Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “magnetometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Imaging viscous flow of the Dirac fluid in graphene

The electron–hole plasma in charge-neutral graphene is predicted to realize a quantum critical system in which electrical transport features a universal hydrodynamic description, even at room temperature. This quantum critical ‘Dirac fluid’ is expected to have a shear viscosity close to a minimum bound, with an interparticle scattering rate saturating1 at the Planckian time, the shortest possible timescale for particles to relax. Although electrical transport measurements at finite carrier density are consistent with hydrodynamic electron flow in graphene a clear demonstration of viscous flow at the charge-neutrality point remains elusive. In this work, we directly image viscous Dirac fluid flow in graphene at room temperature by measuring the associated stray magnetic field. Nanoscale magnetic imaging is performed using quantum spin magnetometers realized with nitrogen vacancy centres in diamond. Scanning single-spin and wide-field magnetometry reveal a parabolic Poiseuille profile for electron flow in a high-mobility graphene channel near the charge-neutrality point, establishing the viscous transport of the Dirac fluid. This measurement is in contrast to the conventional uniform flow profile imaged in a metallic conductor and also in a low-mobility graphene channel. Furthermore, via combined imaging and transport measurements, we obtain viscosity and scattering rates, and observe that these quantities are comparable to the universal values expected at quantum criticality. This finding establishes a nearly ideal electron fluid in charge-neutral, high-mobility graphene at room temperature4. Our results will enable the study of hydrodynamic transport in quantum critical fluids relevant to strongly correlated electrons in high-temperature superconductors9. This work also highlights the capability of quantum spin magnetometers to probe correlated electronic phenomena at the nanoscale.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

High-Sensitivity rf Detection Using an Optically Pumped Comagnetometer Based on Natural-Abundance Rubidium with Active Ambient-Field Cancellation

To detect a specific radio-frequency (rf) magnetic field, rf optically pumped magnetometers (OPMs) require a static magnetic field to set the Larmor frequency of the atoms equal to the frequency of interest. However, unshielded and variable magnetic field environments (e.g., an rf OPM on a moving platform) pose a problem for rf OPM operation. Here, we demonstrate the use of a natural-abundance rubidium vapor to make a comagnetometer to address this challenge. Our implementation builds upon the simultaneous application of several OPM techniques within the same vapor cell. First, we use a modified implementation of an OPM variometer based on 87 Rb to detect and actively cancel unwanted external fields at frequencies ≲60 Hz using active feedback to a set of field control coils. In this experiment, we exploit this stabilized field environment to implement a high-sensitivity rf magnetometer using 85 Rb. Using this approach, we demonstrate the ability to measure rf fields with a sensitivity of approximately 9 fT Hz -1/2 inside a magnetic shield in the presence of an applied field of approximately 20 μT along three mutually orthogonal directions. This demonstration opens up a path toward completely unshielded operation of a high-sensitivity rf OPM.

47 OTHER INSTRUMENTATION↗

Absolute Magnetometry with He3

We report development of a highly accurate (parts per billion) absolute magnetometer based on 3He NMR. Optical pumping polarizes the spins, long coherence times provide high sensitivity, and the 3He electron shell effectively isolates the nuclear spin providing accuracy limited only by corrections including materials, sample shape, and magnetization. Our magnetometer was used to confirm calibration, to 32 ppb, of the magnetic-field sensors used in recent measurements of the muon magnetic moment anomaly g-2, which differs from the standard model by 2.4 ppm. With independent determination of the magnetic moment of 3He, this work will lead the way to a new absolute magnetometry standard.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Surpassing the Energy Resolution Limit with Ferromagnetic Torque Sensors

We discuss the fundamental noise limitations of a ferromagnetic torque sensor based on a levitated magnet in the tipping regime. We evaluate the optimal magnetic field resolution taking into account the thermomechanical noise and the mechanical detection noise at the standard quantum limit. We find that the energy resolution limit, pointed out in recent literature as a relevant benchmark for most classes of magnetometers, can be surpassed by many orders of magnitude. Moreover, similarly to the case of a ferromagnetic gyroscope, it is also possible to surpass the standard quantum limit for magnetometry with independent spins, arising from spin-projection noise. Our finding indicates that magnetomechanical systems optimized for magnetometry can achieve a magnetic field resolution per unit volume several orders of magnitude better than any conventional magnetometer. Here, we discuss possible implications, focusing on fundamental physics problems such as the search for exotic interactions beyond the standard model.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Impact of remanent magnetic field on the heat load of original CEBAF cryomodule

