Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “performance degradation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

A generalized correlation of experimental flat-plate collector performance

A generalized collector performance correlation was derived and shown by experimental verification to be of the proper form to account for the majority of the variable conditions encountered both in outdoor and in indoor collector tests. This correlation permits a determination of collector parameters which are essentially nonvarying under conditions which do vary randomly (outdoors) or conditions which vary in a controlled manner (indoors - simulator). It was shown that correlation of the experimental performance of collectors allows the following: (1) comparisons of different collector designs; (2) collector performance prediction under conditions that differ from the conditions of the test program; and (3) monitoring performance degradation effects.

Simon, F. F.↗

Carrier and symbol synchronization system performance study

Results pertinent to predicting the performance of convolutionally encoded binary phase-shift keyed communication links were presented. The details of the development are provided in four sections. These sections are concerned with developing the bit error probability performance degradations due to PN despreading by a time-shared delay locked loop, the Costas demodulation process, symbol synchronization effects and cycle slipping phenomena in the Costas loop. In addition, Costas cycle slipping probabilities are studied as functions of Doppler count time and signal-to-noise conditions. The effect of cycle slipping in the symbol synchronizer is also studied as a function of channel Doppler and other frequency uncertainties.

Lindsey, W. C.↗

A generalized correlation of experimental flat-plate collector performance

A generalized correlation of flat-plate collector performance obtained by outdoor and indoor test methods is presented. This correlation shows that the indoor (simulator) test approach is a special case of the general situation of variable solar conditions. The important feature of the generalized correlation is that it permits a separation of the solar variables (flux, incident angle, etc.) which affect collector performance from the collector parameters (absorptance, transmittance, heat loss, etc.) which also affect collector performance and which are uniquely part of a given collector design. The correlation permits an evaluation of the relative merits of using instantaneous, hourly and daily collector efficiencies in obtaining a good collector correlation. The question of the transient behavior outdoors of a collector is an important part of determining whether to use instantaneous, hourly or daily efficiency values in a correlation approach. Correlation of the experimental performance of collectors allows the following: (1) comparisons of different collector designs, (2) collector performance prediction under conditions that differ from the conditions of the test program, and (3) monitoring performance degradation effects.

Simon, F. F.↗

Spatially non-uniform response of Al/x/Ga/1-x/As-GaAs heteroface cells

The presence of localized regions of poor current-voltage characteristic in heteroface solar cells made by liquid phase epitaxy of Al(x)Ga(1-x)As on GaAs was demonstrated by the formation of mesa diodes with better characteristics than the parent cell, and by direct observation with a flying spot scanner. The latter was also correlated with the characteristics of subsequently etched mesas. Visible features on the cells were found to be harmless or actually regions of enhanced collection in some cases, and responsible for cell performance degradation in others.

Sekela, A. M.↗

Status of recent aircraft braking and cornering research

The sources of degraded performance which sometimes occurs under adverse runway conditions, are investigated to obtain data necessary to the development of more advanced systems, in an effort to insure safe ground handling operations under all-weather conditions. Tire-to-ground friction characteristics are determined under braking conditions which closely resemble those of airplanes under heavy braking. Braking data from single-wheel landing loads track tests are related with those available from full-scale flight tests.

Stubbs, S. M.↗

Computation of spacecraft signal raypath trajectories relative to the sun

A computer program (CTS 41B) used to determine the trajectory of a spacecraft signal raypath was updated to increase its usefulness during solar conjunctions (CTS 41C). The closest point of approach of the raypath to the sun is projected onto the surface and the solar latitude and longitude calculated. A sample computation and plots are given for the 1976 Viking solar conjunction. Eventually it may be possible to predict the communication link performance degradation in the near sun region due to solar activity.

Cannon, R.↗

Optimum design and performance of Costas receivers containing soft bandpass limiters

This paper investigates several key questions concerning the mechanization and design of a Costas receiver for reconstruction of a carrier from a suppressed carrier signal. For baseband NRZ encoded data symbols and a soft bandpass limiter preceding the loop, several design issues which are considered herein and which affect acquisition and tracking performance are: (1) The choice of an IF bandwidth. (2) The optimum choice of the Costas arm filter bandwidths as well as the spectral roll-off characteristics. (3) The optimum choice of loop bandwidth to data rate ratio for a given signal-to-noise ratio. (4) The signal suppression factor and the combined limiter-squaring loss. (5) The variations in loop bandwidth and damping with signal level. (6) The choice of the limiter transfer characteristic. (7) Performance degradation due to the presence of a limiter. Various new results in system design are presented and typical numerical results are given and graphically demonstrated in SNR regions of practical interest. The theory is applicable to the design of carrier reconstruction loops required in the implementation of spread spectrum communication receivers.

