At least 649 records · Page 36

Bragg Curve, Biological Bragg Curve and Biological Issues in Space Radiation Protection with Shielding

The space environment consists of a varying field of radiation particles including high-energy ions, with spacecraft shielding material providing the major protection to astronauts from harmful exposure. Unlike low-LET gamma or X-rays, the presence of shielding does not always reduce the radiation risks for energetic charged particle exposure. Since the dose delivered by the charged particle increases sharply as the particle approaches the end of its range, a position known as the Bragg peak, the Bragg curve does not necessarily represent the biological damage along the particle traversal since biological effects are influenced by the track structure of both primary and secondary particles. Therefore, the biological Bragg curve is dependent on the energy and the type of the primary particle, and may vary for different biological endpoints. To achieve a Bragg curve distribution, we exposed cells to energetic heavy ions with the beam geometry parallel to a monolayer of fibroblasts. Qualitative analyses of gamma-H2AX fluorescence, a known marker of DSBs, indicated increased clustering of DNA damage before the Bragg peak, enhanced homogenous distribution at the peak, and provided visual evidence of high linear energy transfer (LET) particle traversal of cells beyond the Bragg peak. A quantitative biological response curve generated for micronuclei (MN) induction across the Bragg curve did not reveal an increased yield of MN at the location of the Bragg peak. However, the ratio of mono-to bi-nucleated cells, which indicates inhibition in cell progression, increased at the Bragg peak location. These results, along with other biological concerns, show that space radiation protection with shielding can be a complicated issue.

Honglu, Wu↗

NASA Tech Briefs, August 2011

Topics covered include: Miniature, Variable-Speed Control Moment Gyroscope; NBL Pistol Grip Tool for Underwater Training of Astronauts; HEXPANDO Expanding Head for Fastener-Retention Hexagonal Wrench; Diagonal-Axes Stage for Pointing an Optical Communications Transceiver; Improvements in Speed and Functionality of a 670-GHz Imaging Radar; IONAC-Lite; Large Ka-Band Slot Array for Digital Beam-Forming Applications; Development of a 150-GHz MMIC Module Prototype for Large-Scale CMB Radiation; Coupling Between Waveguide-Fed Slot Arrays; PCB-Based Break-Out Box; Multiple-Beam Detection of Fast Transient Radio Sources; Router Agent Technology for Policy-Based Network Management; Remote Asynchronous Message Service Gateway; Automatic Tie Pointer for In-Situ Pointing Correction; Jitter Correction; MSLICE Sequencing; EOS MLS Level 2 Data Processing Software Version 3; DspaceOgre 3D Graphics Visualization Tool; Metallization for Yb14MnSb11-Based Thermoelectric Materials; Solvent/Non-Solvent Sintering To Make Microsphere Scaffolds; Enhanced Fuel-Optimal Trajectory-Generation Algorithm for Planetary Pinpoint Landing; Self-Cleaning Coatings and Materials for Decontaminating Field-Deployable Land and Water-Based Optical Systems; Separation of Single-Walled Carbon Nanotubes with DEP-FFF; Li Anode Technology for Improved Performance; Post-Fragmentation Whole Genome Amplification-Based Method; Microwave Tissue Soldering for Immediate Wound Closure; Principles, Techniques, and Applications of Tissue Microfluidics; Robotic Scaffolds for Tissue Engineering and Organ Growth; Stress-Driven Selection of Novel Phenotypes; Method for Accurately Calibrating a Spectrometer Using Broadband Light; Catalytic Microtube Rocket Igniter; Stage Cylindrical Immersive Display; Vacuum Camera Cooler; Atomic Oxygen Fluence Monitor; Thermal Management Tools for Propulsion System Trade Studies and Analysis; Introduction to Physical Intelligence; Technique for Solving Electrically Small to Large Structures for Broadband Applications; Accelerated Adaptive MGS Phase Retrieval; Large Eddy Simulation Study for Fluid Disintegration and Mixing; Tropospheric Correction for InSAR Using Interpolated ECMWF Data and GPS Zenith Total Delay; Technique for Calculating Solution Derivatives With Respect to Geometry Parameters in a CFD Code; Acute Radiation Risk and BRYNTRN Organ Dose Projection Graphical User Interface; Probabilistic Path Planning of Montgolfier Balloons in Strong, Uncertain Wind Fields; Flight Simulation of ARES in the Mars Environment; Low-Outgassing Photogrammetry Targets for Use in Outer Space; Planning the FUSE Mission Using the SOVA Algorithm; Monitoring Spacecraft Telemetry Via Optical or RF Link; and Robust Thermal Control of Propulsion Lines for Space Missions.

