10 Micron Search for Cool Companions of Nearby Stars
We present 10 micron broadband images of the nearby stars Gleise 15, 71, 628, 699, 725A 725B, 729, and 820A from an experiment designed to detect cool companions.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
We present 10 micron broadband images of the nearby stars Gleise 15, 71, 628, 699, 725A 725B, 729, and 820A from an experiment designed to detect cool companions.
The Heat Pipe-cooled Microreactor (HPM) is one of the micro nuclear reactor designs under active study at the U.S. Idaho National Laboratory. Among the major concerns of HPM research is to understand the startup behavior of the heat pipe-cooled system associated with the startup of the liquid-metal heat pipes initialing from frozen state. The startup of liquid-metal heat pipes typically involves a number of nonlinear mass and heat transport processes including the phase change from solid to liquid and vapor. Hence, it is still a huge challenge to simulate the liquid-metal heat pipe startup using conventional CFD methods and software. The major difficulties of numerical CFD modeling come from the phase-change process, multiphase interaction, microporous wick flow, and compressible gas dynamics that occur during startup of the liquid-metal heat pipes. This paper proposes a simplified conduction-based method to provide practical insights into the entire startup process of the liquid-metal heat pipes while mitigating the challenges of addressing all the complex physics. We discuss the theoretical basis and modeling assumptions to analyze the liquid-metal heat pipe startup from frozen state based solely on heat-conduction equations. Then, the proposed model is implemented into the commercial CFD software to verify the model performance. The model prediction results are discussed via the comparison with the experimental data obtained from sodium heat-pipe startup experiments.
This paper discusses the current status of a fluorine-hydrazine rocket engine development program. Incorporation of a thin rhenium inner liner successfully eliminated corrosion of the carbon/carbon composite thrust chamber wall experienced during a previous test program. The results of hot-fire tests utilizing reworked and new injectors which provide increased fuel film cooling showed that thrust chamber head-end temperatures could be maintained at an acceptable level. As expected, the accompanying specific impulse performance loss requires optimizing the amount of film cooling to minimize the loss. The efforts to refine the rhenium liner vapor deposition process culminated in a carbon/carbon composite thrust chamber total test duration of 1008 seconds. Tasks presently in process include: (1) fabrication of two carbon/carbon composite thrust chambers incorporating 60:1 expansion ratio nozzles; (2) injector tests to optimize performance and cooling; (3) additional refinements to the rhenium lining process; and (4) fabrication and test of a freestanding rhenium thrust chamber.
Open loop cooling towers play a pivotal role in rejecting heat for chilled water systems serving industrial processes, heating, ventilation, and air conditioning loads. Exposure to outside conditions can present certain operating challenges to system performance including scaling, corrosion, and biological growth. These issues are mitigated through the use of effective cooling tower water filtration and treatment systems to reduce contaminants—along with other total suspended solids (TSS) and total dissolved solids (TDS)—in the system. The U.S. Department of Energy’s Industrial Efficiency and Decarbonization Office is interested in an electrochemical-based filtration system with the ability to remove TSS particulate down to 1 micron. The removal of finer particulates reduces the need for blowdown and, in turn, makeup water use and chemical treatment in the cooling tower. Additionally, the removal process can reduce fouling at the condensers, resulting in better heat exchange and energy savings. Two Industrial Technology Validation program projects validated the electrochemical water filtration system at the Toyota Motor Manufacturing, Mississippi plant in Blue Springs, Mississippi, and the Nissan Canton Vehicle Assembly Plant in Canton, Mississippi. Researchers found that installation of both systems resulted in water and chemical treatment savings with minimal impact on energy use.