Lindsey, W. C.↗

Fabrication and test of a variable conductance heat pipe

A variable conductance heat pipe (VCHP) with feedback control was fabricated with a reservoir-condenser volume ratio of 10 and an axially grooved action section. Tests of the heat transport capability were greater than or equal to the analytical predictions for the no gas case. When gas was added, the pipe performance degraded by 18% at zero tilt as was expected. The placement of the reservoir heater and the test fixture cooling fins are believed to have caused a superheated vapor condition in the reservoir. Erroneously high reservoir temperature indications resulted from this condition. The observed temperature gradients in the reservoir lend support to this theory. The net result was higher than predicted reservoir temperatures. Also, significant increases in minimum heat load resulted for controller set point temperatures higher than 0 C. At 30 C, control within the tolerance band was maintained, but high reservoir heater power was required. Analyses showed that control is not possible for reasonably low reservoir heater power. This is supported by the observation of a significant reservoir heat leak through the condenser.

Lehtinen, A. M.↗

Simulator study of the effect of visual-motion time delays on pilot tracking performance with an audio side task

The effect of time delay was determined in the visual and motion cues in a flight simulator on pilot performance in tracking a target aircraft that was oscillating sinusoidally in altitude only. An audio side task was used to assure the subject was fully occupied at all times. The results indicate that, within the test grid employed, about the same acceptable time delay (250 msec) was obtained for a single aircraft (fighter type) by each of two subjects for both fixed-base and motion-base conditions. Acceptable time delay is defined as the largest amount of delay that can be inserted simultaneously into the visual and motion cues before performance degradation occurs. A statistical analysis of the data was made to establish this value of time delay. Audio side task provided quantitative data that documented the subject's work level.

Riley, D. R.↗

Power density in direct nuclear-pumped He-3 lasers

The interaction of neutron beams with He-3 gas is of interest for nuclear pumped lasers. The effects of spectral dependence of the neutron beam, neutron attenuation in the gas-filled laser tube, and transport of the charged-particle He-3(n, p)He-3 reaction products are treated in detail. An expression for the energy density as a function of position within the tube, tube radius, operating pressure, and neutron fluence is given. The maximum energy density within the optical cavity is achieved when the tube radius is 3.26/P where P (atm) is the operating pressure. The variation of radius by 50% above and below optimum will change the energy density at most by 10%, although performance degrades quickly for radii outside this range. If the optimum tube radius is used for each operating pressure, then the power density on the centerline (kW/cu cm) is given as 9.3 x 10 to the -18th power times the operating pressure times flux in a thermal neutron environment of flux (n/sq cm sec).

Wilson, J. W.↗

Largo hot water system long range thermal performance test report, addendum

The test procedure used and the test results obtained during the long range thermal performance tests of the LARGO Solar Hot Water System under natural environmental conditions are presented. Objectives of these tests were to determine the amount of energy collected, the amount of power required for system operation, system efficiency, temperature distribution, and system performance degradation.

Source record↗

Long-term weathering effects on the thermal performance of the Lennox/Honeywell (liquid) solar collector

The test procedures used and the results obtained during the evaluation test program of the Lennox/Honeywell double covered liquid solar collector. The tests were performed under simulated conditions, following long-term exposure to natural weathering conditions. The Lennox/Honeywell collector is a flat-plate solar collector. The absorber plate is steel with copper tubes bonded on the upper surface, and is coated with black chrome. Visual inspection of the collector indicated slight discoloration of the absorber plate. Results indicate that performance degradation had occurred. Absorptivity and/or transmissivity decreased as a result of the weathering.

