Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “quantum imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

N - V –Diamond Magnetic Microscopy Using a Double Quantum 4-Ramsey Protocol

We introduce a double quantum (DQ) 4-Ramsey measurement protocol that enables wide-field magnetic imaging using nitrogen-vacancy (N-V) centers in diamond, with enhanced homogeneity of the magnetic sensitivity relative to conventional single quantum (SQ) techniques. The DQ 4-Ramsey protocol employs microwave-phase alternation across four consecutive Ramsey (4-Ramsey) measurements to isolate the desired DQ magnetic signal from any residual SQ signal induced by microwave pulse errors. In a demonstration experiment employing a 1-μm-thick N-V layer in a macroscopic diamond chip, the DQ 4-Ramsey protocol provides a volume-normalized dc magnetic sensitivity of η V = 34nTHz –1/2 μm 3/2 across a 125 μm × 125 μm field of view, with about 5× less spatial variation in sensitivity across the field of view compared to a SQ measurement. Furthermore, the improved robustness and magnetic sensitivity homogeneity of the DQ 4-Ramsey protocol enables imaging of dynamic broadband magnetic sources such as integrated circuits and electrically active cells.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Towards Dualband Megapixel QWIP Focal Plane Arrays

Mid-wavelength infrared (MWIR) and long-wavelength infrared (LWIR) 1024 x 1024 pixel quantum well infrared photodetector (QWIP) focal planes have been demonstrated with excellent imaging performance. The MWIR QWIP detector array has demonstrated a noise equivalent differential temperature (NEDT) of 17 mK at a 95 K operating temperature with f/2.5 optics at 300 K background and the LWIR detector array has demonstrated a NEDT of 13 mK at a 70 K operating temperature with the same optical and background conditions as the MWIR detector array after the subtraction of system noise. Both MWIR and LWIR focal planes have shown background limited performance (BLIP) at 90 K and 70 K operating temperatures respectively, with similar optical and background conditions. In addition, we have demonstrated MWIR and LWIR pixel co-registered simultaneously readable dualband QWIP focal plane arrays. In this paper, we will discuss the performance in terms of quantum efficiency, NEDT, uniformity, operability, and modulation transfer functions of the 1024 x 1024 pixel arrays and the progress of dualband QWIP focal plane array development work.

Infrared detectors↗

The AXAF CCD Imaging Spectrometer Experiment (ACIS)

The ACIS experiment consists of an array of charge coupled device (CCD) chips placed at the focus of the AXAF mirror assembly. The instrument offers a powerful combination of the best qualities of the entire generation of Einstein Observatory detectors. The pixel size is well matched to the resolution of the telescope, while the high quantum efficiency nondispersive spectroscopy capability means that every object imaged will produce a moderate resolution spectrum. In conjunction with the objective gratings the energy resolution increases to 1000 with a loss of efficiency of only 50 percent. While the great capability of ACIS will naturally make it attractive for a wide range of AXAF investigations, ACIS has a particular advantage in fields where it can simultaneously acquire imaged spectra of many objects. These include compact star clusters, star formation regions, the nuclear regions of nearby galaxies, entire galaxies in the Virgo Cluster and the entire Coma Cluster.

Nousek, J. A.↗

Inscription and Visualization of Tilted Fiber Bragg Gratings

Tilted fiber Bragg gratings with different tilt angles have been inscribed in single-mode isotropic optical fiber with an increased photorefractivity using Talbot interferometer and KrF-excimer laser system. Their spectra are studied. Using a confocal laser scanning luminescent microscope the images of gratings in transmitted light were obtained. The calculated dependence of the slope angle of the grating recorded in the Talbot interferometer on the angle between the strokes of the interference pattern created in the interferometer and the transverse section of the optical fiber is experimentally verified.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Go Pink! The Effect of Secondary Quanta on Detective Quantum Efficiency

