Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “positioning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Autonomous Coupler Alignment Using Position-Based Visual Servoing in a ROS 2 Framework

As robotic arms are becoming increasingly common alongside humans as collaborative robots, their high precision in motion enables tasks to be performed at significantly higher speeds with reduced disruption in the environment. The Fermi National Accelerator Laboratory is exploring this application by incorporating a UR16e from Universal Robots in a cleanroom setting during assembly of couplers to superconducting radio frequency cavities as part of the PIP-II project. The goal of the robotic assembly process is to precisely position the UR16e robot so that the coupler flange, mounted on the robot’s end-effector, is accurately aligned with and pressed against the cavity flange, requiring only final fastening by a lab technician. This thesis builds upon an initial system in which the robotic process was limited to the alignment phase using position-based visual servoing with an eye-in-hand camera to only align the coupler to the cavity with an offset distance. The objective of this thesis is to further advance autonomous robotic assembly by extending the process. To this end, the entire software framework was reconstructed, as the previous development environment posed significant challenges in modifying the software and adapting to hardware changes. The main contributions of this thesis are as follows: (i) a modular and scalable software framework based on ROS~2 was developed to facilitate performance expansion and interchangeability of software and hardware components; (ii) the desired alignment position for position-based visual servoing was parameterized to enable flexible configuration; and (iii) a methodology was developed to close the offset distance between the coupler and cavity utilizing the internal force-torque sensing capability of the UR16e, as visual feedback is not available during the offset-closing phase. The proposed autonomous robotic assembly reduces assembly time and technician involvement, thereby minimizing the risk of airborne particulate contamination, which is essential in the cleanroom setting. Moreover, the ROS~2-based framework provides a foundation for further expansion and continued advancement of robotic automation in Fermilab.

Giffen, Nickolas [Northern Illinois U.]↗

Direction-preserving and Schur-monotonic Semi-separable Approximations of Symmetric Positive Definite Matrices

For a given symmetric positive definite matrix A {element_of} R{sup nxn}, we develop a fast and backward stable algorithm to approximate A by a symmetric positive-definite semi-separable matrix, accurate to any prescribed tolerance. In addition, this algorithm preserves the product, AZ, for a given matrix Z {element_of} R{sup nxd}, where d << n. Our algorithm guarantees the positive-definiteness of the semi-separable matrix by embedding an approximation strategy inside a Cholesky factorization procedure to ensure that the Schur complements during the Cholesky factorization all remain positive definite after approximation. It uses a robust direction-preserving approximation scheme to ensure the preservation of AZ. We present numerical experiments and discuss potential implications of our work.

97 MATHEMATICS AND COMPUTING↗

Time-Resolved Beam Position Measurements for the Scorpius Multipulse Linear Induction Accelerator

Beam position monitors (BPMs) provide time-resolved measurements of the current and centroid position of high-current electron beams in linear induction accelerators (LIAs). One of the types of detectors used in BPMs is the B-dot loop, which generates a signal from the EMF due to the time varying magnetic flux through the loop. If some of the boundaries of the loop are composed of thick metal walls with finite conductivity, the resulting signal must be corrected for the magnetic field diffusion into the metal. The theoretically predicted flux due to diffusion is in remarkable agreement with experimental measurements. Although accurate BPM measurements of beam current require correction of magnetic field diffusion, accurate measurement of beam position requires no correction. In this note, we present a theoretical derivation and the experimental validation of this result.

