Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical alignment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Telescope technology for the Far Ultraviolet Spectroscopic Explorer (FUSE)

Preliminary engineering studies are in progress to define a telescope for FUSE. General science objectives include high resolution spectroscopy in the 900-1200 A spectral region, low or moderate resolution spectroscopy in the 100-900 A range, and long slit imaging over a 1-arcmin field at a spatial resolution of 1 arcsec. Telescope design studies indicate that a 1-m-diameter Wolter-Schwarzschild type II glancing-incidence telescope with an effective collecting area of 3000 sq cm is required to meet the primary science objectives. A baseline optical design has been completed, and initial alignment sensitivities derived to begin the process of error allocation for the entire system.

Osantowski, J. F.↗

Mark III very long baseline interferometry positions of eight stellar systems and astrometric comparisons

Accurate positions of eight stellar systems have been obtained from Mark III VLBI observations performed with multistation arrays, and the quality of the celestial frames used by different techniques is compared. The satisfactory agreement found between VLBI and optical positions indicates that the preliminary FK5 optical frame defined by Fricke (1982) is aligned with the VLBI extragalactic reference frame. The VLBI and VLA right ascensions agree, while a large discrepancy is noted between the VLBI and VLA declinations.

Lestrade, Jean-Francois↗

UGC galaxies stronger than 25 mJy at 4.85 GHz

UGC galaxies in the declination band +5 to +75 deg were identified by position coincidence with radio sources stronger than 25 mJy on the Green Bank 4.85 GHz sky maps. Candidate identifications were confirmed or rejected with the aid of published aperture-synthesis maps and new 4.86 GHz VLA maps having 15 or 18 arcsec resolution, resulting in a sample of 347 nearby radio galaxies plus five new quasar-galaxy pairs. The radio energy sources in UGC galaxies were classified as 'starbursts' or 'monsters' on the basis of their infrared-radio flux ratios, infrared spectral indices, and radio morphologies. The rms scatter in the logarithmic infrared-radio ratio q is not more than 0.16 for starburst galaxies selected at 4.85 GHz. Radio spectral indices were obtained for nearly all of the UGC galaxies, and S0 galaxies account for a disproportionate share of the compact flat-spectrum (alpha less than 0.5) radio sources. The extended radio jets and lobes produced by monsters are preferentially, but not exclusively, aligned within about 30 deg of the optical minor axes of their host galaxies. The tendency toward minor-axis ejection appears to be independent of radio-source size and is strongest for elliptical galaxies.

Condon, J. J.↗

The precision segmented reflectors: Moderate mission figure control subsystem

A system concept for a space based segmented reflector telescope figure control subsystem is described. The concept employs a two phase architecture in which figure initialization and figure maintenance are independent functions. Figure initialization is accomplished by image sharpening using natural reference targets. Figure maintenance is performed by monitoring the relative positions and alignments of the telescope components using an optical truss. Actuation is achieved using precision positioners. Computer simulation results of figure initialization by pairwise segment coalignment/cophasing and simulated annealing are presented along with figure maintenance results using a wavefront error regulation algorithm. Both functions are shown to perform at acceptable levels for the class of submillimeter telescopes that are serving as the focus of this technology development effort. Component breadboard work as well as plans for a system testbed are discussed.

Sevaston, G.↗

Demonstration of a Monolithic Micro-Spectrometer System

The starting design of a spectrometer based on a modified Czerny-Turner configuration containing five precision surfaces encapsulated in a monolithic structure is described. Since the purpose at the early stages of the development was to demonstrate the feasibility of the technology and not an attempt to address a specific sensing problem, the first substrate material chosen was optical quality polymethyl methacrylate (PMMA). The final system design decision was narrowed down to two possible configurations containing five and six precision surfaces. The five surface design was chosen since it contained one less precision optical surface, yet included multiple off-axis spheres. In this particular design and material system, the mass was kept below 7 g. The wavelength range (bandpass) design goal was 1 micrometer (0.6 - 1.6 micrometers). The PMMA is particularly transparent in this wavelength region and there are interesting effects to monitor within this band. The optical system was designed and optimized using the ZEMAX optical design software program to be entirely alignment free (self aligning).

Rajic, S.↗

Development of a Grazing Incidence X-Ray Interferometer

A grazing incidence x-ray interferometer design capable of micro-arcsecond level resolution is discussed. This practical design employs a Michelson Stellar interferometer approach to create x-ray interference fringes without the use of Wolter style optics or diffraction crystals. Design solutions accommodating alignment, vibration, and thermal constraints are reviewed. We present the development and demonstration of a working experiment along with tolerance studies, data analysis, and results.