The Cryogenic Carbon Capture™ (CCC) process significantly decreases cost and energy demands for CO 2 separation and pressurization to 150 bar compared to alternatives. The process is a post-combustion technology that cools CO 2 -laden flue gas to desublimation temperatures (-100 to -135 °C), separates solid CO 2 —that forms from the flue gas—from the light gases, uses the cold products to cool incoming gases in a recuperative heat exchanger, compresses the solid/liquid CO 2 to final pressures (100–200 bar), and delivers a compressed CO 2 stream separated from an atmospheric pressure light-gas stream. The overall energy and economic costs are about 30-50% lower than most competing processes that involve air separation units (ASUs), solvents, or similar technologies. In addition, the CCC process enjoys several ancillary benefits, including (a) it is a minimally invasive Bolton technology, (b) it provides highly efficient removal of most pollutants (Hg, SOx, NO 2 , HCl, etc.), and (c) possible energy storage capacity. This report outlines the process details and economic and energy comparisons relative to other well-documented alternatives. This paper presents the results of a detailed techno-economic comparison of CCC with amine-based systems. The comparison uses identical financial and economic assumptions similar process assumptions as the detailed analyses published by US DOE in the greenfield analysis. Specifically, the comparison assumes power plants that produce the same net output, one equipped with and a second without carbon capture. Separately, the paper compares similar analyses for retrofitting existing systems using typical plant characteristics in the US (initial capital costs have been paid, high plant utilization), though there are no DOE estimates available for direct comparison. Financial and technical assumptions for all comparisons are maintained as close to the DOE reference studies as possible. The results demonstrate about 30-50% lower costs and energy demands for capture from greenfield coal plants. Natural gas plants produce substantially lower CO 2 concentrations which makes the cost of capturing a ton of CO 2 at the same capture rate as the coal plant higher for all processes while the cost of CO 2 capture per unit of power generation is lower. However, CCC maintains about the same absolute energy and cost advantages for NG as for coal compared to amine systems. Finally, the costs of retrofitting a station are compared to those of building a new station with and without capture. The retrofit costs are comparable to (slightly lower than) new plant costs without capture. In all cases operating and capital cost comparisons show that the CCC process can be retrofitted to a variety of plants to cost effectively reduce CO 2 emissions. Further process integration into the upstream processes and unique process features like water recovery, and integrated energy storage bring the effective cost of carbon capture using the CCC process down further and increase its advantages over alternatives. This technoeconomic analysis shows that the CCC process has the potential to the be lowest cost carbon capture technology under development today.
This data and code package supports the analysis presented in “Beyond Surface Cooling: Comprehensive Field Assessment of Reflective Pavement Thermal Performance in Phoenix, Arizona” and provides fully reproducible workflows for evaluating the thermal performance of cool pavement treatments in a hot urban environment. The dataset integrates multi-modal field measurements collected across residential and nonresidential settings, including mobile air temperature traverses, stationary air temperature monitoring, residential mean radiant temperature (MRT) measurements, subsurface temperature profiles, and controlled testbed observations. The data package contains raw and processed datasets in comma-separated value (CSV) format, accompanying metadata files describing site characteristics and measurement protocols, and R scripts (.R files) used for data cleaning, time synchronization, spatial and temporal matching, quality control filtering, statistical comparison, and figure generation. All analyses were conducted using R (version ≥ 4.2.0) with commonly available packages (e.g., tidyverse, lubridate, data.table, ggplot2). No proprietary software is required to reproduce results. Field campaigns were designed to quantify the effects of high-reflectance pavement coatings on surface temperature, near-surface air temperature, subsurface heat propagation, and radiative heat exposure. Temporal alignment procedures include standardized timestamp conversion and nearest-neighbor matching of high-frequency sensor measurements to stop-based metadata within defined tolerance windows to ensure comparability across instruments. The workflows generate summary statistics, treatment–control contrasts, depth-dependent thermal gradients, and time-series visualizations used in the associated publication. By integrating mobile, stationary, radiative, and subsurface measurements within a unified and transparent processing framework, this package enables comprehensive evaluation of cool pavement performance across multiple thermal exposure pathways and supports reuse in future urban heat mitigation and climate resilience studies.
