Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “radiometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

SI-Traceable Calibration of Satellite Microwave Radiometers

Background (what): SI (International System of Units)-traceable Microwave Radiometer calibration; Motivation (why): NWP (Numerical Weather Prediction), FCDR (Fundamental Climate Data Record); Technology (how): NIST (National Inst. of Standards and Technology) blackbody target for ; Standards: Status & Future Plans. Development of a National Standard for Microwave Brightness Temperature (TB) at NIST.

MW Radiometer TB Calibration↗

NOAA-20 Visible Infrared Imaging Radiometer Suite day–night band on-orbit calibration and performance

The NOAA-20 Visible Infrared Imaging Radiometer Suite (VIIRS) instrument has been successfully operating on orbit since November 28, 2017. The day–night band (DNB) onboard NOAA-20 VIIRS is a panchromatic channel covering wavelengths from 0.5 to 0.9 μm, capable of observing the Earth scene in visible/near-infrared spectral range at a spatial resolution of 750 m. The DNB operates at low-, mid-, or high-radiometric gain stages, and it uses an onboard solar diffuser (SD) panel for low-gain stage calibration. The SD observations also provide a means to compute gain ratios between low-to-mid and mid-to-high-gain stages. With their large dynamic range and high sensitivity, the DNB detectors can make observations during both daytime and nighttime. We provide an assessment of the DNB on-orbit performance and behavior in the first two-year mission period and beyond. The calibration methodology used by the VIIRS Characterization Support Team in support of the NASA Earth science community has been described. The trending of on-board calibrators dark-offsets, SD gains, and gain ratios, and signal-to-noise ratio at minimum radiance have been analyzed, especially during key events such as the nadir and cryocooler doors opening. Furthermore, we performed intercomparison studies between Suomi National Polar-orbiting Partnership and NOAA-20 instruments and evaluated DNB radiometric calibration and characterization, including the SD degradation, detector gains, gain ratios, and straylight correction, as well as the calibration comparison between the NOAA Interface Data Processing Segment look-up-tables and our delivery results.

VIIRS↗

Multi-Channel Correlator Array-Fed Microwave Radiometer

Multiband passive microwave imagery in X to W Bands has a nearly 40-year history of utilization for measurement of multiple geophysical parameters (e.g., precipitation rate, ocean surface wind speed, sea ice concentration, and land surface temperature). Spatial resolution is limited by aperture size, and although aperture sizes have grown to 1-2 meters, current capability will not meet future spatial resolution needs. As aperture size increases, new antenna feed techniques are needed to maintain contiguous coverage and obtain Nyquist sampling. Here we apply the correlator array fed radiometer architecture adapted from radio astronomy and show how it can meet emerging needs. Simulation results of a 0.8-m, 36.5-GHz, array-fed reflector (equivalent to 20 meters at 1.41 GHz) show the feasibility of creating multiple over-lapping beams.

Microwave radiometer↗

Removing Biases from Rotating Shadowband Radiometers: Preprint

Three types of biases are examined for a rotating shadowband radiometer (RSR): temperature bias, spectral bias, and deviation from a Lambertian cosine response. A step-by-step method is presented to illustrate how to use this information to develop a model for adjustment algorithms for a RSR. Comparisons are made with a RSR adjusted using the model and measure direct normal, diffuse, and global irradiance.

14 SOLAR ENERGY↗

Producing radiometals in liquid targets: Proof of feasibility with {sup 94m}Tc

{sup 94m}Tc was produced in a liquid target loaded with a molybdenum-salt solution. This novel technique allows for the irradiation of metals dissolved in a liquid solution, normally only available in metal powder or foil form. By using this approach, the existing liquid targets and transfer infrastructure of many PET cyclotrons can be used to produce radiometals, avoiding the need, expense and challenges of operating solid targets. Such an approach allows for rapid testing of new isotopes for proof of feasibility studies. Different concentrations of Mo solution and their effect on the target performance were tested. Sufficient quantities to allow for preclinical studies were produced.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

G-Band Vapor Radiometer Precipitable Water Vapor (GVRPWV) Value-Added Product

The G-Band Vapor Radiometer Precipitable Water Vapor (GVRPWV) value-added product (VAP) computes precipitable water vapor using neural network techniques from data measured by the GVR. The GVR reports time-series measurements of brightness temperatures for four channels located at 183.3 ± 1, 3, 7, and 14 GHz.

54 ENVIRONMENTAL SCIENCES↗

Maturation and Hardening of the Stabilized Radiometer Platforms (STRAPS) Field Campaign Report

Measurements of solar and infrared irradiance by instruments rigidly mounted to an aircraft have historically been plagued by the introduction of offsets and fluctuations into the data that are solely due to the pitch and roll movements of the aircraft. Two STabilized RAdiometer Platforms (STRAPs) were developed for the U.S. Navy in the early to mid-2000s to address this problem. The development was a collaborative effort between the Naval Research Laboratory (NRL), the Naval Postgraduate School Center for Interdisciplinary Remotely Piloted Aircraft Studies (CIRPAS), and the U.S. Department of Energy (DOE) Sandia National Laboratories. The STRAPs were designed and built by L-3 Communications Sonoma EO (formerly the small business Sonoma Design Group).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Support for Students, Postdoctoral Fellow and Trainees who have been Accepted to Present at TERACHEM 2018 on Radiometal Nuclear Sciences

This grant was used to support students, postdocs and trainees to attend TERACHEM 2018, the premier conference/symposium on radiometal nuclear sciences. The trainees supported all presented their research at TERACHEM 2018 held in Bressanone, Italy from 26-29 September 2018. All trainees performed their research at US institutions. Eight trainees were supported.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Microwave Radiometer — 3-Channel (MWR3C) Instrument Handbook

The microwave radiometer – 3-channel (MWR3C, RPG-LWP-U90) deployed by the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility provides time-series measurements of brightness temperatures from three channels centered at 23.834, 30, and 89 GHz. These three channels are sensitive to the presence of liquid water and precipitable water vapor.

47 OTHER INSTRUMENTATION↗

ARM Site E36 - CLAMPS 2 Microwave Radiometer / Processed Data

This dataset contains processed data from the CLAMPS 2 Humidity And Temperature PROfiler (HATPRO) Microwave Radiometer and its associated meteorology tower. CLAMPS 2 deployed during fall-winter 2022 (10/3/22-12/27/23) and summer-fall 2023 (6/16/23-10/1/23).

17 WIND ENERGY↗