43 PARTICLE ACCELERATORS↗

Scoping Study of Effects on the Advanced Test Reactor’s Center Flux Trap Due to Various Loadings in the H and Inner A Test Positions

This study determined the effects experienced by the In-Pile Tube, of the Advanced Test Reactor’s center flux trap, due to various loading configurations of the H and Inner A positions. The effects of concern included: the axial profile of the linear heat generation rate of each fuel rodlet, the axial flux shape, and spectrum, in the fuel, and cladding, of each rodlet, and the total fission heating rate of the entire In-Pile Tube. Additionally, the reactivity worth of each configuration, relative to an ATR configuration with water filling all concerning test positions, was determined. The test positions were filled with commonly used test specimens, backup test specimens, and homogeneous substances. The study was performed using the modeling software MCNP6.2.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

IonCCD™ for direct position-sensitive charged-particle detection: from electrons and keV ions to hyperthermal biomolecular ions

A novel charged-particle sensitive, pixel based detector array is described and its usage is demonstrated for a variety of applications, from detection of elemental particles (electrons) to hyper-thermal large biomolecular positive and negative ions including keV light atomic and molecular ions. The array detector is a modified light-sensitive charged coupled device (CCD). The IonCCDTM was engineered for direct charged particle detection by replacing the semi-conductor part of the CCD pixel by a conductor1. In contrast with the CCD, where the semi-conductive pixel is responsible for electron-hole pair formation upon photon bombardment, the IonCCD uses a capacitor coupled to the conductive electrode for direct charge integration. The detector can be operated from atmospheric pressure to high vacuum since no high voltages are needed. The IonCCD, presented in this work is an array of 2126 active pixels with 21 um pixel width and 3 um pixel gap. The detection area is 1.5x51mm2 where 1.5 mm and 51 mm are pixel and detector array length, respectively. The result is a one-dimensional position-sensitive detector with 24 um spatial resolution and 88 % pixel area ratio (PAR). In this work we demonstrate the capabilities and the performance of the detector. For the first time we show the direct detection of 250 eV electrons providing linearity response and detection efficiency of the IonCCD as function of electron beam current. Using positive ions from and electron impact source (E-I), we demonstrate that the detection efficiency of the IonCCD is virtually independent of particle energy [250 eV, 1250 eV], particle impact angle [45o, 90o] and particle flux. By combining the IonCCD with a double focusing sector field of Mattauch-Herzog geometry (M-H), we demonstrate fast acquisition of mass spectra in direct air sniffing mode. A first step towards fast in vivo breath analysis is presented. Detection of hyper-thermal biomolecular ions produced using an electrospray ionization source (ESI) is presented. The IonCCD was used as beam profiler to characterize the beam shape and intensity of 15 eV protonated and deprotonated biomolecular ions at the exit of an RF only collisional quadrupole. We present simultaneous detection of 140 eV doubly protonated biomolecular ions when the IonCCD is combined with the M-H analyzer. The latter, demonstrates the possibility of simultaneous separation and micro-array deposition of biological material using a miniature sector field.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A sweeping positivity-preserving high-order finite difference WENO scheme for Euler equations

We develop a simple, high-order, conservative and robust positivity-preserving sweeping procedure for the density and the nonlinear pressure function in the compressible Euler equations. Using the scaling limiter in Zhang and Shu (J Comput Phys 229:3091–3120, 2010), we obtain a non-trivial extension of the scalar sweeping technique in Liu et al. (J Sci Comput 73:1028–1071, 2017) for the positivity of pressure. The sweeping procedure developed in this paper is a post-processing technique, which can be applied to any concave functions of the conserved variables in hyperbolic conservation law systems. Thus, it has applications beyond the Euler equations. This procedure preserves positivity and conservation of physical quantities without destroying the accuracy of the underlying scheme. The algorithm works for general schemes including finite difference, finite volume and discontinuous Galerkin methods; however, in this paper we focus on finite difference weighted essentially non-oscillatory (WENO) methods. As a result, we provide numerical tests of the fifth-order finite difference WENO scheme to demonstrate the accuracy and robustness of the technique.

Compressible Euler equations↗

Performance tests of large area position-sensitive planar germanium detectors with conventional and amorphous contacts.

