Testing and Model Validation of a 100 kWh Radial Packed Bed Thermal Energy Storage System.
Abstract not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Aerodynamic factors, and effects on dynamic longitudinal stability characteristics of tilt wing V/STOL aircraft
Nb-Ti and niobium stannide model superconducting magnet coils performance with regard to thermal stability, charge rate and quench characteristics
Data reduction of transonic wind tunnel static pressure variation tests for correcting Saturn 5 data
The feasibility of quieting the externally-blown-flap (EBF) noise sources which are due to interaction of jet exhaust flow with deployed flaps was demonstrated on a 1/15-scale 3-flap EBF model. Sound field characteristics were measured and noise reduction fundamentals were reviewed in terms of source models. Test of the 1/15-scale model showed broadband noise reductions of up to 20 dB resulting from combination of variable impedance flap treatment and mesh grids placed in the jet flow upstream of the flaps. Steady-state lift, drag, and pitching moment were measured with and without noise reduction treatment.
For comparisons between theoretical and observed charge spectra of the VVH particles to be meaningful, at least two conditions must be met. First, charge resolution must be adequate to separate important groups of nuclei, and there should be no significant systematic errors in the charge scale developed. Second, there must be adequate rejection of slower particles of smaller Z, which have been observed in several flights. Within these conditions, it has been shown that observed features of the charge spectrum are not accidents of the analysis but reflect real variations in the relative abundances that must be explained by any successful model.
For comparisons between theoretical and observed charge spectra of VVH particles to be meaningful, at least two conditions must be met. First, charge resolution must be adequate to separate important groups of nuclei, and there should be no significant systematic errors in the charge scale developed. Second, there must be adequate rejection of slower particles of smaller Z, which have been observed in several flights. Within these conditions, it has been shown that observed features of the charge spectrum are not accidents of the analysis but reflect real variations in the relative abundances that must be explained by any successful model.
The Viking Mars landers to be launched in 1975 will carry experiments in biology, planetology, and atmospheric physics. A terminal dry-heat sterilization process using an inert gas was chosen to meet planetary quarantine requirements and preclude contamination of the biology experiment by terrestrial organisms. Deep sterilization is performed at the component level and terminal surface sterilization at the system level. Solutions to certain component problems relating to sterilization are discussed, involving the gyroscope, tape recorder, battery, electronic circuitry, and outgassing. Heat treatment placed special requirements on electronic packaging, including fastener preload monitoring and solder joints. Chemical and physical testing of nonmetallic materials was performed to establish data on their behavior in heat-treatment and vacuum environments. A Thermal Effects Test Model and a Proof Test Capsule were used. It is concluded that a space vehicle can be designed and fabricated to withstand heat sterilization requirements.
Apsidal-motion constants, k2, have been determined for models of homogeneous main-sequence stars constructed with the new 'Thomas-Fermi' opacities of Carson. These models are similar to those constructed with the 'hydrogenic' opacities of Cox and Stewart up to about 7 solar masses, but yield smaller values of k2 at higher masses. Nevertheless, the new theoretical constants are still systematically too large compared with most of the empirical constants known for members of well-observed binary systems. Uniform rotation is found to lower the theoretical constants only slightly. The effect of normal evolution during core hydrogen burning, however, produces good detailed agreement with observations. The primary of alpha Vir is probably evolving normally if Carson's opacities are adopted.
Zero-equation (algebraic), one-equation (kinetic energy), and two-equation (kinetic energy plus length scale) turbulence eddy viscosity models were used in computing three basic types of shock-separated boundary-layer flows. The three basic types of shock boundary-layer interaction discussed are: (1) a normal shock wave at transonic speeds, (2) a compression corner shock at supersonic speeds, and (3) an incident oblique shock at hypersonic speeds. The models tested are simple, unmodified models used extensively for incompressible, unseparated flows. A comparison of computed and measured results for the compressible, separated flows described herein indicates that model performance is dependent on flow configuration with no distinct superiority of one model over the other for all three flow configurations.
The development of a satellite design demonstration test program is described. The test approach is comprehensive in that it includes the effects from electrostatic discharge (ESD), system generated electromagnetic pulse (SGEMP), as well as dispersed electromagnetic pulses (DEMP). The comprehensive test concept is based on the similarity of the satellite's response to several environments.
There are no author-identified significant results in this report.
Wind tunnel tests were conducted to evaluate the aerodynamic performance of a coannular exhaust nozzle for a proposed variable stream control supersonic propulsion system. Tests were conducted with two simulated configurations differing primarily in the fan duct flowpaths: a short flap mechanism for fan stream control with an isentropic contoured flow splitter, and an iris fan nozzle with a conical flow splitter. Both designs feature a translating primary plug and an auxiliary inlet ejector. Tests were conducted at takeoff and simulated cruise conditions. Data were acquired at Mach numbers of 0, 0.36, 0.9, and 2.0 for a wide range of nozzle operating conditions. At simulated supersonic cruise, both configurations demonstrated good performance, comparable to levels assumed in earlier advanced supersonic propulsion studies. However, at subsonic cruise, both configurations exhibited performance that was 6 to 7.5 percent less than the study assumptions. At take off conditions, the iris configuration performance approached the assumed levels, while the short flap design was 4 to 6 percent less.
Tabulated data from wind tunnel tests conducted to evaluate the aerodynamic performance of an advanced coannular exhaust nozzle for a future supersonic propulsion system are presented. Tests were conducted with two test configurations: (1) a short flap mechanism for fan stream control with an isentropic contoured flow splitter, and (2) an iris fan nozzle with a conical flow splitter. Both designs feature a translating primary plug and an auxiliary inlet ejector. Tests were conducted at takeoff and simulated cruise conditions. Data were acquired at Mach numbers of 0, 0.36, 0.9, and 2.0 for a wide range of nozzle operating conditions. At simulated supersonic cruise, both configurations demonstrated good performance, comparable to levels assumed in earlier advanced supersonic propulsion studies. However, at subsonic cruise, both configurations exhibited performance that was 6 to 7.5 percent less than the study assumptions. At takeoff conditions, the iris configuration performance approached the assumed levels, while the short flap design was 4 to 6 percent less. Data are provided through test run 25.