Shipley, Ann↗

A Micromachined Geometric Moire Interferometric Floating-Element Shear Stress Sensor

This paper presents the development of a floating-element shear stress sensor that permits the direct measurement of skin friction based on geometric Moir interferometry. The sensor was fabricated using an aligned wafer-bond/thin-back process producing optical gratings on the backside of a floating element and on the top surface of the support wafer. Experimental characterization indicates a static sensitivity of 0.26 microns/Pa, a resonant frequency of 1.7 kHz, and a noise floor of 6.2 mPa/(square root)Hz.

Horowitz, S.↗

Truss Assembly and Welding by Intelligent Precision Jigging Robots

This paper describes an Intelligent Precision Jigging Robot (IPJR) prototype that enables the precise alignment and welding of titanium space telescope optical benches. The IPJR, equipped with micron accuracy sensors and actuators, worked in tandem with a lower precision remote controlled manipulator. The combined system assembled and welded a 2 m truss from stock titanium components. The calibration of the IPJR, and the difference between the predicted and the truss dimensions as-built, identified additional sources of error that should be addressed in the next generation of IPJRs in 2D and 3D.

Komendera, Erik↗

Capacitive Edge Sensor Design for Selene Segmented Primary Mirror

The objective of this project is to produce a proof-of-concept demonstration of an edge sensor for the Space Laser Energy (SELENE) program. In the SELENE telescope, the primary mirror design sonsists of more than 200,000 segments which must be precisely aligned to correct for distortions in the optical train

SELENE↗

Robotic Sunphotometry to Enable Over-ocean Aerosol Characterization

We present developmentsforthe Sea-going Sky-Scanning Sun-tracking Advanced Research Ra-diometer(SeaSTAR), a ship-basedinstrument for aerosol characterizationover the ocean. Sun-tracking measurements of spectral solar irradiance are madein the conventional manner using filter-photodiode radiometers, and co-aligned polarizing filters are switched into the optical paths of the radiometersto measure polarized sky-radiance measurements. A robust high-performance robot with camera-feedback sun-tracking, and inertial measurement unit feed-forward motion-compensationis used for the sun-and sky-viewing modes respectively. An inverse-kinematics solver is used to point the instrument at the chosen position relative to the sunand ensure that the polarizer axis remains in the desired orientation, allowing the Stokes vector components of the sky radiance to be resolved by rotating the measurement barrel about a third robot axis. SeaSTAR aims to provide a resource for cost-effective validation of aerosol property measurements over the oceans in support of satellite missions such as PACE, SBG and GLIMR.

Robotic↗

Optical Testing of Diamond Machined, Aspheric Mirrors for Groundbased, Near-IR Astronomy

The Infrared Multi-Object Spectrometer (IRMOS) is a facility-class instrument for the Kitt Peak National Observatory 4 and 2.1 meter telescopes. IRMOS is a near-IR (0.8-2.5 micron) spectrometer and operates at approximately 80 K. The 6061-T651 aluminum bench and mirrors constitute an athermal design. The instrument produces simultaneous spectra at low- to mid-resolving power (R=lambda/delta lambda= 300-3000) of approximately 100 objects in its 2.8 x 2.0 arcmin field. We describe ambient and cryogenic optical testing of the IRMOS mirrors across a broad range in spatial frequency (figure error, mid-frequency error, and microroughness). The mirrors include three rotationally symmetric, off-axis conic sections, one off-axis biconic, and several flat fold mirrors. The symmetric mirrors include convex and concave prolate and oblate ellipsoids. They range in aperture from 94x86 mm to 286x269 mm and in f-number from 0.9 to 2.4. The biconic mirror is concave and has a 94x76 mm aperture, R(sub x)=377 mm, k(sub x)=0.0778, R(sub y)=407 mm, and k(sub y)=0.1265 and is decentered by -2 mm in X and 227 mm in Y. All of the mirrors have an aspect ratio of approximately 6:1. The surface error fabrication tolerances are less than 10 nm RMS microroughness, 'best effort' for mid-frequency error, and less than 63.3 nm RMS figure error. Ambient temperature (approximately 293 K) testing is performed for each of the three surface error regimes, and figure testing is also performed at approximately 80 K. Operation of the ADE Phaseshift MicroXAM white light interferometer (micro-roughness) and the Bauer Model 200 profilometer (mid-frequency error) is described. Both the sag and conic values of the aspheric mirrors make these tests challenging. Figure testing is performed using a Zygo GPI interferometer, custom computer generated holograms (CGH), and optomechanical alignment fiducials. Cryogenic CGH null testing is discussed in detail. We discuss complications such as the change in prescription with temperature and thermal gradients. Correction for the effect of the dewar window is also covered. We discuss the error budget for the optical test and alignment procedure. Data reduction is accomplished using commercial optical design and data analysis software packages. Results from CGH testing at cryogenic temperatures are encouraging thus far.

