Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “plasticity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Plasticity of irradiated materials at the nano and micro-scales

Here, we review here our recent work on plastic deformation in irradiated materials at the nano- and micro-scales, as revealed by Discrete Dislocation Dynamics (DDD) simulations. Two methods of including irradiation effects in the DDD framework are presented. The first directly captures the atomistic interaction mechanisms, while the second can effectively study high-dose irradiation. Computer simulations lead to new understanding of the dynamics of collective dislocation-irradiation defect interactions, as well as the quantitative analysis of the temporal and spatial characteristics associated with plastic instabilities. Based on these insights, theoretical models are developed to predict the critical conditions for dislocation channel formation. A simple probability model is proposed and demonstrated to predict the width of dislocation channels in bulk irradiated materials with good agreement with experimental data. The fundamental understanding of the origins of plastic flow localization in irradiated materials sheds light on the design of future generations of radiation-resistant materials.

36 MATERIALS SCIENCE↗

Economic and environmental feasibility of recycling flexible plastic packaging from single stream collection

As demand for plastic increases, there is an urgent need to ramp up its collection and recycling rate. This study reports results of a pilot study in the United States to recycle flexible plastic packaging (FPP) from single stream curbside collection focusing on both the economic feasibility and carbon footprint. To explore the marketability of recycled FPP, four down-stream market pathways were studied, including roof coverboard, plastic pellets, pallets, and film. In this work, results indicated that (1) the cleaning and pelletizing process at reclaimers contributed the most to the total greenhouse gas (GHG) emissions of recycled FPP products, and (2) the GHG emissions of recycled FPP products in all four pathways are lower than the comparator products. Therefore, using a higher percentage of recycled FPP substituted in a product can result in greater GHG emission reductions. All the recycled FPP products also showed favorable economics compared to their direct competitors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Shear bands in a bulk metallic glass after large plastic deformation

A transmission electron microscopy investigation is conducted to trace shear bands in a Zr{sub 53}Cu{sub 18.7}Ni{sub 12}Al{sub 16.3} bulk metallic glass after experiencing 4% plastic deformation. Shear band initiation, secondary shear band interactions, mature shear band broadening and the interactions of shear bands with shear-induced nanocrystals are captured. Results suggest that the plasticity of the bulk metallic glass is enhanced by complex shear bands and their interactions which accommodate large plastic strain and prevent catastrophic shear band propagation.

36 MATERIALS SCIENCE↗

Upcycling plastic waste into polyhydroxyalkanoates with high carbon conversion via CO 2 plasma-enabled deconstruction

Plastic deconstruction into fermentable intermediates is a key step for microbial bio-upcycling into value-added products. In this study, CO 2 plasma deconstruction was used as an electrified route to convert polyethylene into oxygenated intermediates and liquid (OIL). The resulting OIL was rich in fatty acids, fatty alcohols, and hydrocarbons, making it a suitable feedstock for medium-chain-length polyhydroxyalkanoate (mcl-PHA) production by Pseudomonas putida NRRL B-14688 and Pseudomonas resinovorans NRRL B-2649. Compared with batch fermentation and monocultures, fed-batch co-cultivation markedly improved biomass formation and PHA accumulation, likely due to complementary substrate utilization, particularly hydrocarbon conversion by P. resinovorans. Using virgin polyethylene-derived OIL (Vir-OIL), the co-culture achieved 40.11% mcl-PHA content and about 18% PHA yield based on total OIL fed. More importantly, OIL produced from post-consumer single-use plastic films (PCR-OIL) was directly fermented and well supported the cell growth and PHA accumulation, achieving 38.11% PHA content and about 14.7% PHA yield. Based on emulsified OIL fractions, PHA yields for Vir-OIL and PCR-OIL were comparable (∼28%). PHA granules were extracted from PCR-OIL-grown cells with high recovery (88.25%) and purity (94.8%). Five monomers were identified in the polymer, including 3-hydroxyhexanoate (3HHx), 3-hydroxyoctanoate (3HO), 3-hydroxydecanoate (3HD), 3-hydroxydodecanoate (3HDD), and 3-hydroxytetradecanoate (3HTD), with 3HO (44.28%) and 3HD (40.60%) as the dominant units. The polymer exhibited moderate molecular weight and narrow dispersity (M n = 65.4 kDa, M w = 92.1 kDa, Đ = 1.40) and low crystallinity (T m ≈ 76.6 °C, X c ≈ 15.5%). These characteristics indicate elastomer-like behavior, making the material suitable for flexible applications such as films, coatings, adhesives, and blend modifiers. Overall, this study establishes a CO 2 plasma-assisted route for generating fermentable polyethylene-derived intermediates and demonstrates that fed-batch co-culture fermentation can effectively funnel plastic-derived carbon into mcl-PHA.

