An important issue for electricity system operators is the estimation of renewables' capacity contributions to reliably meeting system demand, or their capacity value. While the capacity value of thermal generation can be estimated easily, assessment of wind and solar requires a more nuanced approach due to the resource variability. Reliability-based methods, particularly assessment of the Effective Load-Carrying Capacity, are considered to be the most robust and widely-accepted techniques for addressing this resource variability. This report compares estimates of solar PV capacity value by the Regional Energy Deployment System (ReEDS) capacity expansion model against two sources. The first comparison is against values published by utilities or other entities for known electrical systems at existing solar penetration levels. The second comparison is against a time-series ELCC simulation tool for high renewable penetration scenarios in the Western Interconnection. Results from the ReEDS model are found to compare well with both comparisons, despite being resolved at a super-hourly temporal resolution. Two results are relevant for other capacity-based models that use a super-hourly resolution to model solar capacity value. First, solar capacity value should not be parameterized as a static value, but must decay with increasing penetration. This is because -- for an afternoon-peaking system -- as solar penetration increases, the system's peak net load shifts to later in the day -- when solar output is lower. Second, long-term planning models should determine system adequacy requirements in each time period in order to approximate LOLP calculations. Within the ReEDS model we resolve these issues by using a capacity value estimate that varies by time-slice. Within each time period the net load and shadow price on ReEDS's planning reserve constraint signals the relative importance of additional firm capacity.
Projected increases in electricity demand in the U.S. highlight the urgent need for effective load management to ensure grid reliability. As the building sector accounts for approximately 75% of electricity usage, enhancing energy efficiency and flexibility in this sector is crucial. Adopting district-level approaches offers significant advantages over traditional individual building analyses by enabling shared infrastructure and economies of scale. To navigate the data and computational challenges associated with modeling energy at the district level, prototype district models have been proposed as holistic, system-level solutions that capture complex interactions within typical configurations. This study presents these models as a reference tool for analyzing district-scale energy systems across various climate zones in the U.S. Developed with input from stakeholders, these models integrate varied building characteristics, inter-building connections, and energy system interactions. A case study utilizing the Urban Edge prototype district model, implemented on the URBANopt™ platform, evaluates multiple demand scenarios and the impact of distributed energy resources such as fuel-fired backup generators, photovoltaic systems, and batteries. Findings suggest that while new electric systems can significantly reduce annual energy use, they may also elevate peak electricity loads, with a notable 43% increase in heating-dominant climate zone 5B. The optimal backup power solutions vary based on location, influenced by factors such as utility rates and incentives. For example, PV and batteries perform well in high-cost regions like New York City, while diesel backup generators are more suitable for backup needs in climate zone 3A, such as Atlanta. Thus, this research highlights the importance of prototype district models for future district-scale energy planning.
This paper proposes a novel Soft-Actor-Critic (SAC) based Deep Reinforcement Learning (DRL) method for optimizing the cost of microgrid operation by leveraging load flexibility. The proposed SAC-DRL method is designed to coordinate the control of distributed energy resources (DERs) and flexible load, addressing practical energy billing formation by power distribution utilities. Key contributions include an innovative reward function to mitigate sparse reward challenges and a mixed control strategy for discrete and continuous variables, ensuring radial network topology and minimizing power loss. We evaluate the proposed method on the model of a real microgrid located in Southern California, U.S.. The SAC-DRL model is tested to demonstrate its efficacy in reducing grid dependence, optimizing resource use, and minimizing costs. The results highlight the potential of DRL in modern energy systems, offering a sustainable and economically efficient solution for energy management in microgrids.
