Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Interferometry and holography in a low-gravity environment

The groundwork for the use of advanced optical measurement techniques in Space Shuttle materials processing in space (MPS) experiments is being laid in tests, conducted aboard a NASA KC-135 aircraft flying a parabolic trajectory, involving a Mach-Zehnder interferometer and a sideband holographic unit. The two experiments described are (1) the observation of flow during solidification, in which fluid concentration and temperature profiles were measured during unidirectional solidification of a saturated NH4Cl-H2O solution, and (2) the observation of electrodeposition flow, in which interferometry is used to provide quantitative data required in the understanding of electrochemical process transport properties. The free-floating holographic unit was operated in the microgravity environment to both test the practicality of optical systems in such conditions and test the shock and vibration characteristics of the package.

Owen, R. B.↗

S-band Network Analysis and Strategies for LEO Multi-CubeSat Science Missions

This paper presents the network architecture utilized at NASA’s Goddard Space Flight Center (GSFC) to support a mission set of five 6U CubeSats. These five CubeSats employ a multi-waveform Software Defined Radio (SDR) platform developed by Vulcan Wireless for use with NASA’s Space Relay (SR) and Direct to Earth (DTE) networks. The performance testing of the SDR is discussed via a comprehensive S-band and communication link analysis. The tested capabilities of the SDR and antenna components are reviewed in terms of the mission requirements for each CubeSat. Size Weight and Power (SWaP), required availability, and access times are discussed. The measured data from experimental compatibility testing is incorporated into detailed simulations of the CubeSat mission set to verify desired performance over the mission lifetime. The model is also used to investigate the impact of potential adverse effects on the communication links such as interference and weather conditions. This paper also reviews potential improvements from future technological advances and commercial partnerships. A collaborative investigation between GSFC and Oklahoma State University is presented in which a qualitative analysis of Hybrid RF/Optical communication strategies is performed. The data rate improvements of optical communication techniques are weighed against attitude control and science mission requirements for CubeSats, and network architectures/switching strategies are discussed. A separate analysis reviews the potential benefits of ground station partnerships, which aligns with NASA’s future goal to include commercial partners in its Earth and space network architectures, e.g. LunaNet.

Space networks↗

AE (Acoustic Emission) for Flip-Chip CGA/FCBGA Defect Detection

C-mode scanning acoustic microscopy (C-SAM) is a nondestructive inspection technique that uses ultrasound to show the internal feature of a specimen. A very high or ultra-high-frequency ultrasound passes through a specimen to produce a visible acoustic microimage (AMI) of its inner features. As ultrasound travels into a specimen, the wave is absorbed, scattered or reflected. The response is highly sensitive to the elastic properties of the materials and is especially sensitive to air gaps. This specific characteristic makes AMI the preferred method for finding "air gaps" such as delamination, cracks, voids, and porosity. C-SAM analysis, which is a type of AMI, was widely used in the past for evaluation of plastic microelectronic circuits, especially for detecting delamination of direct die bonding. With the introduction of the flip-chip die attachment in a package; its use has been expanded to nondestructive characterization of the flip-chip solder bumps and underfill. Figure 1.1 compares visual and C-SAM inspection approaches for defect detection, especially for solder joint interconnections and hidden defects. C-SAM is specifically useful for package features like internal cracks and delamination. C-SAM not only allows for the visualization of the interior features, it has the ability to produce images on layer-by-layer basis. Visual inspection; however, is only superior to C-SAM for the exposed features including solder dewetting, microcracks, and contamination. Ideally, a combination of various inspection techniques - visual, optical and SEM microscopy, C-SAM, and X-ray - need to be performed in order to assure quality at part, package, and system levels. This reports presents evaluations performed on various advanced packages/assemblies, especially the flip-chip die version of ball grid array/column grid array (BGA/CGA) using C-SAM equipment. Both external and internal equipment was used for evaluation. The outside facility provided images of the key features that could be detected using the most advanced C-SAM equipment with a skilled operator. Investigation continued using in-house equipment with its limitations. For comparison, representative X-rays of the assemblies were also gathered to show key defect detection features of these non-destructive techniques. Key images gathered and compared are: Compared the images of 2D X-ray and C-SAM for a plastic LGA assembly showing features that could be detected by either NDE technique. For this specific case, X-ray was a clear winner. Evaluated flip-chip CGA and FCBGA assemblies with and without heat sink by C-SAM. Only the FCCGA package that had no heat sink could be fully analyzed for underfill and bump quality. Cross-sectional microscopy did not revealed peripheral delamination features detected by C-SAM. Analyzed a number of fine pitch PBGA assemblies by C-SAM. Even though the internal features of the package assemblies could be detected, C-SAM was unable to detect solder joint failure at either the package or board level. Twenty times touch ups by solder iron with 700degF tip temperature, each with about 5 second duration, did not induce defects to be detected by C-SAM images. Other techniques need to be considered to induce known defects for characterization. Given NASA's emphasis on the use of microelectronic packages and assemblies and quality assurance on workmanship defect detection, understanding key features of various inspection systems that detect defects in the early stages of package and assembly is critical to developing approaches that will minimize future failures. Additional specific, tailored non-destructive inspection approaches could enable low-risk insertion of these advanced electronic packages having hidden and fine features.