42 ENGINEERING↗

The Effect of transient change in strain rate on plastic flow behaviour of Al-Mg-Si alloy at elevated temperatures

In extrusion forging processes, the abrupt changes in strain rate follows the plastic deformation of a material within the deforming zone. To simulate accurately this effect, the specific experimental investigation of the plastic flow during the transient change in strain rate should be performed. The present paper deals with the investigation of this effect on the flow stress of an Al-Mg-Si alloy during its deformation at 350 deg. C. The investigation consists of two steps. Both steps are connected to the monotonic uniaxial compression loading of a cylindrical specimen. During the first step the flow behaviour of the alloy is investigated at the constant strain rate wihin the range of 0.1-50 s{sup -1} at the temperature range of 350-430 deg. C. During the second step the strain rate is abruptly increased or decreased from its current value at a fixed engineering strain of 17-21%. From the beginning of the test up to the strain of 17-21% the value of the strain rate is constant and equal to either 1 s{sup -1} or 10 s{sup -1}. At the strain of 17-21% the value of a strain rate is either increased to 10 s{sup -1} or decreased to 1 s{sup -1}.The results of the experimental investigations were used to determine the isothermal flow stress-strain curves of the Al-Mg-Si alloy as well as the heat effect of plastic deformation of the alloy. On basis of these curves, the strain rate sensitivity index m as a function of true strain and temperature was determined. This parameter allows to optimize a technological process of hot forging of the aluminium alloy as well as it is very important data for the construction of a phenomenological flow stress model.

36 MATERIALS SCIENCE↗

The strain path dependence of plastic deformation response of AA5754: Experiment and modeling

This work presents modeling of experiments on a balanced biaxial (BB) pre-strained AA5754 alloy, subsequently reloaded uniaxially along the rolling direction and transverse direction. The material exhibits a complex plastic deformation response during the change in strain path due to 1) crystallographic texture, 2) aging (interactions between dislocations and Mg atoms) and 3) recovery (annihilation and re-arrangement of dislocations). With a BB prestrain of about 5 %, the aging process is dominant, and the yield strength for uniaxially deformed samples is observed to be higher than the flow stress during BB straining. The strain hardening rate after changing path is, however, lower than that for pre-straining. Higher degrees of pre-straining make the dynamic recovery more active. The dynamic recovery at higher strain levels compensates for the aging effect, and results in: 1) a reduction of the yield strength, and 2) an increase in the hardening rate of re-strained specimens along other directions. The yield strength of deformed samples is further reduced if these samples are left at room temperature to let static recovery occur. The synergistic influences of texture condition, aging and recovery processes on the material response make the modeling of strain path dependence of mechanical behavior of AA5754 challenging. In this study, the influence of crystallographic texture is taken into account by incorporating the latent hardening into a visco-plastic self-consistent model. Different strengths of dislocation glide interaction models in 24 slip systems are used to represent the latent hardening. Moreover, the aging and recovery effects are also included into the latent hardening model by considering strong interactions between dislocations and dissolved atom Mg and the microstructural evolution. These microstructural considerations provide a powerful capability to successfully describe the strain path dependence of plastic deformation behavior of AA5754.