Large area position-sensitive planar germanium wafers are increasingly being used for a variety of gamma-ray imaging and tracking tasks. Position sensitivity can be achieved through measuring charge collected on orthogonal strip electrodes, and by digital pulse shape analysis. However, the development of this detector technology has been slow, and criteria to measure improved performance have not been well established. We have studied 93 and 88 mm square segmented detectors of 20 mm thickness made with conventional boron and lithium electrodes, and two 100 mm circular segmented detectors of 14 mm thickness with amorphous germanium contacts. We have compared these detectors with a planar detector of 15 mm thickness. Conventional energy resolution tests of individual strips are insufficient to fully categorize the performance of the position sensitive detectors. We propose some basic tests which can rapidly quantify any segmented detector characteristics, and show potential inadequacies which become important when imaging or tracking is attempted.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Uniformity measurements and new positioning algorithms for wavelength-shifting fiber neutron detectors

Wavelength-shifting (WLS) fiber scintillator detectors were successfully installed at two neutron powder diffractometers at the Spallation Neutron Source (SNS). But, they have the following second-order disadvantages: (i). they cannot have both high efficiency and images free of ghosting (position misassignment) concomitantly; (ii). the apparent detection efficiency and spatial resolution are not uniform. These issues are related to the diffusion of scintillation photons and the fluctuation in the number of photons (quantum noise) collected by photo-multiplier tubes (PMTs). Therefore, to mitigate these two issues, we developed two statistics-based positioning algorithms, i.e., a centroid algorithm (CEA) and a correlation algorithm (CA). Compared with the generally used maximum-photon algorithm (MPA), CEA eliminates the ghosting with only about a 10% loss in detection efficiency, and provides better uniformity in detection efficiency and intrinsic background. CA can effectively eliminate ghosting too, but the loss of efficiency at the group boundaries of PMTs is large. Our results indicate that both algorithms can reduce the influence of quantum noise on the neutron positioning.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A 4 x 4 array module of position-sensitive virtual Frisch-grid CdZnTe detectors for gamma-ray imaging spectrometers

Arrays of position-sensitive virtual Frisch-grid CdZnTe (CZT) detectors offer an economical approach to making high efficiency and high energy resolution gamma cameras for spectroscopy and imaging of radioactive sources. There are many application areas for such instruments including gamma-rays astronomy, medical and industrial imaging, nonproliferation and nuclear safeguards. We present the test results from a 4x4 array module coupled to the front-end ASIC. The array houses 16 detectors made of 6x6x20 mm 3 CZT crystals. Each crystal is encapsulated inside an ultrathin polyester shell and furnished with four 5-mm-wide charge-sensing pads placed near the anode on each side of the detector. The pad’s signals are used to measure X-Y coordinates while the cathode signals give the interaction depths (Z coordinates). Combined together the signals provide 3D position information of the interaction points which can be used to correct the detector response non-uniformity. This allows developers to use standard grade (unselected) CZT crystals while retaining high spectroscopic performance comparable with that of the H3D pixelated detectors. The array’s design provides flexibility to replace individual detectors and extend their sizes, potentially increasing upwards of 4 cm in height. We started development of position-sensitive VFG detectors several years ago and today this technology has reached a high-maturity level and is ready to use in practical applications.

3D charge-loss correction↗

Performance of 8 × 8 × 32 and 10 × 10 × 32 mm 3 CdZnTe position-sensitive virtual Frisch-grid detectors for high-energy gamma ray cameras

CdZnTe (CZT) crystals with thicknesses up to 20 mm and diameters up to 75 mm have become available from Redlen Technologies, Inc. for making large-volume gamma-ray detectors. The modified growth and optimized annealing conditions allowed Redlen to minimize the dark current and improve the uniformity of CZT crystals. Two detector designs, pixelated (H3D) and position-sensitive virtual Frisch-grid (VFG), have greatly benefitted from the availability of such big crystals. Encouraging results from testing of 40×40×15 mm 3 pixelated detectors were recently reported by the University of Michigan. In this work, we evaluated the spectroscopic properties of 8×8×32 and 10×10×32 mm 3 crystals configured as position-sensitive VFG detectors. Both digitized waveforms and an analog ASIC were used to read and process the signals from the detectors and test their spectral- and spatial-resolution. The VFG design provides the flexibility to scale-up the dimensions of the detectors for the desired efficiency, while the position information allows for correcting the detectors' response non-uniformity caused by crystal defects and devices geometry, thereby reducing the instrument cost and making them more feasible for emerging applications in gamma-ray astronomy, nonproliferation, portal screening and nuclear safeguards, where large detector arrays are often required.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tuning colloidal quantum dot band edge positions through solution-phase surface chemistry modification

