Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “limiting techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Sediment concentration mapping in tidal estuaries

An analytical procedure has been developed that considers the ERTS-1 multispectral scanner as a reflectance spectrophotometer. ADP techniques requiring only very limited computer capability are utilized to search the data defining the spectral reflectance characteristics of a scene on a pixel-by-pixel basis, identify each pixel whose spectral reflectance matches a reference spectrum, and generate maps that identify pixel locations where spectrum matches occur and identify the spectrum that was matched. If the reference spectra are known to represent a specific condition on the ground, a map of the distribution of that condition can be output as a dimensionally accurate overlay to maps of any selected scale. Two applications are described: (1) mapping the distribution of water masses exhibiting specific suspended sediment concentrations; and (2) determining the location and delineation of surface water bodies in the southeastern U. S. The techniques described are being successfully used to map the land area inundated by the 1973 spring flood in the Lower Mississippi River Valley, map sediment distributions in Lake Pontchartrain (in Louisiana) as a result of opening the Bonnet Carre Floodway during the spring flood, and inventory lakes and reservoirs.

Williamson, A. N.↗

Securing Smart Manufacturing: Detection of Cyber-Physical Attacks in CNC-Based Systems

As Industry 4.0 advances, the integration of computer numerical control (CNC) machines and advanced manufacturing technologies is transforming production into smart manufacturing systems that blend physical and digital processes as cyber-physical systems. However, this increased cyber-physical connectivity exposes manufacturing systems to cyber threats that can cause severe operational and financial disruptions. This paper presents a comparative study on cyber attacks and anomaly detection techniques in manufacturing, focusing on network traffic from CNC machines. The data extracted from network packets includes machine commands and control signals exchanged between the machine's interface and control system, crucial for maintaining operational integrity. We explore two types of cyber attacks, design modification and command injection, which pose substantial risks to CNC machine productivity and system integrity. Our investigation involves experiments on a real CNC system, highlighting the urgent need for effective detection mechanisms. To address these threats, we evaluate three anomaly detection methods: dynamic time warping (DTW), rolling average, and a deep learning, long short-term memory (LSTM) time-series-based autoencoder. Each is assessed for its effectiveness in identifying anomalous behaviors caused by the attacks. Our findings demonstrate the unique strengths and limitations of each detection technique, providing a deeper understanding of their applicability in realworld manufacturing environments. The comparative analysis indicates that while certain methods are highly effective against specific attack types, others offer broader applicability across different attacks. This study contributes to the accurate detection of anomalies in CNC machining processes, thereby enhancing the reliability and security of smart manufacturing systems against diverse cyber threats.

Williams, Bethanie [Tennessee Technological Univer↗

Experiment in Onboard Synthetic Aperture Radar Data Processing

Single event upsets (SEUs) are a threat to any computing system running on hardware that has not been physically radiation hardened. In addition to mandating the use of performance-limited, hardened heritage equipment, prior techniques for dealing with the SEU problem often involved hardware-based error detection and correction (EDAC). With limited computing resources, software- based EDAC, or any more elaborate recovery methods, were often not feasible. Synthetic aperture radars (SARs), when operated in the space environment, are interesting due to their relevance to NASAs objectives, but problematic in the sense of producing prodigious amounts of raw data. Prior implementations of the SAR data processing algorithm have been too slow, too computationally intensive, and require too much application memory for onboard execution to be a realistic option when using the type of heritage processing technology described above. This standard C-language implementation of SAR data processing is distributed over many cores of a Tilera Multicore Processor, and employs novel Radiation Hardening by Software (RHBS) techniques designed to protect the component processes (one per core) and their shared application memory from the sort of SEUs expected in the space environment. The source code includes calls to Tilera APIs, and a specialized Tilera compiler is required to produce a Tilera executable. The compiled application reads input data describing the position and orientation of a radar platform, as well as its radar-burst data, over time and writes out processed data in a form that is useful for analysis of the radar observations.

