Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load shift”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Cardiovascular function in space flight

Postflight orthostatic intolerance and cardiac hemodynamics associated with manned space flight have been investigated on seven STS missions. Orthostatic heart rates appear to be influenced by the mission duration. The rates increase during the first 7-10 days of flight and recover partially after that. Fluid loading is used as a countermeasure to the postflight orthostatic intolerance. The carotid baroreceptor function shows only slight responsiveness to orthostatic stimulation. Plots of the baroreceptor function are presented. It is concluded that an early adaptation to the space flight conditions involves a fluid shift and that the subsequent alterations in the neutral controlling mechanisms contribute to the orthoststic intolerance.

Nicogossian, A. E.↗

Techniques for measurement of thoracoabdominal asynchrony

Respiratory motion measured by respiratory inductance plethysmography often deviates from the sinusoidal pattern assumed in the traditional Lissajous figure (loop) analysis used to determine thoraco-abdominal asynchrony, or phase angle phi. We investigated six different time-domain methods of measuring phi, using simulated data with sinusoidal and triangular waveforms, phase shifts of 0-135 degrees, and 10% noise. The techniques were then used on data from 11 lightly anesthetized rhesus monkeys (Macaca mulatta; 7.6 +/- 0.8 kg; 5.7 +/- 0.5 years old), instrumented with a respiratory inductive plethysmograph, and subjected to increasing levels of inspiratory resistive loading ranging from 5-1,000 cmH(2)O. L(-1). sec(-1).The best results were obtained from cross-correlation and maximum linear correlation, with errors less than approximately 5 degrees from the actual phase angle in the simulated data. The worst performance was produced by the loop analysis, which in some cases was in error by more than 30 degrees. Compared to correlation, other analysis techniques performed at an intermediate level. Maximum linear correlation and cross-correlation produced similar results on the data collected from monkeys (SD of the difference, 4.1 degrees ) but all other techniques had a high SD of the difference compared to the correlation techniques.We conclude that phase angles are best measured using cross-correlation or maximum linear correlation, techniques that are independent of waveform shape, and robust in the presence of noise. Copyright 2002 Wiley-Liss, Inc.

Non-NASA Center↗

Resilience of terrestrial and aquatic fauna to historical and future wildfire regimes in western North America

Wildfires in many western North American forests are becoming more frequent, larger, and severe, with changed seasonal patterns. In response, coniferous forest ecosystems will transition toward dominance by fire-adapted hardwoods, shrubs, meadows, and grasslands, which may benefit some faunal communities, but not others. We describe factors that limit and promote faunal resilience to shifting wildfire regimes for terrestrial and aquatic ecosystems. We highlight the potential value of interspersed nonforest patches to terrestrial wildlife. Similarly, we review watershed thresholds and factors that control the resilience of aquatic ecosystems to wildfire, mediated by thermal changes and chemical, debris, and sediment loadings. We present a 2-dimensional life history framework to describe temporal and spatial life history traits that species use to resist wildfire effects or to recover after wildfire disturbance at a metapopulation scale. The role of fire refuge is explored for metapopulations of species. In aquatic systems, recovery of assemblages postfire may be faster for smaller fires where unburned tributary basins or instream structures provide refuge from debris and sediment flows. We envision that more-frequent, lower-severity fires will favor opportunistic species and that less-frequent high-severity fires will favor better competitors. Along the spatial dimension, we hypothesize that fire regimes that are predictable and generate burned patches in close proximity to refuge will favor species that move to refuges and later recolonize, whereas fire regimes that tend to generate less-severely burned patches may favor species that shelter in place. Looking beyond the trees to forest fauna, we consider mitigation options to enhance resilience and buy time for species facing a no-analog future.

