Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “model validation and calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

End-Use Load Profiles for the U.S. Building Stock

The United States is embarking on an ambitious transition to a 100% clean energy economy by 2050, which will require improving the flexibility of electric grids. One way to achieve grid flexibility is to shed or shift demand to align with changing grid needs. To facilitate this, it is critical to understand how and when energy is used. High quality end-use load profiles (EULPs) provide this information, and can help cities, states, and utilities understand the time-sensitive value of energy efficiency, demand response, and distributed energy resources. Publicly available EULPs have traditionally had limited application because of age and incomplete geographic representation. To help fill this gap, the U.S. Department of Energy (DOE) funded a three-year project, End-Use Load Profiles for the U.S. Building Stock, that culminated in this publicly available dataset of calibrated and validated 15-minute resolution load profiles for all major residential and commercial building types and end uses, across all climate regions in the United States. These EULPs were created by calibrating the ResStock and ComStock physics-based building stock models using many different measured datasets, as described in the "Technical Report Documenting Methodology" linked in the submission.

Array↗

Partial Least Squares, Experimental Design, and Near-Infrared Spectrophotometry for the Remote Quantification of Nitric Acid Concentration and Temperature

Near-infrared spectrophotometry and partial least squares regression (PLSR) were evaluated to create a pleasantly simple yet effective approach for measuring HNO3 concentration with varying temperature levels. A training set, which covered HNO3 concentrations (0.1–8 M) and temperature (10–40 °C), was selected using a D-optimal design to minimize the number of samples required in the calibration set for PLSR analysis. The top D-optimal-selected PLSR models had root mean squared error of prediction values of 1.4% for HNO 3 and 4.0% for temperature. The PLSR models built from spectra collected on static samples were validated against flow tests including HNO 3 concentration and temperature gradients to test abnormal conditions (e.g., bubbles) and the model performance between sample points in the factor space. Based on cross-validation and prediction modeling statistics, the designed near-infrared absorption approach can provide remote, quantitative analysis of HNO 3 concentration and temperature for production-oriented applications in facilities where laser safety challenges would inhibit the implementation of other optical techniques (e.g., Raman spectroscopy) and in which space, time, and/or resources are constrained. The experimental design approach effectively minimized the number of samples in the training set and maintained or improved PLSR model performance, which makes the described chemometric approach more amenable to nuclear field applications.

07 ISOTOPE AND RADIATION SOURCES↗

Applications and Development Work for Digital Image Correlation Using High Speed Cameras

NASA, Army, and industry partners are working to advance optical measurement techniques used in highly dynamic rocket engine and missile test environments. This allows for direct component data collection during test and flight environments, significantly reduced analysis time, and associated cost savings. Digital Image Correlation (DIC) uses calibrated stereo cameras to collect three-dimensional (3-D) displacements, strains, and acceleration data by referencing a stochastic speckle pattern applied to the test object. These optical measurement techniques provide significantly improved data resulting in better performance predictions, model validation, and information about components during hot-fire tests and test flights.

Rachel Paden↗

Design and Validation of a Gammaray Scanning System for Measuring Irradiated Nuclear Fuel

A prototype gamma-ray scanning system was designed to perform post-irradiation measurements of nuclear fuel at Idaho National Laboratory (INL). The system is composed of a coaxial high-purity germanium (HPGe) detector, a collimator, and mechanical positioning stages that translate the fuel sample across the front of the collimator. This paper documents the design process, modeling and the laboratory characterization performed to validate the system. The modeling of the system was done using the Monte Carlo N-Particle code with vendor-supplied design specifications, dimensional measurements, and x-ray radiographs of the HPGe detector. The characterization included measurements of calibrated radiation sources in different geometries, and calculations for absolute efficiency and dead time. Benchmark measurements were performed by scanning an irradiated fuel rodlet containing ten pellets of 4.9% enriched UO2 in zirconium alloy. These results were compared to simulated spectra to further help characterize the detector model. One goal of the system is to determine the number of fissions per gram of UO2 in the fuel; comparison of the results from this prototype system's assay of the irradiated fuel rodlet are in agreement with previously estimated results.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Using Calibrated Water Data for Preliminary Validation of the SRT Code for Advanced Reactors

