Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “measurment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Electrostatic-probe measurements of plasma parameters for two reentry flight experiments at 25000 feet per second

Unique plasma diagnostic measurements at high altitudes from two geometrically similar blunt body reentry spacecraft using electrostatic probe rakes are presented. The probes measured the positive ion density profiles (shape and magnitude) during the two flights. The probe measurements were made at eight discrete points (1 cm to 7 cm) from the vehicle surface in the aft flow field of the spacecraft over the altitude range of 85.3 to 53.3 km (280,000 to 175,000 ft) with measured densities of 10 to the 8th power to 10 to the 12th power electrons/cu cm, respectively. Maximum reentry velocity for each spacecraft was approximately 7620 meters/second (25,000 ft/sec). In the first flight experiment, water was periodically injected into a flow field which was contaminated by ablation products from the spacecraft nose region. The nonablative nose of the second spacecraft thereby minimized flow field contamination. Comparisons of the probe measured density profiles with theoretical calculations are presented with discussion as to the probable cause of significant disagreement. Also discussed are the correlation of probe measurements with vehicle angle of attack motions and the good high altitude agreement between electron densities inferred from the probe measurements, VHF antenna measurements, and microwave reflectometer diagnostic measurements.

Jones, W. L., Jr.↗

Measurement in multiphase reacting flows

A survey is presented of diagnostic techniques and measurements made in multiphase reacting flows. The special problems encountered by the presence of liquid droplets, soot and solid particles in high temperature chemically reacting turbulent environments are outlined. The principal measurement techniques that have been tested in spray flames are spark photography, laser anemometry, thermocouples and suction probes. Spark photography provides measurement of drop size, drop size distribution, drop velocity, and angle of flight. Photographs are analysed automatically by image analysers. Photographic techniques are reliable, inexpensive and proved. Laser anemometers have been developed for simultaneous measurement of velocity and size of individual particles in sprays under conditions of vaporization and combustion. Particle/gas velocity differentials, particle Reynolds numbers, local drag coefficients and direct measurement of vaporization rates can be made by laser anemometry. Gas temperature in sprays is determined by direct in situ measurement of time constants immediately prior to measurement with compensation and signal analysis by micro-processors. Gas concentration is measured by suction probes and gas phase chromatography. Measurements of particle size, particle velocity, gas temperature, and gas concentration made in airblast and pressure atomised liquid spray flames are presented.

Chigier, N. A.↗

Performance Measures for Aircraft Landings as a Function of Aircraft Dynamics

A theory of performance measurement for operator controlled systems is presented. The theory permits synthesis of a system performance measure which scores performance on successive data samples based on the impact of the sampled performance on the overall summary of performance. The development of measures for aircraft carrier landings for the glide path and angle of attack control channels is documented. While developing the performance measures, the measures used previously were evaluated and were found to lack the necessary discrimination capability. The previously used measure, the RMS of deviations from the glide path, can, for instance, provide identical scores for both satisfactory and unsatisfactory flight paths. Two types of performance measures developed for aircraft landings are described. Also, an argument is given for the need to test performance measures prior to their use. A suggested test of the measures is offered.

Connelly, E. M.↗

Lidar method of measurement of atmospheric extinction and ozone profiles

A description of a method of measurement of atmospheric extinction and of ozone profiles by use of the backscatter signal from a monostatic lidar is given. The central feature of the procedure involves a measurement of the ratio of the Raman backscatter returns of both the oxygen and nitrogen atmospheric content. Because the ratio of the number density of both species is known to high accuracy, the measurement itself becomes a measure of the ratio of two transmissions to altitude along with a ratio of the two system constants. The calibration measurement for determining the value of the ratio of the two system constants or electro-optical conversion constants is accomplished by a lidar measurement of identical atmospheric targets while at the same time interchanging the two optical filters in the two optical channels of the receiver. More details of the procedure are discussed. Factoring this calibrated value into the measured O2/N2 profile ratio provides a measured value of the ratio of the two transmissions. Or equivalently, it provides a measurement of the difference of the two extinction coefficients at the O2 and N2 Raman wavelengths as a function of the height.

