Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “reconstruction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Flexible Learning-Free Segmentation and Reconstruction of Neural Volumes

Imaging is a dominant strategy for data collection in neuroscience, yielding stacks of images that often scale to gigabytes of data for a single experiment. Machine learning algorithms from computer vision can serve as a pair of virtual eyes that tirelessly processes these images, automatically detecting and identifying microstructures. Unlike learning methods, our Flexible Learning-free Reconstruction of Imaged Neural volumes (FLoRIN) pipeline exploits structure-specifc contextual clues and requires no training. This approach generalizes across diferent modalities, including serially-sectioned scanning electron microscopy (sSEM) of genetically labeled and contrast enhanced processes, spectral confocal refectance (SCoRe) microscopy, and high-energy synchrotron X-ray microtomography (μCT) of large tissue volumes. We deploy the FLoRIN pipeline on newly published and novel mouse datasets, demonstrating the high biological fdelity of the pipeline’s reconstructions. FLoRIN reconstructions are of sufcient quality for preliminary biological study, for example examining the distribution and morphology of cells or extracting single axons from functional data. Compared to existing supervised learning methods, FLoRIN is one to two orders of magnitude faster and produces high-quality reconstructions that are tolerant to noise and artifacts, as is shown qualitatively and quantitatively.

47 OTHER INSTRUMENTATION↗

Publisher Correction: Flexible Learning-Free Segmentation and Reconstruction of Neural Volumes

Imaging is a dominant strategy for data collection in neuroscience, yielding stacks of images that often scale to gigabytes of data for a single experiment. Machine learning algorithms from computer vision can serve as a pair of virtual eyes that tirelessly processes these images, automatically detecting and identifying microstructures. Unlike learning methods, our Flexible Learning-free Reconstruction of Imaged Neural volumes (FLoRIN) pipeline exploits structure-specific contextual clues and requires no training. This approach generalizes across different modalities, including serially-sectioned scanning electron microscopy (sSEM) of genetically labeled and contrast enhanced processes, spectral confocal reflectance (SCoRe) microscopy, and high-energy synchrotron X-ray microtomography (μCT) of large tissue volumes. We deploy the FLoRIN pipeline on newly published and novel mouse datasets, demonstrating the high biological fidelity of the pipeline’s reconstructions. FLoRIN reconstructions are of sufficient quality for preliminary biological study, for example examining the distribution and morphology of cells or extracting single axons from functional data. Compared to existing supervised learning methods, FLoRIN is one to two orders of magnitude faster and produces high-quality reconstructions that are tolerant to noise and artifacts, as is shown qualitatively and quantitatively.

Shahbazi, Ali↗

Physics constrained unsupervised deep learning for rapid, high resolution scanning coherent diffraction reconstruction

By circumventing the resolution limitations of optics, coherent diffractive imaging (CDI) and ptychography are making their way into scientific fields ranging from X-ray imaging to astronomy. Yet, the need for time consuming iterative phase recovery hampers real-time imaging. While supervised deep learning strategies have increased reconstruction speed, they sacrifice image quality. Furthermore, these methods’ demand for extensive labeled training data is experimentally burdensome. Here, we propose an unsupervised physics-informed neural network reconstruction method, PtychoPINN, that retains the factor of 100-to-1000 speedup of deep learning-based reconstruction while improving reconstruction quality by combining the diffraction forward map with real-space constraints from overlapping measurements. In particular, PtychoPINN gains a factor of 4 in linear resolution and an 8 dB improvement in PSNR while also accruing improvements in generalizability and robustness. This blend of performance and computational efficiency offers exciting prospects for high-resolution real-time imaging in high-throughput environments such as X-ray free electron lasers (XFELs) and diffraction-limited light sources.

97 MATHEMATICS AND COMPUTING↗

Radiation image reconstruction and uncertainty quantification using a Gaussian process prior

We propose a complete framework for Bayesian image reconstruction and uncertainty quantification based on a Gaussian process prior (GPP) to overcome limitations of maximum likelihood expectation maximization (ML-EM) image reconstruction algorithm. The prior distribution is constructed with a zero-mean Gaussian process (GP) with a choice of a covariance function, and a link function is used to map the Gaussian process to an image. Unlike many other maximum a posteriori approaches, our method offers highly interpretable hyperparamters that are selected automatically with the empirical Bayes method. Furthermore, the GP covariance function can be modified to incorporate a priori structural priors, enabling multi-modality imaging or contextual data fusion. Lastly, we illustrate that our approach lends itself to Bayesian uncertainty quantification techniques, such as the preconditioned Crank–Nicolson method and the Laplace approximation. The proposed framework is general and can be employed in most radiation image reconstruction problems, and we demonstrate it with simulated free-moving single detector radiation source imaging scenarios. We compare the reconstruction results from GPP and ML-EM, and show that the proposed method can significantly improve the image quality over ML-EM, all the while providing greater understanding of the source distribution via the uncertainty quantification capability. Furthermore, significant improvement of the image quality by incorporating a structural prior is illustrated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Deployment and validation of predictive 6-dimensional beam diagnostics through generative reconstruction with standard accelerator elements