36 MATERIALS SCIENCE↗

Improving the mechanical properties of Zr-based bulk metallic glass by controlling the activation energy for β-relaxation through plastic deformation

The mechanism of plastic deformation in bulk metallic glasses (BMGs) is widely believed to be based on a shear transformation zone (STZ). This model assumes that a shear-induced atomic rearrangement occurs at local clusters that are a few to hundreds of atoms in size. It was recently postulated that the potential energy barrier for STZ activation, W{sub STZ}, calculated using the cooperative shear model, is equivalent to the activation energy for β-relaxation, E{sub β}. This result suggested that the fundamental process for STZ activation is the mechanically activated β-relaxation. Since the E{sub β} value and the glass transition temperature T{sub g} of BMGs have a linear relation, that is, because E{sub β} ≈ 26RT{sub g}, the composition of the BMG determines the ease with which the STZ can be activated. Enthalpy relaxation experiments revealed that the BMG Zr{sub 50}Cu{sub 40}Al{sub 10} when deformed by high-pressure torsion (HPT) has a lower E{sub β} of 101 kJ/mol. The HPT-processed samples accordingly exhibited tensile plastic elongation (0.34%) and marked decreases in their yield strength (330 MPa). These results suggest that mechanically induced structural defects (i.e., the free volume and the anti-free volume) effectively act to reduce W{sub STZ} and increase the number of STZs activated during tensile testing to accommodate the plastic strain without requiring a change in the composition of the BMG. Thus, this study shows quantitatively that mechanically induced structural defects can overcome the compositional limitations of E{sub β} (or W{sub STZ}) and result in improvements in the mechanical properties of the BMG.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Elastic-plastic deformation of molybdenum single crystals shocked to 12.5 GPa: Crystal anisotropy effects

Here, to understand crystal anisotropy effects on shock-induced elastic-plastic deformation of molybdenum (Mo), results from high-purity single crystals shocked along [110] and [111] orientations to an elastic impact stress of 12.5 GPa were obtained and compared with the [100] results previously reported [A. Mandal and Y. M Gupta, J. Appl. Phys. 121, 045903 (2017)]. Measured wave profiles showed a time-dependent response, and strong anisotropy was observed in the elastic wave attenuation with the propagation distance, elastic limits, shock speeds, and overall structure of the wave profiles. Resolved shear stresses on {110} $\langle$111$\rangle$ and {112} $\langle$111$\rangle$ slip systems provided insight into the observed anisotropy in elastic wave attenuation and elastic limits and showed that shear stresses, and not longitudinal stresses, are a better measure of strength in shocked single crystals. Under shock compression, resolved shear stresses at elastic limits were comparable to the Peierls stress of screw dislocations in Mo. Elastic wave attenuation was rapid when shear stresses were larger than the Peierls stress. Large differences in the elastic limits under shock and quasi-static loading are likely a consequence of the large Peierls stress value for Mo. Numerically simulated wave profiles, obtained using the dislocation-based plasticity model described in the [100] work, showed good agreement with all measured wave profiles but could not differentiate between the {110} $\langle$111$\rangle$ and {112} $\langle$111$\rangle$ slip systems. Overall, experimental results and corresponding numerical simulations for the three crystal orientations have provided a comprehensive insight into shock-induced elastic-plastic deformation of Mo single crystals, including the development of a continuum material model.

36 MATERIALS SCIENCE↗

Utilizing integrated neutron diffraction and elastoplastic self-consistent crystal plasticity model to quantitatively assess the strengthening mechanism in Al–12.5Ce and Al–12.5Ce–0.4Mg alloys