Cooney, J. A.↗

NRL tethered balloon measurements at San Nicolas Island during FIRE IFO 1987

An overview is given of the tethered balloon measurements made during the First ISCCP Regional Experiment (FIRE) marine stratocumulus intensive field observations (IFO) at San Nicolas Island in 1987. The instrument utilized on the balloon flights, the 17 flights over a 10 day period, the state of the data analysis, and some preliminary results are described. A goal of the measurements with the Naval Research Laboratory (NRL) balloon was to give a unique and greatly improved look at the microphysics of the clear and cloud-topped boundary layer. For this goal, collocated measurements were made of turbulence, aerosol, cloud particles, and meteorology. Two new instruments which were expected to make significant contributions to this effort were the saturation hygrometer, capable of measuring 95 percent less than RH 105 percent (with an accuracy of 0.05 percent near 100 percent) and used for the first time in clouds; and the forward scatter meter which gives in situ LWC measurements at more than 10 Hz. The data set, while unfortunately only partially simultaneous with the bulk of the FIRE stratocumulus observations, is unique and worthwhile in its own right. For the first time accurate RH measurements near 100 percent have been made in-cloud; although, the use of the saturation hygrometer reflected a learning experience which will result is substantially better performance the next time. These measurements were made in conjunction with other microphysical measurements such as aerosol and cloud droplet spectra, and perhaps most important of all, they were all collocated with bivane turbulence measurements thus permitting flux calculations. Thus the analysis of this data set, which consisted of about 50 percent stratocumulus cases including increasing and decreasing partial cloud cover, should lead to new insights on the physical mechanisms which drive the boundary-layer/cloud/turbulence system.

Gerber, Hermann↗

Comparison of ground and satellite based measurements of the fraction of photosynthetically active radiation intercepted by tall-grass prairie

The fraction, of photosynthetically active radiation intercepted by vegetation, F(sub ipar) is an important parameter for modeling the interactions between the land-surface and atmosphere and for estimating vegetation biomass productivity. This study was; therefore, an integral part of FIFE. The specific purpose of this experiment was to find out how well definitive measurements of F(sub ipar) on the ground relate to near-ground and satellite based spectral reflectance measurements. Concurrent measurements of F(sub ipar) and ground, helicopter, and satellite based reflectance measurements were taken at thirteen tall-grass prairie sites within the FIFE experimental area. The sites were subjected to various combinations of burning and grazing managements. The ground and helicopter based reflectance measurements were taken on the same day or few days from the time of the overpass of LANDSAT and SPOT satellites. Ground-based reflectance measurements and sun photometer readings taken at the times of the satellite overpasses were used to correct for atmospheric attenuation. Hand-held radiometer spectral indices were strongly correlated with helicopter and satellite based values (r=0.94 for helicopter, 0.93 for LANDSAT Thematic Mapper, and 0.86 for SPOT). However, the ground, helicopter, and satellite based normalized difference spectral vegetation indices showed low sensitivity to changes in F(sub ipar). Reflectance measurements were only moderately well correlated with measurements of F(sub ipar) (r=0.82 for hand-held radiometer, 0.84 for helicopter measurements, and 0.75 for the LANDSAT Thematic Mapper and SPOT). Improved spectral indices which can compensate for site differences are needed in order to monitor F(sub ipar) more reliably.

Demetriades-Shah, T. H.↗

Microgravity acceleration measurement and environment characterization science (17-IML-1)

The Space Acceleration Measurement System (SAMS) is a general purpose instrumentation system designed to measure the accelerations onboard the Shuttle Orbiter and Shuttle/Spacelab vehicles. These measurements are used to support microgravity experiments and investigation into the microgravity environment of the vehicle. Acceleration measurements can be made at locations remote from the SAMS main instrumentation unit by the use of up to three remote triaxial sensor heads. The prime objective for SAMS on the International Microgravity Lab (IML-1) mission will be to measure the accelerations experienced by the Fluid Experiment System (FES). The SAMS acceleration measurements for FES will be complemented by low level, low frequency acceleration measurements made by the Orbital Acceleration Research Experiment (OARE) installed on the shuttle. Secondary objectives for SAMS will be to measure accelerations at several specific locations to enable the acceleration transfer function of the Spacelab module to be analyzed. This analysis effort will be in conjunction with similar measurements analyses on other Spacelab missions.

Source record↗

The measurement system of pulse modulated carrier frequency stability and timing jitter

The definition of pulse modulated carrier frequency stability and timing jitter as well as the configuration and synchronous acquisition measurement method of its measurement system. Frequency stability of the pulse modulated carrier is measured with a discrimination technique. The pulse modulated carrier under testing is mixed with a reference frequency synthesizer. A delay line is used to convert the frequency fluctuation mixed IF signal to the voltage fluctuation. The system has the capability to make the phase noise measurement of two port devices on a pulsed carrier using a phase bridge. The noise voltage mentioned above is applied to the data acquisition and processing unit by PC to realize stability measurement. The data acquisition is in the form of pulse synchronization so that the measurement system accuracy is increased. The pulse width is more than 0.3 microseconds. The phase fluctuation variance, sigma, is less than 0.017. The time interval measuring system with high resolution is used to make interpulse timing and pulse width jitters automatic measurement. The pulse width is less than 0.2 ns. The resolution is 0.1 ns. The system is successfully applied to radar measurement.