Lawrence Berkeley National Laboratory (LBL) is working with the California Energy Commission (CEC) to determine the role of distributed generation (DG) in greenhouse gas reductions. The impact of DG on large industrial sites is well known, and mostly, the potentials are already harvested. In contrast, little is known about the impact of DG on commercial buildings with peak electric loads ranging from 100 kW to 5 MW. We examine how DG with combined heat and power (CHP) may be implemented within the context of a cost minimizing microgrid that is able to adopt and operate various smart energy technologies, such as thermal and photovoltaic (PV) on-site generation, heat exchangers, solar thermal collectors, absorption chillers, and storage systems. We use a mixed-integer linear program (MILP) that has the minimization of a site's annual energy costs as objective. Using 138 representative commercial sites in California (CA) with existing tariff rates and technology data, we find the greenhouse gas reduction potential for California's commercial sector. This paper shows results from the ongoing research project and finished work from a two year U.S. Department of Energy research project. To show the impact of the different technologies on CO2 emissions, several sensitivity runs for different climate zones within CA with different technology performance expectations for 2020 were performed. The considered sites can contribute between 1 Mt/a and 1.8 Mt/a to the California Air Resources Board (CARB) goal of 6.7Mt/a CO2 abatement potential in 2020. Also, with lower PV and storage costs as well as consideration of a CO2 pricing scheme, our results indicate that PV and electric storage adoption can compete rather than supplement each other when the tariff structure and costs of electricity supply have been taken into consideration. To satisfy the site's objective of minimizing energy costs, the batteries will be charged also by CHP systems during off-peak and mid-peak hours and not only by PV during sunny on-peak hours.
Experimental studies have identified peak cyclic forces, number of loading cycles, and loading rate as contributors to the regulation of bone metabolism. We have proposed a theoretical model that relates bone density to a mechanical stimulus derived from average daily cumulative peak cyclic 'effective' tissue stresses. In order to develop a non-invasive experimental model to test the theoretical model we need to: (1) monitor daily cumulative loading on a bone, (2) compute the internal stress state(s) resulting from the imposed loading, and (3) image volumetric bone density accurately, precisely, and reproducibly within small contiguous volumes throughout the bone. We have chosen the calcaneus (heel) as an experimental model bone site because it is loaded by ligament, tendon and joint contact forces in equilibrium with daily ground reaction forces that we can measure; it is a peripheral bone site and therefore more easily and accurately imaged with computed tomography; it is composed primarily of cancellous bone; and it is a relevant site for monitoring bone loss and adaptation in astronauts and the general population. This paper presents an overview of our recent advances in the areas of monitoring daily ground reaction forces, biomechanical modeling of the forces on the calcaneus during gait, mathematical modeling of calcaneal bone adaptation in response to cumulative daily activity, accurate and precise imaging of the calcaneus with quantitative computed tomography (QCT), and application to long duration space flight.
A launch vehicle ground-wind-loads program is underway at the NASA Langley Transonic Dynamics Tunnel. The objectives are to quantify key aerodynamic and structural characteristics that impact the occurrence of large wind-induced oscillations of a launch vehicle when exposed to ground winds prior to launch. Of particular interest is the dynamic response of a launch vehicle when a von Kármán vortex street forms in the wake of the vehicle resulting in quasiperiodic lift and drag forces. Vehicle response to these quasiperiodic forces can become quite large when the frequency of vortex shedding nears that of a lowly-damped structural mode thereby exciting a resonant response. Wind approaching the vehicle can be characterized by a varying speed with height and turbulence content. The combination of both the varying speed and turbulence content is referred to herein as the atmospheric boundary-layer. The importance of the atmospheric boundary-layer upon launch vehicle wind-induced oscillation response has long been questioned, and its effects are not well understood. Although there are several facilities around the world dedicated to replicating atmospheric boundary layers, the development of such a boundary layer in a wind tunnel capable of producing flight-representative Reynolds numbers for aeroelastically-scaled launch vehicle models has only recently been accomplished. The NASA Langley Transonic Dynamics Tunnel is capable of simulating flight-representative Reynolds numbers of launch vehicles on the pad and is uniquely capable of replicating many fluid-structure scaling parameters typical of aeroelastic tests. Recent test efforts successfully developed representative atmospheric boundary-layers for three launch sites in the Transonic Dynamics Tunnel, thereby allowing all known aerodynamic and fluid-structure coupling parameters to be simultaneously simulated for those sites. Dynamic aeroelastically-scaled models representative of typical large launch vehicles were constructed for testing. Aeroelastic scaling includes matching geometry, mode shapes, reduced frequencies, damping, running mass ratios, and running stiffness ratios. The models were tested in smooth uniform flow and then immersed in the atmospheric boundary-layer for comparison of these effects. Dynamic data were acquired measuring unsteady pressure, acceleration, and base bending moment. It was discovered that peak dynamic loads resulting from resonant wind-induced oscillation response are similar when acquired in either smooth uniform flow or an atmospheric boundary-layer. This indicates that resonant lock-in events are minimally impacted by representative turbulence and/or wind profile. Alternately, nonresonant wind-induced oscillation response events are stronger when acquired in an atmospheric boundary-layer. This indicates that a lowly-damped structural response will increase when exposed to an increased magnitude of random excitation, which is consistent with historical comparisons. Loads created by the resonant response events were substantially stronger than those from the nonresonant response events. Therefore, if testing is done to simply identify worst-case conditions and load magnitude, then smooth uniform flow is likely an adequate test technique. However, if nonresonant response loads are of primary interest, then atmospheric boundary-layer simulation is required.