The heat load of the original cryomodules for the CEBAF accelerator is ~50% higher than the target value of 100 W at 2.07 K for refurbished cavities operating at an accelerating gradient of 12.5 MV/m. This issue is due to the quality factor of the cavities being ~50% lower in the cryomodule than when tested in a vertical cryostat, even at low RF field. Previous studies were not conclusive about the origin of the additional losses. We present the results of a systematic study of the additional losses in a five-cell cavity from a decommissioned cryomodule after attaching components, which are part of the cryomodule, such as the cold tuner, the He tank and the cold magnetic shield, prior to cryogenic testing in a vertical cryostat. Flux-gate magnetometers and temperature sensors are used as diagnostic elements. Different cool-down procedures and tests in different residual magnetic fields were investigated during the study. Here, three flux-gate magnetometers attached to one of the cavities installed in the refurbished cryomodule C50-12 confirmed the hypothesis of high residual magnetic field as a major cause for the increased RF losses.

43 PARTICLE ACCELERATORS↗

X-ray magnetic circular dichroism and small angle neutron scattering study of thiol capped gold nanoparticles.

X-ray magnetic circular dichroism (XMCD) and Small Angle Neutron Scattering (SANS) measurements were performed on thiol capped Au nanoparticles (NPs) embedded into polyethylene. An XMCD signal of 0.8 {center_dot} 10{sup -4} was found at the Au L{sub 3} edge of thiol capped Au NPs embedded in a polyethylene matrix for which Superconducting Quantum Interference Device (SQUID) magnetometry yielded a saturation magnetization, M{sub s}, of 0.06 emu/g{sub Au}. SANS measurements showed that the 3.2 nm average-diameter nanoparticles are 28% polydispersed, but no detectable SANS magnetic signal was found with the resolution and sensitivity accessible with the neutron experiment. A comparison with previous experiments carried out on Au NPs and multilayers, yield to different values between XMCD signals and magnetization measured by SQUID magnetometer. We discuss the origin of those differences.

42 ENGINEERING↗

A Multimodal Event Catalog and Waveform Data Set That Supports Explosion Monitoring from Nevada, U.S.A.

Multimodal, curated data sets and nuisance event catalogs remain rare in the explosion monitoring community relative to curated seismic data sets. The source of this relative absence is the difficultly in deploying multimodal receivers that sense the seismic, acoustic, and other modalities from multiphysics sources. We provide such a data set in this study that delivers seismic, infrasound, and electromagnetic (magnetometer) sensor records collected over a two–week period, within 255 km of a 10 ton buried chemical explosion called DAG–4 that was located at 37.1146°, –116.0693° on 22 June 2019 21:06:19.88 UTC. This catalog includes 485 seismic, seismoacoustic, and infrasound–only events that an expert analyst manually built by reviewing waveforms from 29 seismic and infrasound sensors. Our data release includes waveforms from these 29 seismic, infrasound, and seismoacoustic stations and two magnetometer stations and their station metadata. We deliver these waveforms in NNSA KB Core CSS.w format (i4) with a corresponding wfdisc table that provides the header information. Here, we expect that this data set will provide a valuable, benchmark resource to develop signal processing algorithms and explosion monitoring methods against manual, human observations.