Recent interest and corresponding progress worldwide regarding advanced nuclear reactors has renewed focus on their performance and related safety assessments. Specifically, the U.S. Nuclear Regulatory Commission has emphasized the importance of mechanistic approaches to source term analysis for advanced reactor licensing applications, which attempt to realistically account radionuclide transport and retention phenomena. Further model development is required due to the numerous and complex physical and chemical phenomena associated with mechanistic source term analyses. Reflecting the need for modeling advancement, Argonne National Laboratory developed a mechanistic source term analysis tool for sodium fast reactors. The Simplified Radionuclide Transport (SRT) code describes fuel pin failure (for simulating the initial condition at the point of fuel pin breach), bubble scrubbing, deposition, leakage and following environmental impact. In the current work, a validation study of the SRT bubble scrubbing model is performed using a water-loop experiment performed at the University of Wisconsin-Madison. Through the analysis, the approach and fundamental bubble scrubbing models in SRT, which examine the removal of aerosols within the bubble as it is transported through a pool, have been widely evaluated. The results of the assessment demonstrate a high level of agreement in the regions of greater aerosol size. In the parameter range of minimal aerosol removal, the simulation slightly underpredicts the experiment results; however, considering the scale of plots and huge uncertainties inherently included, the deviation can be judged to be minor and would produce a conservative result. In addition, uncertainty analysis has been further refined to reflect the experimental distribution of parameters including aerosol sizes, which induces a span of performance for each representative aerosol size. Based upon the initial validation results along with uncertainty effects, SRT is expected to provide meaningful insights for the analysis of bubble scrubbing. Future sodium-loop tests will provide further validation basis.

Kam, Dong Hoon↗

DESIGN AND VALIDATION OF A GAMMA-RAY SCANNING SYSTEM FOR MEASURING IRRADIATED NUCLEAR FUEL (ABSTRACT)

A prototype gamma-ray scanning system was designed to perform post-irradiation measurements of nuclear fuel at Idaho National Laboratory (INL). The system is composed of a coaxial high-purity germanium (HPGe) detector, a collimator, and mechanical positioning stages that translate the fuel sample across the front of the collimator. This paper documents the design process, modeling and the laboratory characterization performed to validate the system. The modeling of the system was done using the Monte Carlo N-Particle code with vendor-supplied design specifications, dimensional measurements, and x-ray radiographs of the HPGe detector. The characterization included measurements of calibrated radiation sources in different geometries, and calculations for absolute efficiency and dead time. Benchmark measurements were performed by scanning an irradiated fuel rodlet containing ten pellets of 4.9% enriched UO2 in zirconium alloy. These results were compared to simulated spectra to further help characterize the detector model. One goal of the system is to determine the number of fissions per gram of UO2 in the fuel; comparison of the results from this prototype system's assay of the irradiated fuel rodlet are in agreement with previously estimated results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Using an Absolute Cavity Pyrgeometer to Validate the Calibration of a Transfer Standard Pyrgeometer Outdoors, Independent from the Reference Value of the Atmospheric Longwave Irradiance

A unique method of pyrgeometer calibration has been developed to improve the measurement uncertainty [1]. The results of this method yielded irradiance values within ±3 W/m2 of those traceable to the World InfraRed Standard Group (WISG). The ACPs and pyrgeometer model PIR were deployed outdoors, and the irradiance measured by the PIR was compared against the irradiance measured by ACP95F3. Based on the results it is possible to achieve an uncertainty of ± 3.51 W/m2. These results suggest that the PIR calibration method might be useful in addressing the international need for a secondary standard pyrgeometer traceable to SI.

absolute cavity pyrgeometer↗

Pu(IV) quantification via visible–near-infrared absorption spectroscopy: tackling interferences using D-optimal design and partial least squares

Here, this study presents a novel analytical approach for quantifying Pu(IV) in glove box environments using fiber-optic-based visible–near-infrared absorption spectroscopy in combination with partial least squares regression (PLSR) and design of experiments. The method addresses significant challenges posed by overlapping spectral features arising from Nd(III), which is a common fission product impurity, and the speciation variability of Pu(IV) nitrato complexes in HNO 3 concentrations ranging from 2.5 to 11 M. A curated training set consisting of data from 20 samples was developed via D-optimal design to enable robust PLSR model calibration for Pu(IV) using the near-infrared band near 1050 nm. The training set was acquired from samples in cuvettes with a 1-cm path length and was used to build the PLSR model. The robustness of the model was validated with data collected using a dip probe with a 1-cm path length and varying Pu(IV) concentrations. The strong performance of the model indicates good model transfer from cuvette to dip probe and highlights the potential for in situ measurements and online monitoring of reactions in a crystallization reactor vessel. The results demonstrate that this combined spectroscopic and chemometric approach can accurately and simultaneously quantify Pu(IV) and HNO 3 , thereby offering a promising tool for real-time monitoring in process environments.

