SEARCH · Engineering Papers
Results for “nuclear detection”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
NSDD Partnership Working Together to Prevent Nuclear Trafficking
NSDD partnership working together to prevent nuclear trafficking. Supported by the office of Nuclear Smuggling Detection and Deterrence.
Man-Portable Dense Plasma Focus for Neutron Interrogation Application, NLV-009-17, Year 1 of 2
Presentation described project to develop man-portable device for detection of nuclear material using dense plasma focus technology.
Performance Targets for Detection and Investigation of Undeclared Nuclear Activities in the State as a Whole
Explore the source record for details and available documents.
Development of eXternal Nuclear Reaction Analysis (X NRA) Detection Technique for Quantifying Light Isotope Concentrations.
Abstract not provided.
Re-Purposing Old Seismic Data to Calibrate Nuclear Test Monitoring Sites in Sparse Seismic Regions
Explore the source record for details and available documents.
Effects of 4-phenylbutyric acid on the process and development of diabetic nephropathy induced in rats by streptozotocin: Regulation of endoplasmic reticulum stress-oxidative activation
Oxidative stress may contribute to the pathogenesis of diabetic nephropathy (DN), although the precise regulatory mechanism is still unclear. Recent reports have shown that chemical molecular chaperone 4-phenylbutyric acid (4-PBA) can suppress oxidative stress by attenuating endoplasmic reticulum (ER) stress. We therefore hypothesized that 4-PBA could provide renoprotection through the suppression of oxidative stress in DN rats. Male Sprague-Dawley (SD) rats were randomly divided into three groups: a normal control (NC) group, a streptozotocin (STZ)-induced DN model group, and a DN plus 4-PBA (1 g/kg) treatment group. At the end of 4, 8, and 12 weeks, hydroxyproline content, NADPH oxidase activity and the expression of phosphorylation of inositol-requiring enzyme-1{alpha} (p-IRE1{alpha}), p47phox, nitrotyrosine (NT) and NF-E2-related factor 2 (Nrf2) in the kidneys of all rats were determined; malondialdehyde (MDA) levels and superoxide dismutase (SOD) activity in serum and urine were also detected; renal nuclear factor {kappa}B (NF-{kappa}B) activity in all of the rats was examined at the end of 12 weeks. Compared with the NC group, the DN rats showed a significant increase in hydroxyproline content, NADPH oxidase activity, NF-{kappa}B activity, the expression of p-IRE1{alpha}, p47phox, NT and Nrf2 in renal tissue; markedly, MDA levels were higher and SOD activity was lower in serum and urine of DN rats than in NC rats for the indicated time. These alterations were inhibited by the administration of 4-PBA. These findings first demonstrated that treatment with 4-PBA significantly inhibits the process and development of diabetic nephropathy in rats through the regulation of ER stress-oxidative activation.
Bremstrahlung versus Monoenergetic Photons for Photonuclear Inspection Applications
Bremsstrahlung sources have been utilized for various non-intrusive inspection or interrogation applications for over 100 years - with the primary focus being radiographic imaging. In the last several decades, it has become evident that photons of energy greater than 6 MeV can also provide useful photonuclear information that can extend the capabilities and information available from active inspections. These energetic inspection photons can be produced as a continuum of energies (i.e., bremsstrahlung distribution) or as a set of one or more discrete photon energies (i.e., monoenergetic distribution). This paper will discuss the photonuclear process and its energetic photon energy dependence, will discuss the photonuclear role in nuclear material detection, will present applicable photon sources along with their field deployment status, and highlight some advantages and disadvantages of bremsstrahlung and monoenergetic photons sources.
Projected network performance for next-generation xenon monitoring systems
Next-generation radioxenon monitoring systems are reaching maturity and are expected to improve certain aspects of performance in verifying the absence of nuclear tests. To predict the improvement in detecting and locating nuclear releases, thousands of releases all over the globe were simulated and the global detection probability was calculated. This was done for the International Monitoring System network of noble gas samplers as it currently exists (25 certified stations), and how it would be for potential future network sizes of 39 and 79 stations. The probability of detection was calculated for releases ranging from 10 10 Bq to 10 16 Bq of 133 Xe and presented as coverage maps and global integrals for both current and next-generation monitoring systems. Similarly, the number of detecting stations and the number of detecting samples were tabulated to elucidate the possibilities for enhanced location capability. Improvements in global detection coverage are maximized at different release sizes in a way that depends on the station density. For example, for releases of 3×10 14 Bq and 39 stations, the detection probability would rise from 60% to 70% with next-generation systems, while for releases of 10 13 Bq and 79 stations, it would rise from 37% to 52%. Achieving an average of two detecting stations requires a 1015 Bq release for a 39-station network and a 10 14 Bq release for a 79-station network. The largest impact of using next-generation systems may be the confidence, failure tolerance, and location capability that arise from obtaining multiple samples associated with a single release event.