54 ENVIRONMENTAL SCIENCES↗

Groundwater Inflows to the Columbia River Along the Hanford Reach and Associated Nitrate Concentrations

Healthy river ecosystems require the interaction of many physical and biological processes to maintain their status. One physical process supporting biogeochemical cycling is hydrologic exchange (i.e., hydrologic exchange flows, HEFs) between relatively fast-flowing channel waters and slower-flowing surface and subsurface waters (lateral and vertical). Land uses adjacent to rivers have the potential to alter the water quality of off-channel surface and subsurface waters, and HEFs therefore have the potential to deliver solutes associated with river-adjacent land uses to rivers. HEFs can be nonpoint, diffuse sources of pollution, making the ultimate pollution source difficult to identify, especially in large rivers. Here, we seek to identify HEFs in the Columbia River near Richland, WA by looking for anomalies in temperature and electrical conductivity (EC) along the bed of the river in February, June, July, August, and November 2018. These are ultimately the “ends” of HEFs as they are locations of subsurface inflow to the river. We found these anomalies to be a combination of warmer or colder and higher (but not lower) EC than river water. We identified a majority of warm anomalies in February and July 2018, and majority cold anomalies in June, August, and November 2018. High-EC anomalies were found mostly in February, August, and November. Combined, we observe a shift from warm, high EC anomalies dominating in February to equivalent EC, warm anomalies in June, to equivalent EC, cool anomalies dominating July. In August, we also measured dissolved nitrate ($NO^-_3$) in-situ to determine whether anomalies were associated with increased $NO^-_3$ loading to the river, especially along the eastern shoreline, which is dominated by agricultural land use. Inflows along the eastern shoreline have greater concentrations of nitrate than river water (up to 10 mg $N–NO^-_3$/L). This research demonstrates that HEFs are temporally and spatially dynamic transferring heat and solutes to rivers.

54 ENVIRONMENTAL SCIENCES↗

Mechanisms of fatigue damage in boron/aluminum composites

Tensile fatigue tests were conducted on several laminates of boron/aluminum (6061-0). In laminates with 0 deg fibers on the outside, an analysis that identifies "shakedown" conditions predicted the stress amplitude below which no fatigue damage accumulated. A fatigue damage accumulation model which relates matrix fatigue cracking and the overall laminate properties is described. A model for the saturation damage stage development is presented, that identical laminates, tested in directions 90 deg apart (such that one layup has 90 deg outer plies and the other 0 deg), have different fatigue behaviors due to the stacking sequence. The 90 deg plies on the surface develop cracks earlier than predicted by shakedown. An attempt was made to explain this stacking sequence effect. Variable load history effects on the fatigue damage response were investigated. Tests reveal that for a given stress ratio the specimen seeks the saturation damage state for the largest stress range to which it is subjected. It was also found that little damage is generated by shifting a given stress range down, whereas significant damage may be created by shifting it upward. The laminate stresses were always tensile.

Johnson, W. S.↗

Lunar gravity - Apollo 17

Gravity results are displayed as a band of contours about 60 km wide spanning 140 deg of frontside longitude. The contours traverse Grimaldi, Mare Procellarum, Copernicus, Apennines, Mare Serenitatis, Littrow, and Mare Crisium. Redundant gravity areas previously mapped by Apollos 14, 15, 16, and the Apollo subsatellites are tabulated and show excellent consistency. Modeling of Grimaldi reveals a loading greater than the known mascons and thus makes Grimaldi the smallest known mascon feature. Copernicus' gravity profile is best modeled with a mass defect for the basin and a mass excess for the rim. Mare Serenitatis has an irregular mass distribution with central gravity highs shifted approximately 3 deg in latitude.

Sjogren, W. L.↗

Effects of Mass-Loading Variations and Applied Moments on Motion and Control of a Manned Rotating Space Vehicle

An analytical study has been made to determine the effects of mass-loading variations and onboard rotating machinery on a hypothetical earth-satellite space station, rotating to provide an artificial gravity equal to one-fourth of that at the earth's surface. Attempts were also made to damp out or minimize undesirable motions by using mass shifts, constant-rate inertia wheels, or jet-reaction moments. Results obtained indicate that the shifting of masses within the rotating space station could bring about large roll oscillations (plus or minus 100 degrees) or even continuous rolling motions if the craft is rotating about the axis of intermediate moment of inertia. The pitch angles obtained were generally small (less than plus or minus 1 degree). The amplitudes of the roll and pitch oscillations are dependent upon the angle of displacement of the greatest principal axis of inertia from the initial spin axis. In attempting to damp out or minimize undesirable motions, it was found that a constant-rate inertia wheel located on and rotating about the axis about which the craft is rotating (Z-axis) was beneficial in keeping the roll angles relatively small, provided it had a sufficient amount of angular momentum. It was also found that the use of jet-reaction moments was very satisfactory for damping undesirable motions in that the roll oscillations could be damped.