An integrated in-situ neutron diffraction and elastic plastic self-consistent crystal plasticity (EPSC-CP) modeling scheme is performed on a binary Al–12Ce alloy and a ternary Al–12Ce–0.4Mg alloys. Using this scheme, the constitutive parameters, i.e. elastic constants and slip system parameters of individual phases can be calibrated which can be used in microstructure-based CP models to predict materials performance. From this study, it is shown that the elastic constants of Al 11 Ce 3 intermetallics calculated from density function theory calculation in the literature are rather accurate. When applied to the EPSC-CP model, the lattice strains of both the binary and ternary alloys are correctly predicted as compared with experiments, and large lattice strain differences between Al (100) plane and Al 11 Ce 3 (010) plane are demonstrated. The slip system parameters calibrated by the scheme shows that the addition of 0.4 wt% Mg in the alloy has little influence on the critical resolved shear stress of initial dislocation glide in the Al matrix which caused plastic yield in the material. This can be explained by the very dilute Mg solute content in the Al solid solution, causing large spacing of Al–Mg lattice misfit sites and little impact on resistance of dislocation glide at initial yield. The 0.4 wt% Mg addition, on the other hand, has a large influence on the hardening term in the slip system parameters, indicating those Al–Mg misfit sites do help dislocation accumulation during the deformation. The impact of dilute Mg addition on the Al slip system parameters is also reflected in the flow behavior of the ternary alloy: little impact on the yield stress, but a large impact on working hardening and tensile strength of the materials which is consistent with the literature.

36 MATERIALS SCIENCE↗

Unraveling the discontinuous plastic flow of a Co-Cr-Fe-Ni-Mo multiprincipal-element alloy at deep cryogenic temperatures

We report an analysis of the discontinuous plastic flow of a multiprincipal-element alloy, Co 17.5 Cr 12.5 Fe 55 Ni 10 Mo 5 (atomic percent, at. %), in the temperature range of 0.5–4.2 K showing serrated deformation curves. Using the analytical techniques, we studied the statistics of the stress drops associated with the unstable plastic flow. The analysis showed that the complexity and heterogeneity of a discontinuous plastic flow were reduced when the temperature was lowered. This behavior was associated with the effects of dynamic recovery and adiabatic heating on the dislocation-density evolution.

36 MATERIALS SCIENCE↗

TH-C-19A-10: Systematic Evaluation of Photodetectors Performances for Plastic Scintillation Dosimetry

Purpose: To assess and compare the performance of different photodetectors likely to be used in a plastic scintillation detector (PSD). Methods: The PSD consists of a 1 mm diameter, 10 mm long plastic scintillation fiber (BCF-60) which is optically coupled to a clear 10 m long optical fiber of the same diameter. A light-tight plastic sheath covers both fibers and the scintillator end is sealed. The clear fiber end is connected to one of the following six studied photodetectors: two polychromatic cameras (one with an optical lens and one with a fiber optic taper replacing the lens); a monochromatic camera with the same optical lens; a PIN photodiode; an avalanche photodiode (APD); and a photomultiplier tube (PMT). Each PSD is exposed to both low energy beams (120, 180, and 220 kVp) from an orthovoltage unit, and high energy beams (6 MV and 23 MV) from a linear accelerator. Various dose rates are explored to identify the photodetectors operating ranges and accuracy. Results: For all photodetectors, the relative uncertainty remains under 5 % for dose rates over 3 mGy/s. The taper camera collects four times more signal than the optical lens camera, although its standard deviation is higher since it could not be cooled. The PIN, APD and PMT have higher sensitivity, suitable for low dose rate and out-of-field dose monitoring. PMT's relative uncertainty remains under 1 % at the lowest dose rate achievable (50 μGy/s), suggesting optimal use for live dosimetry. Conclusion: A set of 6 photodetectors have been studied over a broad dose rate range at various energies. For dose rate above 3 mGy/s, the PIN diode is the most effective photodetector in term of performance/cost ratio. For lower dose rate, such as those seen in interventional radiology, PMTs are the optimal choice. FQRNT Doctoral Research Scholarship.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-486: In Vivo Skin Dosimetry Using the Exradin W1 Plastic Scintillation Detector for Passively Scattered Proton Beam Therapy