Ghaffarian, Reza↗

Evaluation and study of advanced optical contamination, deposition, measurement, and removal techniques

A program is described to design, fabricate and install an experimental work chamber assembly (WCA) to provide a wide range of experimental capability. The WCA incorporates several techniques for studying the kinetics of contaminant films and their effect on optical surfaces. It incorporates the capability for depositing both optical and contaminant films on temperature-controlled samples, and for in-situ measurements of the vacuum ultraviolet reflectance. Ellipsometer optics are mounted on the chamber for film thickness determinations, and other features include access ports for radiation sources and instrumentation. Several supporting studies were conducted to define specific chamber requirements, to determine the sensitivity of the measurement techniques to be incorporated in the chamber, and to establish procedures for handling samples prior to their installation in the chamber. A bibliography and literature survey of contamination-related articles is included.

Linford, R. M. F.↗

Medicine Delivery Device with Integrated Sterilization and Detection

Sterile delivery devices can be created by integrating a medicine delivery instrument with surfaces that are coated with germicidal and anti-fouling material. This requires that a large-surface-area template be developed within a constrained volume to ensure good contact between the delivered medicine and the germicidal material. Both of these can be integrated using JPL-developed silicon nanotip or cryo-etch black silicon technologies with atomic layer deposition (ALD) coating of specific germicidal layers. The application of semiconductor processing techniques and technologies to the problems of fluid manipulation and delivery has enabled the integration of chemical, electrical, and mechanical manipulation of samples all within a single microfluidic device. This approach has been successfully applied at JPL to the automated processing, detection, and analysis of minute quantities (parts per trillion level) of biomaterials to develop instruments for in situ exploration or extraterrestrial bodies. The same nanofabrication techniques that are used to produce a microfluidics device are also capable of synthesizing extremely high-surface-area templates in precise locations, and coating those surfaces with conformal films to manipulate their surface properties. This methodology has been successfully applied at JPL to produce patterned and coated silicon nanotips (also known as black silicon) to manipulate the hydrophilicity of surfaces to direct the spreading of fluids in microdevices. JPL's ALD technique is an ideal method to produce the highly conformal coatings required for this type of application. Certain materials, such as TiO2, have germicidal and anti-fouling properties when they are illuminated with UV light. The proposed delivery device contacts medicine with this high-surface-area black silicon surface coated with a thin-film germicidal deposited conformally with ALD. The coating can also be illuminated with ultraviolet light for the purpose of sterilization or identification of the medicine itself. This constrained volume that is located immediately prior to delivery into a patient, ensures that the medicine delivery device is inherently sterile. An additional benefit to integrating a high-surface-area template within the fluid channel of a medicine delivery device is that one can envision a number of different functional coatings that could facilitate the capture and analysis of either microbial contaminants or the medicine itself. For example, one could attach antibodies or some other binding agent with a specific affinity to the silicon nanotip template. Once a target molecule or microbe is bound to the high-surface- area template, one could use an optical analytical technique such as fluorescence or adsorption to determine the identity and potentially the concentration of the species of interest. By illuminating the bound species from the back, it may also be possible to probe only the molecules with an evanescent wave, making detection of the species from the front side of the device much simpler.

Shearn, Michael J.↗

Contrails Measurement and Testing Capabilities in NASA's Particulate Aerosol Laboratory

The NASA Glenn Research Center Particulate Aerosol Laboratory (PAL) is a ground test facility for studying emissions and contrails at upper atmospheric conditions. The facility consists of a small-scale combustor that generates hot combustion gases and soot nanoparticles, which flow through a transition pipe into a jet nozzle, which exhausts into an altitude chamber. Thermodynamic conditions experienced in flight are matched in the altitude chamber, allowing the study of ice particle formation of simulated aircraft engine exhaust plumes. A non-intrusive optical diagnostic technique based on Mie scattering provides ice particle size, number density, and mass density. A suite of commercial extractive particle measurement instruments provides estimates of soot number density, size, and black carbon mass distributions. Measurements are presented for various fuels at chamber conditions covering an altitude range of 20,000 ft (6 km) to 45,000 ft (14 km) altitude and ambient temperatures from -48°C to -68°C. The data presented demonstrate the effect of soot number density, altitude, and fuel-to-air equivalence ratio on the contrail ice particle formation. Ice mass density measurements are compared to values predicted by a thermodynamic plume similarity solution.

Optical Instrumentation↗