Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Verification Problems for Smooth Step Amplitude Load Curves in DYNA3D/Paradyn

This report documents the addition of three new verification tests in the LOADCURVE directory of the DYNA3D/Paradyn Software Quality Assurance test suite. Each test consists of a single element, where the velocities of each node are specified by either the newly added smooth step tabular load curve or another load curve option. The first test assesses the initialization and interpolation of the newly inputted load curve option through tabulated abscissa-ordinate pairs of data. The second test uses the same set of abscissa-ordinate data points and applies offset and scaling parameters available within the load curve definition. The third test defines the smooth step load curve in an original input deck, and assesses its correct redefinition using a restart file. The simulation velocities are compared to their true values at discrete points in time, and each test is verified up to numerical precision. These results confirm that the smooth step load curve option is functioning correctly and as intended.

97 MATHEMATICS AND COMPUTING↗

Heavy and Overweight Vehicle Brake Testing: Five-Axle Combination Tractor-Flatbed (Final Report)

The Federal Motor Carrier Safety Administration, in coordination with the Federal Highway Administration, sponsored the Heavy and Overweight Vehicle Brake Testing (HOVBT) program in order to provide information about the effect of gross vehicle weight (GVW) on braking performance. Because the Federal Motor Carrier Safety Regulations limit the number of braking system defects that may exist for a vehicle to be allowed to operate on the roadways, the examination of the effect of brake defects on brake performance for increased loads is also relevant. The HOVBT program seeks to provide relevant information to policy makers responsible for establishing load limits, beginning with providing test data for a combination tractor/trailer. This testing was conducted on a five-axle combination vehicle with tractor brakes meeting the Reduced Stopping Distance requirement rulemaking. This report provides a summary of the testing activities, the results of various analyses of the data, and recommendations for future research. Following a complete brake rebuild, instrumentation, and brake burnish, stopping tests were performed from 20 and 40 mph with various brake application pressures (15 psi, 25 psi, 35 psi, 45 psi, 55 psi, and full system pressure). These tests were conducted for various brake conditions at the following GVWs: 60,000, 80,000, 91,000, 97,000, 106,000, and 116,000 lb. The 80,000-lb GVWs included both balanced and unbalanced loads. The condition of the braking system was also varied. To introduce these defects, brakes (none, forward drive axle, or rear trailer axle) were made inoperative. In addition to the stopping tests, performance-based brake tests were conducted for the various loading and brake conditions. Analysis of the stopping test data showed the stopping distance to increase with load (as expected) and also showed that more braking force was generated by the drive axle brakes than the trailer axle brakes. The constant-pressure stopping test data revealed a linear relationship between brake application pressure and was used to develop an algorithm to normalize stopping data for weight and initial speed.