Source record↗

Discrete-time pilot model

Pilot behavior is considered as a discrete-time process where the decision making has a sequential nature. This model differs from both the quasilinear model which follows from classical control theory and from the optimal control model which considers the human operator as a Kalman estimator-predictor. An additional factor considered is that the pilot's objective may not be adequately formulated as a quadratic cost functional to be minimized, but rather as a more fuzzy measure of the closeness with which the aircraft follows a reference trajectory. All model parameters, in the digital program simulating the pilot's behavior, were successfully compared in terms of standard-deviation and performance with those of professional pilots in IFR configuration. The first practical application of the model was in the study of its performance degradation when the aircraft model static margin decreases.

Cavalli, D.↗

Fabrication and testing of silver-hydrogen cells

Silver electrodes containing various additives were fabricated and tested in single electrode cells in order to improve the electrochemical utilization of sintered silver cathodes in Ag-H2 aerospace batteries. A standard stack arrangement was used which featured a NASA-developed organic-inorganic separator. All cells were cycled in a regime designed to remove 75% of the cells nominal capacity based on 3.3 gms/AHr Ag utilization. In cases where performance degradation was observed, the main feature mode appeared to be corrosion of either the expanded silver current collector or the connection between the silver electrode and the electrode tab. Promising silver electrodes from single electrode studies were used in the construction of 35 AHr Ag-H2 cells. Two such cells were constructed and installed in heavy walled pressure vessels for testing. Based on the data obtained from all cells tested during the program, four lightweight 35 AHr cells were fabricated. During acceptance testing these cells yielded an average gravimetric energy density of 30 WHr/1b.

Debicarri, D. J.↗

Long-term weathering effects on the thermal performance of the Libbey-Owens-Ford (liquid) solar collector

Thermal performance tests were conducted on the Libbey-Owens-Ford liquid collector, following long term exposure to natural weathering conditions. Visual inspection of the collector, prior to the retest, indicated noticeable clouding of the inner cover glass, probably resulting from outgassing of the insulation. The absorber plate also showed some discoloration. The test results indicated that performance degradation had occurred at inlet temperatures significantly above ambient. The change in the slope of the efficiency curve, from the original data, is a direct indicator of an increase in the collector heat loss coefficient.

Source record↗

Shuttle Ku-band and S-band communications implementations study

The interfaces between the Ku-band system and the TDRSS, between the S-band system and the TDRSS, GSTDN and SGLS networks, and between the S-band payload communication equipment and the other Orbiter avionic equipment were investigated. The principal activities reported are: (1) performance analysis of the payload narrowband bent-pipe through the Ku-band communication system; (2) performance evaluation of the TDRSS user constraints placed on the S-band and Ku-band communication systems; (3) assessment of the shuttle-unique S-band TDRSS ground station false lock susceptibility; (4) development of procedure to make S-band antenna measurements during orbital flight; (5) development of procedure to make RFI measurements during orbital flight to assess the performance degradation to the TDRSS S-band communication link; and (6) analysis of the payload interface integration problem areas.

Huth, G. K.↗

Effect of parasitic plasma currents on solar-array power output

Solar-array voltage-current curves are calculated by assuming the existence of parasitic loads that consist of local currents of charged particles collected by the array. Three cases of interest are calculated to demonstrate how the distribution and magnitude of parasitic currents affect output. Solar array performance degradation became significant when the total parasitic current plus the load current exceeded the short-circuit current. Approximate graphical methods were useful for many applications. Power loss, which was calculated by summing the product of parasitic current and the local potential, underestimated the loss in maximum power.

Domitz, S.↗

LDEF transverse flat plate heat pipe experiment /S1005/

The paper describes the Transverse Flat Plate Heat Pipe Experiment. A transverse flat plate heat pipe is a thermal control device that serves the dual function of temperature control and mounting base for electronic equipment. In its ultimate application, the pipe would be a lightweight structure member that could be configured in a platform or enclosure and provide temperature control for large space structures, flight experiments, equipment, etc. The objective of the LDEF flight experiment is to evaluate the zero-g performance of a number of transverse flat plate heat pipe modules. Performance will include: (1) the pipes transport capability, (2) temperature drop, and (3) ability to maintain temperature over varying duty cycles and environments. Performance degradation, if any, will be monitored over the length of the LDEF mission. This information is necessary if heat pipes are to be considered for system designs where they offer benefits not available with other thermal control techniques, such as minimum weight penalty, long-life heat pipe/structural members.

Robinson, G. A., Jr.↗