The industries examined in this report primarily rely on moderate-temperature heat provided by gas- or coal-fired boilers and combined heat and power (CHP) plants, delivered through standard process steam systems. High-temperature energy demands are often industry-specific and typically exceed the capabilities of high-temperature gas-cooled reactors (HTGRs). While it is technically feasible to replace process steam from fossil-based heat sources with nuclear energy, certain industries, such as methanol production and pulp and paper, face technoeconomic challenges in integrating nuclear energy without major changes or a technological shift. This is mainly due to the limited external energy demand remaining after the use of internal byproducts, waste heat recovery, and simple efficiency improvements. Achieving full decarbonization of these processes with nuclear energy would require significant technological advancements, involving experimental technology and substantial investments, making widespread adoption in existing industrial plants unlikely in the near term. This study reviews TES options in the context of enabling a flexible CHP supply while maintaining a steady nuclear heat input. Heat storage systems that interface between the reactor primary fluid and the CHP system offer superior performance and flexibility. Specifically, steam extraction downstream of the reheater with a two-tank molten-salt TES appears as the best solution regarding thermodynamic system benefits and system drawbacks. Using selected system configurations, a conceptual design of an industrial energy park was developed for industries with varying energy demands, such as steel production plants utilizing electric arc furnaces (EAFs) and chemical plants, as well as for those with constant energy demands, like petroleum refineries. This design highlights the capabilities of TES and explores its potential business cases. The study also conceptually develops the potential for integrating additional energy sources with nuclear systems through the implementation of TES. The potential of the HTGR-TES-CHP system was also evaluated considering key uncertainties such as industrial demand profiles, external grid access availability, and eligible tax credit levels, using the Holistic Energy Resource Optimization Network. Sensitivity of net present value to these uncertainties was analyzed to determine the optimal number of nuclear reactors (and CHP systems) and the suitable TES capacity. The results were interpreted from a decision-maker’s perspective, focusing on three key areas: deployment strategy (oversized units vs. undersized units with TES support), industrial process characteristics (thermal-intensive single profiles vs. electricity-intensive combined profiles), and operational goals (maximizing profits vs. minimizing natural gas (NG) consumption or external grid dependence). The optimization results indicate that the HTGR-TES-CHP system significantly reduces reliance on NG boilers for individual industrial processes by 9-60% (in NG capacity factor), with an average reduction of 38%, compared to standalone NG boiler operation case (Business As Usual [BAU]). For combined industrial processes, the reduction ranges from 37-77%, with an average of 60%. Additionally, the system greatly reduces dependence on external grids. In meeting industrial electrical demands, a 33-100% self-sufficient internal electricity supply is achieved for single industrial process, with an average of 74%, compared to the BAU scenario, where 100% of electricity is imported. For combined processes, 35-100% of internal electricity demands are met by the reactor, with an average of 73%. At last, the relative NG price levels at which the proposed HTGR-TES-CHP system can cost-effectively enter the market currently dominated by existing NG boilers were estimated. For a moderate HTGR CAPEX level ($\$$2500/kWth, $\$$6329/kWe), the analysis suggests that NG prices must be 2.5 to 7 times higher than HTGR variable operating and maintenance costs for single industrial process, and 5.5 to 9.5 times higher for a combined process scenario. Tax credit modeling shows that the Investment Tax Credit significantly reduces the price threshold needed to break even, making the system competitive with NG boilers in certain cases.
We report particulate nuclear fallout is the radioactive byproduct of a nuclear event formed by the mixture of proximate environmental materials with vaporized bomb debris. The fallout debris can be transported into the atmosphere during cloud rise, raining out locally and dispersing globally constituting a radiation hazard and contributing to the distribution of anthropogenic radionuclides in the environment. Questions remain on how entrainment of environmental material in the fireball affects fallout formation processes and radionuclide incorporation and distribution during cooling. To inform the characterization of fallout including the development of fallout size distributions and how radionuclides are incorporated into fallout debris where entrainment plays a role, we analyzed an archived historic US air-filter collected by aircraft in the aftermath of ground interacting nuclear tests. Particulate fallout collected on the filter was isolated and analyzed using scanning electron microscopy (SEM), transmission electron microscopy (TEM) and NanoSIMS (Secondary Ion Mass Spectrometry) to determine chemistry, structure, morphology, and size of the particles. Results demonstrate that the particles isolated from the filter have spherical shape, display complex internal structures, and are mainly composed of Fe and Si oxides. In these spherical particles, Pu is preferentially associated with Fe-rich composition. The characterization of fallout particulate samples can provide information on nucleation and particle growth from the vapor phase to improve modeling and simulation of fallout hazards.
Integrated SO x and NO x removal technology using a direct contact cooler is a promising alternative for cleaning coal combustion flue gas, especially for pressurized combustion systems. Past investigations of integrated SO x and NO x removal have been limited to low-temperature processes, where the flue gas has been cooled upstream of the removal unit, and the moisture in the flue gas has been condensed out. Here this work presents a novel design that recovers the flue gas heat while simultaneously removing SO x and NO x in a single reactive-absorption column – direct contact cooler. A validated model was used to evaluate different direct contact cooler designs. Modeling results suggested that a counter-current column with a single water inlet can scrub 83% of the NO x and 96.5% of the SO x in 115 s, while an optimized design with multiple water inlets enhances the scrubbing of NO x by 9 percentage points and SO x by 3.5 percentage points, due to a 34% increase in residence time. It is also observed that the liquid-phase reaction between absorbed SO x and NO x plays a significant role in the removal of SO 2 from the flue gas for high-temperature scrubbing compared with low-temperature scrubbing. The design reinforces the potential of high-temperature SO x -NO x removal and heat recovery and suggests a means of reducing capital costs for such columns.