Li Cheng-Fu↗

Measurement and analysis of a small nozzle plume in vacuum

Measurements of Pitot pressure and flow angle were made in the plume of a nozzle flowing nitrogen and exhausting to a vacuum. The measurements were compared to results from a numerical simulation of the flow that was based on kinetic theory and used the direct-simulation Monte Carlo (DSMC) method. Numerical results were compared with measurements made in the plume at various axial and radial stations. Total pressure measurements were made with Pitot tubes sized for specific regions of the plume. Flow angle measurements were made with a conical probe. The measurement area for flow angle extended to 160 mm (5 exit diameters) downstream of the nozzle exit plane and radially to 60 mm (1.9 exit diameters) from the plume axis. The total pressure measurements extended 480 mm (16 exit diameters) downstream and radially to 60 mm. Comparisons of computed results from the DSMC method with measurements of flow angle displayed improved agreement with increasing distance from the exit plane. Pitot pressures computed from the DSMC method were in reasonably good agreement with experimental results over the entire measurement area.

Penko, Paul F.↗

A database of aerothermal measurements in hypersonic flow for CFD validation

This paper presents an experimental database selected and compiled from aerothermal measurements obtained on basic model configurations on which fundamental flow phenomena could be most easily examined. The experimental studies were conducted in hypersonic flows in 48-inch, 96-inch, and 6-foot shock tunnels. A special computer program was constructed to provide easy access to the measurements in the database as well as the means to plot the measurements and compare them with imported data. The database contains tabulations of model configurations, freestream conditions, and measurements of heat transfer, pressure, and skin friction for each of the studies selected for inclusion. The first segment contains measurements in laminar flow emphasizing shock-wave boundary-layer interaction. In the second segment, measurements in transitional flows over flat plates and cones are given. The third segment comprises measurements in regions of shock-wave/turbulent-boundary-layer interactions. Studies of the effects of surface roughness of nosetips and conical afterbodies are presented in the fourth segment of the database. Detailed measurements in regions of shock/shock boundary layer interaction are contained in the fifth segment. Measurements in regions of wall jet and transpiration cooling are presented in the final two segments.

Holden, M. S.↗

Electron beam fluorescence measurements in the Boeing hypersonic shock tunnel

The Calspan electron beam fluorescence (EBF) measurement system is described along with the results of measurements made in hypersonic flow. Numerous self-emitting metallic species were identified, many of which may be associated with an aging/erosion process within the B30HST. Because there were only 16 tunnel runs, it was only possible to obtain spectral measurements over a limited range of wavelengths and time sampling periods. Many spectral features of the flow remain uninvestigated. Because flow self-emission is important to all optical diagnostic techniques, it is recommended that additional spectral studies by performed. The three electron beam-excited species that were identified are nitrogen, helium, and nitric oxide. The high metallic radiation background interfered with attempts to obtain the time-wise variation of N2 density and He radiation with the optical fiber/PMT channels. In the case of the N2 density measurements the result of interference was increased uncertainty. Unfortunately, the interference caused the time-wise He measurements to fail completely. It is recommended that the electron beam be modulated to provide discrimination against the background radiation in future N2 density measurements. Careful data reduction produced useful measurements of N2 vibrational temperature, even though the high background from metallic species significantly increased measurement uncertainty. Perhaps the recommended additional spectral studies would reveal N2(+) First Negative System band-pair regions having less background. Detection of the He arrival was easily accomplished with the spectrometer/array detector system. Because of this, it is recommended that this means of detecting He arrival be used in the future. With proper calibrations of the system an He number density could be obtained. Although the flow conditions were out of limits for the run in which the NO spectrum was recorded, the usefulness of the NO spectrum for determination of free-stream rotational temperature was demonstrated and should be exploited in future experiments. Indeed, based on the strong NO signals, it is recommended that lower resolution NO spectra be obtained to provide a measure of NO vibrational temperature in the same manner that the N2 temperature was obtained.