Source record↗

Overexpression of neurofilament H disrupts normal cell structure and function

Studying exogenously expressed tagged proteins in live cells has become a standard technique for evaluating protein distribution and function. Typically, expression levels of experimentally introduced proteins are not regulated, and high levels are often preferred to facilitate detection. However, overexpression of many proteins leads to mislocalization and pathologies. Therefore, for normative studies, moderate levels of expression may be more suitable. To understand better the dynamics of intermediate filament formation, transport, and stability in a healthy, living cell, we inserted neurofilament heavy chain (NFH)-green fluorescent protein (GFP) fusion constructs in adenoviral vectors with tetracycline (tet)-regulated promoters. This system allows for turning on or off the synthesis of NFH-GFP at a selected time, for a defined period, in a dose-dependent manner. We used this inducible system for live cell imaging of changes in filament structure and cell shape, motility, and transport associated with increasing NFH-GFP expression. Cells with low to intermediate levels of NFH-GFP were structurally and functionally similar to neighboring, nonexpressing cells. In contrast, overexpression led to pathological alterations in both filament organization and cell function. Copyright 2002 Wiley-Liss, Inc.

Non-NASA Center↗

Radiation Response of Emerging FeRAM Technology

The test results of measurements performed on two different sizes of ferroelectric random access memory (FeRAM) suggest the degradation is due to the low radiation tolerance of sense amplifiers and reference voltage generators which are based on commercial complementary metal oxide semiconductor (CMOS) technology. This paper presents total ionizing dose (TID) testing of 64Kb Ramtron FM1608 and 256Kb Ramtron FM1808.

Nguyen, D. N.↗

Monte-Carlo Simulations of Heavy Ions Track Structures and Applications

In space, astronauts are exposed to protons, high ]energy heavy (HZE) ions that have a high charge (Z) and energy (E), and secondary radiation, including neutrons and recoil nuclei produced by nuclear reactions in spacecraft walls or in tissue. The astronauts can only be partly shielded from these particles. Therefore, on travelling to Mars, it is estimated that every cell nucleus in an astronaut fs body would be hit by a proton or secondary electron (e.g., electrons of the target atoms ionized by the HZE ion) every few days and by an HZE ion about once a month. The risks related to these heavy ions are not well known and of concern for long duration space exploration missions. Medical ion therapy is another situation where human beings can be irradiated by heavy ions, usually to treat cancer. Heavy ions have a peculiar track structure characterized by high levels of energy ]deposition clustering, especially in near the track ends in the so ]called eBragg peak f region. In radiotherapy, these features of heavy ions can provide an improved dose conformation with respect to photons, also considering that the relative biological effectiveness (RBE) of therapeutic ions in the plateau region before the peak is sufficiently low. Therefore, several proton and carbon ion therapy facilities are under construction at this moment

Plante, Ianik↗

Evaluation of 2 possible further developments of the UK in-flight radiation warning meter for SSTS

A mass reduction of the moderator and the response to the nucleon flux, responsible for the tissue-star component of the total-dose equivalent rate using a high atomic number material, are discussed. Radiation situations at SST cruising altitudes (approximately 20 km) due to solar proton flares were simulated in the stratosphere and on the ground. Actual stratospheric situations due to galactic cosmic radiation with a limited range of quality factor values (2-4) were encountered during slow ascents by balloons to 36 km. Synthetic situations obtained from high and low energy acclerator radiations were used to obtain radiation distributions having a larger range of quality factor values (11/2-9) than experienced in the stratosphere. The measurements made in these simulations related to the directly ionizing, neutron and tissue-star components of dose-equivalent rate. Due to the restricted range of neutron spectra encountered in the stratosphere, a significant mass reduction of the moderator by 4 kg was made, with the moderator clad with cadmium or some other slow neutron absorber.