Actinide↗

Commercial and Residential Hourly Load Profiles for All Typical Meteorological Year 3 (TMY3) Locations in the United States

One way to achieve grid flexibility is to shed or shift demand to align with changing grid needs. To facilitate this, it is critical to understand how and when energy is used. High-quality end-use load profiles (EULPs) provide this information and can help cities, states, and utilities understand the time-sensitive value of energy efficiency, demand response, and distributed energy resources. Publicly available EULPs have traditionally had limited application because of age and incomplete geographic representation. To help fill this gap, the U.S. Department of Energy funded a 3-year project, End-Use Load Profiles for the U.S. Building Stock, that culminated in this publicly available dataset of calibrated and validated 15-minute-resolution load profiles for all major residential and commercial building types and end uses across all climate regions in the United States. These EULPs were created by calibrating the ResStock and ComStock physics-based building stock models using many different measured datasets, as described in the "Technical Report Documenting Methodology" linked in the submission.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Novel Calibration Approach for Monitoring Aerosol Hydrogen Isotopes Using Laser-Induced Breakdown Spectroscopy for Molten Salt Reactor Off-Gas Streams

Online monitoring is a key challenge for the continued development of molten salt reactor (MSR) technology. Laser-induced breakdown spectroscopy (LIBS) has previously been demonstrated to be a viable tool for monitoring aerosolized species and noble gases in real time, but the ability to discern varying isotopes in these streams has not yet been investigated for MSR applications. Tritium will form in MSRs from ternary fission and from (n,α)-reactions occurring in lithium-containing salts. This study compares three spectrometers of varying resolutions and types for measuring hydrogen isotope shifts in LIBS spectra of wetted filter paper. For each spectrometer, multivariate models were built (i.e., principal component regression, partial least squares regression, and multivariate curve resolution) to quantify the isotope ratio. The top models were then modified and corrected to apply the models to aerosol samples with varying isotope ratios. This novel calibration strategy offers an 82% reduction in volume of the calibration samples needed and is a more viable pathway for calibrating deployable LIBS systems. Lastly, this calibration model was compared with an all-aerosol trained model for monitoring hydrogen isotopes during a real-time test where the protium/deuterium ratio, along with representative salt species (i.e., lithium, sodium, and potassium) were adjusted dynamically. Results of this test validated the predictive capabilities of the transferred model and highlighted the capabilities of LIBS for real-time monitoring of MSR effluent streams.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Wind tunnel test and calibration techniques for the measurement of damping and dynamic cross derivatives due to pitching and yawing

The paper shows how the oscillatory apparatus described previously by Orlik-Rueckemann et al. (1974) for determining cross and cross-coupling moment derivatives due to pitching and yawing oscillation is strengthened, extensively modified, and adapted to permit operation in a large continuous-flow wind tunnel. Particular attention is given to an electromagnetic three-degrees-of-freedom calibrating system developed to verify the validity of the experimental method and the various aspects of data reduction procedure. Typical results from calibration tests and from a series of wind tunnel experiments are presented. The only significant limitation is that the apparatus can only be used for models that are relatively small and have a conically-shaped longitudinal cavity.

Hanff, E. S.↗

Viking Orbiter 75 in-flight pointing calibration of the high-gain antenna

An in-flight pointing calibration technique developed for the Viking Orbiter high-gain antenna has been validated through actual flight usage. The desired telecommunications performance dictated that the high-gain antenna pointing error be held at 0.7 deg, which would have been exceeded without calibration. The in-flight calibration methodology required the development of a stochastic model of the spacecraft rotational biases and earth-received signal strength measurements. The signal strength measurements, which were performed at X-band frequency, were used as observations to estimate the rotational biases and their corresponding uncertainties. Reducing the uncertainties of these parameters resulted in increased antenna pointing accuracy. The initial pointing offset was estimated to be in excess of 1 deg, and after in-flight calibration it was reduced to about 0.66 deg. About 50% of the original offset could not be calibrated, thus the improvement on the remaining offset is better than 50%.