Photons are never directly observable. Consequently, we often use photoelectric detectors (eg CCDs) to record associated photoelectrons statistically. Nonetheless, it is an implicit goal of radiographic detector designers to achieve the maximum possible detector efficiency1. In part the desire for ever higher efficiency has been due to the fact that detectors are far less expensive than associated accelerator facilities (e.g. DARHT and PHERMEX2). In addition, higher efficiency detectors often have better spatial resolution. Consequently, the optimization of the detector, not the accelerator, is the system component with the highest leverage per dollar. In recent years, imaging scientists have adopted the so-called Detective Quantum Efficiency, or DQE as a summary measure of detector performance. Unfortunately, owing to the complex nature of the trade-space associated with detector components, and the natural desire for simplicity and low(er) cost, there has been a recent trend in Los Alamos to focus only on the zerofrequency efficiency, or DQE(0), when designing such systems. This narrow focus leads to system designs that neglect or even ignore the importance of high-spatial-frequency image components. In this paper we demonstrate the significant negative impact of these design choices on the Noise Power Spectrum1 (NPS) and recommend a more holistic approach to detector design. Here we present a statistical argument which indicates that a very large number (>20) of secondary quanta (typically visible light and/or recorded photo-electrons) are needed to take maximum advantage of the primary quanta (typically x-rays or protons) which are available to form an image. Since secondary particles come in bursts, they are not independent. In short, we want to maximize the pink nature of detector noise at DARHT.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Mode imaging and loss evaluation of semiconductor waveguides

An imaging and loss evaluation method for semiconductor waveguides coupled with non-doped quantum wells is presented. Using the internal emission of the wells as a probe light source, the numbers and widths of the modes of waveguides with various ridge sizes were evaluated by CCD imaging, and the obtained values were consistent with effective index method calculation. Waveguide internal losses were obtained from analyses of the Fabry-Pérot fringes of waveguide emission spectra. We quantified the quality of 29 single-mode waveguide samples as an internal loss and variation of 10.2 ± 0.6 cm{sup −1}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Stable vacuum UV CCD detectors designed for space flight experiments

Thinned, backside-illuminated, p-channel CCD images are under development which can exploit the surface potential in VUV applications, yielding enhanced quantum efficiency to wavelengths as short as 1100 A. The current goal is production of large-format, 5-micron pixel imagers for spectrographic and imaging VUV spaceflight experiments. Model predictions of the effect of device design on quantum efficiency, well capacity, and crosstalk are presented for such 5-micron-approaching pixel sizes.

Socker, Dennis G.↗

Design and analysis of Vivaldi antenna with enhanced radiation characteristics for mm-wave and THz applications

This article presents a novel approach to design Vivaldi antennas for millimeter and Terahertz band applications. The radiation performance of the proposed Vivaldi antenna is enhanced by employing cross shape resonator and abridged rectangular slots at the edge of radiating arms. In the THz regime, the simulated − 10 dB impedance bandwidth is approximately 76 GHz, minimum return loss of − 58.83 dB, VSWR of 1.002, peak gain of 11.77 dB, radiation efficiency of 97.40% and directivity of 11.89 dBi are achieved at the corresponding resonance frequency of 0.603 THz. Further, in order to validate the suggested design method, targeted antennas are fabricated, tested at 0.06125-THz and 0.06215-THz frequency. The significant performance improvement in radiation characteristics are observed over the frequency band from 0.06- to 0.065-THz. The proposed THz antenna useful for the application of video-rate imaging, object imaging, detection of illicit drugs using spectroscopy, Doppler radar and/or on-body techniques and wireless communications. Similarly, the planned mm-wave antenna is useful for the imaging system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantum machine learning with differential privacy

Abstract Quantum machine learning (QML) can complement the growing trend of using learned models for a myriad of classification tasks, from image recognition to natural speech processing. There exists the potential for a quantum advantage due to the intractability of quantum operations on a classical computer. Many datasets used in machine learning are crowd sourced or contain some private information, but to the best of our knowledge, no current QML models are equipped with privacy-preserving features. This raises concerns as it is paramount that models do not expose sensitive information. Thus, privacy-preserving algorithms need to be implemented with QML. One solution is to make the machine learning algorithm differentially private, meaning the effect of a single data point on the training dataset is minimized. Differentially private machine learning models have been investigated, but differential privacy has not been thoroughly studied in the context of QML. In this study, we develop a hybrid quantum-classical model that is trained to preserve privacy using differentially private optimization algorithm. This marks the first proof-of-principle demonstration of privacy-preserving QML. The experiments demonstrate that differentially private QML can protect user-sensitive information without signficiantly diminishing model accuracy. Although the quantum model is simulated and tested on a classical computer, it demonstrates potential to be efficiently implemented on near-term quantum devices [noisy intermediate-scale quantum (NISQ)]. The approach’s success is illustrated via the classification of spatially classed two-dimensional datasets and a binary MNIST classification. This implementation of privacy-preserving QML will ensure confidentiality and accurate learning on NISQ technology.