Grantham, William D.↗

Economical Implementation of a Filter Engine in an FPGA

A logic design has been conceived for a field-programmable gate array (FPGA) that would implement a complex system of multiple digital state-space filters. The main innovative aspect of this design lies in providing for reuse of parts of the FPGA hardware to perform different parts of the filter computations at different times, in such a manner as to enable the timely performance of all required computations in the face of limitations on available FPGA hardware resources. The implementation of the digital state-space filter involves matrix vector multiplications, which, in the absence of the present innovation, would ordinarily necessitate some multiplexing of vector elements and/or routing of data flows along multiple paths. The design concept calls for implementing vector registers as shift registers to simplify operand access to multipliers and accumulators, obviating both multiplexing and routing of data along multiple paths. Each vector register would be reused for different parts of a calculation. Outputs would always be drawn from the same register, and inputs would always be loaded into the same register. A simple state machine would control each filter. The output of a given filter would be passed to the next filter, accompanied by a "valid" signal, which would start the state machine of the next filter. Multiple filter modules would share a multiplication/accumulation arithmetic unit. The filter computations would be timed by use of a clock having a frequency high enough, relative to the input and output data rate, to provide enough cycles for matrix and vector arithmetic operations. This design concept could prove beneficial in numerous applications in which digital filters are used and/or vectors are multiplied by coefficient matrices. Examples of such applications include general signal processing, filtering of signals in control systems, processing of geophysical measurements, and medical imaging. For these and other applications, it could be advantageous to combine compact FPGA digital filter implementations with other application-specific logic implementations on single integrated-circuit chips. An FPGA could readily be tailored to implement a variety of filters because the filter coefficients would be loaded into memory at startup.

Kowalski, James E.↗

Smart Ventilation Controls for Occupancy and Auxiliary Fan Use Across U.S. Climates

Smart Ventilation has been developed as a way to reduce the energy associated with ventilation by changing when ventilation happens and how much ventilation occurs at any given time. In high performance buildings with low envelope and appliance related loads, ventilation is becoming a bigger part of the total building energy use and needs to be addressed if performance targets are to be met. This work explores the development and performance of smart ventilation controls based on occupancy and auxiliary fan operation that provide annual dwelling unit ventilation equivalence to ASHRAE Standard 62.2-2016. A prototype high performance home compliant with U.S. DOE Building America Zero Energy Ready program requirements was simulated using the REGCAP tool with and without smart controls across 15 U.S. DOE climate zones. Balanced and unbalanced IAQ fans were independently simulated, and all smart controlled fans had airflows double the reference 62.2-2016 airflow. Three idealized occupancy patterns were examined: 1st shift (a typical daily work/school absence), an extended 1st shift with more time spent out of the home evenings and weekends and 3rd shift (night work). The Occupancy controller turns the IAQ fan off during unoccupied periods, and it resumes ventilation upon their return. While unoccupied, contaminants are allowed to accumulate in the space, because occupants are not exposed to these contaminants. When occupants return home, they are exposed to these higher contaminant concentrations, and the controller increases the ventilation rate sufficiently to ensure equivalence with a continuous IAQ fan. Accounting for pollutant emissions that occur during unoccupied periods (as required by ASHRAE 62.2-2016), sharply distinguishes our occupancy controls from past Demand Controlled Ventilation systems. This new accounting method results in equivalent contaminant exposure, as well as lower reductions in average ventilation rates and lower energy savings. Smart controls were demonstrated that saved HVAC energy (i.e., avoided heating/cooling load, as well as fan energy)—averaging between 6 and 46% of ventilation-related energy use depending on the control strategy and occupancy pattern assumptions. The greatest savings were in the combined Auxiliary Fan + Occupancy control. Energy savings increased with climate heating demand and longer unoccupied time periods. The 3rd shift occupancy pattern had better performance, due to the thermal benefit of reducing the ventilation rate during the cold nighttime hours. This same effect provided a cooling energy benefit in hotter locations for the 1st shift. Overall, savings from occupancy-based smart controls were low, because of the recovery period required after occupants return home, during which the airflow is double the 62.2 reference. This recovery is required to maintain equivalence with the ASHRAE standard. Occupancy-based control performance was improved when combined with sensing auxiliary fans and when providing a pre-occupancy flush out of one- or two-hours. Performance was similarly improved if the ASHRAE Standard were to recognize that pollutant emissions are lower during unoccupied periods, iii allowing a lower target ventilation rate during unoccupied periods (not currently in the standard) (see Full vs. Half AEQ in this report). Finally, over-sized unbalanced fans that are cycled on-and-off by a smart controller (or timer) were found to substantially increase annual average air exchange and energy use relative to a continuous unbalanced fan due to the effects of superposition with natural infiltration.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analyzing Mechanical integrity of Microwave resonant Cavity flowmeter