Single-Volume Neutron Scatter Camera for High-Efficiency Neutron Imaging and Source Characterization. Year 2 of 3 Summary
The neutron scatter camera (NSC), an imaging spectrometer for fission energy neutrons, is an established and proven detector for nuclear security applications such as weak source detection of special nuclear material (SNM), arms control treaty verification, and emergency response. Relative to competing technologies such as coded aperture imaging, time-encoded imaging, neutron time projection chamber, and various thermal neutron imagers, the NSC provides excellent event-by-event directional information for signal/background discrimination, reasonable imaging resolution, and good energy resolution. Its primary drawback is very low detection efficiency due to the requirement for neutron elastic scatters in two detector cells. We will develop a singlevolume double-scatter neutron imager, in which both neutron scatters can occur in the same large active volume. If successful, the efficiency will be dramatically increased over the current NSC cell-based geometry. If the detection efficiency approaches that of e.g. coded aperture imaging, the other inherent advantages of double-scatter imaging would make it the most attractive fast neutron detector for a wide range of security applications.
Radioactive Contraband Detection: A Bayesian Approach
Radionuclide emissions from nuclear contraband challenge both detection and measurement technologies to capture and record each event. The development of a sequential Bayesian processor incorporating both the physics of gamma-ray emissions and the measurement of photon energies offers a physics-based approach to attack this challenging problem. It is shown that a 'physics-based' structure can be used to develop an effective detection technique, but also motivates the implementation of this approach using or particle filters to enhance and extract the required information.
A CZT-based radioxenon detection system in support of the Comprehensive Nuclear-Test-Ban Treaty
Here in this work, a prototype radioxenon detection system was designed, developed and tested at Oregon State University to study the response of CdZnTe (CZT) detectors to xenon radioisotopes for monitoring nuclear explosions. The detector utilizes two coplanar CZT detectors and measures xenon radioisotopes through beta-gamma coincidence detection between the two detection elements. The CZT-based detection system offers excellent energy resolution and background count rate compared with scintillator-based beta-gamma coincidence detectors currently in operation at the IMS stations. In this paper, we briefly discuss the detector design and report our recent measurement results with 131mXe, 133mXe, and 133Xe produced in the TRIGA reactor at OSU.
Application of Triple Coincidence for the Detection of Small Amounts of Special Nuclear Materials
We constructed a device that measures two {gamma}-rays and one neutron from spontaneous fission and any resulting multiplication chains. It extends the associated particle technique based upon correlated counting of the multiplicity of gamma-rays and neutrons released in spontaneous- or neutron-induced fission. There are two advantages in incorporating a third detector in the design over the standard two-detector version. First, we found that random uncorrelated events dominate the background of coincident counting with a gamma-ray- and neutron-detector. These might be suppressed by requiring an additional coincidence. Second, the time history of gamma-ray emission between the two gamma-ray detectors is related to multiplication in the target media. Multiplication in highly enriched uranium is much greater than in depleted uranium.
