Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pumped, storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Energy Efficiency and Renewable Energy for New Home Construction in Maui

For residential property owners preparing to rebuild homes in Maui, this fact sheet, produced by the National Renewable Energy Laboratory (NREL), a national laboratory of the U.S. Department of Energy (DOE), provides a brief introduction to the topics of renewable energy and energy efficiency for new residential construction, presents a few high-level considerations and key concepts, and provides a sampling of information on rebates, incentives, certification programs, standards, and relevant policies. This fact sheet is not intended to be comprehensive nor to replace local resources.

appliances↗

Portable Intravenous Fluid Production Device For Ground Use Project

Several medical conditions require the administration of intravenous (IV) fluids,but limitations of mass, volume, shelf-life, transportation, and local resources can restrict the availability of these important fluids. Such limitations are expected in long-duration space exploration missions and in remote or austere places on Earth. This design uses regular drinking water that is pumped through two filters to produce, in minutes, sterile, ultrapure water that meets the stringent quality standards of the United States Pharmacopeia for Water for Injection (Total Bacteria, Conductivity, Endo - toxins, Total Organic Carbon). The device weighs 2.2 lb (1 kg) and is 10 in. long, 5 in. wide, and 3 in. high (≈25, 13, and 7.5 cm, respectively) in its storage configuration. This handheld device produces one liter of medical-grade water in 21 minutes. Total production capacity for this innovation is expected to be in the hundreds of liters. The device contains one battery powered electric mini-pump. Alternatively, a manually powered pump can be attached and used. Drinking water enters the device from a source water bag, flows through two filters, and final sterile production water exits into a sealed, medical-grade collection bag. The collection bag contains pre-placed crystalline salts to mix with product water to form isotonic intravenous medical solutions. Alternatively, a hypertonic salt solution can be injected into a filled bag. The filled collection bag is detached from the device and is ready for use or storage. This device currently contains one collection bag, but a manifold of several pre-attached bags or replacement of single collection bags under sterile needle technique is possible for the production of multiple liters. The entire system will be flushed, sealed, and radiation-sterilized. Operation of the device is easy and requires minimal training. Drinking water is placed into the collection bag. Inline stopcock flow valves at the source and collection bags are opened, and the mini-pump is turned on by a switch to begin fluid flow. When the collection bag is completely filled with the medical- grade water, the pump can be turned off. The pump is designed so it cannot pump air, and overfilling of the collection bag with fluid is avoided by placing an equal amount of water in the source bag. Backflow is avoided by inline check valves. The filled collection bag is disconnected from its tubing and is ready for use. The source bag can be refilled for production of multiple liters, or the source bag can be replaced with an input tube that can be placed in a larger potable water source if the device is attended. The device functions in all orientations independent of any gravity fields. In addition to creating IV fluids, the device produces medical-grade water, which can be used for mixing with medications for injection, reconstituting freeze-dried blood products for injection, or for wound hydration or irrigation. Potential worldwide use is expected with medical activities in environments that have limited resources, storage, or resupply such as in military field operations, humanitarian relief efforts, submarines, commercial cruise ships, etc.

Technology Portfolio System↗

Containment strategy for subsurface H 2 storage based on time-dependent soft solids

Here, we propose an innovative containment strategy based on time-dependent soft solids, namely 2 wt% Laponite suspensions, to reinforce natural subsurface seals and engineer flow barriers, with an eye toward making H 2 subsurface storage scalable and geographically agnostic. This suspension can be injected at its initial low viscosity and elasticity into a porous medium, allowing for easy pumping and targeted delivery. Once inside the target zone, it matures into a soft solid with much higher viscosity and elasticity, acting as a potential flow barrier. We discuss the rheological properties of the suspensions and demonstrate that hydrogen does not adversely affect their microstructure, but rather increases the suspensions’ viscosity and elasticity. Moreover, the suspensions enhance the rock samples’ compressive strength, while hydrogen exposure increases their stiffness and ductility. The ability of rock samples saturated with the suspensions to contain higher injected gas pressures is enhanced by aging at higher temperatures.