The dehumidification of air is a highly energy-intensive process, typically requiring vapor compression systems to cool the air significantly below its dew point temperature. Here, this study numerically investigates air dehumidification achieved by electrostatic and dielectrophoresis forces in a converging duct and centrifugal principles in cyclone separators. An electrospray was employed to energize water droplets, which then captured water vapor via dielectrophoresis. A novelty of the present study is the inclusion of a cyclone separator positioned downstream of the electrospray. This combination increased the dehumidification efficiency and controlled the flow of the condensate. By integrating electrospray technology and applying an electric field, this study examines the impact of particle separation efficiency, pressure drops, and cyclone performance on air dehumidification. The control parameters for air dehumidification were investigated. Three cyclones were modelled for airflow rates of 5 cubic feet per minute [cfm] (0.0024 m 3 /s), 38 cfm (0.0179 m 3 /s), and 200 cfm (0.094 m 3 /s). The results indicated air dehumidification was up to 5.7 % under environmental conditions, similar to those used to validate the CFD model. The degree of air dehumidification was primarily influenced by the electric charge acquired by the water droplets, their flight trajectory, and the vorticity intensity within the cyclone. Air dehumidification could increase by up to 13 % by increasing the number of droplets injected into the air stream, the flight time, and the electrical charge. The breakdown electric field strength threshold near the electrospray was a limiting factor for further enhancing dehumidification performance. This study examines the optimization of an electro-assisted dehumidification system that includes cyclone-based droplet separation through numerical analysis. The results provide insights into the design of energy-efficient air treatment technologies.
Hydrogen isotopes retention and desorption during and after discharges in fusion devices are still not well understood due to the complex device conditions and limitations of in-situ diagnostics and measurements. Here, we simulated well-diagnosed recent experiments at the DIII-D facility to benchmark our ITMC-DYN integrated package of modeling deuterium diffusion, retention, and desorption during and after D discharge irradiation. Modeling results were compared with detail experimental data of D desorption fluxes for various irradiation conditions. We predicted the temporal evolution of free and trapped D distribution in tungsten (W) plasma-facing material (PFM). Effects of key parameters namely diffusion coefficient, recombination rate, trapping energies against different defect types, were examined in these simulations. Existing experimental data of these parameters in literature varies significantly which makes it harder to identify key mechanisms and physics responsible for hydrogen isotope retention and desorption. The purpose of this work is to accurately simulate recent well-diagnosed reactor experiments given the uncertainties in such parameters and identify mechanisms responsible for the retention and desorption. We implemented the best identified diffusion, recombination, and trapping parameters in ITMC-DYN package that integrate both various collisional and thermal processes. We predicted, for example, that sample cooling between discharges in DIII-D operations can significantly affect the spatial distribution of trapped D in W under reactor irradiation conditions. Correct prediction of desorption spectra from samples irradiated during 10 DIII-D discharges showed that up to 35% of D can be retained in high binding energy defects such as vacancy clusters or voids.
Tri-structural isotropic (TRISO) fuel particles are a fuel form being considered for potential use in next-generation nuclear reactors (i.e., high-temperature gas-cooled reactors). Though the TRISO fuel manufacturing process has continually advanced in recent years, particle comparisons still reveal statistical variations and uncertainties in terms of geometric configurations and material properties. Given that the physical processes ongoing in TRISO fuel particles during reactor operation are highly correlated with each other, a small degree of uncertainty in one model may lead to significant uncertainty in another. This makes appropriate uncertainty quantification of TRISO fuel particles essential. However, one may wonder about the extent to which the current version of TRISO particles has been optimized, and whether any room remains for further improvements. This paper quantifies TRISO fuel performance model uncertainties that stem from geometric and material data. For this analysis, the BISON code was used, and the Advanced Gas Reactor (AGR)-2 experiment served as a reference case. A total of 10 5 calculations was performed for the uncertainty and optimization analysis, altering the geometric and material data within their uncertainty range. Lastly, the optimization potential of TRISO particles is evaluated from a fuel performance perspective.
Three-dimensional (3D) hierarchical nanoporous Cu (3DHNP-Cu) is synthesized using a combination of direct ink writing (DIW) based 3D printing, thermal sintering, and chemical dealloying of Mn–Cu alloys. Through tuning processing conditions such as ink composition and cooling rate (after sintering), with consideration of Mn loss during sintering, 3DHNP-Cu with fully bicontinuous nanostructures and negligible residual Mn can be produced after dealloying. The 3DHNP-Cu is comprised of structural features that span seven orders of magnitude, where DIW digitally controls macroscale porous features, thermal sintering and degradation of the binding polymer determines microscale porous features, and dealloying gives rise to nanoscale pores.