air brakes↗

MELT RATE ENHANCEMENT FOR HIGH ALUMINUM HLW (HIGH LEVEL WASTE) GLASS FORMULATION FINAL REPORT 08R1360-1

This report describes the development and testing of new glass formulations for high aluminum waste streams that achieve high waste loadings while maintaining high processing rates. The testing was based on the compositions of Hanford High Level Waste (HLW) with limiting concentrations of aluminum specified by the Office of River Protection (ORP). The testing identified glass formulations that optimize waste loading and waste processing rate while meeting all processing and product quality requirements. The work included preparation and characterization of crucible melts and small scale melt rate screening tests. The results were used to select compositions for subsequent testing in a DuraMelter 100 (DM100) system. These tests were used to determine processing rates for the selected formulations as well as to examine the effects of increased glass processing temperature, and the form of aluminum in the waste simulant. Finally, one of the formulations was selected for large-scale confirmatory testing on the HLW Pilot Melter (DM1200), which is a one third scale prototype of the Hanford Tank Waste Treatment and Immobilization Plant (WTP) HLW melter and off-gas treatment system. This work builds on previous work performed at the Vitreous State Laboratory (VSL) for Department of Energy (DOE) to increase waste loading and processing rates for high-iron HLW waste streams as well as previous tests conducted for ORP on the same high-aluminum waste composition used in the present work and other Hanford HLW compositions. The scope of this study was outlined in a Test Plan that was prepared in response to an ORP-supplied statement of work. It is currently estimated that the number of HLW canisters to be produced in the WTP is about 13,500 (equivalent to 40,500 MT glass). This estimate is based upon the inventory of the tank wastes, the anticipated performance of the sludge treatment processes, and current understanding of the capability of the borosilicate glass waste form. The WTP HLW melter design, unlike earlier DOE melter designs, incorporates an active glass bubbler system. The bubblers create active glass pool convection and thereby improve heat transfer and glass melting rate. The WTP HLW melter has a glass surface area of 3.75 m{sup 2} and depth of {approx}1.1 m. The two melters in the HLW facility together are designed to produce up to 7.5 MT of glass per day at 100% availability. Further increases in HLW waste processing rates can potentially be achieved by increasing the melter operating temperature above 1150 C and by increasing the waste loading in the glass product. Increasing the waste loading also has the added benefit of decreasing the number of canisters for storage. The current estimates and glass formulation efforts have been conservative in terms of achievable waste loadings. These formulations have been specified to ensure that the glasses are homogenous, contain essentially no crystalline phases, are processable in joule-heated, ceramic-lined melters and meet WTP Contract terms. The WTP's overall mission will require the immobilization of tank waste compositions that are dominated by mixtures of aluminum (Al), chromium (Cr), bismuth (Bi), iron (Fe), phosphorous (P), zirconium (Zr), and sulfur (S) compounds as waste-limiting components. Glass compositions for these waste mixtures have been developed based upon previous experience and current glass property models. Recently, DOE has initiated a testing program to develop and characterize HLW glasses with higher waste loadings. Results of this work have demonstrated the feasibility of increases in wasteloading from about 25 wt% to 33-50 wt% (based on oxide loading) in the glass depending on the waste stream. It is expected that these higher waste loading glasses will reduce the HLW canister production requirement by about 25% or more.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cristallini Material Review and Selection

The creation of a handheld unit to utilize the Cristallini method of uranium hexafluoride sampling requires the identification and qualification of suitable substrate materials. These materials will need to quickly and completely react with the process gas, resist vapor locking under vacuum, while being relatively inexpensive and homogeneous. Two forms of powdered alumina have been chosen for a head-to-head comparison during upcoming uranium hexafluoride tests. Both materials have shown ideal uptake characteristics during tungsten hexafluoride tests with a high loading capacity and no measureable breakthrough. They have also been shown to work well at vacuums below 10 Torr, are commercially available and inexpensive. In addition, two possible hydrogen fluoride trapping materials, sodium fluoride and saturated calcium carbonate, have been identified for further testing.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Partial Shade Stress Test for Thin-Film Photovoltaic Modules: Preprint

Partial shade of monolithic thin-film PV modules can cause reverse-bias conditions leading to permanent damage. In this work, we propose a partial shade stress test for thin-film PV modules that quantifies permanent performance loss. We designed the test with the aid of a computer model that predicts the local voltage, current and temperature stress that result from partial shade. The model predicts the module-scale interactions among the illumination pattern, the electrical properties of the photovoltaic material and the thermal properties of the module package. The test reproduces shading and loading conditions that may occur in the field. It accounts for reversible light-induced performance changes and for additional stress that may be introduced by light-enhanced reverse breakdown. We present simulated and experimental results from the application of the proposed test.

14 SOLAR ENERGY↗

Microstructure and Mechanical Properties of Three-Layer TIG-Welded 2219 Aluminum Alloys with Dissimilar Heat Treatments

2219-C10S and 2219-CYS aluminum alloys are 2219 aluminum alloys with different heat treatment processes, and they have been widely used in the aerospace industry. In the present study, 2219-C10S and 2219-CYS aluminum alloys were butt-welded by three-layer tungsten inert gas arc welding (with the welding center of the third layer shifted toward the CYS side), and the microstructure characteristics and mechanical properties of the welded joint were investigated. The lamellar θ′ phases, the bulk or rod θ phases, and the coarse rod-shaped or pancake-shaped Al-Cu-Fe-Mn phases coexisted in the two aluminum alloys. The Cu content of the α-Al matrix and the distribution of eutectic structures of different welding layers in the weld zone (WZ) were varied, implying that the segregation degrees of the Cu element were different due to the different welding thermal cycles in different welding layers. The microhardness values of the CYS side were much higher than those of the C10S side in each region on both sides of the joint. The tensile test deformation was concentrated mainly in the regions of WZ and the over aged zone (OAZ), where the microhardness values were relatively low. The main deformation concentrated region was transferred from the CYS side to the C10S side with the increase in the tensile load during the tensile test. The fracture behavior of the tensile test showed that the macroscopic crack initiated near the front weld toe had gone through the crack blunt region, the shear fracture region of the partially melted zone (PMZ), and the shear fracture region of OAZ. Meanwhile, the fracture characteristics gradually evolved from brittle to ductile. The concentrated stress and the dense eutectic structure in the region near the front weld toe of the C10S side contributed to the fracture of the joint. The shift of the welding center of the third layer to the CYS side resulted in two effects: (i) the microhardness values from the middle layer to the top layer in the PMZ of the CYS side were the most significantly increased and (ii) the distance between the front weld toe and the fusion line of the CYS side was significantly larger.