Holland, Matthew↗

Chapter 10 - Remote Sensing Measurements of Aerosol Properties

Satellite instruments have proven especially capable at monitoring the quantity of airborne particles in columns of atmosphere, globally. This chapter describes the principles of satellite measurements and retrieval algorithms, and surveys current instruments and their capabilities. We outline the issues associated with retrieval algorithms, such as surface characterization and aerosol proximity to clouds, and the challenges with interpretation of the results. The relationship between measured aerosol properties and climate-relevant aerosol properties simulated in models is outlined, as well as how measurements are used to evaluate models. Most space-based aerosol instruments are passive sensors that measure reflected sunlight at multiple wavelengths, some at multiple viewing angles. A few are active sensors that send out their own laser light and measure the returned signal. Except when clouds are present, the excess amount of light scattered back to space, beyond that expected from the surface and atmospheric gas, is attributed to aerosol. Satellite measurements are used in many ways in aerosol research. They often provide the only method for monitoring hazardous phenomena such as major wildfire and volcanic eruption plumes, especially in remote areas. Stable, long-term, near-global-scale satellite data records make it possible to identify regional and global aerosol trends. Aerosol radiative effects on climate can be quantified on a near-global scale and used to estimate the strength of aerosol–radiation and aerosol–cloud interactions as well as to evaluate climate model simulations of these interactions. Aerosol-type mapping from satellite imagery is helpful for source attribution, model validation, and to constrain particle light-absorption properties that are essential for radiative forcing calculations. The range of aerosol properties retrieved from satellite observations has grown considerably since the first global estimates of aerosol optical depth (τ a) over ocean were made in the late 1970s. Methods for retrieving particle size and light-absorption properties were explored in the 1990s using multispectral, multi-angle observations, and polarization in visible and near-infrared wavelengths. Sensitivity to particle light absorption, primarily from black or brown carbon content, improved with the inclusion of UV channels, and sensitivity to very thin aerosol layers in the upper troposphere and lower stratosphere was advanced with the use of limb-sounding instruments and active sensors. There are limitations to every measurement technique, including satellite aerosol remote sensing. For wide-swath, passive instruments, aerosol retrievals near clouds can present substantial challenges as far as 15 km away due to cloud-scattered light contaminating the signal. In nearly all cases, retrievals over bright snow and ice surfaces are precluded because surface reflectance uncertainties can overwhelm the aerosol signal. Similarly, meteorological cloud is identified and masked out where possible. Data from passive sensors also lack vertical resolution except those that view toward the limb or where multi-angle imagery is acquired over plumes from wildfires, erupting volcanoes, and wind-blown dust. Yet, passive sensors provide vastly more coverage than the active instruments that mitigate these issues. Particle microphysical information is qualitative from all remote sensing techniques, relying on proxies to infer particle composition, hygroscopicity, and the amount of light-absorbing material. Further, particles smaller than about 200 nm diameter cannot be distinguished from atmospheric gas molecules with remote sensing, which hinders studies of cloud condensation nuclei and their effects on clouds. Most satellite instruments dedicated to aerosol observations are in low-Earth, near-polar, sun-synchronous orbits, which means they cross the equator at the same local time each day. Most are set on cycles that repeat approximately every 16 days, which makes it difficult to monitor aerosol evolution locally. Geostationary satellites make it possible to observe changes occurring from minutes to hours over regions up to 8000 km in size, but lack coverage of high latitudes, and often provide more limited constraints on aerosol properties. Ground-truth data are vital for satellite aerosol-retrieval validation. The AErosol RObotic NETwork (AERONET) of sun photometers was created in 1993 and has become an established global network of over 350 instruments for validating satellite measurements. The network, as well as global networks of ground-based lidars, solar flux radiometers and other sun photometers, are widely used for evaluating global satellite retrievals and model simulations. NASA's Earth Observing System (EOS) program beginning in 1999 led to improvements in reliability, spatial resolution, and spectral resolution (and hence, to improved particle size discrimination and light absorption properties). Satellite payloads include advanced broad-swath and multi-angle imagers, along with the first space-based active sensor focused largely on long-term aerosol monitoring. Since about 2002, Europe's SENTINEL and operational meteorological satellite fleets are also providing sustained aerosol observations, with planned continuation until at least 2030. Satellite remote sensing instruments offer valuable data for evaluating aerosol representations in global climate models. They have been used to assess aerosol optical and physical properties, trends and distributions, and are applied increasingly as direct model constraints in data assimilation to create global aerosol reanalysis products. Aerosol optical depth is the most common quantity adopted for routine model evaluation, including multiwavelength data to loosely constrain particle-size distributions. These evaluations of multiple models have revealed general biases in their regional aerosol amounts and seasonal patterns of transport and removal. Although satellite measurements have near-global coverage, substantial errors can be introduced into the model observation comparison unless attention is paid to spatial and temporal collocation, cloud screening, subgrid-scale variability, and measurement uncertainties that vary with retrieval conditions.