Abstract Phase change materials (PCMs) can enhance the performance of energy systems by time shifting or reducing peak thermal loads. The effectiveness of a PCM is defined by its energy and power density—the total available storage capacity (kWh m −3 ) and how fast it can be accessed (kW m −3 ). These are influenced by both material properties as well as geometry of the energy systems; however, prior efforts have primarily focused on improving material properties, namely, maximizing latent heat of fusion and increasing thermal conductivity. The latter is often at the expense of the former. Advanced manufacturing techniques hold tremendous potential to enable co‐optimization of material properties and device geometry, while potentially reducing material waste and manufacturing time. There is an emerging body of research focused on additive manufacturing of PCM composites and devices for thermal energy storage (TES) and thermal management. In this article, the fundamentals and applications of PCMs are reviewed and recent additive manufacturing advances in latent heat TES for both the PCM composite and associated heat exchanger are discussed. A forward‐looking perspective on the future and potential of PCM additive manufacturing for TES and thermal management is provided.
Dependence existing among production parameters can significantly affect energy costs. For material removal processes, processing times and material amounts to be cut have positive dependence, and the dependence can affect energy costs by varying a peak electricity load. Existing methods to model the dependence of production parameters are based on parametric approaches that cannot accurately represent the dependence due to the rigid nature of parametric models. To address this issue, this study proposes a method to quantify dependence among manufacturing parameters through the application of the empirical copula to the dependence between the milling processing time and the amount of volume to be cut. The proposed method is illustrated by a case study of a manufacturing facility consisting of milling machines; a total of 27 scenarios are simulated for energy cost estimations. The case study clearly shows that the proposed method can capture the dependence between the milling parameters more accurately than a conventional dependence measure from parametric correlation models. Furthermore, the findings from this study would be useful to estimate energy costs in that the proposed method provides a better fit to real production data than conventional parametric approaches can.
To design a comprehensive view of ecosystem resource use, in this work we integrated parallel resource use efficiency observations into a multiple-resource use efficiency (mRUE) framework using a dynamic factor analysis model. Results from 56 site-years of eddy covariance data and mRUE factors for a site in the US Midwest show temporal dynamics and coherence (using Pearson’s R) among resources are associated with interannual variation in precipitation. Loading factors are derived from mRUE observations and quantify how strongly data are connected to the underlying ecosystem state. Water and light resource use loading factors are coherent at annual timescales (Pearson’s R of 0.86), whereas declining patterns of carbon use efficiency loading factors highlight the ecosystem’s trade-off between carbon uptake and respiration during the growing season. At annual and monthly timescales, influence decreases from ~85 to ~65% for loading factors for carbon use, while influence of light use loading factors peaks to ~60% at growing season timescales. Quantifying variation in ecosystem function provides novel insights into the temporal dynamics of changing significance of multiple resources to ecosystem function.
By using an As{sub 2}Se{sub 3} based holey fiber (HF) with a normal flat dispersion profiles, a flattened and broadband mid-infrared super-continuum generation is analysed. The transmission of an ultra-short pulse in the HF is numerically simulated by solving the generalized nonlinear Schrödinger equation under various parameters. The simulation results show that, by launching a pulse with a width of 50 fs and a peak power of 4.25 kW at 4375 nm into the 6 mm-long HF, a flat and broadband super-continuum at 3 dB level is successfully generated. The super-continuum covers the wavelengths from 3866 to 5958 nm which is the largest flat bandwidth reported in such a short fiber.