97 MATHEMATICS AND COMPUTING↗

Flow around a corner in the water impact problem

In this work, we study the local flow in the vicinity of a flat sector of arbitrary angle α in the water impact problem as motivated by recent experimental observations in the author's laboratory. The key question is as to why the ejecta formed during the impact at zero deadrise angle is considerably higher along a straight edge of the sector compared to that near a sharp corner α < π, e.g., if the impacting body is a rectangular plate. Resolving this question is made possible by the discovered here mathematical equivalence of the problem to electromagnetic diffraction phenomena. The main result of the present study is the revealed and quantified influence of the geometry of a flat plate corner on the fluid flow around it, which also contributes to the understanding of certain three-dimensional effects in the water impact problem and provides a generalization of the classical two-dimensional results on the impact at zero deadrise angle. The offered theoretical solution is also qualitatively supported with the help of particle image velocimetry measurements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Time-resolved photoluminescence properties of semiconductor quantum dot superlattices of different microcrystal shapes

We report time-resolved photoluminescence properties on semiconductor quantum dot (QD) superlattices (SLs) using PL lifetime imaging microscopy at a single particle level. PL lifetime imaging technique clearly reveals that different shaped QD SL microcrystals have different time-resolved PL characteristics. The faceted SL microcrystals consisted of well-organized QDs showed faster recombination rates than those of the spherical microparticles including randomly organized QDs, which can be explained by the different degree of energetic couplings among component QDs due to different packing fraction.

36 MATERIALS SCIENCE↗

Quantitative compositional analysis and strain study of InAs quantum wires with InGaAlAs barrier layers

Quantitative compositional analysis of InAs quantum wires deposited between In{sub 0.53}Ga{sub 0.37}Al{sub 0.1}As barrier layers grown on InP substrates was performed by electron energy loss spectrometry and energy dispersive x-ray spectrometry. An indium-rich region in the center of the wire, with decreasing indium concentration toward the interface with the barrier layers, was observed from indium concentration maps for individual quantum wires. 'Stripelike' contrast modulation was observed in diffraction contrast transmission electron microscope images of the In{sub 0.53}Ga{sub 0.37}Al{sub 0.1}As barrier layer immediately above the quantum wires. The contrast originated from indium compositional modulations in the upper barrier layer as confirmed by electron energy loss spectrometry and the modulation is attributed to the presence of an inhomogeneous elastic strain field generated by the buried quantum wires. These results suggest that quantitative analysis of the composition and strain distributions at very high spatial resolution provides insights necessary to further model the physical properties and to understand the growth of these nanostructures.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Diagnosis of PV Cell Antireflective Coating Degradation Resulting From Hot-Humid High-Voltage Potential Aging

Corrosion of the antireflective coating on a photovoltaic cell ("ARc corrosion") has previously been observed in studies using hot-humid test conditions with external high-voltage (HV) bias. This study primarily focuses on known vulnerable legacy aluminum back surface field cells in mini-modules (MiMos) put through comparative stepped stress tests. Each cell type had MiMos at +1500 V, -1500 V, or unbiased ("Voc") potential, which were sequentially subjected to test conditions of 60 degrees C/60% relative humidity (RH) for 96 h, as in International Electrotechnical Commission Technical Specification 62804-1; 70 degrees C/70% RH for 200 h; and 85 degrees C/85% RH for 200 h. Characterizations at each step included visual camera and electroluminescence (EL) imaging, colorimetry, and current-voltage curve tracing. Final characterizations included: Suns-Voc, spatial mapping of external quantum efficiency, high-resolution photoluminescence, EL, and dark lock-in thermography imaging. Forensics were performed on extracted cores, including scanning electron microscopy (SEM) with energy-dispersive X-ray spectroscopy (EDS), X-ray photoelectron spectroscopy, and scanning Auger microscopy (SAM). Forensics were also conducted on MiMos from previous studies that underwent stepped HV aging and separate outdoor aged full-sized modules. ARc corrosion was specifically seen for the glass/encapsulant/cell side of the +1500 V (HV+) stressed MiMos and modules. Appearance, color, and reflectance were the most distinguishing characteristics relative to glass corrosion, gridline corrosion and delamination, and other concurrent degradation modes. SEM/EDS and SAM identified the conversion of silicon nitride to hydrated silica, hydrous silica, or hydrated amorphous silica, which preferentially occurred at the edges and tips of the pyramidal textured cell surface.