Hybrid organic−inorganic metal halide perovskites (MHPs) are promising semiconductors for photovoltaics and optoelectronics, but their commercial viability is limited by instability, particularly strain induced by mismatch in coefficients of thermal expansion (CTE) between the perovskite film and substrate. Here, we investigate strain development and relaxation in MHP thin films using in situ bending and Grazing Incidence Wide-Angle X-ray Scattering (GIWAXS). We quantify the film− substrate interfacial mechanical coupling and identify interfacial slippage beyond a critical strain (∼0.4%), with Br-2PACz exhibiting comparatively stronger interfacial mechanical coupling among common interface modifiers. Time-resolved GIWAXS reveals reversible macrostrain during thermal cycling driven by CTE mismatch. Leveraging this behavior, we introduce a prestrain process that induces persistent compressive strain after cooling, with partial relaxation over time. These results provide insight into interfacial mechanical coupling and strain dynamics, offering a framework for strain engineering in perovskite devices.
Transient grating spectroscopy has become a mainstay among metal and semiconductor characterization techniques. Here, we extend the technique toward the shortest achievable time scales by using tabletop high-harmonic generation of attosecond extreme ultraviolet (XUV) pulses that diffract from transient gratings generated with sub-5 fs near-infrared (NIR) pulses. We demonstrate the power of attosecond transient grating spectroscopy (ATGS) by investigating the ultrafast photoexcited dynamics in an Sb semimetal thin film. ATGS provides an element-specific, background-free signal unfettered by spectral congestion, in contrast to transient absorption spectroscopy. With ATGS measurements in Sb polycrystalline thin films, we observe the generation of coherent phonons and investigate the lattice and carrier dynamics. Among the latter processes, we extract carrier thermalization, hot carrier cooling, and electron-hole recombination, which are on the order of 20 fs, 50 fs, and 2 ps time scales, respectively. Furthermore, the simultaneous collection of transient absorption and transient grating data allows us to extract the total complex dielectric constant in the sample dynamics with a single measurement, including the real-valued refractive index, from which we are also able to investigate carrier-phonon interactions and longer-lived phonon dynamics. The outlined experimental technique expands the capabilities of transient grating spectroscopy and attosecond spectroscopies by providing a wealth of information concerning carrier and lattice dynamics with an element-selective technique at the shortest achievable time scales.
Zr–Rh metallic glass has enabled its many applications in vehicle parts, sports equipment and so on due to its outstanding performance in mechanical property, but the knowledge of the microstructure determining the superb mechanical property remains yet insufficient. Here, we develop a deep neural network potential of Zr–Rh system by using machine learning, which breaks the dilemma between the accuracy and efficiency in molecular dynamics simulations, and greatly improves the simulation scale in both space and time. Here, the results show that the structural features obtained from the neural network method are in good agreement with the cases in ab initio molecular dynamics simulations. Furthermore, we build a large model of 5400 atoms to explore the influences of simulated size and cooling rate on the melt-quenching process of Zr 77 Rh 23 . Our study lays a foundation for exploring the complex structures in amorphous Zr 77 Rh 23 , which is of great significance for the design and practical application.
Here we present a formulation for a local cooling function to be employed in the diffuse, hot corona region of 3D GRMHD simulations of accreting black holes. This new cooling function calculates the cooling rate due to inverse Compton scattering by considering the relevant microphysics in each cell in the corona and approximating the radiation energy density and Compton temperature thereby integrating over the thermal seed photon flux from the disk surface. The method either assumes the ion and electron temperatures are equal (1T) or calculates them separately (2T) using an instantaneous equilibrium approach predicated on the actual relevant rate equations (Coulomb and Compton). The method is shown to be consistent with a more detailed ray-tracing calculation where the bulk of the cooling occurs, but is substantially less costly to perform. As an example, we apply these methods to a harm3d simulation of a 10M⊙, non-spinning black hole, accreting at nominally 1% the Eddington value. This new approach leads to radiative efficiency values sime65% above Novikov–Thorne, with a larger fraction of total cooling in the corona as compared to simulations performed using the original target-temperature cooling function. Time-averaged post-processing reveals that the continuum spectral observations predicted from these simulations are qualitatively similar to actual X-ray binary data, especially so for the 1T approach, which yields a harder power-law component (Γ = 2.25) compared to the 2T version (Γ = 2.53).
Heat transfer mechanism for cooling human body in spacecraft cabins and extravehicular pressurized suits