain of 45 + or - 1 dB across the bandwidth of 2.2 to 2.3 GHz. Three 2.3 GHz FET/CCR assemblies were delivered to the DSN in the spring of 1987.

Loreman, J.↗

An 8.4-GHz dual maser front end for Parkes reimplementation

An 8.4 GHz front-end system consisting of a feedhorn, a waveguide feed assembly, dual masers, and downconverters is being reimplemented at Parkes as part of the Parkes-Canberra Telemetry Array for the Voyager Neptune encounter. The front-end system was originally assembled by the European Space Agency on the Parkes antenna for the Giotto project. It was also used on a time-sharing basis by the DSN as part of the Parkes-Canberra Telemetry Array to enhance the data return from Voyager 2 at Uranus. At the conclusion of these projects in 1986, the front-end system was dismantled, packed, and shipped to Europe. Part of the system was then shipped to JPL on loan for reimplementation at Parkes for the Voyager Neptune encounter. The system is being redesigned and refurbished for operation at Parkes. Tasks include new microwave front-end control cabinets, a closed-cycle refrigeration data acquisition system, a new noise-adding radiometer system, a front-end controller assembly, and refurbishment of the dual 8.4 GHz traveling-wave masers (TWMs) and waveguide feed system.

Trowbridge, D. L.↗

Ozone and the stratosphere

It is shown that the stratospheric ozone is effective in absorbing almost all radiation below 300 nm at heights below 300 km. The distribution of global ozone in the troposphere and the lower stratosphere, and the latitudinal variations of the total ozone column over four seasons are considered. The theory of the ozone layer production is discussed together with catalytic reactions for ozone loss and the mechanisms of ozone transport. Special attention is given to the anthropogenic perturbations, such as SST exhaust gases and freon gas from aerosol cans and refrigerators, that may cause an extensive destruction of the stratospheric ozone layer and thus have a profound impact on the world climate and on life.

Shimazaki, Tatsuo↗

Space Station body mounted radiator design

Consideration has been given to utilizing the external area of the Space Station common modules or resource nodes to provide heat rejection. A program was undertaken to define the best body mounted radiator design, to define and build a full size test article and to conduct testing to verify performance. Trade studies were conducted and a preferred design selected. The selected design employed high performance grooved heat pipes of an off-the-shelf design. Twenty panels, each about 1.2 m wide by 5.6 m long are installed on each module rejecting a total of about 12 kW. The radiators are interfaced with the module thermal control loop by use of a refrigerant 21 loop with an on-orbit operable disconnect at each panel. A one-panel test article has been designed and is currently being fabricated. Testing is scheduled to be conducted in June of 1987.

Fleming, M. L.↗

Investigation of surface water behavior during glaze ice accretion

Microvideo observations of glaze ice accretions on 1-in-diameter cylinders in a closed-loop refrigerated wind tunnel were obtained to study factors controlling the behavior of unfrozen surface water during glaze ice accretion. Three zones of surface water behavior were noted, each with a characteristic roughness. The effect of substrate thermal and roughness properties on ice accretions was also studied. The contact angle and hysteresis were found to increase sharply at temperatures just below 0 C, explaining the high resistance to motion of water beads observed on accreting glaze ice surfaces. Based on the results, a simple multizone modification to the current glaze ice accretion model is proposed.

Hansman, R. John, Jr.↗

Space cryogenics components based on the thermomechanical (TM) effect

He II vapor-liquid phase separation (VLPS) is discussed, with emphasis on fluid-related transport phenomena. The VLPS system has been studied for both linear and nonlinear regimes, demonstrating that well-defined convection patterns exist in porous plug phase separators. In the second part, other components based on the thermomechanical effect are discussed in the limit of ideal conditions. Examples considered include the heat pipe transfer of zero net mass flow, liquid transfer pumps based on the fountain effect, mechanocaloric devices for cooling purposes, and He II vortex refrigerators.

Yuan, S. W. K.↗

Control of the interface between (He-3)-rich and (He-4)-rich phases using electric fields

A microgravity dilution refrigerator is considered, and it is shown that electric-field generated forces can be used to control the interface line between (He-3)-rich and (He-3)-poor phases. Fields as high as 13 MV/m are obtained in the present v-shaped geometry which correspond to positioning forces comparable to gravity. Good agreement is found between experimental results on the movements of the interface line and calculations obtained with a two-fluid model.

Israelsson, Ulf E.↗

NBC boil-off calorimeter for measuring thermal conductivity of insulating materials

Modern temperature, pressure and flow sensors along with a high speed digital control system have been incorporated into an existing thermal conductivity apparatus (ASTM C745). The system has also been modified to include the use of liquid helium as the refrigerant, if desired. The apparatus can be used to study thermal conductivity in the temperature range from 4 K to room temperature. Preliminary results on insulating materials indicate that the system update has significantly improved the precision and operational characteristics of the apparatus. Basic principles of operation, sources of system error and the reduction of system error by application of digital control and modern sensors are discussed. Preliminary data are presented.

Dube, W. P.↗

Miniature Centrifugal Compressor

Miniature turbocompressor designed for reliability and long life. Cryogenic system includes compressor, turboexpander, and heat exchanger provides 5 W of refrigeration at 70 K from 150 W input power. Design speed of machine 510,000 rpm. Compressor has gas-lubricated journal bearings and magnetic thrust bearing. When compressor runs no bearing contact and no wear.

Sixsmith, Herbert↗

Survey Of Cooling Techniques

Methods of maintaining electronics at best operating temperatures reviewed. Paper surveys cooling techniques for electronic components and sensors that must be kept at temperatures ranging from thousandths of kelvin to room temperature. Discusses characteristics of various coolers in terms of ground and space applications, cooling capacity, reliability, and temperature range. Also discusses briefly, cooling of conventional electronic circuitry operating few degrees above environmental temperature by natural or forced convection of air or liquid. At greater length, discusses passive and active refrigeration of "cold" electronic circuitry operating below environmental temperature.

Chan, Chung K.↗

Cooling Shelf For Electronic Equipment

Heat-pipe action cools and maintains electronics at nearly constant temperature. System designed to control temperatures of spacecraft shelves or baseplates by combining honeycomb sandwich panel with reservoir of noncondensable gas and processing resulting device as variable-conductance heat pipe. Device provides flat surface for mounting heat-dissipating electronics that is effectively cooled and maintained at nearly constant temperature. Potentially useful in freeze drying, refrigeration, and air conditioning.

Tanzer, Herbert J.↗

Cleaning Animals' Cages With Little Water

Proposed freeze/thaw method for cleaning animals' cages requires little extra weight and consumes little power and water. Cleaning concept developed for maintaining experimental rat cages on extended space missions. Adaptable as well to similar use on Earth. Reduces cleaning time. Makes use of already available facilities such as refrigerator, glove box, and autoclave. Rat waste adheres to steel-wire-mesh floor of cage. Feces removed by loosening action of freezing-and-thawing process, followed by blast of air.

Harman, Benjamin J.↗

A 32-GHz reflected-wave maser amplifier with wide instantaneous bandwidth

An eight stage, 32 GHz reflected wave ruby maser was built. The maser operates in a 3 watt closed cycle refrigerator at 4.5 K and is capable of 21 dB of net gain with an instantaneous bandwidth of 400 MHz. The input noise temperature referred to the room temperature flange is approximately 21 K.

Shell, J.↗