Understanding the 6-dimensional phase space distribution of particle beams is essential for optimizing accelerator performance. Conventional diagnostics such as use of transverse deflecting cavities offer detailed characterization but require dedicated hardware and space. Generative phase space reconstruction (GPSR) methods have shown promise in beam diagnostics, yet prior implementations still rely on such components. Here we present the first experimental implementation and validation of the GPSR methodology, realized by the use of standard accelerator elements including accelerating cavities and dipole magnets, to achieve complete 6-dimensional phase space reconstruction. Through simulations and experiments at the Pohang Accelerator Laboratory X-ray Free Electron Laser facility, we successfully reconstruct complex, nonlinear beam structures. Furthermore, we validate the methodology by predicting independent downstream measurements excluded from training, revealing the reconstruction closely resembling ground truth. This advancement establishes a pathway for predictive diagnostics across beamline segments while reducing hardware requirements and expanding applicability to various accelerator facilities.

Kim, Seongyeol [Pohang Univ. of Science and Techno↗

Online Electron Reconstruction at CLAS12

Online reconstruction plays a crucial role in monitoring and in real-time analysis of high energy and nuclear physics experiments. A vital aspect of reconstruction algorithms is particle identification, which combines information from various detector components to determine the type of particle. Electron identification is particularly significant in electro-production nuclear physics experiments like the CLAS12 spectrometer at Jefferson Laboratory as it is essential in data recording. A machine learning approach has been developed for CLAS12 experiments to reconstruct and identify electrons by combining raw signals from multiple detector components at the data acquisition level. This method achieves high electron identification purity while maintaining nearly 100% efficiency. Furthermore, the machine learning tools operate at rates exceeding data acquisition speed, enabling the real-time electron reconstruction. This advancement significantly improves online analyses and monitoring capabilities for CLAS12 experiments.

Tyson,, Richard [Thomas Jefferson National Acceler↗

Surface reconstruction evolution and anatase formation in the process of oxidation of titanium nitride film

Titanium nitride film was grown on MgO(001) substrate by plasma-assisted molecular beam epitaxy and then oxidized by oxygen plasma. Reflection high-energy electron diffraction (RHEED) was employed to in situ monitor the process of growth and oxidation. After the TiN film was oxidized for a moment, spots among main streaks were observed in RHEED pattern, which should be attributed to the isolated surface reconstruction domains disorderedly distributing on flat surface. Subsequently, the spots gradually evolved to streaks so that more clear RHEED patterns of (2x1) surface reconstruction were observed. It was argued that the disordered and isolated reconstruction domains congregated to large domains or even perfect reconstruction surface with oxidation time evolving. After oxidation, a series of characterization methods were applied to study the TiO{sub 2} phase, which consistently confirmed that the phase of oxidized titanium nitride is anatase but not rutile.

36 MATERIALS SCIENCE↗

Theory of the Sr-induced reconstruction of the Si (001) surface

By using first-principles calculations, we theoretically investigate the surface reconstruction caused by the adsorption of Sr on the Si (001) surface. For the Sr coverage below (1/2) monolayer (ML), the system behavior is dominated by the charge transfer between Sr and silicon that results in the 'unbuckling' of Si dimers. At a higher coverage, the surface begins to 'undimerize'. At the 1 ML coverage, a geometric size constraint induces a series of reconstructions such as 3x, 5x, 7x, etc., characterized by 1x1 reconstructed patches separated by a dimer row. Calculations of the surface energy as function of coverage suggest that for 1 ML of Sr 3x, 5x, and 7x reconstructions of the surface are preferred under the Sr rich conditions, which is in good agreement with the experiment.