36 MATERIALS SCIENCE↗

Rapid Load Transition for Integrated Solid Oxide Fuel Cell - Gas Turbine (SOFC-GT) Energy Systems: A Demonstration of the Potential for Grid Response

Rapid load transition is an essential requirement for integrated energy systems to maintain grid resilience as more renewable resources are added to the grid. Integrated solid oxide fuel cell - gas turbine (SOFC-GT) systems can provide high efficiency and low carbon emissions over a broad range of turndown. These hybrids also have the potential to enable rapid grid response. The challenge has been to demonstrate effective control strategies to manage load transitions. In the present study, a load transition of ~50% was achieved in 10 s using a novel but simple strategy. Power demand on the SOFC and the GT were ramped down concurrently. During this transition, the SOFC anode fuel was manipulated to maintain SOFC fuel utilization while the cathode inlet air flow and temperature were also manipulated to thermally protect the SOFC. This study was conducted using the Hybrid Performance (Hyper) facility at the National Energy Technology Laboratory (NETL) in a co-simulation environment with the Idaho National Laboratory (INL)'s grid-simulation. The load ramping strategy was tested using a hardware-based cyber-physical simulation methodology. The results demonstrate a high-fidelity representation of SOFC-GT hybrid dynamics and validation of the control strategy. Thermal and electrochemical transients indicated that the SOFC was well protected during rapid load turndown without violating operability constraints. This demonstration revealed the non-linear nature of tightly coupled SOFC-GT system components, especially the non-linear response of SOFC cathode air flow and inlet temperature controls. These results highlight the needs and challenges in developing adaptive automatic controls for autonomous rapid load transitions. This work demonstrates that SOFC-GT hybrids are a viable option to provide the fast-ramping characteristics essential to accommodate high levels of variable renewable power while maintaining grid resilience, reliability, and environmental performance. The results also demonstrate the utility of co-simulation in advancing the tightly-coupled integrated energy systems needed to meet goals for zero-carbon power generation.

DIRECT ENERGY CONVERSION,POWER TRANSMISSION AND DI↗

Verification of Spent Fuel Inside Dry Storage Casks by Fast/Epi-thermal Neutron Mapping (FY2022 NA-241 Annual Report)

Development of a spent-fuel verification method based upon positional measurement of fast neutrons emitted from the top surface of the dry storage casks. A proof-of-principle field test on a partially loaded spent-fuel cask will be conducted by measuring the fast neutron flux on the top of the cask as a function of position using a single detector. If a useful verification signature is demonstrated, a multidetector scanning array will be built and tested to demonstrate a practical rapid verification system.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

24.1.3.1 - Verification of Spent Fuel Inside Dry Storage Casks by Fast/Epi-thermal Neutron Mapping

Development of a spent-fuel verification method based upon positional measurement of fast neutrons emitted from the top surface of the dry storage casks. A proof-of-principle field test on a partially loaded spent-fuel cask will be conducted by measuring the fast neutron flux on the top of the cask as a function of position using a single detector. If a useful verification signature is demonstrated, a multi-detector scanning array will be built and tested in FY2021 to demonstrate a practical rapid verification system in FY2022.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Verification of Spent Fuel Inside Dry Storage Casks Using Neutron Mapping (2022 Midyear Report)

Development of a spent-fuel verification method based upon positional measurement of fast neutrons emitted from the top surface of the dry storage casks. A proof-of-principle field test on a partially loaded spent-fuel cask will be conducted by measuring the fast neutron flux on the top of the cask as a function of position using a single detector. If a useful verification signature is demonstrated, a multi-detector scanning array will be built and tested to demonstrate a practical rapid verification system.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Implications of Low Particulate Matter Emissions on System Fuel Efficiency for High Efficiency Clean Combustion