The microwave resonant cavity flow sensor has been proposed to address the difficulties of measuring high-temperature molten salt flow in reactor vessels. The flow sensor consists of a metallic cylindrical cavity coupled to a microwave waveguide. The cylindrical cavity has one of the flat surfaces thin enough to undergo microscopic deflection due to dynamic pressure of the exerted by the flowing fluid. Deflection of the membrane causes a shift in the microwave resonant frequency. Fluid velocity can be estimated from the calibration curve. The objective of this report is to investigate mechanical integrity of the flowmeter’s membrane. The membrane is a thin stainless-steel circular plate with a clamped edge, subjected to uniform load. By calculating the stress on the plate due to deflection and, comparing the stress to the material ultimate tensile strength and yield strength, it can be estimated if the plate will fail. If the maximum stress is greater than the yield strength, the plate will undergo plastic deformation, and the sensor will be disabled. A stress greater than the ultimate tensile strength will cause the plate to fracture. The stress on the plate was calculated with an analytic closed form solution model, and with COMSOL Structural Mechanics Module which does not involve any approximations. Stresses in both the analytic model and COMSOL numerical model were calculated for stainless steel 316 thin circular plates under room temperature conditions, where the fluid is water. The diameter of the circular plate is approximately one inch, and thickness is 10mil. Fluid flow velocity is in the range from 0.5m/s to 1m/s. The results from the two models are similar. Both the analytic model and COMSOL model showed that maximum stresses on the plate, which are at the radial boundary of the plate, are three orders of magnitude smaller than the yield strength and ultimate tensile strength. This indicates that the sensor is at a low risk of mechanical failure.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

An Experimental Study of the Operating Temperature in a Loop Heat Pipe with Two Evaporators and Two Condensers

This paper presents a comprehensive experimental study of the loop operating temperature in a loop heat pipe (LHP) which has two parallel evaporators and two parallel condensers. In a single evaporator LHP, it is well known that the loop operating temperature is a function of the heat load, the sink temperature and the ambient temperature. The objective of the present study emphasizes on the stability of the loop operating temperature and parameters that affects the loop operation. Tests results show that the loop operating temperature is a function of the total system heat load, sink temperature, ambient temperature, and beat load distribution between the two evaporators. Under most conditions, only one compensation chamber (CC) contains two-phase fluid and controls the loop operating temperature, and the other CC is completely filled with liquid. Moreover, as the test condition changes, control of the loop operating temperature often shifted from one CC to another. In spite of complex interactions between various components, the test loop has demonstrated very robust operation even during fast transients.