08 HYDROGEN↗

Solar heating and domestic hot water system installed at Kansas City, Fire Stations, Kansas City, Missouri

The solar system was designed to provide 47 percent of the space heating, 8,800 square feet area and 75 percent of the domestic hot water (DHW) load. The solar system consists of 2,808 square feet of Solaron, model 2001, air, flat plate collector subsystem, a concrete box storage subsystem which contains 1,428 cubic feet of 0.5 inch diameter pebbles weighing 71.5 tons, a DHW preheat tank, blowers, pumps, heat exchangers, air ducting, controls and associated plumbing. Two 120 gallon electric DHW heaters supply domestic hot water which is preheated by the solar system. Auxiliary space heating is provided by three electric heat pumps with electric resistance heaters and four 30 kilowatt electric unit heaters. There are six modes of system operation.

Source record↗

Solar-energy-system performance evaluation: Honeywell OTS 44, Ocmulgee, Georgia

The operation and technical performance of the solar operational test site (OTS 44) are described, based on data collected between April, 1981 and August, 1981. The following topics are discussed: system description, performance assessment, operating energy, energy savings, system maintenance, and conclusions. The solar energy system at OTS 44 is a hydronic heating and cooling system consisting of 5040 square feet of liquid cooled flat plate collectors; a 4000 gallon thermal storage tank; one 25 ton capacity organic Rankine cycle engine assisted water chillers; a forced draft cooling tower; and associated piping, pumps, valves, controls and heat rejection equipment. The solar system has eight basic modes of operation and several combination modes for providing space conditioning and hot water to the building. Data monitored during the 4 months of the operational test period found that the solar system collected 285 MMBtu of thermal energy of the total incident solar energy of 1040 MMBtu and provided 210 MMBtu for cooling and 10 MMBtu for heating and hot water. The net electrical energy saving due to the solar system was approximately 2600 kWh(e), and fossil energy saving was about 20 million Btu (MMBtu).

Mathur, A. K.↗

“Max-tech FHR”: What is the maximum technically achievable water delivery capacity from a single 120 V plug?

Electrifying water heating will require affordable, direct drop-in replacements for existing gas water heaters that meet consumer expectations for hot water delivery. For many replacement scenarios, affordability requires a replacement option with like-for-like physical product dimensions, and existing consumer expectations presume a large delivery capacity from a small water heater. This work explores the technical potential for hot water delivery capacity for a heat pump water heater (HPWH) powered from a common 120 V plug. Delivery capability in this work is quantified by two metrics: the First Hour Rating (FHR) defined in the Code of Federal Regulations, and a real-world draw profile that resulted in hot water runout during field studies of 120 V HPWHs. The work focuses on the common “tall-and-slim” gas water heater product category, with external product dimensions of 20 inch diameter and 60 inch height. Using a simulation model in DOE/ORNL Heat Pump Design Model, validated by experimental baseline testing of a commercially available 120 V HPWH model, several measures were evaluated to maximize the delivery capacity of a 120 V HPWH. The 120 V HPWH was constrained by 1) external product dimensions of 20 in diameter and 60 inch height, 2) electrical power of 1.5 kW (85% of the available power from a dedicated 120 V, 15 A circuit), and 3) commercially-available components. The measures implemented included a large compressor, a pumped loop with plate heat exchanger to maximize tank stratification, enlarged heat exchangers, and relatively thin insulation to maximize the water storage volume.

Gluesenkamp, Kyle↗

Design Considerations for Phase Change Material-Incorporated Heat Exchangers in Water Heating