The adaptive step-size methods including conservation quantity error method (CQEM) and local error method (LEM) are described and used to investigate the femtosecond pulse evolution in liquid-core photonic crystal fibers. The efficiency and accuracy of the numerical results obtained from CQEM and LEM in frequency domain (FD) and time domain (TD) are compared and discussed under the fixed numerical parameters respectively. The numerical results represent that LEM has the higher accuracy due to the integration of nonlinear operator that is more efficient than CQEM. The femtosecond pulse evolution in liquid-core photonic crystal fiber is described and analyzed using LEM. Moreover, the influences of the peak power of pulse and length of liquid-core photonic crystal fibers on the supercontinuum generation are also obtained based on LEM-FD. This study is helpful optimizing the numerical process in ultra-short pulse evolution based on adaptive step-size methods.
In this paper, we experimentally and theoretically investigate the stability and uniformity of multi-wavelength Brillouin-erbium fiber laser based on four-wave mixing (FWM). Multi-wavelength generation is limited by cross-gain saturation between different wavelengths from homogeneous broadening of erbium-doped fiber. Modeling coupled-mode equation for FWM and analyzing the influence of FWM on multi-wavelength generation. 16 orders Brillouin Stokes (BS) waves with a wavelength spacing of 0.084 nm are obtained experimentally within a 3 dB bandwidth by the FWM effect in a 100 m highly nonlinear fiber (HNLF), power distribution of each laser is uniform and peak power fluctuation is less than 1.184 dB within a 10 dB bandwidth, the outputs exhibit good time stability and uniformity. Compared with the same configuration, the laser without HNLF has only 9 orders stable BS waves within 3 dB bandwidth, and high-order Stokes wave shows significant waveform jitter and power fluctuation.
The key to improve the strength of Al/steel dissimilar joint is to toughen the hard and brittle interfacial intermetallics. Introducing soft and tough dispersions into the interfacial intermetallics would be a promising method. In the present study, Zn-Al alloy (Zn-22Al) was used as the filler metal to generate dispersions in the interfacial intermetallics matrix of dissimilar laser Al/steel joint. The results have shown that soft and tough dispersions, i.e., FeZn{sub 10,} Al-rich amorphous phase, and Zn solid solution, were successfully introduced into the hard and brittle Fe{sub 2}Al{sub 5−x}Zn{sub x} matrix. The formation of these dispersions was resulted from diffusion of elements Fe and Al and infiltration of liquid Zn along the grain boundaries of Fe{sub 2}Al{sub 5−x}Zn{sub x} matrix and the subsequent chemical reaction and solidification. With this kind of interfacial microstructure, the joint exhibited a stable peak fracture load of 1200 N even though the interfacial layer thickness increased from 20 to 45 μm. This was because the interfacial layer was toughened by the soft and tough dispersions. Using this example, introduction of soft and tough dispersions into hard and brittle intermetallics matrix to toughen interfacial layer and then strengthening of dissimilar joints will be highlighted.
Powder compacts of a commercially-available pyrite, FeS 2 , have been subjected to controlled, quantitative high pressure shock loading at peak pressures from 7.5-22 GPa. The profiles of the x-ray diffraction lines have been examined to determine the reduction of the crystallite (domain) size and the introduction of residual microstrain due to defects and dislocations resulting from the transmission and interaction of the shockwave. Pyrite experience a surprisingly smaller profile broadening than observed for all other materials under similar shock conditions, suggesting a much more refractory character. Such small changes are consistent with low defect densities and with the relative low reaction activity (oxidation of sulfide to sulfate by humid air) observed on this material in the complementary studies.
