Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “operator complexity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Heat Integration Optimization and Dynamic Modeling Investigation for Advancing the Coal-Direct Chemical Looping Process

The purpose of the project is to address the optimization and startup operation of a modular coal direct chemical looping (CDCL) combustion system integrated with a steam cycle for power generation to reduce the risks involved in further scale-up of the technology. The modular reactor design of the CDCL process provides flexibility in the fabrication of the reactor and in its operating capacity (i.e. turndown ratio) at the cost of a more complex heat exchange network (HEN) design and integration. To address the technology gaps and advance the efficiency and economic feasibility of the CDCL technology, the project will perform a detailed and comprehensive analysis of the integration of a modular CDCL reactor system and a steam cycle system under both static and transient conditions via HEN process performance simulations and system dynamic modeling, respectively. The scope of work consists of 1) Experimental and computational studies of the CDCL combustor reactor 2) Comprehensive static (i.e. steady-state) system HEN design analysis in CDCL 550 MWe commercial unit for power generation and 3) Dynamic modeling of site specific design of 10MWe CDCL large pilot plant. The project team has successfully developed and validated a kinetic model for the oxidation of oxygen carriers in the combustor using the unreacted shrinking core model (UCSM). The model is capable of capturing the oxidation kinetics of fully or partially reduced oxygen carrier particles. A computational fluid dynamics (CFD) model is developed to simulate the hydrodynamics, heat transfer, and chemical reaction occurring in the CDCL combustor. The model is developed in MFIX and ANSYS Fluent. Key aspects of CDCL combustor operation, including heat transfer, oxygen carrier oxidation, and the transport of oxygen carrier particles, are simulated using this CFD model. The HEN for a commercial scale 550 MWe CDCL power plant is simulated and optimized using ASPEN Plus. Practical design considerations are incorporated based on industrial experiences. The performance and cost for the commercial CDCL plant is updated based on these analyses. A dynamic model for the 10 MWe CDCL pilot plant is developed in ProTRAX simulation software. The model is based on the pilot plant design developed in project DE-FE0027654 “10 MWe CDCL Large Pilot Plang – Pre-FEED Study” and the steam cycle data obtained from Dover Light & Power plant. The transient behaviors during pilot plant load variation are simulated using the dynamic model.

01 COAL, LIGNITE, AND PEAT↗

Emulator of PR‐DNS: Accelerating Dynamical Fields With Neural Operators in Particle‐Resolved Direct Numerical Simulation

Abstract Particle‐resolved direct numerical simulations (PR‐DNS) play an increasing role in investigating aerosol‐cloud‐turbulence interactions at the most fundamental level of processes. However, the high computational cost associated with high resolution simulations poses considerable challenges for large domain or long duration simulation using PR‐DNS. To address these issues, here we present an emulator of the complex physics‐based PR‐DNS developed by use of the data‐driven Fourier Neural Operator (FNO) method. The effectiveness of the method is showcased by presenting turbulence and temperature fields in a two‐dimensional space. The results demonstrate high accuracy at various resolutions and the emulator is two orders of magnitude cheaper in terms of computational demand compared to the physics‐based PR‐DNS model. Furthermore, the FNO emulator exhibits strong generalization capabilities for different initial conditions and ultra‐high‐resolution without the need to retrain models. These findings highlight the potential of the FNO method as a promising tool to simulate complex fluid dynamics problems with high accuracy, computational efficiency, and generalization capabilities, enhancing our understanding of the aerosol‐cloud‐precipitation system.

99 GENERAL AND MISCELLANEOUS↗

Energy Sector Threat Brief: 2024 Round Up

What major and minor cybersecurity events affected the energy sector in the last year? What trends were observed in the events, disclosure of vulnerabilities, and other headline news? This talk will focus on real-world events put in the context of an evolving geo-political landscape. We will discuss events that had operational impact as well as events affecting third-parties with exploration of how the impact of incidents is changing as more stakeholders are involved in new projects and the complexity of the modern grid. We will focus on lessons learned from the 2024 trends that operators and their partners can apply to stay ahead of the threats in 2025.

14 - SOLAR ENERGY↗

Distributed Optimization Approaches with Discrete Variables in the Power Distribution Systems

Traditionally, centralized approaches have predominantly been used for the power system operation and control. With increasing penetration of small-scale distributed energy resources (DERs) in the distribution network, especially independently owned renewable resources, distributed algorithms can serve as a potential alternative for improving scalability, resiliency and addressing privacy concerns. However, the complexity of distributed algorithms significantly increases with the integration of the legacy devices, the operation of which depend on discrete control variables. This paper aims to provide a review of the distributed optimization algorithms incorporating discrete control variables for the power distribution system. While the research in this domain is still at its nascence, an extensive comparison of the approaches in the literature for applying quadratic penalty, branch and bound,ordinal optimization and proximal operator to handle discrete variables in the framework of ADMM and dual decomposition have been addressed. Future research direction in this field have been also provided.