Ku, Jentung↗

Assessing the ASME Section III, Division 5, Class A Primary Load Design Rules Against Creep Notch Effects

This report assesses the ASME Section III, Division 5, Subsection HB, Subpart B rules covering the design and construction of high temperature Class A nuclear reactor components for their robustness against creep notch effects. The creep notch effect combines the effect of multiaxial stresses on material creep deformation and damage. This report considers both effects, including the potential for creep mechanism shifts affecting the extrapolation of design data from high stress, short-time experimental data to low stress, long time operating component conditions. The report summarizes the history of and literature on multiaxial creep and surveys the current ASME design rules dealing with multiaxial effects. The report then describes the results of two dedicated numerical studies, one assessing the robustness of the ASME rules against uncertainty in extrapolating from uniaxial creep test data to multiaxial component conditions and a second study examining the potential effects of a mechanism shift from high stress, dislocation-mediated creep to diffusion-dominated creep at lower stresses. The final conclusion of the report is that the ASME rules adequately guard against multiaxial creep failure, though there are several aspects of the Code that could be optimized to provide less over-conservative design predictions or to provide a more consistent design margin as a function of temperature and stress. In a few areas, particularly the potential for mechanism shifts outside the currently-available experimental data, the Code rules should be revaluated as additional experimental data and new modeling and simulation results become available

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Timing the Flames: Geostationary Satellite Detection of Diurnally Shifting Stubble Burning in Northwestern India

Post-monsoon open-field stubble burning in northwestern (NW) India—a key agricultural region known as the “breadbasket”—is a longstanding practice used to clear fields. Satellite observations spanning over two decades have revealed significant upward trends in crop production, vegetative greenness, and the frequency of post-harvest fires, with this last contributing to hazardous air quality during the peak burning season (mid-October to mid-November). Since 2022, thermal anomaly data from Aqua-MODIS and SNPP-VIIRS sensors have shown a sharp decline in reported fire events—an observation that contrasts starkly with the concurrent rise in regional aerosol loading detected from space. This apparent discrepancy became particularly pronounced in 2024–2025, prompting a closer examination using high-temporal-resolution imagery from the Advanced Meteorological Imager (AMI) on the geostationary satellite GEO-KOMPSAT-2A. These observations revealed a clear spike in fire-related signals occurring around and after 4:00 p.m. local time, i.e., outside the typical noon to 2:00 p.m. detection window of the MODIS and VIIRS. A fire detection algorithm exploiting the fire-sensitive shortwave-infrared 3.8 μm signal and its contrast to 11.2 μm infrared observations is designed to adopt AMI observations and applied to its multi-year observations (2019–2025). The resulting fire dataset unambiguously shows a gradual shift in stubble burning activity toward the late afternoon hours beginning in 2022 which is underreported by polar-orbiting satellites. The orbital drift of NASA’s MODIS sensor on the Aqua platform allows detection of some of the gradually shifting fires during afternoon hours, but the MODIS still misses a large number of fires occurring around and after 4 p.m. The AMI’s relatively coarse spatial resolution (~4 km), a consequence of its slant viewing geometry over NW India, imposes inherent limitations on quantifying the full extent of fire occurrences. The operational air quality forecasting models currently assimilate satellite fire detections predominantly captured during early afternoon overpasses of the MODIS and VIIRS. The temporal shift in fire activity complicates such forecast, leading to a substantial underestimation of emissions. Intense stubble burning and the resulting air pollution highlight the need for effective crop residue management practices for mitigating the frequency of open biomass burning and thereby reducing episodic degradation of air quality and its associated public health and economic impacts.

post-monsoon stubble burning; northwestern India;↗

Ultrasonic dispersion determined from mechanical resonance frequency shifts

With standing wave ultrasonic techniques, small changes in phase velocity which result from changes in some external parameter (e.g., temperature or magnetic field) have traditionally been determined by observing shifts in the mechanical resonance frequency of a composite resonator. Some previous investigators have assumed that the fractional change in velocity is equal to the fractional change in frequency. We discuss quantitatively the errors involved in such an approach, showing that it leads to substantial inaccuracies when the loading effect of the transducer(s) cannot be neglected. Substantially improved formulas for determining the dispersion are presented and one of these is shown to be much more accurate than all previous approximations. The results of simulated and actual experiments over wide ranges of dispersion, transducer loading parameter, and frequency are analyzed in order to compare the errors inherent in the various approximations.