Price, Linwood L.↗

Comparison of ground and satellite based measurements of the fraction of photosynthetically active radiation intercepted by tall-grass prairie

The fraction of photosynthetically active radiation intercepted by vegetation, F(sub ipar) is an important parameter for modeling the interactions between the land-surface and atmosphere and for estimating vegetation biomass productivity. This study was, therefore, an integral part of FIFE. The specific purpose of this experiment was to find out how well definitive measurements of F(sub ipar) on the ground relate to near-ground and satellite based spectral reflectance measurements. Concurrent measurements of F(sub ipar) and ground, helicopter, and satellite based reflectance measurements were taken at thirteen tall-grass prairie sites within the FIFE experimental area. The sites were subjected to various combinations of burning and grazing managements. The ground and helicopter based reflectance measurements were taken on the same day or few days from the time of the overpass of LANDSAT and SPOT satellites. Ground-based reflectance measurements and sun photometer readings taken at the times of the satellite overpasses were used to correct for atmospheric attenuation. Hand-held radiometer spectral indices were strongly correlated with helicopter and satellite based values (r = 0.94 for helicopter, 0.93 for LANDSAT Thematic Mapper, and 0.86 for SPOT). However, the ground, helicopter, and satellite based normalized difference spectral vegetation indices showed low sensitivity to changes in F(sub ipar). Reflectance measurements were only moderately well correlated with measurements of F(sub ipar) (r = 0.82 for hand-held radiometer, 0.84 for helicopter measurements, and 0.75 for the LANDSAT Thematic Mapper and SPOT). Improved spectral indices which can compensate for site differences are needed in order to monitor F(sub ipar) more reliably.

Demetriades-Shah, T. H.↗

Measurement of the frequency stability of responders in aircraft

Measurement on an aircraft orbit, such as a satellite launching orbit, is made by the responder in the aircraft along with several remote track stations on the ground. During the launching, the system is required to have precise time synchronization and frequency accuracy. At the same time, accurate measurement of aircraft velocity requires high frequency stability of the system. However, atomic frequency standards in the ground stations supply time and frequency reference standard with excellent long term and short term frequency stability for the above-mentioned goals. The stability of responder is also an important factor affecting the performance of the system and there are more requirements for the corresponding time/frequency measurements. In the system, the responders do not use continuous wave (CW) but narrow pulse modulated wave; consequently, the characterization theory of their stability is more complicated and the measurement technique is more difficult for pulsed wave than that for CW. A systematic characterization theory of the frequency stability for pulsed wave is demonstrated and the measuring methods are discussed. The measurement systems, which have been set up in Beijing Institute of Radio Metrology and Measurement (BIRMM) and can be used to test the frequency stability of pulse coherent responders in time domain and frequency domain with high sensitivity and accuracy, are described. Using these measurement systems, successful measurements for the responders were made with which the satellite launching orbits were precisely obtained and tracked.

Liu, Xiaofan↗

Measurement of Residual Flexibility for Substructures Having Prominent Flexible Interfaces

Verification of a dynamic model of a constrained structure requires a modal survey test of the physical structure and subsequent modification of the model to obtain the best agreement possible with test data. Constrained-boundary or fixed-base testing has historically been the most common approach for verifying constrained mathematical models, since the boundary conditions of the test article are designed to match the actual constraints in service. However, there are difficulties involved with fixed-base testing, in some cases making the approach impractical. It is not possible to conduct a truly fixed-base test due to coupling between the test article and the fixture. In addition, it is often difficult to accurately simulate the actual boundary constraints, and the cost of designing and constructing the fixture may be prohibitive. For use when fixed-base testing proves impractical or undesirable, alternate free-boundary test methods have been investigated, including the residual flexibility technique. The residual flexibility approach has been treated analytically in considerable detail and has had limited frequency response measurements for the method. This concern is well-justified for a number of reasons. First, residual flexibilities are very small numbers, typically on the order of 1.0E-6 in/lb for translational diagonal terms, and orders of magnitude smaller for off-diagonal values. This poses difficulty in obtaining accurate and noise-free measurements, especially for points removed from the excitation source. A second difficulty encountered in residual measurements lies in obtaining a clean residual function in the process of subtracting synthesized modal data from a measured response function. Inaccuracies occur since modes are not subtracted exactly, but only to the accuracy of the curve fits for each mode; these errors are compounded with increasing distance from the excitation point. In this paper, the residual flexibility method is applied to a simple structure in both test and analysis. Measured and predicted residual functions are compared, and regions of poor data in the measured curves are described. It is found that for accurate residual measurements, frequency response functions having prominent stiffness lines in the acceleration/force format are needed. The lack of such stiffness lines increases measurement errors. Interface drive point frequency respose functions for shuttle orbiter payloads exhibit dominant stiffness lines, making the residual test approach a good candidate for payload modal tests when constrained tests are inappropriate. Difficulties in extracting a residual flexibility value from noisy test data are discussed. It is shown that use of a weighted second order least-squares curve fit of the measured residual function allows identification of residual flexibility that compares very well with predictions for the simple structure. This approach also provides an estimate of second order residual mass effects.