Assefi, T.↗

Experimental and computational surface and flow-field results for an all-body hypersonic aircraft

Personnel from NASA Ames Research Center presented a paper on establishing a benchmark experimental data base for generic hypersonic vehicle shape for validation and/or calibration of advanced computational fluid dynamics computer codes. The need for this capability is based on a requirement for extensive hypersonic data to fully validate CFD codes to be used for NASP and other hypersonic vehicles. The use of wind tunnel models in the Ames 3.5-ft Hypersonic Wind Tunnel to obtain pertinent surface and flow-field data over a broad range of test conditions is described.

Lockman, William K.↗

Raman lidar and sun photometer measurements of aerosols and water vapor during the ARM RCS experiment

The first Atmospheric Radiation Measurement (ARM) Remote Cloud Study (RCS) Intensive Operations Period (IOP) was held during April 1994 at the Southern Great Plains (SGP) Cloud and Radiation Testbed (CART) site near Lamont, Oklahoma. This experiment was conducted to evaluate and calibrate state-of-the-art, ground based remote sensing instruments and to use the data acquired by these instruments to validate retrieval algorithms developed under the ARM program. These activities are part of an overall plan to assess general circulation model (GCM) parameterization research. Since radiation processes are one of the key areas included in this parameterization research, measurements of water vapor and aerosols are required because of the important roles these atmospheric constituents play in radiative transfer. Two instruments were deployed during this IOP to measure water vapor and aerosols and study their relationship. The NASA/Goddard Space Flight Center (GSFC) Scanning Raman Lidar (SRL) acquired water vapor and aerosol profile data during 15 nights of operations. The lidar acquired vertical profiles as well as nearly horizontal profiles directed near an instrumented 60 meter tower. Aerosol optical thickness, phase function, size distribution, and integrated water vapor were derived from measurements with a multiband automatic sun and sky scanning radiometer deployed at this site.

Ferrare, R. A.↗

TESS Science Processing Operations Center Pipeline and Data Products

TESS (Transiting Exoplanet Survey Satellite) launched on 18-4-2018 to conduct a two-year, near all-sky survey for at least 50 nearby exoplanets for which masses can be obtained. TESS just completed surveying the southern hemisphere, identifying hundreds of candidate exoplanet systems and unveiling a plethora of exciting non-exoplanet astrophysics results, such as asteroseismology, asteroids, and supernova. The TESS Science Processing Operations Center (SPOC) at NASA Ames Research Center processes the image data downlinked from TESS every two weeks to generate a variety of data products hosted at the Mikulski Archive for Space Telescopes (MAST). For each approximately 1-month sector, the SPOC calibrates the image data for both 30-minute Full Frame Images (FFIs) and up to 20,000 pre-selected 2-minute target star postage stamps. Simple aperture photometry and systematic error-corrected flux-time series are generated for the 2-minute data. The data products also include co-trending basis vectors (CBVs) and calibration files, such as the Pixel Response Functions (PRF). The archival files are modeled after Kepler's for ease of use, and include Target Pixel Files (TPFs) containing original and calibrated 2-minute image data, Light Curve files (LCs) containing the photometric time series for each 2-minute target, as well as the Data Validation products. New products derived from the FFIs include light curves for the 2-minute targets and CBVs. The TESS Mission is funded by NASA's Science Mission Directorate as an Astrophysics Explorer Mission.