Wilson, I. J.↗

Structural materials for space applications

The long-term performance of structural materials in the space environment is a key research activity within NASA. The primary concerns for materials in low Earth orbit (LEO) are atomic oxygen erosion and space debris impact. Atomic oxygen studies have included both laboratory exposures in atomic oxygen facilities and flight exposures using the Shuttle. Characterization of atomic oxygen interaction with materials has included surface recession rates, residual mechanical properties, optical property measurements, and surface analyses to establish chemical changes. The Long Duration Exposure Facility (LDEF) is scheduled to be retrieved in 1989 and is expected to provide a wealth of data on atomic oxygen erosion in space. Hypervelocity impact studies have been conducted to establish damage mechanisms and changes in mechanical properties. Samples from LDEF will be analyzed to determine the severity of space debris impact on coatings, films, and composites. Spacecraft placed in geosynchronous Earth orbit (GEO) will be subjected to high doses of ionizing radiation which for long term exposures will exceed the damage threshold of many polymeric materials. Radiation interaction with polymers can result in chain scission and/or cross-linking. The formation of low molecular weight products in the epoxy plasticize the matrix at elevated temperatures and embrittle the matrix at low temperatures. This affects both the matrix-dominated mechanical properties and the dimensional stability of the composite. Embrittlement of the matrix at low temperatures results in enhanced matrix microcracking during thermal cycling. Matrix microcracking changes the coefficient of thermal expansion (CTE) of composite laminates and produces permanent length changes. Residual stress calculations were performed to estimate the conditions necessary for microcrack development in unirradiated and irradiated composites. The effects of UV and electron exposure on the optical properties of transparent polymer films were also examined to establish the optimum chemical structure for good radiation resistance. Thoughts on approaches to establishing accelerated testing procedures are discussed.

Tenney, Darrel R.↗

Recent Radiation Test Results for Trench Power MOSFETs

Single-event effect (SEE) radiation test results are presented for various trench-gate power MOSFETs. The heavy-ion response of the first (and only) radiation-hardened trench-gate power MOSFET is evaluated: the manufacturer SEE response curve is verified and importantly, no localized dosing effects are measured, distinguishing it from other, non-hardened trench-gate power MOSFETs. Evaluations are made of n-type commercial and both n- and p-type automotive grade trench-gate device using ions comparable to of those on the low linear energy transfer (LET) side of the iron knee of the galactic cosmic ray spectrum, to explore suitability of these parts for missions with higher risk tolerance and shorter duration, such as CubeSats. Part-to-part variability of SEE threshold suggests testing with larger sample sizes and applying more aggressive derating to avoid on-orbit failures. The n-type devices yielded expected localized dosing effects including when irradiated in an unbiased (0-V) configuration, adding to the challenge of inserting these parts into space flight missions.

Schottky Diodes↗

Radiation exposure of LDEF: Initial results

Initial results from Long Duration Exposure Facility (LDEF) include radiation detector measurements from four experiments; P0006, P0004, M0004, and A0015. The detectors were located on both the leading and trailing edges of the orbiter and also at the Earthside end. This allowed the directional dependence of the incoming radiation to be measured. Total absorbed doses from thermoluminescent detectors (TLDs) verified the predicted spatial east-west dose dependence of a factor of approx. 2.5, due to trapped proton anisotropy in the South Atlantic Anomaly (SAA). On the trailing edge of the orbiter, a range of doses from 664 to 291 rad were measured under nominal shielding of 0.42 to 8.45 g/sq cm. A second set of detectors near this locations results are also given. On the leading edge, doses of 258 to 210 rad were found under shielding of 1.25 to 2.48 g/sq cm. Initial charged particle LET (linear energy transfer) spectra, fluxes, doses, and dose equivalents, for LET in H2O greater than or = 5 keV/micron, were measured with plastic nuclear track detectors located in the four experiments. Also, preliminary data on low energy neutrons were obtained from detectors containing (6)LiF foils.

Benton, E. V.↗

Radiation exposure of LDEF: Initial results

Initial results from LDEF include radiation detector measurements from four experiments, P0006, P0004, M0004, and A0015. The detectors were located on both the leading and trailing edges of the orbiter and also on the Earthside end. This allowed the directional dependence of the incoming radiation to be measured. Total absorbed doses from thermoluminescent detectors (TLDs) verified the predicted spatial east-west dose ratio dependence of a factor approx. 2.5, due to trapped proton anisotropy in the South Atlantic Anomaly. On the trailing edge of the orbiter a range of doses from 6.64 to 2.91 Gy were measured under Al equivalent shielding of 0.42 to 1.11 g/sq cm. A second set of detectors near this location yielded doses of 6.48 to 2.66 Gy under Al equivalent shielding of 0.48 to 15.4 g/sq cm. On the leading edge, doses of 2.58 to 2.10 Gy were found under Al equivalent shielding of 1.37 to 2.90 g/sq cm. Initial charged particle LET (linear energy transfer) spectra, fluxes, doses and dose equivalents, for LET in H2O greater than or = 8 keV/micron, were measured with plastic nuclear track detectors (PNTDs) located in two experiments. Also preliminary data on low energy neutrons were obtained from detectors containing (6)LiF foils.