Advanced diesel combustion regimes such as High Efficiency Clean Combustion (HECC) offer the benefits of reduced engine out NOX and particulate matter (PM) emissions. Lower PM emissions during advanced combustion reduce the demand on diesel particulate filters (DPFs) and can, thereby, reduce the fuel penalty associated with DPF regeneration. In this study, a SiC DPF was loaded and regenerated on a 1.7-liter 4-cylinder diesel engine operated in conventional and advanced combustion modes at different speed and load conditions. A diesel oxidation catalyst (DOC) and a lean NOX trap (LNT) were also installed in the exhaust stream. Five steady-state speed and load conditions were weighted to estimate Federal Test Procedure (FTP) fuel efficiency. The DPF was loaded using lean-rich cycling with frequencies that resulted in similar levels of NOX emissions downstream of the LNT. The pressure drop across the DPF was measured at a standard point (1500 rpm, 5.0 bar) before and after loading, and a P rise rate was determined for comparison between conventional and advanced combustion modes. Higher PM emissions in conventional combustion resulted in a higher rate of backpressure rise across the DPF at all of the load points leading to more frequent DPF regenerations and higher fuel penalty. The fuel penalty during conventional combustion was 4.2% compared with 3.1% for a mixture of conventional and advanced modes.

33 ADVANCED PROPULSION SYSTEMS↗

Design and validation of a cold load for characterization of cosmic microwave background stage 4 detectors

We present the design and validation of a variable temperature cryogenic blackbody source, hereinafter called a cold load, that will be used to characterize detectors to be deployed by cosmic microwave background stage 4 (CMB-S4), the next-generation ground-based cosmic microwave background (CMB) experiment. Although cold loads have been used for detector characterization by previous CMB experiments, this cold load has three innovative design features: (1) the ability to operate from the 1-K stage of a dilution refrigerator (DR), (2) a He3 gas-gap heat switch to reduce cooling time, and (3) the ability to couple small external optical signals to measure detector optical time constants under low optical loading. The efficacy of this design was validated using a 150-GHz detector array previously deployed by the Spider experiment. Thermal tests showed that the cold load can be heated to temperatures required for characterizing CMB-S4’s detectors without significantly impacting the temperatures of other cryogenic stages when mounted to the DR’s 1-K stage. In addition, optical tests demonstrated that external signals can be coupled to a detector array through the cold load without imparting a significant optical load on the detectors, which will enable measurements of the CMB-S4 detectors’ optical time constants.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Human Factors Evaluation of Energy Visualization Dashboards

Energy visualization systems provide information about use in real-time to assist users with energy efficiency. In this study, three energy visualization dashboards for small businesses were developed and tested. Performance measurement, NASA Task Load Index (TLX) workload assessment, and posttest survey were used to conduct the usability testing. Compared with the dashboards that were designed using line charts and tables, a dashboard designed using visuals (e.g., gauges, pie charts, and flashing lights) produced quicker response time, lower mental and temporal demand and effort ratings, and higher ratings of engagement, interest, and trustworthiness.

Nimbarte, Ashish D. (ORCID:0000000210599112)↗

Spherical Platen versus Flat Platens in Compression Testing of PBX 9502

For ~15 years and perhaps longer, Pantex Plant has used a spherical platen in their compression load train when performing compression tests for Core Surveillance and HE Qualification. As our mechanical testing team at Los Alamos National Laboratory has always worked closely with our Pantex colleagues, and has maintained very similar practices in terms of calibration and testing, the author of this report has documented discussions with Pantex personnel (Robert Spence, et al.) dating back to ~2003, discussing the pros and cons of spherical platen use. LANL used spherical platens for a year or two, but determined issues and discontinued the practice. Based on multiple Engineering Evaluations (EE), LANL opportunities to watch Pantex procedures, it is our understanding that Pantex continued to use spherical platens from circa 2003 (or earlier) through summer 2019, despite the discontinued practice at LANL and the strong encouragement from LANL that spherical platens introduced error and should not be used. The short study reported here was intended to provide quantitative argument as to why spherical platens should not be used. As of a mechanical testing EE in August 2019, and after the testing of this LANL study was complete, LANL was informed by Pantex personnel that the practice of using spherical platens had recently been discontinued with no obvious problems or changes to the quality of the data. Although the urgency is gone for reporting our results, this is a brief quick summary of the data we collected.