aerosol properties↗

Improvements to the Modeling of the TREAT Reactor and Experiments

This paper summarizes the latest improvements and lessons learned from the modeling and simulation of the transient test reactor at Idaho National Laboratory using the MAM- MOTH reactor physics application. MAMMOTH is a MOOSE-based, Finite Element Method application that specializes in the analysis of the spatial dynamics behavior of nuclear reactors. Since early 2018 several transient tests have been conducted at TREAT, thus providing the opportunity to apply and benchmark modern modeling and simulation tools. MAMMOTH was used to provide predictions of the power coupling factor between the core and the experiment for various experiments. Even though the power coupling factor predictions agree very well with the experimental data, within the bounds of the experimental uncertainty, one shortcoming was the underprediction of the total energy deposited in the core and in the experiment. Determination of the sources for this discrepancy are ongoing, but several key problems have been identified and resolved, thus providing valuable insights for future research. This paper discusses several of these lessons learned. First, the heat capacity data for the TREAT fuel has some significant problems due to limitations of the measurement techniques used circa 1960s. The sensitivity of the peak power and the total energy deposition to various representations of the heat capacity is approximately 5%. Second, the effects of the biological shield and thermal column on the modeling of the core are non-negligible, since they affect the mean generation time and the effective reflection of neutrons back into the core, which is suspected to be important during the core heat up. Matching the reactor period resolves the fact that the reduced spatial domain used in the MAMMOTH model underpredicts the mean generation time. The neutron reflection from these regions is marginally improved with the use of an albedo boundary condition. Third, modeling of the control rod movement with a multi-scheme method is introduced and its current limitations are exposed. Fourth, we explore the effects of using a homogenized model with Superhomogenization equivalence and how that differs from fully heterogeneous simulations. Finally, the energy condensation effects for this graphite core are significant. Solutions with 10 and 26 energy groups show the benefits of using a finer coarse group structure.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Hybrid method for monitoring large Fabry-Pérot cavity displacements with nanometer precision

The change in length of an optical fiber-based Fabry-Pérot cavity (FPC) can be precisely measured using phase tracking, but the displacement range is limited by phase ambiguity. Period tracking techniques determine the absolute FPC length, but with larger uncertainties from tracking the spacing between multiple peaks. A hybrid method is demonstrated that identifies appropriate peaks for phase tracking using a coarse estimate obtained from the free spectral range to effectively maintain the high precision (∼1 nm) of phase tracking techniques to measure ∼24 µ m displacements, well beyond the range limitations (typically <1 µ m) of phase tracking methods.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Microscopy Methods for Life Detection on Ocean Worlds