In recent years, the buildings sector has seen major pushes towards decarbonization through innovations that promote deep electrification. 20% of an average household's energy use comes from water heating, and in the US, over half of all households still use gas water heaters. Of those that use electricity for water heating, the majority use resistive elements rather than heat pump water heaters (HPWHs), the latter of which use 60-70% less energy than the former. However, HPWHs tend to have larger dimensions, preventing current 50-80-gallon tanks on the market from fitting into smaller utility closets sized for 30-40 gallons, such as those found in manufactured housing. Additionally, these smaller HPWHs tend to underperform relative to their larger counterparts. One solution that addresses both space and performance concerns is thermal energy storage, and in particular, phase change materials (PCMs). This study outlines the design process used to produce novel PCM heat exchangers for use in small-volume HPWH tanks, including the identification of design constraints and performance targets relevant to real-world applications. To ensure optimal PCM utilization and tank storage capacity, this works seeks to co-maximize surface area and PCM volume; therefore, this research targets triply periodic minimal surface (TPMS) lattices, which boast enhanced heat transfer capabilities compared to traditional heat exchanger geometries. Starting with a suite of TPMS lattices, we demonstrate a systematic approach for narrowing down feasible designs that comply with identified constraints while meeting PCM performance objectives. Our current results indicate that tuning lattice properties can effectively produce geometries that provide enough energy storage to achieve a 50-gallon capacity out of a 40-gallon HPWH, even when placing the PCM heat exchanger inside the tank. Additionally, we demonstrate successful fabrication of lattices with these tuned properties.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Liquid hydrogen storage system for heavy duty trucks: Configuration, performance, cost, and safety

In this work, we investigate the potential of liquid hydrogen storage (LH 2 ) on-board Class-8 heavy duty trucks to resolve many of the range, weight, volume, refueling time and cost issues associated with 350 or 700-bar compressed H 2 storage in Type-3 or Type-4 composite tanks. We present and discuss conceptual storage system configurations capable of supplying H 2 to fuel cells at 5-bar with or without on-board LH 2 pumps. Structural aspects of storing LH 2 in double walled, vacuum insulated, and low-pressure Type-1 tanks are investigated. Structural materials and insulation methods are discussed for service at cryogenic temperatures and mitigation of heat leak to prevent LH 2 boiloff. Failure modes of the liner and shell are identified and analyzed using the regulatory codes and detailed finite element (FE) methods. The conceptual systems are subjected to a Failure modes and effects analysis (FMEA) and a safety, codes, and standards (SCS) review to rank failures and identify safety gaps. The results indicate that the conceptual systems can reach 19.6% usable gravimetric capacity, 40.9 g-H 2 /L usable volumetric capacity and $174-183/kg-H 2 cost (2016 USD) when manufactured 100,000 systems annually.

08 HYDROGEN↗

Cost and size estimates for an electrochemical bulk energy storage concept

Preliminary capital cost and size estimates were made for a titanium trichloride, titanium tetrachloride, ferric chloride, ferrous chloride redox-flow-cell electric power system. On the basis of these preliminary estimates plus other important considerations, this electrochemical system emerged as having great promise as a bulk energy storage system for power load leveling. The size of this system is less than two per cent of that of a comparable pumped hydroelectric plant. The estimated capital cost of a 10 MW, 60- and 85-MWh redox-flow system compared well with that of competing systems.

Warshay, M.↗

Cost and size estimates for an electrochemical bulk energy storage concept

Preliminary capital cost and size estimates were made for an electrochemical bulk energy storage concept. The electrochemical system considered was an electrically rechargeable flow cell with a redox couple. On the basis of preliminary capital cost estimates, size estimates, and several other important considerations, the redox-flow-cell system emerges as having great promise as a bulk energy storage system for power load leveling. The size of this system would be less than 2 percent of that of a comparable pumped hydroelectric plant. The capital cost of a 10-megawatt, 60- and 85-megawatt-hour redox system is estimated to be $190 to $330 per kilowatt. The other important features of the redox system contributing to its load leveling application are its low adverse environmental impact, its high efficiency, its apparent absence of electrochemically-related cycle life limitations, and its fast response.

Warshay, M.↗

Design description of the Schuchuli Village photovoltaic power system

A stand alone photovoltaic (PV) power system for the village of Schuchuli (Gunsight), Arizona, on the Papago Indian Reservation is a limited energy, all 120 V (d.c.) system to which loads cannot be arbitrarily added and consists of a 3.5 kW (peak) PV array, 2380 ampere-hours of battery storage, an electrical equipment building, a 120 V (d.c.) electrical distribution network, and equipment and automatic controls to provide control power for pumping water into an existing water system; operating 15 refrigerators, a clothes washing machine, a sewing machine, and lights for each of the homes and communal buildings. A solar hot water heater supplies hot water for the washing machine and communal laundry. Automatic control systems provide voltage control by limiting the number of PV strings supplying power during system operation and battery charging, and load management for operating high priority at the expense of low priority loads as the main battery becomes depleted.