36 MATERIALS SCIENCE↗

The theory of variances in equilibrium reconstruction

The theory of variances of equilibrium reconstruction is presented. It complements existing practices with information regarding what kind of plasma characteristics can be reconstructed, how accurately, and what remains beyond the abilities of diagnostic systems. The {sigma}-curves, introduced by the present theory, give a quantitative assessment of quality of effectiveness of diagnostic systems in constraining equilibrium reconstructions. The theory also suggests a method for aligning the accuracy of measurements of different physical nature and for improvements of numerical algorithms used in reconstruction.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Advances in the calibration of atom probe tomographic reconstruction

Modern wide field-of-view atom probes permit observation of a wide range of crystallographic features that can be used to calibrate the tomographic reconstruction of the analyzed volume. In this study, methodologies to determine values of the geometric parameters involved in the tomographic reconstruction of atom probe data sets are presented and discussed. The influence of the tip to electrode distance and specimen temperature on these parameters is explored. Significantly, their influence is demonstrated to be very limited, indicating a relatively wide regime of experimental parameters space for sound atom probe tomography (APT) experiments. These methods have been used on several specimens and material types, and the results indicate that the reconstruction parameters are specific to each specimen. Finally, it is shown how an accurate calibration of the reconstruction enables improvements to the quality and reliability of the microscopy and microanalysis capabilities of the atom probe.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Photon Reconstruction and Identification with the ATLAS detector

The understanding of the photons reconstruction will be one of the key issues at the start-up of data-taking with the ATLAS experiment at the LHC. Large statistics samples of photons produced in association with jets are expected over a wide range of E{sub T}.The photon reconstruction is based on an electromagnetic-cluster-seeded algorithm which classifies as photons those clusters which have no matching prompt track. These are then subdivided into converted or non-converted photon candidates depending on the presence of one or more tracker-reconstructed electron-positron pairs pointing to it. The precise knowledge of the material upstream the calorimeter and a correct treatment of the converted photons are critical for a correct photon reconstruction and identification.The photon identification is based almost entirely on the analysis of the shower shapes in the calorimeter. The goal is to achieve an efficient photon selection in the range from 20 GeV to several hundreds GeV with a rejection of 10{sup 3}-10{sup 4} against QCD jets in the moderate transverse momentum region of 20 to 100 GeV, which is the relevant one for H->gammagamma searches.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electron cyclotron emission reconstruction image and m/n=3/2 mode in HT-7 tokamak

Electron cyclotron emission reconstruction image has been used for flux surface reconstruction. The reconstruction image is based on plasma rigid rotation which is obtained from Mirnov diagnostic. From the reconstructed two-dimensional flux surface, the classical m/n=3/2 mode is visualized, which is of similar spatial structure as neoclassical 3/2 mode observed in some other tokamaks [B. Esposito et al., Phys. Rev. Lett. 100, 045006 (2008)].

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The role of kinetics on the Mn-induced reconstructions of the GaAs(001) surface

A combined scanning tunneling microscopy and low-energy electron diffraction investigation of the Mn/GaAs(001) interface formation is reported. The interface, grown on a (2 x 4) reconstructed substrate produced by molecular beam epitaxy, was studied as a function of Mn evaporation with thickness ranging from 1/8 ML to 1 ML. The interaction of Mn atoms with the semiconductor surface is strong and leads to surface reconstructions involving a rearrangement of the two outmost atomic layers of the substrate. For Mn thickness lower than 1/2 ML, the surface is characterized by a (2 x 1) periodicity. Conversely, when the Mn deposition is increased to 1/2 ML the surface reconstruction is strongly dependent on the preparation procedure. If Mn deposition is performed on the substrate at 390 deg. C, a fully ordered surface characterized by a clear (2 x 2) reconstruction is obtained, whereas, annealing the sample after Mn deposition, gives a disordered surface with a (2 x 1) symmetry. An intermediate phase between (2 x 1) and (2 x 2) is found for Mn depositions in between 1/4 and 1/2 ML. No further structural evolution was observed for both preparation methods above 1/2 ML coverage.

36 MATERIALS SCIENCE↗

Note: Development of a compact x-ray particle image velocimetry for measuring opaque flows. II. Three-dimensional velocity field reconstruction

An x-ray particle image velocimetry (PIV) system using a cone-beam type x-ray was developed. The field of view and the spatial resolution are 36 x 24.05 mm{sup 2} and 20 {mu}m, respectively. The three-dimensional velocity field was reconstructed by adopting the least squares minimum residue and simultaneous multiplicative algebraic reconstruction techniques. According to a simulation study with synthetic images, the reconstructions were acceptable with 7 projections and 50 iterations. The reconstructed and supplied flow rates differed by only about 6.49% in experimental verification. The x-ray tomographic PIV system would be useful for 3D velocity field information of opaque flows.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Genetic algorithms applied to reconstructing coded imaging of neutrons and analysis of residual watermark