Adan, Jannatul↗

Impact of Fill Factor on Electro-slag Remelting Operations

Vacuum induction melting (VIM), electro-slag remelting (ESR) and vacuum arc remelting (VAR) are all techniques used to make high quality ingots of complex chemistries. In some cases, all three are used, e.g., alloys for aerospace applications and increasingly those for fossil power applications under extreme conditions. Electroslag remelting operation is a complicated endeavor, dependent upon several factors including operating current, voltage, and geometry. A research scale 440 lb capacity ESR furnace was used to melt low carbon steel (1018 steel) electrodes of different diameters using various melt rates. This was used to assess melt parameters and sidewall and other quality aspects of the product ingots. These observations were compared to results from ESR modeling using MeltFlow-ESR. It was found that fill factor had a significant impact on operating voltage while current had a significant impact on melt rate. Ultimately, a combination of fill factor and power gave the best prediction of melt rate during steady state.

Jablonski, Paul↗

A finite difference informed random walker (FDiRW) solver for strongly inhomogeneous diffusion problems

In nature, many complex multi-physics coupling problems exhibit strong diffusivity inhomogeneity. For instance, in the context of radionuclide absorption by porous wasteform materials within a flowing waste stream, the difference of species’ diffusivity in solid and liquid phases spans by 3~8 orders of magnitude. To solve the diffusion equations with strongly inhomogeneous diffusivity, traditional discretization-based methods, such as the Finite Difference Method (FDM), require infinitesimally small time steps (<10 -10 ) as high spatial resolutions are employed in most microstructure evolution processes, leading to prohibitively high computational costs. Here, this work developed an integrated numerical approach (FDiRW: Finite Difference informed Random Walk) to tackle this challenge. The idea is that utilizing the Random Walk concept, the fast diffusion is modeled as a superposition of point source’s solution for a concentration distribution while FDM is used to obtain the point source’s solution at each node. A mesh-coarsening algorithm is developed to generate an exclusive coarse mesh for FDiRW approach to maximize its efficiency. The effectiveness of the coarse mesh-based FDiRW approach is validated by benchmarking Finite Difference solutions. Numerical results demonstrated that FDiRW achieves a remarkable 1000x computational efficiency improvement over FDM while preserving desired accuracy for a medium-sized model of 192 × 192 × 192 grids. Finally, as models scale up, a floating-point operations (PLOPs) analysis of the FDiRW algorithm reveals that its computational complexity grows quadratically in terms of the number of nodes employed in computation.

36 MATERIALS SCIENCE↗

Lowering tomography costs in quantum simulation with a symmetry projected operator basis

Measurement in quantum simulations provides a means for extracting meaningful information from a complex quantum state, and for quantum computing, reducing the complexity of measurement will be vital for near-term applications. For most quantum simulations, the targeted state will obey several symmetries inherent to the system Hamiltonian. Here, we obtain an alternative symmetry projected basis of measurement that reduces the number of measurements needed by a constant factor. Our scheme can be implemented at no additional cost on a quantum computer, can be implemented under various measurement or tomography schemes, and is reasonably resilient under noise.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Document Management: A Focused Analysis on the Configuration Management Process at Y-12 National Security Complex

The configuration management process at Y-12 is a crucial process to ensure safe operations and compliance with Department of Energy (DOE) regulations and requirements. This process is evaluated utilizing systems-thinking methodology in order to understand the current operational flow, with the ultimate goal of building an easily understandable, representative model. This model offers insights on key areas of waste and provides a potential solution by modernizing rate limiting steps: a software implementation to update the traditional document management system and make it paperless. Stakeholders of the software implementation are identified in order to define characteristic requirements of an effective product and the anticipated benefit is evaluated. Ultimately, this project is an effort to increase the quality of life for all stakeholders, while improving the capacity, throughput, and effectiveness of a necessary process at Y-12.

42 ENGINEERING↗

Digital Twin Technology (“Morpheus”) for Optimized Building Operations [SWR-22-74]

The electrification of buildings is an important step to reducing greenhouse gas emissions across all industries. The management of increasingly electrified buildings is a complex pursuit, and there remains a need for cost-effective software capable of handling the computational burden required of such complexity. Through a partnership with Dallas Fort Worth (DFW) Airport, researchers at NREL have developed a digital twin modeling framework to optimize building operations, called Morpheus. Pairing predictive control with automatic fault detection and diagnostics, Morpheus decreases energy expenditures, costs, and faults for large facilities. Additionally, Morpheus employs artificial intelligence to continuously improve its performance using information provided by sensor systems, human experts with deep industry domain knowledge, and even from other similar machines or fleets of machines. Coupling this novel energy-management software with other digital twins, such as NREL’s Athena software for mobility operations, enables robust decision-making for asset and space management. The implementation of Morpheus at DFW has resulted in significantly improved HVAC system operations and reduced both peak power and overall energy consumption. This enhanced functionality comes at a more affordable price than previously developed digital twins and can be customized for other facilities’ geometries to provide optimal, individualized control of a facility’s energy consumption.