Benton, E. V.↗

Spaceflight Autonomous Multigenerational Microbial Sequencer in Support of Plant-Growth Systems

The CubeSat platform has proven successful in obtaining meaningful life science information when biological payloads are incorporated. Examples include: 1) the first-ever CubeSat with a biological payload, GeneSat-1, which demonstrated decreased growth rates for flight samples of Escherichia coli in low Earth orbit (Parra et al. 2008); 2) PharmaSat, demonstrated that Saccharomyces cerevisiae in the microgravity environment exhibits a significant level of metabolic activity even at high doses of applied antifungal (Ricco et al. 2011); 3) O/OREOS, which used Bacillus subtilis(bacteria) to demonstrate for the first time that microorganisms can be loaded in a dried, dormant form and then rehydrated and grown in orbit months after launch (Nicholson et al. 2011; Ehrenfreund et al. 2014; 4) the SporeSat payload, which investigated Ceratopteris richardii(fern spores) using lab-on-a-chip devices (BioCDs) and minicentrifuges to produce artificial gravitational forces in ground studies (Park et al. 2017), with demonstration of the BioCD and minicentrifuge in space; 5) EcAMSat, the first CubeSat to be directly deployed from the ISS for an experiment assessing antibiotic resistance of E. coli in the microgravity environment (Padgen et al. 2020); 6) BioSentinel, exposed a culture of yeast to galactic cosmic radiation (GCR) and solar particle events while in heliocentric orbit to measure the rate of double-strand-break repair using DNA-repair-deficient mutants. This effort measures the metabolic parameters of yeast in a deep-space environment compared to Earth ambient conditions using a 3-color LED detection system (Ricco et al. 2020; Padgen et al. 2021). We aim to expand this list to include a Spaceflight Autonomous Multigenerational Microbial Sequencer (SAMMS). SAMMS will allow for the genome level understanding of changes in growth and metabolic activity for any organism. While microbes are suitable for early studies in our proposed platform because of their small size, small and relatively less-complicated genomes, fast generation times, and relevance to life support systems; multicellular organisms can similarly be evaluated for their genetic response to the spaceflight environment. The Spaceflight Autonomous Multigenerational Microbial Sequencer (SAMMS) will enable autonomous sequencing of biological samples in plant production units, cislunar orbit and on the lunar surface to examine spaceflight effects (ie. radiation, altered gravity, reduced pressures) on plant and microbial genomes.On this team a Kennedy Space Center (KSC) space crop production and water systems microbiologist/molecular biologist works with a Johnson Space Center (JSC) International Space Station (ISS) microbial sequencing expert and an Ames Research Center (ARC) CubeSat Engineering team to convert an automated Oxford Nanopore librarypreparation and sequencing method to a fluidic CubeSat payload system. The Oxford Nanopore MinION sequencing platform has proven successful in the spaceflight environment onboard the ISS (Stahl-Rommel et al. 2021). Further long-duration spaceflight and exposure to high levels of radiation will cause genotypic effects in biological organisms that may affect their function. Monitoring the adaption of a population to the spaceflight environment and any subsequent beneficial mutations will allow for the harnessing of organisms best suited for use in life support systems. This will ensure that the selected life support-essential microorganisms maintain their intended specified function over generations of culturing in the relevant spaceflight environment without becoming hazardous to crew or spacecraft systems.

Aubrie E Orourke↗

Importance of dose-rate and cell proliferation in the evaluation of biological experimental results

The nuclei of cells within the bodies of astronauts traveling on extended missions outside the geomagnetosphere will experience single traversals of particles with high Linear Energy Transfer (LET) (e.g., one iron ion per one hundred years, on average) superimposed on a background of tracks with low LET (approximately one proton every two to three days, and one helium ion per month). In addition, some cell populations within the body will be proliferating, thus possibly providing increasing numbers of cells with 'initiated' targets for subsequent radiation hits. These temporal characteristics are not generally reproduced in laboratory experimental protocols. Implications of the differences in the temporal patterns of radiation delivery between conventionally designed radiation biology experiments and the pattern to be experienced in space are examined and the importance of dose-rate and cell proliferation are pointed out in the context of radiation risk assessment on long mission in space.