Digital Autoradiography as a novel complementary technique for the investigation of radioactive contamination in nuclear facilities under dismantlement
The detection (location and quantification) of nuclear facilities to be dismantled possible contamination with low-range particles emitters ({sup 3}H, other low-energy β emitters, a emitters) remains a tedious and expensive task. Indeed, usual remote counters show a too low sensitivity to these non-penetrating radiations, while conventional wipe tests are irrelevant for fixed radioactivity evaluation. The only method to accurately measure activity levels consists in sampling and running advanced laboratory analyses (spectroscopy, liquid scintillation counting, pyrolysis...). Such measurements generally induce sample preparation, waste production (destructive analyses, solvents), nuclear material transportation, long durations, and significant labor mobilization. Therefore, the search for the limitation of their number and cost easily conflicts with the necessity to perform a dense screening for sampling (to maximize the representativeness of the samples), in installations of thousands of square meters (floors, wells, ceilings), plus furniture, pipes, and other wastes. To overcome this contradiction, Digital Autoradiography (D. A.) was re-routed from bio molecular research to radiological mapping of nuclear installations under dismantling and to waste and sample analysis. After in-situ exposure to the possibly-contaminated areas to investigate, commercial reusable radiosensitive phosphor screens (of a few 100 cm{sup 2}) were scanned in the proper laboratory device and sharp quantitative images of the radioactivity could be obtained. The implementation of geostatistical tools in the data processing software enabled the exhaustive characterization of concrete floors at a rate of 2 weeks / 100 m{sup 2}, at lowest costs. Various samples such as drilled cores, or tank and wood pieces, were also successfully evaluated with this method, for decisive results. Thanks to the accurate location of potential contamination spots, this approach ensures relevant and representative sampling for further laboratory analyses and should be inserted in the range of common tools used in dismantling. (authors)
Monte Carlo Simulations of the Response of Shielded SNM to a Pulsed Neutron Source
Active interrogation (AI) has been used as a technique for the detection and identification of Special Nuclear Material (SNM) for both proposed and field-tested systems. Idaho National Laboratory (INL) has been studying this technique for systems ranging from small systems employing portable electronic neutron generators (ENGs) 1 to larger systems employing linear accelerators as high-energy photon sources for assessment of vehicles and cargo2. In order to assess the feasibility of new systems, INL has undertaken a campaign of Monte Carlo simulations of the response of a variety of masses of SNM in multiple shielding configurations to a pulsed neutron source using the MCNPX3 code, with emphasis on the neutron and photon response of the system as a function of time after the initial neutron pulse. We present here some preliminary results from these calculations. 1. D.L. Chichester and E.H. Seabury, “ Using Electronic Neutron Generators in Active Interrogation to Detect Shielded Nuclear Material,” IEEE Transactions on Nuclear Science 56 (2009) pp 441-447. 2. J.L. Jones et al., “Photonuclear-based, nuclear material detection system for cargo containers,” Nuclear Instruments and Methods in Physics Research B 241 (2005) pp 770-776. 3. D.B. Pelowitz, “MCNPXTM User’s Manual version 2.6.0,” Los Alamos National Laboratory Report LA-CP-07-1473 (2008).
Development of a Time-tagged Neutron Source for SNM Detection
Associated particle imaging (API) is a powerful technique for special nuclear material (SNM) detection and characterization of fissile material configurations. A sealed-tube neutron generator has been under development by Lawrence Berkeley National Laboratory to reduce the beam spot size on the neutron production target to 1 mm in diameter for a several-fold increase in directional resolution and simultaneously increases the maximum attainable neutron flux. A permanent magnet 2.45 GHz microwave-driven ion source has been adopted in this time-tagged neutron source. This type of ion source provides a high plasma density that allows the use of a sub-millimeter aperture for the extraction of a sufficient ion beam current and lets us achieve a much reduced beam spot size on target without employing active focusing. The design of this API generator uses a custom-made radial high voltage insulator to minimize source to neutron production target distance and to provide for a simple ion source cooling arrangement. Preliminary experimental results showed that more than 100 µA of deuterium ions have been extracted, and the beam diameter on the neutron production target is around 1 mm.
Applications of Nuclear and Particle Physics Technology: Particles & Detection — A Brief Overview
Here, a brief overview of the technology applications with significant societal benefit that have their origins in nuclear and particle physics research is presented. It is shown through representative examples that applications of nuclear physics can be classified into two basic areas: 1) applying the results of experimental nuclear physics and 2) applying the tools of experimental nuclear physics. Examples of the application of the tools of experimental nuclear and particle physics research are provided in the fields of accelerator and detector based technologies namely synchrotron light sources, nuclear medicine, ion implantation and radiation therapy.
CZT nanoRAIDER_VFG Factsheet
Brookhaven National Laboratory (BNL) is working with FLIR System Inc., the manufacturer of the nanoRAIDER, to design a handheld device based on a position-sensitive virtual Frisch-grid (VFG) Cadmium-Zinc-Telluride (CdZnTe or CZT) detector array (with 1% or better energy resolution). The new device called nanoRAIDER VFG will be an improvement to the current nanoRAIDER, which is a compact gamma-ray detection instrument manufactured by FLIR Systems Inc. that employs relatively lower-performing CZT hemispheric detectors (i.e., 3%-FWHM CZT detectors). The nanoRAIDER will significantly improve the accuracy while maintaining similar efficiency, as compared to the nanoRAIDER, for in-field analysis of nuclear materials and detection of undeclared activities during inspections conducted by the International Atomic Energy Agency (IAEA). Since the nanoRAIDER is currently used by the IAEA as part of its Complementary Access toolkit, a relatively quick acceptance of the nanoRAIDER VFG for safeguards is anticipated. The nanoRAIDER VFG will help address several items listed in the IAEA’s Long-Term R&D Plan that could enhance the abilities to detect undeclared nuclear material and activities.