58 GEOSCIENCES↗

Sensitivity of Surface Resistance to Trapped Flux in High-Purity Large-Grain Niobium

Surface resistance arising from trapped flux is experimentally measured, by which the sensitivity to trapped flux is derived. Measurements are carried out with single-cell L-band SRF cavities made of high-purity large-grain niobium materials, immersed in a uniform externally applied magnetic field generated by a solenoid with its axis overlapping the cavity axis. The surface resistance is found by using the standard technique for Q0 measurement and the customary G/Q0 analysis. Q0 values at a fixed low surface field are used. The trapped flux is found by measuring flux densities at a selected location using a single-axis fluxgate magnetometer attached to the cavity outer surface: Ba*[1-(Bsc-Bnc)/(Bsc0-Bnc)], where Ba is the applied external field, Bnc and Bsc is the local flux density measured just above and below Tc, respectively, during a field-cooling of the cavity and afterwards its Q0 is measured, Bsc0 is measured in a separate zero-field-cooling while the cavity being kept in the same location after turning on the identical applied field Ba at a temperature well below Tc . Several magnetometers are placed at various locations. It is found that the sensitivity to trapped flux in high-purity large-grain niobium to be 1.9 n?/µT on average. This is to be compared to 3-9 n?/µT in high purity fine-grain niobium and 10-50 n?/µT in nitrogen-doped high-purity niobium reported by other groups. We will discuss the measurement results as well as the measurement techniques.

Geng, Rongli↗

Rotating-Coil Measurement System for Small-Bore-Diameter Magnet Characterization

Rotating-coil measurement systems are widely used to measure the multipolar fields of particle accelerator magnets. This paper presents a rotating-coil measurement system that aims at providing a complete data set for the characterization of quadrupole magnets with small bore diameters (26 mm). The PCB magnetometer design represents a challenging goal for this type of transducer. It is characterized by an aspect ratio 30% higher than the state of the art, imposed by the reduced dimension of the external radius of the rotating shaft and the necessity of covering the entire magnet effective length (500 mm or higher). The system design required a novel design for the mechanical asset, also considering the innovation represented by the commercial carbon fiber tube, housing the PCB magnetometer. Moreover, the measurement system is based primarily on standard and commercially available components, with simplified control and post-processing software applications. The system and its components are cross-calibrated using a stretched-wire system and another rotating-coil system. The measurement precision is established in a measurement campaign performed on a quadrupole magnet characterized by an inner bore diameter of 45 mm.

42 ENGINEERING↗

ISIS-B spacecraft magnetic tests

Magnetic tests of the ISIS B spacecraft were conducted to determine the various magnetic moments of the spacecraft, evalute its spin and attitude control systems, and calibrate the six onboard magnetometer probes. Test procedures and equipment are described. Techniques for evaluting the data are discussed, and test results are presented. The spacecraft's magnetic characteristics were found to be satisfactory. Proper threshold values for gating the torquing coils were obtained. The onboard magnetometers were satisfactorily calibrated.

Boyle, J. C.↗

Thin highly conducting layer in the moon - Consistent interpretation of dayside and nightside electromagnetic responses.

The vacuum transient response of the moon to a time-varying spatially uniform magnetic field is determined for a lunar electrical conductivity model that was based on the harmonic analysis of Apollo 12 and Explorer 35 dayside magnetometer data. The transient response of the model is found to provide a plausible explanation of the behavior of the local vertical-surface magnetic field for an Apollo 12 magnetometer darkside transient event. A model containing a conducting core and a highly conducting thin subsurface layer is presented, and its transient behavior is discussed.

Schubert, G.↗

Mie scattering of the interplanetary magnetic field by the whole moon

It is known from the Apollo magnetometer experiments that significant electromagnetic induction takes place in the lunar interior. This induction is excited by fluctuations of the interplanetary magnetic field and is detected by the induced fields on the surface of the moon. These results are reviewed briefly and the formal properties of the theory are discussed. It is shown that the mathematical treatment parallels that for classical electromagnetic scattering. Further the wavelength spectrum of the fluctuations of the interplanetary magnetic field include scales consistent with the radius of the moon. The consequence is that the moon is excited in several modes. Quadrupole and possibly octupole magnetic multipoles are found in the data. The electric type radiation corresponding to transverse magnetic excitation appears suppressed and far below the detection threshold of the magnetometers.