Chinde, Venkatesh↗

Nickel Interlayer for Improved Silver Complex Inks Metallization in GaAs Photovoltaic Devices

Large areas of III-V photovoltaic panels are essential to supplying operational energy for a growing demand of satellites of strategic importance to the United States military, covering a range of applications. High fabrication costs and low manufacturing throughput are key barriers to meeting the necessary supply, which can in turn jeopardize mission success. At the device level, metallization based on printing of complex metal inks has attracted significant research interest due to its potential to substantially reduce processing costs and increase throughput while achieving electrical performance comparable to those of conventional metallization schemes. For GaAs photovoltaic devices, however, reliable electrical contacting remains challenging due to the formation of an interfacial oxide layer at the metal-semiconductor interface. This oxide barrier severely limits current extraction from the PV absorber, resulting in unacceptably high contact resistance. In this study, we report the introduction of a reactive nickel (Ni) interfacial layer between the silver metal fingers and the GaAs substrate to suppress oxide formation while maintaining a low-resistance electrical interface, and show performance data from fully fabricated GaAs devices incorporating the Ni interlayer. These results demonstrate the potential of reactive Ni ink as an effective interfacial layer for improved electrical contacting in low-cost PV metallization schemes.

14 SOLAR ENERGY↗

Final Report for Closing the Loop Between In Situ Stress Complexity and EGS Fracture Complexity

Characterizing in situ stress is essential in Enhanced Geothermal System (EGS) for both risk assessment and operation design. Standard stress measurement techniques such as diagnostic fracture injection tests (DFITs) require creating hydraulic fractures and apply analytical methods such as the G -function analysis to estimate the stress. These classical approaches rely on several assumptions, including but not limited to: (i) the induced fracture is planar and persistent, and (ii) the fracture plane is normal to the minimum horizontal stress. However, these assumptions may not hold in EGS environments like Utah FORGE, where thermo-hydro-mechanical (THM) coupling, wellbore deviation, and rock heterogeneity can alter the local stress condition and consequently lead to fracture complexities in both near-well and far-field regions.

15 GEOTHERMAL ENERGY↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Tomographic optical emission spectroscopy of an atmospheric pressure plasma jet and surface ionization waves on planar and structured surfaces

Here in this paper, an approach for 3D plasma structure diagnostics using tomographic optical emission spectroscopy (Tomo-OES) of a nanosecond pulsed atmospheric pressure plasma jet (APPJ) is presented. In contrast to the well-known Abel inversion, Tomo-OES does not require cylindrical symmetry to recover 3D distributions of plasma light emission. Instead, many 2D angular projections are measured with intensified cameras and the multiplicative algebraic reconstruction technique is used to recover the 3D distribution of light emission. This approach solves the line-of-sight integration problem inherent to optical diagnostics, allowing recovery of localized OES information within the plasma that can be used to better infer plasma parameters within complex plasma structures. Here, Tomo-OES was applied to investigate an APPJ operated with helium in ambient air and impinging on planar and structured dielectric surfaces. Surface charging caused the guided streamer from the APPJ to transition to a surface ionization wave (SIW) that propagated along the surface. The SIW experienced variable geometrical and electrical material properties as it propagated, leading to 3D configurations that were non-symmetric and spatially complex. Light emission from He, N$_2^+$, and N2 were imaged at ten angular projections and the respective time-resolved 3D emission distributions in the plasma were then reconstructed. The spatial resolution of each tomographic reconstruction was 7.4 µm and the temporal resolution was 5 ns, sufficient to observe the guided streamer and the effects of the structured surface on the SIW. Emission from He showed the core of the jet and emission from N$_2^+$ and N2 indicated effects of entrainment of ambient air. Penning ionization of N2 created a ring or outer layer of N$_2^+$ that spatially converged to form the 'plasma bullet' or spatially diverged across a surface as part of a SIW. The SIW entered trenches of size 150 µm, leading to decreases in plasma light emission in regions above the trenches. The plasma light emission was higher in some regions with trenches, possibly due to effects of field enhancement.

plasma interactions with complex surfaces↗

Modeling the Fundamental Radiation Chemistry of the Organic Diluent, and the Effect of Metal Ion Complexation on the Radiochemical Behavior of Active Compounds