42 ENGINEERING↗

Development of Performance Validation Tool for the NPCS for APR1400

Availability of nuclear power plant is highly dependent on the quality of major control systems including NSSS Control Systems. It has been experienced that a small flaw hidden among the control functions resulted in large operational transient or even reactor trip. The proactive quality control of these systems is not easy because of the dynamical characteristics of control algorithms. In a stand-alone or open loop state, it is not possible to perform integral system tests because they need control loads to form an appropriate closed control loop. In the construction plant, Power Ascension Test (PAT) is the first chance to witness the overall performance of the control systems. Because the PAT is the last activity of plant construction schedule, the cost of corrective actions is very high if any functional defect is found in this stage. To minimize risk caused by late detection of control system defects, we developed a validation tool as a proactive test device for the NSSS Process Control System (NPCS) for the SKN Unit 3 which is the first APR1400 plant in Korea. In this paper, the features of the dynamic performance test tool, test methodology, and the test results are described.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Hardware-in-the-Loop Experimental Testbed Using Air Conditioners for Grid Balancing

Driven by the need to offset the variability of renewable generation on the grid, development of load control is a highly active field of research. However, practical use of residential loads for grid balancing remains rare, in part due to the cost of communicating with large numbers of small loads and also the limited experimentation done so far to demonstrate reliable operation. To establish a basis for the safe and reliable use of fleets of compressor loads as distributed energy resources, we constructed an experimental testbed in a laboratory, so that load coordination schemes could be tested at extreme conditions. Here, this experimental testbed was used to tune a simulation testbed to which it was then linked, thereby augmenting the effective size of the fleet. Modeling of the system was done both to demonstrate the experimental testbed's behavior and also to understand how to tune the behavior of each load. Implementing this testbed has enabled rapid turnaround of experiments on various load control algorithms, and year-round testing without the constraints and limitations arising in seasonal field tests with real houses. Experimental results show the practical feasibility of an ensemble of small loads contributing to grid balancing.

Air Conditioners↗

Design and validation of a cold load for characterization of CMB-S4 detectors

We present the design and validation of a variable temperature cryogenic blackbody source, hereinafter called a cold load, that will be used to characterize detectors to be deployed by CMB-S4, the next-generation ground-based cosmic microwave background (CMB) experiment. Although cold loads have been used for detector characterization by previous CMB experiments, this cold load has three novel design features: (1) the ability to operate from the 1 K stage of a dilution refrigerator (DR), (2) a 3He gas-gap heat switch to reduce cooling time, and (3) the ability to couple small external optical signals to measure detector optical time constants under low optical loading. The efficacy of this design was validated using a 150 GHz detector array previously deployed by the Spider experiment. Here, thermal tests showed that the cold load can be heated to temperatures required for characterizing CMB-S4’s detectors without significantly impacting the temperatures of other cryogenic stages when mounted to the DR’s 1 K stage. Additionally, optical tests demonstrated that external signals can be coupled to a detector array through the cold load without imparting a significant optical load on the detectors, which will enable measurements of the CMB-S4 detectors’ optical time constants.

47 OTHER INSTRUMENTATION↗

Results of FY 2023 Alloy 617 and Alloy 709 High-Temperature Crack-Growth Testing

This report summarizes the work performed at Idaho National Laboratory under the “Creep, fatigue and creep-fatigue crack growth tests” task of the “Long-Term VHTR Material Qualification – INL” work package. Work was performed this year to validate the crack growth monitoring setup used with the test frames against both continuous crack length monitoring using an optical camera, as well as post-mortem analysis of marker bands on the fracture surface. Delays prevented the use of a gauge to measure load-line displacement for early tests, and so the creep-fatigue crack growth setup was evaluated using the actuator displacement for a load-line displacement setup. While not ideal, this allowed examination of the shortcomings with the current software setup that was originally designed for performing stress corrosion crack growth rate studies. The method for data collection was modified to link the crack growth monitoring software with Instron’s Wave Matrix software. Once the load-line displacement gauge arrived, the crack growth equipment was successfully modified to permit continuous monitoring of both load-line displacement and crack length. This is critical for creep-fatigue and creep crack growth rate studies for ductile material, as it permits the C* and Ct analyses. Test results are shown for Alloy 617 fatigue and creep-fatigue (without the gauge for load-line displacement measurements), as well as creep-fatigue of Alloy 709, which was performed with the completed test setup, allowing for crack length and load-line displacement monitoring.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