Curtis, S. B.↗

Global Variability in Sonic Boom Exposure due to Macroscopic Effects

Supersonic flight over land has been prohibited since 1973 due to the loudness of sonic booms. NASA is building the X-59 aircraft as part of its Quesst mission to demonstrate low-loudness shaped sonic booms, or “sonic thumps.” The Quesst mission will gather human perception data via a series of community noise surveys across the USA. The noise dose and perceptual response data will be provided to the International Civil Aviation Organization (ICAO) and the Federal Aviation Administration for use in determining potential future supersonic aircraft noise certification standards, effectively changing the prohibition from a speed limit to a noise limit. These noise regulations must be globally effective, as long travel distances see the largest benefit to supersonic flight. The state of the atmosphere through which a sonic boom travels affects the size of the region exposed to sound, the “carpet width” (CW), as well as the loudness. The focus of this dissertation is to understand and quantify the expected loudness and CW of sonic booms due to the macroscopic atmospheric effects around the world. A pair of large-scale propagation simulation studies were conducted using the NASA PCBoom code to compare predicted sonic boom loudness and CW statistics first across the USA and then across the world. For the USA study, near-field data of the X-59 in steady cruise was propagated at 4 cardinal headings at 138 locations through 5 years of Climate Forecast System Version 2 (CFSv2) atmospheric profiles. Results of a bootstrap forest predictor screening model indicated the importance of climate zone, latitude, ground elevation, season, and heading. It also noted the unimportance of time of day for predicting loudness and CW. The data is visualized in aggregate, and then broken out geographically, by season and heading, and by climate zone. Multiple linear regression models were fit to the data from the 138 locations so that estimates of the loudness and CW can be produced anywhere in the US. The results can aid in planning when and where to fly the X-59. For the global study, near-field data from three aircraft, the X-59 in a quiet and loud configuration, B-58, and Concorde, were propagated at four cardinal headings through data from three atmospheric models, the CFSv2, the Global Forecast System (GFS), and the ECMWF Reanalysis Version 5 (ERA5), at 100 global locations over 1 year. Results of a bootstrap forest predictor screening model indicated the importance of climate zone, ground elevation, season, and heading. Similar to the US study, the model indicated time of day was not an important predictor. The model also indicated that choice of weather model was not important, so the atmospheric model data are effectively interchangeable. The ERA5 model was chosen for use in an extension of the study to include 18 additional locations to ensure sampling of every climate zone. Loudness and CW results are shown in aggregate, and split geographically and by heading, season, and climate. Multiple linear regression models were fit to the data from the 118 locations so that estimates of loudness and CW can be produced around the world. N-waves and shaped booms did not have the same global variability. Koppen-Geiger climate zones were used as the climate zone definition for the global study. These are available as present-day and future climate projections. Making use of the multiple linear regression models, the future climate zones were input to estimate the effect of the changing climate on sonic boom loudness and CW. Results indicate that a changing climate would have little impact on the effectiveness of noise regulations.

X-59↗

Radiometric and Radiation Response of Visible FPAs

The readout integrated circuit (ROIC) used in these devices was originally developed for use in space based infrared systems operating at deep cryogenic temperatures and was selected because of its proven tolerance to total ionizing radiation? The detectors are a 128 x 128 array of 60 pm x 60 pm pixel elements that have been anti-reflection (AR) coated to improve the response at very short wavelengths. These visible focal plane arrays were operated at -40 C (233 K). Two focal planes were characterized using cobalt-60 radiation to produce ionizing total dose damage in the VFPAs. Both operational and performance data were obtained as functions of total dose. The first device tested showed no appreciable change in responsivity or noise up to 300 krad(Si). However, at the next dose level of 600 krad(Si), the readout was non-operational due to failure in the digital circuitry. The second device was characterized to a total dose of 750 krad(Si) with no observed change in responsivity. An increase dark current was observed in both devices, and in the second device, the dark current caused an increase in noise at low irradiance at 400 krad(Si) and above. The increase in dark current was somewhat un-expected for visible PIN detectors. The median dark current increased more than two orders of magnitude at 300 krad(Si) for the first device and a factor of 350 at 750 krad(Si) for pixels near the edge for the second device. The dark current was found to be a strong function of detector bias, with pixels near the edge of the array showing a greater increase in dark current with bias than those near the center. Since the optical response was not a function of bias, it is hypothesized that the dark current is a surface effect and that the variation in dark current with location is due to a variation in pixel bias, caused by a voltage drop across the pixel common lead. As the total dose increased, the dark current and the voltage drop increased