Ratajczak, A. F.↗

Pump-Fed Versus Pressure-Fed Propulsion

Pumping system has lower mass. Equations worked out to compare masses of pump and pressure-fed bipropellant propulsion systems. Equations developed specifically for interplanetary spacecraft but technique adaptable to advanced automative energy-storage techniques.

Estey, P. N.↗

System for energy harvesting and/or generation, storage, and delivery

A device and method for harvesting, generating, storing, and delivering energy to a load, particularly for remote or inaccessible applications. The device preferably comprises one or more energy sources, at least one supercapacitor, at least one rechargeable battery, and a controller. The charging of the energy storage devices and the delivery of power to the load is preferably dynamically varied to maximize efficiency. A low power consumption charge pump circuit is preferably employed to collect power from low power energy sources while also enabling the delivery of higher voltage power to the load. The charging voltage is preferably programmable, enabling one device to be used for a wide range of specific applications.

Trainor, John T.↗

System for energy harvesting and/or generation, storage, and delivery

A device and method for harvesting, generating, storing, and delivering energy to a load, particularly for remote or inaccessible applications. The device preferably comprises one or more energy sources, at least one supercapacitor, at least one rechargeable battery, and a controller. The charging of the energy storage devices and the delivery of power to the load is preferably dynamically varied to maximize efficiency. A low power consumption charge pump circuit is preferably employed to collect power from low power energy sources while also enabling the delivery of higher voltage power to the load. The charging voltage is preferably programmable, enabling one device to be used for a wide range of specific applications.

Trainor, John T.↗

Radiation energy conversion in space; Conference, 3rd, NASA Ames Research Center, Moffett Field, Calif., January 26-28, 1978, Technical Papers

Concepts for space-based conversion of space radiation energy into useful energy for man's needs are developed and supported by studies of costs, material and size requirements, efficiency, and available technology. Besides the more studied solar power satellite system using microwave transmission, a number of alternative space energy concepts are considered. Topics covered include orbiting mirrors for terrestrial energy supply, energy conversion at a lunar polar site, ultralightweight structures for space power, radiatively sustained cesium plasmas for solar electric conversion, solar pumped CW CO2 laser, superelastic laser energy conversion, laser-enhanced dynamics in molecular rate processes, and electron beams in space for energy storage.

Billman, K. W.↗

Hyperfiltration wash water recovery subsystem - Design and test results

The Hyperfiltration Wash Water Recovery (HWWR) subsystem, designed to offer low-power high-volume wash water purification for extended mission spacecraft, is discussed in terms of preprototype design and configuration. Heated wash water collected from the shower, hand wash, and laundry flows into a temperature-controlled (374 K) waste storage tank. Two parallel 25 micron absolute filters at the tank outlet remove large particles from the feed stream. A positive displacement feed pump delivers wash water to the hyperfiltration module at a constant flow rate of 0.20 lpm with discharge pressure variations from 4181-7239 Kpa. The hyperfiltration membrane module is a single-pass design including 36 porous stainless steel tubes, and is designed to provide an approximate water recovery rate of 90 percent. Permeate and brine water flows are monitored by flow meters, and removal of urea and ammonia is achieved by adding 15 percent NaOCl solution to the permeate fluid stream. An alternate module design using two diameters of tubing (allowing a smaller pressure drop and a larger membrane area) gave a superior predicted performance over the first module with larger tubing throughout.

Reysa, R. P.↗

Efficiency of Nd laser materials with laser diode pumping

For pulsed laser-diode-pumped lasers, where efficiency is the most important issue, the choice of the Nd laser material makes a significant difference. The absorption efficiency, storage efficiency, and extraction efficiency for Nd:YAG, Nd:YLF, Nd:GSGG, Nd:BEL, Nd:YVO4, and Nd:glass are calculated. The materials are then compared under the assumption of equal quantum efficiency and damage threshold. Nd:YLF is found to be the best candidate for the application discussed here.