Purpose: To evaluate the accuracy and usefulness of plastic scintillation detectors used for skin dosimetry of patients undergoing passive scatter proton therapy. Methods: Following an IRB approved protocol, six patients undergoing passively scattered proton beam therapy for prostate cancer were selected for in vivo skin dosimetry using the Exradin W1 plastic scintillator. The detector was calibrated on a Cobalt-60 unit, and phantom measurements in the proton beam with the W1 and a calibrated parallel plate ion chamber were used to account for the under-response due to high LET at energies used for treatment. Measurements made in a heated water tank were used to account for temperature dependence. For in vivo measurements, the W1 is fixed to the patient’s skin with medical tape in the center of each of two laterally opposed treatment fields. Measurements will be performed once per week for each patient for the duration of treatment, for a total of thirty six measurements. The measured dose will be compared to the expected dose, extracted from the Eclipse treatment planning system. The average difference over all measurements and per-patient will be computed, as well as standard deviations. Results: The calibrated detector exhibited a 7% under-response in 225 and 250 MeV beams, and a 4% under-response when used at 37 °C (relative to the response at the calibration temperature of 20 °C). Patient measurements are ongoing. Conclusion: The Exradin W1 plastic scintillator detector is a strong candidate for in vivo skin dosimetry in passively scattered proton beams as PSDs are water equivalent and very small (2mm in diameter), permitting accurate measurements that do not perturb the delivered dose. This project was supported in part by award number CA182450 from the National Cancer Institute.

60 APPLIED LIFE SCIENCES↗

Energy dependent response of plastic scintillation detectors to photon radiation of low to medium energy

Purpose: Plastic scintillation detectors are promising candidates for the dosimetry of low- to medium-energy photons but quantitative knowledge of their energy response is a prerequisite for their correct use. The purpose of this study was to characterize the energy dependent response of small scintillation detectors (active volume <1 mm{sup 3}) made from the commonly used plastic scintillator BC400. Methods: Different detectors made from BC400 were calibrated at a number of radiation qualities ranging from 10 to 280 kV and at a {sup 60}Co beam. All calibrations were performed at the Physikalisch-Technische Bundesanstalt, the National Metrology Institute of Germany. The energy response in terms of air kerma, dose to water, and dose to the scintillator was determined. Conversion factors from air kerma to dose to water and to dose to the scintillator were derived from Monte Carlo simulations. In order to quantitatively describe the energy dependence, a semiempirical model known as unimolecular quenching or Birks’ formula was fitted to the data and from this the response to secondary electrons generated within the scintillator material BC400 was derived. Results: The detector energy response in terms of air kerma differs for different scintillator sizes and different detector casings. It is therefore necessary to take attenuation within the scintillator and in the casing into account when deriving the response in terms of dose to water from a calibration in terms of air kerma. The measured energy response in terms of dose to water for BC400 cannot be reproduced by the ratio of mean mass energy-absorption coefficients for polyvinyl toluene to water but shows evidence of quenching. The quenching parameter kB in Birks’ formula was determined to be kB = (12.3 ± 0.9) mg MeV{sup −1} cm{sup −2}. Conclusions: The energy response was quantified relative to the response to {sup 60}Co which is the common radiation quality for the calibration of therapy dosemeters. The observed energy dependence could be well explained with the assumption of ionization quenching as described by Birks’ formula. Plastic scintillation detectors should be calibrated at the same radiation quality that they will be used at and changes of the spectrum within the application need to be considered. The authors results can be used to evaluate the range of validity of a given calibration.

60 APPLIED LIFE SCIENCES↗

Gradient Plasticity Model and its Implementation into MARMOT

The influence of strain gradient on deformation behavior of nuclear structural materials, such as body-centered cubic (bcc) iron alloys has been investigated. We have developed and implemented a dislocation based strain gradient crystal plasticity material model. A mesoscale crystal plasticity model for inelastic deformation of metallic material, bcc steel, has been developed and implemented numerically. Continuum Dislocation Dynamics (CDD) with a novel constitutive law based on dislocation density evolution mechanisms was developed to investigate the deformation behaviors of single crystals, as well as polycrystalline materials by coupling CDD and crystal plasticity (CP). The dislocation density evolution law in this model is mechanism-based, with parameters measured from experiments or simulated with lower-length scale models, not an empirical law with parameters back-fitted from the flow curves.

continuous dislocation dynamics↗

MAGNETAR FIELD EVOLUTION AND CRUSTAL PLASTICITY

The activity of magnetars is believed to be powered by colossal magnetic energy reservoirs. We sketch an evolutionary picture in which internal field evolution in magnetars generates a twisted corona, from which energy may be released suddenly in a single giant flare, or more gradually through smaller outbursts and persistent emission. Given the ages of magnetars and the energy of their giant flares, we suggest that their evolution is driven by a novel mechanism: magnetic flux transport/decay due to persistent plastic flow in the crust, which would invalidate the common assumption that the crustal lattice is static and evolves only under Hall drift and Ohmic decay. We estimate the field strength required to induce plastic flow as a function of crustal depth, and the viscosity of the plastic phase. The star’s superconducting core may also play a role in magnetar field evolution, depending on the star’s spindown history and how rotational vortices and magnetic fluxtubes interact.