Hubbs, John↗

Analysis of a Radiation Model of the Shuttle Space Suit

The extravehicular activity (EVA) required to assemble the International Space Station (ISS) will take approximately 1500 hours with 400 hours of EVA per year in operations and maintenance. With the Space Station at an inclination of 51.6 deg the radiation environment is highly variable with solar activity being of great concern. Thus, it is important to study the dose gradients about the body during an EVA to help determine the cancer risk associated with the different environments the ISS will encounter. In this paper we are concerned only with the trapped radiation (electrons and protons). Two different scenarios are looked at: the first is the quiet geomagnetic periods in low Earth orbit (LEO) and the second is during a large solar particle event in the deep space environment. This study includes a description of how the space suit's computer aided design (CAD) model was developed along with a description of the human model. Also included is a brief description of the transport codes used to determine the total integrated dose at several locations within the body. Finally, the results of the transport codes when applied to the space suit and human model and a brief description of the results are presented.

Anderson, Brooke M.↗

Model calculations of the radiation dose and LET spectra on LDEF and comparisons with flight data

Ionizing radiation environment models, a 3-D spacecraft mass model, and radiation transport codes have been used to predict the radiation dose and linear energy transfer (LET) spectra measured at various locations on the LDEF satellite. The predictions are compared with thermoluminescent dosimeter measurements of the trapped proton and electron doses and with LET spectra measured by plastic nuclear track detectors. The predicted vs observed comparisons indicate some of the uncertainties of present ionizing radiation environment models for low Earth-orbit missions.

LDEF Project↗

Effects of proton and gamma radiation on lymphocyte populations and acute response to antigen

BACKGROUND: The clinical use of proton radiation in the management of cancer, as well as benign disorders, is rapidly increasing. The major goal of this study was to compare the effects of proton and gamma (60Co) radiation on cell-mediated and humoral immunological parameters. MATERIALS AND METHODS: C57BL/6 mice were exposed to a single dose of 3 Gray (Gy) protons or gamma-rays and intraperitoneally injected 1 day later with sheep red blood cells (sRBC). On 4, 10, 15, and 29 days after exposure, subsets from each group were euthanised; nonirradiated controls (with and without sRBC injection) were included. Body and relative spleen weights, leukocyte counts, spontaneous blastogenesis, lymphocyte populations, and anti-sRBC titers were evaluated. RESULTS: The data showed significant depression (p < 0.05) in nearly all assays on days 4 and 10 after irradiation. B lymphocytes (CD19+) were the most radiosensitive, although reconstitution back to normal levels was observed by day 15. T cell (CD3+) and T helper cell (CD4+) recovery was evident by day 29, whereas the T cytotoxic cell (CD8+) count remained significantly below normal. Natural killer cells (NK1.1+) were relatively radioresistant. Anti-sRBC antibody production was slow and low titers were obtained after irradiation. No significant differences were noted between the two types of radiation. CONCLUSIONS: Taken together, the data show that whole-body irradiation with protons or gamma-rays, at the dose employed, results in marked, but transient, immunosuppression. However, at the time points of testing and with the assays used, little or no differences were found between the two forms of radiation.

NASA Discipline Radiation Health↗

Thermoluminescence and Antarctic meteorites

The level of natural thermoluminescence (TL) in meteorites is the result of competition between build-up, due to exposure to cosmic radiation, and thermal decay. Antarctic meteorites tend to have lower natural TL than non-Antarctic meteorites because of their generally larger terrestrial ages. However, since a few observed falls have low TL due to a recent heating event, such as passage within approximately 0.7 astronomical units of the Sun, this could also be the case for some Antarctic meteorites. Dose rate variations due to shielding, heating during atmospheric passage, and anomalous fading also cause natural TL variations, but the effects are either relatively small, occur infrequently, or can be experimentally circumvented. The TL sensitivity of meteorites reflects the abundance and nature of the feldspar. Thus intense shock, which destroys feldspar, causes the TL sensitivity to decrease by 1 to 2 orders of magnitude, while metamorphism, which generates feldspar through the devitrification of glass, causes TL sensitivity to increase by a factor of approximately 10000. The TL-metamorphism relationship is particularly strong for the lowest levels of metamorphism. The order-disorder transformation in feldspar also affect the TL emission characteristics and thus TL provides a means of paleothermometry.

Sears, D. W. G.↗