Sonett, C. P.↗

Nightside electromagnetic response of the moon

The electromagnetic response of the Moon to excitation by the time dependent fluctuations of the interplanetary magnetic field is given for the dark or antisolar hemisphere of the Moon. Six hours of time series data from the Explorer 35 magnetometer and the lunar surface magnetometer on Apollo 12 are used to obtain the Fourier spectral amplitudes of the surface and interplanetary fields from which transfer functions are calculated for the east-west, north-south, and vertical directions at the Apollo site. A critical discussion of lunar conductivity profiles derived from night side radial magnetic field data and vacuum scattering theory is presented. Limitations are shown that there is no evidence for a lunar core as conducting as 0.01 mhos/m.

Schubert, G.↗

Measurement of auroral Birkeland currents and energetic particle fluxes.

A rocket-borne experiment containing a vector magnetometer and a set of charged-particle detectors was launched from Poker Flat, Alaska, at 2217 LT on February 13, 1971, over a single auroral arc. Particle data in the energy range 0.5-20 kev, obtained during part of the flight, show a peak incident flux of 40 millions electrons per sq cm sec ster kev in the energy range 1-2 kev. The pitch angle distributions of these precipitating electrons were found to be fairly isotropic from 0 to 60 deg and to decrease from 60 to 90 deg. The results of the vector magnetometer indicate the existence of a system of Birkeland currents with magnitudes of 5 microamperes/sq m in the vicinity of the auroral arc. Two different models that fit the data are discussed.

Cloutier, P. A.↗

Induced magnetosphere of the moon. II - Experimental results from Apollo 12 and Explorer 35.

The asymmetric lunar electromagnetic induction theory of Schubert et al. (1973) is tested by using data from the Apollo 12 Lunar Surface Magnetometer and from the Ames magnetometer on Explorer 35. The comparison of data and theory shows that the moon displays an induction asymmetry due to the flow of the solar wind and the formation of the diamagnetic cavity on the darkside. It is inferred that the induced field forms a magnetospheric-like configuration, with the field confined mostly to the crust of the moon. Although the magnetospheric spectrum is time-dependent for all frequencies examined, the distance traveled by the solar wind is so large that a quasi-static magnetospheric configuration can be assumed. The differential power spectrum of the interplanetary magnetic field that excites the moon is compared with the resulting induction spectrum, which has a linear differential power frequency dependence over the frequency range from .0002 to .02 Hz, falling off on either side of these limits. The integrated power in this band is about 5 gamma squared for the interplanetary field local north-south component and about 12 gamma squared for the induced spectrum of this component on the lunar surface.

Smith, B. F.↗

Effects on the geomagnetic tail at 60 earth radii of the geomagnetic storm of April 9, 1971.

A geomagnetic storm beginning with an sc occurred on Apr. 9, 1971. During the storm the charged particle lunar environment experiment at the Apollo 14 site, the solar wind spectrometer experiment at the Apollo 12 site, and the Ames magnetometers on Explorer 35 took data in the magnetosheath, at the magnetopause, in the plasma sheet, and in the high-latitude geomagnetic tail. The MIT Faraday cup and Ames magnetometers on board Explorer 33 monitored the solar wind. The data show that the storm was caused by a corotating tangential discontinuity in the solar wind, the magnetopause position is strongly dependent on the attack angle of the solar wind, and the tail field strength was indirectly measured to increase from 10 to 14 gamma after the sc. During the main phase the field strength in the tail was observed to increase to between 28 and 34 gamma. This increase is consistent with a thermal and magnetic compression of the tail radius from about 26 to about 16 earth radii.

Burke, W. J.↗

Magnetic-heading reference device

Inexpensive and reliable device is used in conjunction with fluidic-electronic wing-leveler system. Single magnetometer is placed so pilot can make adjustments in aircraft heading simply by rotating magnetometer itself.

Garner, H. D.↗

GSFC magnetic field experiment Explorer 43

The magnetic field experiment flown on Explorer 43 is described. The detecting instrument is a triaxial fluxgate magnetometer which is mounted on a boom with a flipping mechanism for reorienting the sensor in flight. An on-board data processor takes successive magnetometer samples and transmits differences to the telemetry system. By examining these differences in conjunction with an untruncated sample transmitted periodically, the original data may be uniquely reconstructed on the ground.

Seek, J. B.↗