Monte-Carlo simulation of neutron coded imaging based on encoding aperture for Z-pinch of large field-of-view with 5 mm radius has been investigated, and then the coded image has been obtained. Reconstruction method of source image based on genetic algorithms (GA) has been established. 'Residual watermark,' which emerges unavoidably in reconstructed image, while the peak normalization is employed in GA fitness calculation because of its statistical fluctuation amplification, has been discovered and studied. Residual watermark is primarily related to the shape and other parameters of the encoding aperture cross section. The properties and essential causes of the residual watermark were analyzed, while the identification on equivalent radius of aperture was provided. By using the equivalent radius, the reconstruction can also be accomplished without knowing the point spread function (PSF) of actual aperture. The reconstruction result is close to that by using PSF of the actual aperture.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spontaneous polarization driven Mg concentration profile reconstruction in MgZnO/ZnO heterostructures

Atomic reconstruction at the interface of MgZnO and ZnO in molecular beam epitaxy grown heterostructures is investigated. Using secondary ion mass spectroscopy, we experimentally find that Mg atomic reconstruction depends on the polarity of the interface; it is not observed in n-type interfaces (MgZnO on Zn-polar ZnO) owing to electron accumulation, while in p-type interfaces (ZnO on Zn-polar MgZnO), Mg drastically redistributes into the ZnO layer. Combined with self-consistent calculation of band profiles and carrier distributions, we reveal that the observed Mg reconstruction is not due to thermal diffusion but consequences in order to avoid hole accumulation. This tendency implies inherent significant asymmetry of energy scales of atomic and electronic reconstructions between n-type and p-type interfaces.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Iterative reconstruction using a Monte Carlo based system transfer matrix for dedicated breast positron emission tomography

To maximize sensitivity, it is desirable that ring Positron Emission Tomography (PET) systems dedicated for imaging the breast have a small bore. Unfortunately, due to parallax error this causes substantial degradation in spatial resolution for objects near the periphery of the breast. In this work, a framework for computing and incorporating an accurate system matrix into iterative reconstruction is presented in an effort to reduce spatial resolution degradation towards the periphery of the breast. The GATE Monte Carlo Simulation software was utilized to accurately model the system matrix for a breast PET system. A strategy for increasing the count statistics in the system matrix computation and for reducing the system element storage space was used by calculating only a subset of matrix elements and then estimating the rest of the elements by using the geometric symmetry of the cylindrical scanner. To implement this strategy, polar voxel basis functions were used to represent the object, resulting in a block-circulant system matrix. Simulation studies using a breast PET scanner model with ring geometry demonstrated improved contrast at 45% reduced noise level and 1.5 to 3 times resolution performance improvement when compared to MLEM reconstruction using a simple line-integral model. The GATE based system matrix reconstruction technique promises to improve resolution and noise performance and reduce image distortion at FOV periphery compared to line-integral based system matrix reconstruction.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Modeling, measurement, and 3-D equilibrium reconstruction of the bootstrap current in the Helically Symmetric Experiment

The bootstrap current for three electron cyclotron resonance heated plasma scenarios in a quasihelically symmetric stellarator (the Helically Symmetric Experiment) are analyzed and compared to a neoclassical transport code PENTA. The three conditions correspond to 50 kW input power with a resonance that is off-axis, 50 kW on-axis heating and 100 kW on-axis heating. When the heating location was moved from off-axis to on-axis with 50 kW heating power, the stored energy and the extrapolated steady-state current were both observed to increase. When the on-axis heating power was increased from 50 kW to 100 kW, the stored energy continued to increase while the bootstrap current slightly decreased. This trend is qualitatively in agreement with the calculations which indicate that a large positive electric field for the 100 kW case was driving the current negative in a small region close to the magnetic axis and accounting for the decrease in the total integrated current. This trend in the calculations is only observed to occur when momentum conservation between particle species is included. Without momentum conservation, the calculated bootstrap current increases monotonically. We show that the magnitude of the bootstrap current as calculated by PENTA agrees better with the experiment when momentum conservation between plasma species is included in the calculation. The total current was observed in all cases to flow in a direction to unwind the transform, unlike in a tokamak in which the bootstrap current adds to the transform. The 3-D inductive response of the plasma is simulated to predict the evolution of the current profile during the discharge. The 3-D equilibrium reconstruction code V3FIT is used to reconstruct profiles of the plasma pressure and current constrained by measurements with a set of magnetic diagnostics. The reconstructed profiles are consistent with the measured plasma pressure profile and the simulated current profile when the reconstruction is constrained by the measured data from a diagnostic array that is internal to the vacuum chamber.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