Energy storage for stationary use is gaining traction both at the grid scale and distributed level. As renewable energy generation increases, energy storage is needed to compensate for the volatility of renewable over various time scales. This requires energy storage that is tailored for various energy to power (E/P) ratios. Other applications for energy storage include peak shaving, time shifting, load leveling, VAR control, frequency regulation, spinning reserves and other ancillary applications. While the need for energy storage for stationary applications is obvious, the regulations that determine the economic value of adding storage are at various stages of development. This has created a reluctance on the part of energy storage manufacturers to develop a suite of storage systems that can address the myriad of applications associated with stationary applications. Deployment of battery energy storage systems in the transportation sector is ahead of the curve with respect to the stationary space. Batteries, along with battery management systems (BMS) have been deployed for hybrid electric vehicles (HEVs), plug-in hybrid electric vehicles (PHEVs) and electric vehicles (EVs). HEVs have now been deployed for 12 years, while PHEVs for 8 and EVs for 4 years. Some of the batteries are approaching end of life within the vehicle, and are ready to be taken off for recycling and disposal. Performance within a vehicle is non-negotiable in terms of miles traveled per charge, resulting in the batteries retaining a significant portion of their life. For stationary applications, the remaining energy and power of the battery can still be used by grouping together a few of these batteries. This enables getting the most of these batteries, while ensuring that performance is not compromised in either the automotive or stationary applications. This work summarizes the opportunities for such re-purposing of automotive batteries, along with the advantages and limitations
Fused deposition modeling (FDM) printed polymers are rarely used as a structural material due to anisotropic and low mechanical properties compared with conventional composites. In recent years, greater need has been expressed for recycling of materials, such as recyclable FDM, at the end of service life to reduce environmental pollution and manufacture cost. However, how the amount of resin uptake in the skin and skin/core interphase affects the bending and shear performance of the sandwich composites when replacing the low strength and ductile core (conventional core) with a high strength and brittle core (FDM printed PLA (polylactic acid) core) still remains unclear. A new manufacturing routine is needed to improve the incorporation of FDM printed polymers in composite structures. In this work, FDM printed PLA was used as core material and sandwiched between two unidirectional glass fiber reinforced polymer (GFRP) skins to form a sandwich composite by compression-molding (CM) process, which provides a good manufacturing strategy for skin/core interphase modification. The significance of the CM process is proved by investigating the effect of resin uptake on bending and in-plane/out-of-plane shear performances. Current first order shear deformation (FSDT) theory lacks a direct connection between the in-plane shear stress and out-of-shear stress in the core region of sandwich composites. With the help of DIC, a connection between the in-plane shear and the out-of-plane shear strain was built and in-plane shear properties can acquire through out-of-plane shear properties, hence reducing the redundancy of sample preparation or the need for simulation. A significant improvement was found compared with the optimized resin uptake (Optimized resin uptake range: 20.43%–22.86 wt%) 3D-printed PLA core sandwich composite and lowest performance sandwich composite (Improvement: in-plane shear strength (~34%)/modulus (~29%), out-of-plane shear strength (~25%)/modulus (~31%), specific peak bending load (~19%)). Finally, compared with balsa core sandwich composites, the 3D-printed cores are suitable for use in composite sandwich structures in many applications with a satisfactory strength-to-weight ratio.
The rapid transition toward renewable energy has introduced challenges in grid stability due to the intermittency of non-dispatchable sources like solar and wind. Industrial Demand Response (IDR) offers a promising, cost-effective solution that adjusts energy consumption patterns to align with supply, increases renewable utilization, and reduces costs. This review provides an updated analysis of IDR, sorting technologies into five categories: energy storage, scheduled energy usage, operational flexibility, on-site generation, and intelligent operations. Energy storage solutions, while requiring little flexibility, often have the longest payback periods. While slightly better, on-site generation also has longer payback periods, ranging from 5 to 20 years or more. Scheduled energy usage, operational flexibility, and intelligent operations allow significant peak reduction at lower capital costs but require greater flexibility. While 15–20 % peak reduction is within the range of all five categories, scheduled energy use and on-site energy generation are shown to have reductions of up to 70–80 % in select scenarios. Combining multiple IDR strategies from these five categories maximizes both financial and operational benefits. Synergistic approaches are shown to enhance grid stability while reducing costs. As the grid evolves, IDR will enable a more flexible, renewable-powered future that will benefit industrial facilities and the broader energy system.