79 ASTRONOMY AND ASTROPHYSICS↗

Using handheld plastic scintillator detectors to triage individuals exposed to a radiological dispersal device

After a radiological dispersal device (RDD) event, people could become internally contaminated by inhaling dispersed radioactive particles. A rapid method to screen individuals who are internally contaminated is desirable. Such initial screening can help in prompt identification of those who are highly contaminated and in prioritizing individuals for further and more definitive evaluation such as laboratory testing. The use of handheld plastic scintillators to rapidly screen those exposed to an RDD with gamma-emitting radionuclides was investigated in this study. The Monte Carlo N-Particle transport code was used to model two commercially available plastic scintillation detectors in conjunction with anthropomorphic phantom models to determine the detector response to inhaled radionuclides. Biokinetic models were used to simulate an inhaled radionuclide and its progression through the anthropomorphic phantoms up to 30 d after intake. The objective of the study was to see if internal contamination levels equivalent to 250 mSv committed effective dose equivalent could be detected using these instruments. Five radionuclides were examined: {sup 60}Co, {sup 137}Cs, {sup 192}Ir, {sup 131}I and {sup 241}Am. The results demonstrate that all of the radionuclides except {sup 241}Am could be detected when placing either one of the two plastic scintillator detector systems on the posterior right torso of the contaminated individuals.

61 RADIATION PROTECTION AND DOSIMETRY↗

FINITE ELEMENT AND POLYCHROMATIC MICRODIFFRACTION ANALYSIS OF PLASTIC DEFORMATION MICROMECHANICS NEAR A GRAIN BOUNDARY

In this study we report the inhomogeneities of plastic deformation in the natural Ni bicrystal after uniaxial loading. Focused, polychromatic synchrotron X-ray microbeam together with orientation imaging microscopy, scanning electron microscopy, and finite element simulations were used to characterize the physics of geometrically necessary dislocations formation and collective behavior during plastic deformation. Crystallographic orientation of the grain essentially determined its plastic response at submicron level during deformation. Finite element simulations were used to understand the influence of grain orientation and initial structural inhomogeneities on the geometrically necessary dislocations arrangement and distribution. Strain in both grains increases in the vicinity of the coherent boundary.

43 PARTICLE ACCELERATORS↗

An Elastic-Plastic and Strength Prediction Model for Injection-Molded Long-Fiber Thermoplastics

This paper applies a recently developed model to predict the elastic-plastic stress/strain response and strength of injection-molded long-fiber thermoplastics (LFTs). The model combines a micro-macro constitutive modeling approach with experimental characterization and modeling of the composite microstructure to determine the composite stress/strain response and strength. Specifically, it accounts for elastic fibers embedded in a thermoplastic resin that exhibits the elastic-plastic behavior obeying the Ramberg-Osgood relation and J-2 deformation theory of plasticity. It also accounts for fiber length, orientation and volume fraction distributions in the composite formed by the injection-molding process. Injection-molded-long-glass-fiber/polypropylene (PP) specimens were prepared for mechanical characterization and testing. Fiber length, orientation, and volume fraction distributions were then measured at some selected locations for use in the computation. Fiber orientations in these specimens were also predicted using an anisotropic rotary diffusion model developed for LFTs. The stress-strain response of the as-formed composite was computed by an incremental procedure that uses the Eshelby’s equivalent inclusion method, the Mori-Tanaka assumption and a fiber orientation averaging technique. The model has been validated against the experimental stress-strain results obtained for these long-glass-fiber/PP specimens.

36 MATERIALS SCIENCE↗