Moerner, W. E.↗

Advanced Reactors Integrated Energy System: Thermal Energy Storage Island Design

The main topic of this research is integrated energy systems (IES) designed for pairing industrial thermal energy loads with advanced reactors (ARs). The Idaho National Laboratory (INL) Crosscutting Technology Development IES program and the National Reactor Innovation Center (NRIC) are seeking to develop, design, and construct an AR-IES demonstration platform that couples the thermal output from an AR operating at the INL/NRIC Demonstration of Microreactor Experiments (DOME) test bed in the Experimental Breeder II dome to a variable capacity load emulator (i.e., air-cooled radiator) and sensible thermal energy storage (TES) via a molten salt thermal energy transfer fluid. In the rapidly evolving landscape of energy supply and distribution, flexibility has emerged as a prized attribute, surpassing the traditional notions of stability and baseload generation capability. This shift in priorities is particularly evident in the context of nuclear power plants (NPPs), where adaptability over constant output is becoming more important. As our energy infrastructure and resources embraces the rise of distributed energy generation, the inherent variability in net demand continues to grow. Moreover, the use of nuclear energy as a source of heat for decarbonizing the industrial sector is becoming a very pressing topic. In such environment, advanced NPPs are poised to enter a more competitive energy market, delivering both, flexible electricity and heat. This shift motivates the exploration of TES systems, designed to empower NPPs with nimble responsiveness to market fluctuations, flexible heat delivery capabilities, and redefine their role in the energy field. TES systems offer the unique advantage of storing nuclear energy in its original form as heat, thereby affording unparalleled flexibility in its subsequent utilization.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Performance analysis of novel thermal storage integrated heat pump system in a residential building at the hot climate for demand flexibility

A novel thermal energy storage integrated heat pump system was proposed to reshape the electricity load profile of residential buildings while maintaining thermal comfort. High-fidelity computer simulations are needed for evaluating the feasibility of the proposed system. This study investigates the annual performance of the proposed system through Modelica-based system simulations. A rule-based control strategy was developed to shift the electric demand of a typical single-family house in Atlanta, GA from peak to off-peak hours to utilize the Time-of-Use electricity rate to lower the energy costs for conditioning the building. For comparison, a conventional air-source heat pump system serving the same building was also developed. Simulation results indicate that the proposed system is capable of shifting around 90% of the building's electricity consumption for meeting the thermal demand from peak to off-peak hours on a daily basis. In addition, the annual power consumption and operating cost for running the HVAC system can be reduced by 6% and 34%, respectively, compared with the conventional air-source heat pump.

Shi, Liang↗

Dynamics of ultralight aircraft: Dive recovery of hang gliders

Longitudinal control of a hang glider by weight shift is not always adequate for recovery from a vertical dive. According to Lanchester's phugoid theory, recovery from rest to horizontal flight ought to be possible within a distance equal to three times the height of fall needed to acquire level flight velocity. A hang glider, having a wing loading of 5 kg sq m and capable of developing a lift coefficient of 1.0, should recover to horizontal flight within a vertical distance of about 12 m. The minimum recovery distance can be closely approached if the glider is equipped with a small all-moveable tail surface having sufficient upward deflection.

Jones, R. T.↗

Experimental study of the use of vortex generators to reduce fluctuating pressure loads in shock wave turbulent boundary layer interactions

Fluctuating wall pressure measurements have been made in a separated shock wave/turbulent boundary layer interaction produced by an unswept compression corner in a Mach 5 flow. Wheeler doublet vortex generators were placed 15.8 boundary layer thicknesses upstream of the corner to study their effect on the fluctuating pressure loads produced by the translating separation shock. The vortex generators produced significant three-dimensionality in an otherwise two-dimensional interaction. They reduced the upstream influence and the length of the region of shock motion by 60% and 64%, respectively, decreased the maximum wall pressure rms by 23%, and shifted the fluctuations to a higher frequency band. The maximum fraction of energy in the 100-500 Hz frequency band is decreased by 11%. These changes are due to a fuller boundary layer profile, a weaker separation shock, and increased boundary layer turbulence causing increased separation shock jitter.

Barter, John W.↗