Tinker, Michael L.↗

The study of coronal plasma structures and fluctuations with Faraday rotation measurements

We report dual-frequency, polarimetric measurements of Faraday rotation of extragalactic radio sources viewed through the solar corona. The observations were made at the Very Large Array in 1990 during solar maximum. Of the nine observed, an excess rotation measure of -12.6 rad/sq m was detected for one source (0010+005), which was observed at an elongation of about 9 solar radii. This measurement is in fair agreement with an a priori model rotation measure of -8.6 rad/sq m estimated from coronal potential field models and the electron density model of Paetzold et al. (1992). Our measurement provides a value for the coronal magnetic field strength at 9 solar radii given a knowledge of the magnetic field sector structure, of 12.5 +/- 2.3 mG. Rotation measurements of 0010+005 were made approximately once per hour over an 11 hr period. During this interval, a slow change of about 1 rad/sq m/hr in rotation measure was detected. Although we are not absolutely certain that this drift is not unremoved ionospheric Faraday rotation, extensive analysis of data from the other sources suggests that this is not the case (Sakurai & Spangler 1994). The very long timescale for this variation argues against the agency of magnetohydrodynamics (MHD) waves, and we suggest occultation of 0010+005 by relatively static plasma structures in the corona. We filtered our rotation measure time series to search for variations on an hourly timescale, such as those reported by Hollweg et al. (1992), which could be attributed to coronal MHD waves. We were unable to detect such fluctuations and can report only an upper limit to the rms variation of 1.6 rad/sq m. This upper limit is of the same order, but slightly larger than the values typically reported by Hollweg et al. (1982). This upper limit to the rotation measure fluctuations limits the dimensionless wave amplitude (delta B)/B in the corona to be less than 0.7. Using the number, we estimate the MHD wave flux at the coronal base to be less than 1.6 x 10(exp 5) ergs/sq cm/s. This is less than the amount of wave energy flux required by wave-driven models of the solar wind. Finally, we discuss a number of ways in which such observations could be improved in the future.

Sakurai, Takayuki↗

The validation by measurement theory of proposed object-oriented software metrics

Moving software development into the engineering arena requires controllability, and to control a process, it must be measurable. Measuring the process does no good if the product is not also measured, i.e., being the best at producing an inferior product does not define a quality process. Also, not every number extracted from software development is a valid measurement. A valid measurement only results when we are able to verify that the number is representative of the attribute that we wish to measure. Many proposed software metrics are used by practitioners without these metrics ever having been validated, leading to costly but often useless calculations. Several researchers have bemoaned the lack of scientific precision in much of the published software measurement work and have called for validation of software metrics by measurement theory. This dissertation applies measurement theory to validate fifty proposed object-oriented software metrics (Li and Henry, 1993; Chidamber and Kemerrer, 1994; Lorenz and Kidd, 1994).

Neal, Ralph D.↗

The Validation by Measurement Theory of Proposed Object-Oriented Software Metrics

Moving software development into the engineering arena requires controllability, and to control a process, it must be measurable. Measuring the process does no good if the product is not also measured, i.e., being the best at producing an inferior product does not define a quality process. Also, not every number extracted from software development is a valid measurement. A valid measurement only results when we are able to verify that the number is representative of the attribute that we wish to measure. Many proposed software metrics are used by practitioners without these metrics ever having been validated, leading to costly but often useless calculations. Several researchers have bemoaned the lack of scientific precision in much of the published software measurement work and have called for validation of software metrics by measurement theory. This dissertation applies measurement theory to validate fifty proposed object-oriented software metrics.

Neal, Ralph D.↗

The Validation by Measurement Theory of Proposed Object-Oriented Software Metrics

Moving software development into the engineering arena requires controllability, and to control a process, it must be measurable. Measuring the process does no good if the product is not also measured, i.e., being the best at producing an inferior product does not define a quality process. Also, not every number extracted from software development is a valid measurement. A valid measurement only results when we are able to verify that the number is representative of the attribute that we wish to measure. Many proposed software metrics are used by practitioners without these metrics ever having been validated, leading to costly but often useless calculations. Several researchers have bemoaned the lack of scientific precision in much of the published software measurement work and have called for validation of software metrics by measurement theory. This dissertation applies measurement theory to validate fifty proposed object-oriented software metrics.

Neal, Ralph D.↗