Chambers, V. John↗

Remote Recession Sensing of Ablative Heat Shield Materials

Material recession and charring are two major processes determining the performance of ablative heat shield materials. Even in ground testing, the characterization of these two mechanisms relies on measurements of material thickness before and after testing, thus providing only information integrated over the test time. For recession measurements, optical methods such as imaging the sample surface during testing are under investigation but require high alignment and instrument effort, therefore being not established as a standard measurement method. For char depth measurements, the most common method so far consists in investigation of sectioned samples after testing or in the case of Stardust where core extractions were performed to determine char information. In flight, no reliable recession measurements are available, except total recession after recovering the heat shield on ground. Developments of mechanical recession sensors have been started but require substantial on board instrumentation adding mass and complexity. In this work, preliminary experiments to evaluate the feasibility of remote sensing of material recession and possibly char depth through optically observing the emission signatures of seeding materials in the post shock plasma is investigated. It is shown that this method can provide time resolved recession measurements without the necessity of accurate alignment procedures of the optical set-up and without any instrumentation on board of a spacecraft. Furthermore, recession data can be obtained without recovering flight hardware which would be a huge benefit for inexpensive heat shield material testing on board of small re-entry probes, e.g. on new micro-satellite re-entry probes as a possible future application of Cubesats or RBR

instrumentation↗

The Nuclear Spectroscopic Telescope Array (NuSTAR)

The Nuclear Spectroscopic Telescope Array (NuSTAR) is a NASA Small Explorer mission that will carry the first focusing hard X-ray (5 - 80 keV) telescope to orbit. NuSTAR will offer a factor 50 - 100 sensitivity improvement compared to previous collimated or coded mask imagers that have operated in this energy band. In addition, NuSTAR provides sub-arcminute imaging with good spectral resolution over a 12-arcminute field of view. After launch, NuSTAR will carry out a two-year primary science mission that focuses on four key programs: studying the evolution of massive black holes through surveys carried out in fields with excellent multiwavelength coverage, understanding the population of compact objects and the nature of the massive black hole in the center of the Milky Way, constraining explosion dynamics and nucleosynthesis in supernovae, and probing the nature of particle acceleration in relativistic jets in active galactic nuclei. A number of additional observations will be included in the primary mission, and a. guest observer program will be proposed for an extended mission to expand the range of scientific targets. The payload consists of two co-aligned depth-graded multilayer coated grazing incidence optics focused onto solid state CdZnTe pixel detectors. To be launched in early 2012 on a Pegasus rocket into a low-inclination Earth orbit. NuSTAR largely avoids SAA passages, and will therefore have low and stable detector backgrounds. The telescope achieves a 10.15-meter focal length through on-orbit deployment of all mast. An aspect and alignment metrology system enable reconstruction of the absolute aspect and variations in the telescope alignment resulting from mast flexure during ground data processing. Data will be publicly available at GSFC's High Energy Astrophysics Science Archive Research Center (HEASARC) following validation at the science operations center located at Caltech.

Harrison, Fiona A.↗

Development of microchannel plate x-ray optics

The goal of this research program was to develop a novel technique for focusing x-rays based on the optical system of a lobster's eye. A lobster eye employs many closely packed reflecting surfaces arranged within a spherical or cylindrical shell. These optics have two unique properties: they have unlimited fields of view and can be manufactured via replication of identical structures. Because the angular resolution is given by the ratio of the size of the individual optical elements to the focal length, optical elements with sizes on the order of one hundred microns are required to achieve good angular resolution with a compact telescope. We employed anisotropic etching of single crystal silicon wafers for the fabrication of micron-scale optical elements. This technique, commonly referred to as silicon micromachining, is based on silicon fabrication techniques developed by the microelectronics industry. An anisotropic etchant is a chemical which etches certain silicon crystal planes much more rapidly than others. Using wafers in which the slowly etched crystal planes are aligned perpendicularly to the wafer surface, it is possible to etch a pattern completely through a wafer with very little distortion. Our optics consist of rectangular pores etched completely through group of zone axes (110) oriented silicon wafers. The larger surfaces of the pores (the mirror elements) were aligned with the group of zone axes (111) planes of the crystal perpendicular to the wafer surface. We have succeeded in producing silicon lenses with a geometry suitable for 1-d focusing x-ray optics. These lenses have an aspect ratio (40:1) suitable for x-ray reflection and have very good optical surface alignment. We have developed a number of process refinements which improved the quality of the lens geometry and the repeatability of the etch process. A significant progress was made in obtaining good optical surface quality. The RMS roughness was decreased from 110 A for our initial lenses to 30 A in the final lenses. A further factor of three improvement in surface quality is required for the production of efficient x-ray optics. In addition to the silicon fabrication, an x-ray beam line was constructed at Columbia for testing the optics.