Band edge positions of semiconductors determine their functionality in many optoelectronic applications such as photovoltaics, photoelectrochemical cells and light emitting diodes. Here we show that band edge positions of lead sulfide (PbS) colloidal semiconductor nanocrystals, specifically quantum dots (QDs), can be tuned over 2.0 eV through surface chemistry modification. We achieved this remarkable control through the development of simple, robust and scalable solution-phase ligand exchange methods, which completely replace native ligands with functionalized cinnamate ligands, allowing for well-defined, highly tunable chemical systems. By combining experiments and ab initio simulations, we establish clear relationships between QD surface chemistry and the band edge positions of ligand/QD hybrid systems. We find that in addition to ligand dipole, inter-QD ligand shell inter-digitization contributes to the band edge shifts. As a result, we expect that our established relationships and principles can help guide future optimization of functional organic/inorganic hybrid nanostructures for diverse optoelectronic applications.

36 MATERIALS SCIENCE↗

Development of Position-Sensitive Magnetic Calorimeter X-ray Detectors

We are developing arrays of position-sensitive magnetic calorimeter (PoSM) X-ray detectors for future astronomy missions. The PoSM consists of multiple absorbers thermally coupled to one magnetic sensor. Each absorber element has a different thermal coupling to the sensor. This results in a distribution of different pulse shapes and enables position discrimination between the absorber elements. PoSMs are motivated by the desire to achieve the largest possible focal plane area with the fewest number of readout channels without compromising on spatial sampling. Optimizing the performance of PoSMs requires careful design of key parameters such as the thermal conductances between the absorbers, magnetic sensor and the heat sink, as well as the absorber heat capacities. We report on the first experimental results from four-absorber PoSMs, each absorber consisting of a two layer composite of bismuth and gold. The measured energy resolution (FWHM) was less than 5 eV for 6 keV X-rays into all four absorbers. Straightforward position discrimination by means of rise-time is also demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time of flight elastic recoil detection analysis with a position sensitive detector

A position sensitive detection system based on the microchannel plate detector has been constructed and installed at the existing time of flight (TOF) spectrometer in order to perform a kinematic correction and improve the surface time/depth resolution of elastic recoil detection analysis (ERDA) system. The position resolution of the detector has been tested for different types of ions and anode voltages. TOF spectra of recoiled O ions from SiO{sub 2} and F from CaF{sub 2} were collected in coincidence with position sensitive detector signal. Kinematic correction of TOF spectra improved surface time/depth resolution by {approx}20% for our system; however even higher improvements could be obtained in larger solid angle TOF-ERDA systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single Crystal Diamond Beam Position Monitors with Radiofrequency Electronic Readout

Over the energy range 5{approx}30 keV a suitably contacted, thin ({approx}100 {mu}m) diamond plate can be operated in situ as a continuous monitor of X-ray beam intensity and position as the diamond absorbs only a small percentage of the incident beam. Single crystal diamond is a completely homogeneous material showing fast (ns), spatially uniform signal response and negligible (<pA) leakage currents. Due to its unsurpassed thermal conductivity, it is the only semiconductor material that can be used in intense synchrotron white beams. We report on tests made at ESRF and DESY using diamond beam position monitors of simple quadrant electrode designs with metal contacts, operated using wideband electronic readout corresponding to the RF accelerator frequency. The instrumentation for these monitors must cover a large range of operating conditions: different beam sizes, fluxes, energies and time structure corresponding to the synchrotron fill patterns. Sophisticated new RF sampling electronics can satisfy most requirements: using a modified Libera Brilliance readout system, we measured the center of gravity position of a 25 {mu}m beam at the DORIS III F4 beam line at a rate of 130 Msample/s with narrowband filtering of a few MHz bandwidth. Digitally averaging the signal further provided a spatial resolution {approx}20 nm.