All used nuclear fuel (UNF) reprocessing technologies must operate efficiently in the presence of an intense, multi-component (predominantly alpha, beta, and gamma) radiation field. Consequently, radiation-induced degradation of reprocessing systems is of concern, as it negatively impacts process performance over time due to the destruction of both active compounds (ligands, phase modifiers, holdback agents, etc.) and the formation of degradation products. Reprocessing solvent system radiolysis has been linked to changes in separation efficiency and physical properties of solvent mixtures, solvent-recycle longevity, crud formation, and other unexpected outcomes that impact the efficient recovery of valuable materials (e.g., the actinides) and the volume of hazardous radioactive waste for final disposal, i.e., in a geological repository. Consequently, a fundamental understanding of radiolytic processes and their effects on reprocessing solvent system performance is critical for: (i) the cost-effective development and innovation of separation technologies; (ii) the design and implementation of predictive radiation chemical models for process monitoring and lifetimes; and (iii) potentially the ability to exploit radiolytic phenomenon to our benefit, e.g., strategic radiolysis of active molecules to liberate specific degradation products that aid subsequent process stages. Despite extensive investigation into the radiolytic behavior of active solvent system compounds, little attention has been given to understanding (i) the radiation chemical behavior and modification of the organic diluent and (ii) the effect of metal ion complexation on the radiochemical behavior of active compounds.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Electrorefiner Speciation and Phase Model for Prediction of Operation Lifetime

The Mk IV electrorefiner (ER) at Idaho National Laboratory has recovered uranium metal from used nuclear fuels for 27 years. Thus, large quantities of fission product chlorides more electropositive than uranium have accumulated in the ER salt, increasing the complexity of phase equilibria and salt speciation. Importantly, the melt temperature of the salt increases with ER operation and will ultimately exceed design limits without intervention. Methods to remove fission products from molten chloride salt are known, but their implementation at scale is not yet demonstrated. In this work, historical ER composition and differential scanning calorimetry (DSC) are utilized to develop coupled speciation and chloride salt solution thermochemistry models, which enable accurate present-day analysis of ER salt as well as forecast its future disposition. The developed thermochemical models are applicable to chloride salts generally and have been made available in the Molten Salt Thermal Properties Database – Thermochemical.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Addressing Consequence within Operational Risk (O.T. Gagnon III) 9-18-2024

Addressing Consequence within Operational Risk: Why threats and security are just not that important! When dealing with cyber or physical risk within any critical infrastructure (CI) environment, don’t concern yourself with vulnerabilities and threats, at least not at first! Also, don’t be overly fixated on “securing the systems” within the organization. The endeavor of tackling operational risk focused on consequences in any critical infrastructure environment to include the complex Aviation ecosystem is challenging even for the most resourced entity but can be advanced though a simplified approach: identifying, binning, and prioritizing the infrastructure environment. While no two entities within a single element of the 16 critical infrastructure sectors are exactly alike when it comes to risk, there is a basic process to move toward a greater understanding of operational risk through becoming more informed about the infrastructure environment in which the entity exists. The process starts with bringing internal and external stakeholders and subject matter experts together to analyze key areas such as Information Technology (IT) and Operational Technology (OT) components and points of convergence, analyzing internal and external cyber and physical dependencies, accounting for explosive growth in devices and wireless technology, and leveraging the contributions of people inside and outside the operational environment. Attaining a common understanding of the infrastructure environment as part of addressing consequences within operational risk is not easy to do or resource light, but the process outlined provides the framework to further any entity’s efforts in this space. When it comes to cyber risks, before an organization can consider vulnerabilities within and threats to its operations, it must first have a solid understanding of the consequences existing inside its infrastructure environment. Idaho National Lab’s Consequence-Driven, Cyber-Informed Engineering is offered as an example of this approach to effective and efficient cyber risk mitigation.

99 GENERAL AND MISCELLANEOUS↗

VoroClust

SAND2025-11465O VoroClust, also known as Voronoi Clustering, is a fast, density-based unsupervised clustering algorithm applicable to high-resolution and high-dimensional data. It operates as quickly as distance-based clustering methods while effectively capturing complex regional geometries, matching the performance of current density-based methods. VoroClust employs a data-centered sphere cover to reduce computational demands while preserving data topology. It propagates clusters outward from local density peaks. Although supervised machine learning is powerful for applications like image classification and segmentation, it requires comprehensive, consistent datasets, which many applications lack. Unsupervised clustering algorithms analyze the structure of each dataset rather than relying on similarities with other examples, making them well-suited for practical applications with insufficient or inappropriate data for supervised learning. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Ebeida, Mohamed [Sandia National Lab. (SNL-CA), Li↗