Science Pipeline↗

TESS Science Processing Operations Center Pipeline and Data Products

TESS launched 18-4-2018 to conduct a two-year, near all-sky survey for at least 50 nearby exoplanets for which masses can be. TESS just completed surveying the southern hemisphere, identifying hundreds of candidate exoplanet systems and unveiling a plethora of exciting non-exoplanet astrophysics results, such as asteroseismology, asteroids, and supernova. The TESS Science Processing Operations Center (SPOC) at NASA Ames Research Center processes the image data downlinked from TESS every two weeks to generate a variety of data products hosted at the Mikulski Archive for Space Telescopes (MAST). For each ~1 month sector, the SPOC calibrates the image data for both 30-min Full Frame Images (FFIs) and up to 20,000 pre-selected 2-min target star postage stamps. Simple aperture photometry and systematic error-corrected flux time series are generated for the 2-min data. The data products also include co-trending basis vectors (CBVs) and calibration files, such as the Pixel Response Functions (PRF). The archival files are modeled after Kepler's for ease of use, and include Target Pixel Files (TPFs) containing original and calibrated 2-min image data, Light Curve files (LCs) containing the photometric time series for each 2-min target, as well as the Data Validation products. New products derived from the FFIs include light curves for the 2-min targets and CBVs. The TESS Mission is funded by NASA's Science Mission Directorate as an Astrophysics Explorer Mission.

Jenkins, Jon M.↗

A Universal Refrigerant Charge Fault Detection and Diagnostics Method Based on Pump Down Operation

The performance of the heat pump system varies greatly depending on the refrigerant charge amount. Improving the refrigerant charge fault detection and diagnostics (FDD) method of vapor compression systems have the potential for increasing energy efficiency and reducing service cost. Previous studies to predict refrigerant charge amount are mostly empirical methods which require significant amount of experimental data for high accuracy. The primary goal of this research is to develop a universal charge fault detection method which requires only a few experimental data with high prediction accuracy.Currently, pump down operations are typical practices by HVAC technicians when they need to open the refrigerant circuit to make a repairment. In addition, compressors have a built-in low-pressure cut-off protection function, and the compressor performance maps are commonly available from manufacturers. The proposed method innovatively utilizes the typical pump down operation, the compressor low-pressure cut-off protection, and the compressor performance map. It does not require any geometry information of heat exchangers, refrigerant lines, or charge buffers.The new charge prediction method is firstly formulated through theoretical analysis, then verified and calibrated by a quasi-steady-state simulation of the pump down process for a residential heat pump system. The quasi steady-state simulation uses an HVAC system simulation framework driven by DOE/ORNL Heat Pump Design Model (HPDM). Preliminary experiment validations with heat pump refrigerant leakage tests demonstrate the deviation of the proposed charge prediction method compared with measurement is within 8%. This technology makes refrigerant charge amount available at the technician’s fingertips and leads to shorter maintenance time and fewer site visits.

Li, Zhenning↗

Improving Cost and Efficiency of the Scalable Solid Oxide Fuel Cells Power System

The objective of this project was to design and develop a 20kW range small-scale solid oxide fuel cells (SOFC) power system for applications such as data centers and commercial buildings. The original plan included a 5,000 hours demonstration and a Techno-Economic Analysis (TEA) which were dropped as part of project termination. The original project plan was to use a stack with a cross-flow cell design which had previously been tested for 500 hours at a community college in Malta, NY. However, it was decided to move to the advanced R-SOFC co-flow cell developed under Department of Energy Award DE-FE0031971. The advanced cell design has the advantage of a larger active area for the same manufacturing footprint which results in fewer required cells for the same stack power, hence a higher volumetric power density (kW/L) and lower cost per kW than the original cross-flow cell design. A full SOFC system Simulink model was developed and calibrated with testing data from a fuel cell stack and BOP (balance of plant) components. The simulation results from the calibrated model showed an acceptable match with the experimental data. A structural analysis conducted for various load scenarios indicated no high stress areas for all spatial directions. Major electrical system components were acquired, built and successfully tested. System sensors were verified and validated against controls. Safety checks, a diagnostic check, PID tuning, and control software commissioning tasks were also conducted. The power electronics prototype was delivered and trial testing completed. Balance of Plant component testing and simulation work was conducted to characterize Reformer-Heat Exchanger heat transfer and backpressure and reformer catalyst methane conversion and product selectivity. Simulations were conducted to design the Anode and Cathode fluid passages and size the air-air and fuel-fuel heat exchangers. A Burner operation map was created from test data and the Anode Gas Recirculation blower was tested to evaluate its durability. The SOFC system used a horizontal style design where components sit directly on a casting with a direct connection to the skid. This design has efficient packaging and a small footprint with approximate dimensions of 750 mm x 700 mm x 1700 mm. An SOFC system was built and successfully tested at the Malta, NY facility The system for over 500 hours under load of which over 300 hours was at full load of 20 kW.

30 DIRECT ENERGY CONVERSION↗