43 PARTICLE ACCELERATORS↗

Single-shot beam-position monitor for x-ray free electron laser

We have developed an x-ray beam-position monitor for detecting the radiation properties of an x-ray free electron laser (FEL). It is composed of four PIN photodiodes that detect backscattered x-rays from a semitransparent diamond film placed in the beam path. The signal intensities from the photodiodes are used to compute the beam intensity and position. A proof-of-principle experiment at a synchrotron light source revealed that the error in the beam position is reduced to below 7 {mu}m by using a nanocrystal diamond film prepared by plasma-enhanced chemical vapor deposition. Owing to high dose tolerance and transparency of the diamond film, the monitor is suitable for routine diagnostics of extremely intense x-ray pulses from the FEL.

43 PARTICLE ACCELERATORS↗

High speed two-dimensional optical beam position detector

Disclosed is the design of a high speed two-dimensional optical beam position detector which outputs the X and Y displacement and total intensity linearly. The experimental detector measures the displacement from DC to 123 MHz and the intensity of an optical spot in a similar way as a conventional quadrant photodiode detector. The design uses four discrete photodiodes and simple dedicated optics for the position decomposition which enables higher spatial accuracy and faster electronic processing than conventional detectors. Measurements of the frequency response and the spatial sensitivity demonstrate high suitability for atomic force microscopy, scanning probe data storage applications, and wideband wavefront sensing. The operation principle allows for position measurements up to 20 GHz and more in bandwidth.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Position and energy-resolved particle detection using phonon-mediated microwave kinetic inductance detectors

We demonstrate position and energy-resolved phonon-mediated detection of particle interactions in a silicon substrate instrumented with an array of microwave kinetic inductance detectors (MKIDs). The relative magnitude and delay of the signal received in each sensor allow the location of the interaction to be determined with < or approx. 1mm resolution at 30 keV. Using this position information, variations in the detector response with position can be removed, and an energy resolution of {sigma}{sub E} = 0.55 keV at 30 keV was measured. Since MKIDs can be fabricated from a single deposited film and are naturally multiplexed in the frequency domain, this technology can be extended to provide highly pixelized athermal phonon sensors for {approx}1 kg scale detector elements. Such high-resolution, massive particle detectors would be applicable to rare-event searches such as the direct detection of dark matter, neutrinoless double-beta decay, or coherent neutrino-nucleus scattering.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser beam pointing stabilization using analog position-sensitive diodes

Laser wire scanners have been used for ion beam profile and emittance measurements at the Spallation Neutron Source linear accelerator. Due to propagation distances exceeding 100 m, reliable measurements require laser beam stabilization, previously accomplished with a feedback control loop using a digital camera as a position sensor [Hardin et al., Opt. Express 19, 2874 (2011)]. Here, this paper presents an upgraded pointing stabilization system utilizing analog position-sensitive diodes (PSDs) as the position detector, optimized with an optical diffuser. The new system significantly surpasses the previous system by offering an order-of-magnitude improvement in radiation tolerance and a bandwidth limited only by the burst repetition rate of the laser beam. Operating with a 60-Hz burst mode laser, the new system effectively suppresses laser beam drifts up to 30 Hz, compared to the previous system’s 4 Hz limit. In addition, the amplitude of spectral components below 0.1 Hz was reduced by a factor of more than 100, which is over seven times greater than was achieved by the previous system.

Data acquisition↗