Kaaret, Philip↗

MACOS Version 3.31

Version 3.31 of Modeling and Analysis for Controlled Optical Systems (MACOS) has been released. MACOS is an easy-to-use computer program for modeling and analyzing the behaviors of a variety of optical systems, including systems that have large, segmented apertures and are aligned with the technology of wavefront sensing and control. Two previous versions were described in "Improved Software for Modeling Controlled Optical Systems" (NPO-19841) NASA Tech Briefs, Vol. 21, No. 12 (December 1997), page 42 and "Optics Program Modified for Multithreaded Parallel Computing" (NPO-40572) NASA Tech Briefs, Vol. 30, No. 1 (January 2006) page 13a. The present version incorporates the following enhancements over prior versions: a) A powerful system-optimization facility includes algorithms for linear, nonlinear, unconstrained, and constrained optimization of optical systems under a variety of settings. b) There is now enhanced capability to perturb optical components individually and on subsystem levels, and to optimize system performance by adjusting selected individual components as well as subsystems. c) Capabilities for modeling a variety of new optical aperture types have been added. d) Effects of multilayer thin-film coats on optical surfaces can now be taken into account when tracing polarized rays. e) Major software-engineering work was performed to make MACOS more reliable, flexible, and manageable for purposes of maintenance and further development.

Redding, David↗

Estimation, UQ, and Sensitivity Analysis for a New Diagnostic Setup [Slides]

This is for an early career talk I am giving at the Association for Women in Math’s Research Symposium. It provides a general overview of three projects: the first focuses on velocity measurements from optical laser diagnostics, the second focuses on probe alignment and location (metrology), and the third is my Site-Directed Research and Development (SDRD) which focuses on neural networks for image datasets. All three projects have strong uncertainty quantification components.

97 MATHEMATICS AND COMPUTING↗

A Fiber-Optic Coupled Telescope for Water Vapor DIAL Receivers

A fiber-optic coupled telescope of low complexity was constructed and tested. The major loss mechanisms of the optical system have been characterized. Light collected by the receiver mirror is focused onto an optical fiber, and the output of the fiber is filtered by an interference filter and then focused onto an APD detector. This system was used in lidar field measurements with a 532-nm Nd:YAG laser beam. The results were encouraging. A numerical model used for calculation of the expected return signal agreed with the lidar return signal obtained. The assembled system was easy to align and operate and weighed about 8 kg for a 30 cm (12") mirror system. This weight is low enough to allow mounting of the fiber-optic telescope receiver system in a UAV. Furthermore, the good agreement between the numerical lidar model and the performance of the actual receiver system, suggests that this model may be used for estimation of the performance of this and other lidar systems in the future. Such telescopes are relatively easy to construct and align. The fiber optic cable allows easy placement of the optical detector in any position. These telescope systems should find widespread use in aircraft and space home DIAL water vapor receiver systems.

DeYoung, Russell J.↗

Laser Light Scattering with Multiple Scattering Suppression Used to Measure Particle Sizes

Laser light scattering is the technique of choice for noninvasively sizing particles in a fluid. The members of the Advanced Technology Development (ATD) project in laser light scattering at the NASA Lewis Research Center have invented, tested, and recently enhanced a simple and elegant way to extend the concentration range of this standard laboratory particle-sizing technique by several orders of magnitude. With this technique, particles from 3 nm to 3 mm can be measured in a solution. Recently, laser light scattering evolved to successfully size particles in both clear solutions and concentrated milky-white solutions. The enhanced technique uses the property of light that causes it to form tall interference patterns at right angles to the scattering plane (perpendicular to the laser beam) when it is scattered from a narrow laser beam. Such multiple-scattered light forms a broad fuzzy halo around the focused beam, which, in turn, forms short interference patterns. By placing two fiber optics on top of each other and perpendicular to the laser beam (see the drawing), and then cross-correlating the signals they produce, only the tall interference patterns formed by singly scattered light are detected. To restate this, unless the two fiber optics see the same interference pattern, the scattered light is not incorporated into the signal. With this technique, only singly scattered light is seen (multiple-scattered light is rejected) because only singly scattered light has an interference pattern tall enough to span both of the fiber-optic pickups. This technique is simple to use, easy to align, and works at any angle. Placing a vertical slit in front of the signal collection fibers enhanced this approach. The slit serves as an optical mask, and it significantly shortens the time needed to collect good data by selectively masking out much of the unwanted light before cross-correlation is applied.

Meyer, William V.↗