14 SOLAR ENERGY↗

Optimization of Noise Performance of Low-Back Ground Detector Arrays

The performance of the 2k x 2k Teledyne H2RG detectors is key to the success of the JWST mission. For broadband imaging, where background limited sensitivity is quickly reached, the key parameter is the quantum efficiency of the detectors, which is, in general, very good. For near infrared spectroscopy and narrow band imaging, we cannot generally reach the back-round limit, so instrument sensitivity is directly dependent on the read noise of the detector. We have initiated a program to analyze the noise characteristics of the H2RG detectors, studying the correlations among the detector outputs and with the reference output, as well as the temporal correlations in a given detector section. Lasing the measured characteristics of the noise correlations, we can determine the optimal coefficients for the removal of correlated noise as a function of frequency. By using available reference sources and adding more frequent references, we have been able to reduce the noise by a factor of two. We find that the detectors have significantly lower noise that observed in prior tests, and can offer significant improvements in the performance of the JWST instruments. We will present the analysis and mitigation techniques, discuss prospects for further improvements with existing detectors, and describe considerations for improvements in next-generation detectors.

Rauscher, Bernard J.↗

Imaging dynamic exciton interactions and coupling in transition metal dichalcogenides

Transition metal dichalcogenides (TMDs) are regarded as a possible material platform for quantum information science and related device applications. In TMD monolayers, the dephasing time and inhomogeneity are crucial parameters for any quantum information application. In TMD heterostructures, coupling strength and interlayer exciton lifetimes are also parameters of interest. However, many demonstrations in TMDs can only be realized at specific spots on the sample, presenting a challenge to the scalability of these applications. Here, using multi-dimensional coherent imaging spectroscopy, we shed light on the underlying physics—including dephasing, inhomogeneity, and strain—for a MoSe 2 monolayer and identify both promising and unfavorable areas for quantum information applications. We, furthermore, apply the same technique to a MoSe 2 /WSe 2 heterostructure. Despite the notable presence of strain and dielectric environment changes, coherent and incoherent coupling and interlayer exciton lifetimes are mostly robust across the sample. This uniformity is despite a significantly inhomogeneous interlayer exciton photoluminescence distribution that suggests a bad sample for device applications. This robustness strengthens the case for TMDs as a next-generation material platform in quantum information science and beyond.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Tunable-Quantum-Well Infrared Detector

Proposed detector of infrared photons based on photon-assisted, resonant quantum-mechanical tunneling between adjacent energy wells in its semiconductor structure. Wavelength adjusted by changing applied voltage. Device contains alternating layers of different seminconductors which form double-quantum-well electron-energy structure. Tunable-quantum-well detectors made on single chip constitutes line imager. Many such devices stacked to form two-dimensional imaging device. Signal-processing circuitry integrated into chip at its lower end. Potential barriers and wells produced by alternating layers of different semiconductor materials. Steepness of slope proportional to applied electric field. Electric field and thicknesses and heights of barriers selected to favor photon-assisted, resonant quantum-mechanical tunneling at chosen photon frequency.

Maserjian, Joseph↗

Proposed framework for applying squeezed light to multi-photon absorption plasma diagnostics

We propose a quantum-enhanced plasma diagnostic based on squeezed states of light. Squeezed light can exhibit super-Poissonian photon statistics, leading to enhanced multiphoton absorption cross-sections compared to classical light. This effect enables improved sensitivity for two-photon excitation of high-energy atomic transitions such as ground-state excitation, and results in increased absorbed power and fluorescence in a plasma. We consider two methods of generating squeezed states and evaluate their advantages and limitations in the context of plasma absorption diagnostics. By comparing with and extending previous theoretical work, we predict an enhancement of the absorption signal by up to seven orders of magnitude at low intensities (10 1 W/m 2 ), with diminishing enhancement persisting up to high intensities (10 10 W/m 2 ). These results suggest that squeezed-light sources offer a viable pathway toward quantum-enhanced plasma diagnostics.

imaging↗

Engraving Print Classification

A print is a mark, or drawing, made in or upon a plate, stone, woodblock or other material which is cover with ink and then is press usually into a paper reproducing the image on the paper. Engraving prints usually are image composed of a group of binary lines, specially those are made with relief and intaglio techniques. Varying the number and the orientation of lines, the drawing of the engraving print is conformed. For this reason we propose an application based on image processing methods to classify engraving prints.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