Barnes, Norman P.↗

Microgravity Transport Phenomena Experiment (MTPE) Overview

The Microgravity Transport Phenomena Experiment (MTPE) is a fluids experiment supported by the Fundamentals in Biotechnology program in association with the Human Exploration and Development of Space (BEDS) initiative. The MTP Experiment will investigate fluid transport phenomena both in ground based experiments and in the microgravity environment. Many fluid transport processes are affected by gravity. Osmotic flux kinetics in planar membrane systems have been shown to be influenced by gravimetric orientation, either through convective mixing caused by unstably stratified fluid layers, or through a stable fluid boundary layer structure that forms in association with the membrane. Coupled transport phenomena also show gravity related effects. Coefficients associated with coupled transport processes are defined in terms of a steady state condition. Buoyancy (gravity) driven convection interferes with the attainment of steady state, and the measurement of coupled processes. The MTP Experiment measures the kinetics of molecular migration that occurs in fluids, in response to the application of various driving potentials. Three separate driving potentials may be applied to the MTP Experiment fluids, either singly or in combination. The driving potentials include chemical potential, thermal potential, and electrical potential. Two separate fluid arrangements are used to study membrane mediated and bulk fluid transport phenomena. Transport processes of interest in membrane mediated systems include diffusion, osmosis, and streaming potential. Bulk fluid processes of interest include coupled phenomena such as the Soret Effect, Dufour Effect, Donnan Effect, and thermal diffusion potential. MTP Experiments are performed in the Microgravity Transport Apparatus (MTA), an instrument that has been developed specifically for precision measurement of transport processes. Experiment fluids are contained within the MTA fluid cells, designed to create a one dimensional flow geometry of constant cross sectional area, and to facilitate fluid filling and draining operations in microgravity. The fluid cells may be used singly for bulk solutions, or in a Stokes diaphragm configuration to investigate membrane mediated phenomena. Thermal and electrical driving potentials are applied to the experiment fluids through boundary plates located at the ends of the fluid cells. In the ground based instrument, two constant temperature baths circulate through reservoirs adjacent to the boundary plates, and establish the thermal environment within the fluid cells. The boundary plates also serve as electrodes for measurement and application of electrical potentials. The Fluid Manipulation System associated with the MTA is a computer controlled system that enables storage and transfer of experiment fluids during on orbit operations. The system is used to automatically initiate experiments and manipulate fluids by orchestrating pump and valve operations through scripted sequences. Unique technologies are incorporated in the MTA for measurement of fluid properties. Volumetric Flow Sensors have been developed for precision measurement of total fluid volume contained within the fluid cells over time. This data is most useful for measuring the kinetics of osmosis, where fluid is transported from one fluid cell to another through a semipermeable membrane. The MicroSensor Array has been designed to perform in situ measurement of several important fluid parameters, providing simultaneous measurement of solution composition at multiple locations within the experiment fluids. Micromachined sensors and interface electronics have been developed to measure temperature, electrical conductivity, pH, cation activity, and anion activity. The Profile Refractometer uses a laser optical system to directly image the fluid Index of Refraction profile that exists along the MTA fluid cell axis. A video system acquires images of the RI profile over time, and records the transport kinetics that occur upon application of chemical, thermal, or electrical driving potentials. Image processing algorithms have been developed to analyze the refractometer images on a pixel by pixel basis, calibrating and scaling the measured Index of Refraction profile to correlated solution properties of interest such as density, concentration, and temperature. Additional software has been developed to compile the processed images into a three dimensional matrix that contains fluid composition data as a function of experiment time and position in the fluid cell. These data are combined with data from the other sensor systems, and analyzed in the context of transport coefficients associated with the various transport phenomena. Analysis protocols have been developed to measure the transient kinetics, and steady state distribution of fluid components that occur in response to the applied driving potentials. The results are expressed in terms of effective transport coefficients. Experiments have been performed using a variety of solutes, and results generated are that are in agreement with published transport coefficient values.

Mason, Larry W.↗