On Earth, light microscopy is commonly used in microbiology to identify organisms and observe their interactions with the environment; this makes it an attractive technique for in situ life detection methods on ocean worlds. As a standalone technique, brightfield microscopy, while able to provide important contextual information, has limited usefulness as a life detection technique because it is often challenging to differentiate between abiotic and biotic particles based solely on their size and shape, which may introduce risks of false positive or false negative interpretations. However, these risks can be reduced by combining brightfield microscopy with fluorescence microscopy to provide a method that correlate sample chemistry with sample morphology. In this work, we have used the Luminescence Imager for Exploration (LIfE), a brightfield and epifluorescence microscope with an integrated sample processing system (matured under the Concepts for Ocean worlds Life Detection Technology and Instrument Concepts of Europa Exploration programs) to develop methods that increase the fidelity of in situ microscopy life detection measurements through two main approaches. First, native fluorescence is excited in molecules that contain aromatic moieties such as proteins (using deep UV excitation), and energy carrying molecules and endogenous chromophores (using visible-light excitation), to correlate the location of these species with cell-like structural features (brightfield imaging). Second, fluorescent stains are used to selectively image cells and cell fragments by targeting proteins, lipids, and nucleic acids. We discuss the results of tests, obtained using ocean world analog samples, that have examined trades associated with implementing these methods autonomously in planetary missions, including the intrinsic properties of candidate fluorescence dyes and long-term storage and radiation stability.

Pavel E. Z. Klier↗

Microscopy Methods for Life Detection on Ocean Worlds

On Earth, light microscopy is commonly used in microbiology to identify organisms and observe their interactions with the environment; this makes it an attractive technique for in situ life detection methods on ocean worlds. As a standalone technique, brightfield microscopy, while able to provide important contextual information, has limited usefulness as a life detection technique because it is often challenging to differentiate between abiotic and biotic particles based solely on their size and shape, which may introduce risks of false positive or false negative interpretations. However, these risks can be reduced by combining brightfield microscopy with fluorescence microscopy to provide a method that correlate sample chemistry with sample morphology. In this work, we have used the Luminescence Imager for Exploration (LIfE), a brightfield and epifluorescence microscope with an integrated sample processing system (matured under the Concepts for Ocean worlds Life Detection Technology and Instrument Concepts of Europa Exploration programs) to develop methods that increase the fidelity of in situ microscopy life detection measurements through two main approaches. First, native fluorescence is excited in molecules that contain aromatic moieties such as proteins (using deep UV excitation), and energy carrying molecules and endogenous chromophores (using visible-light excitation), to correlate the location of these species with cell-like structural features (brightfield imaging). Second, fluorescent stains are used to selectively image cells and cell fragments by targeting proteins, lipids, and nucleic acids. We discuss the results of tests, obtained using ocean world analog samples, that have examined trades associated with implementing these methods autonomously in planetary missions, including the intrinsic properties of candidate fluorescence dyes and long-term storage and radiation stability.

Pavel E Z Klier↗

Preliminary Assessment of the Use of Heavy Gases in Two-Stage Light Gas Guns

This paper discusses ballistic range testing at muzzle velocities of 0.7 to 2.7 km/s. Herein, we review several techniques for achieving these velocities - starting with the single stage gas gun and the powder gun. These techniques can have velocity limitations, both on the high end and on the low end, very high powder breech pressures, incomplete and inconsistent powder burn and can send unburned powder grains downrange to confound impact data. To try to resolve these issues, it was decided to study the use of the two stage light gas gun operated with a heavier working gas than is normally used. This would have the effect of lowering the usual muzzle velocity range of the two-stage gun using hydrogen to cover the desired low velocity range. Preliminary results are presented from firings with two NASA guns. Twenty-five shots were made with helium and nine shots with argon. Muzzle velocities of 1.1 to 4 km/s were obtained with helium and velocities of 0.7 to 2.7 km/s were obtained with argon. Overall, the heavy gas technique appears quite promising, but more firings are needed to fill out the database.

Bogdanoff, David W.↗

Preliminary Assessment of the Use of Heavy Gases in Two-Stage Light Gas Guns

This paper discusses ballistic range testing at muzzle velocities of 0.7 to 2.7 km/s. Herein, we review several techniques for achieving these velocities - starting with the single stage gas gun and the powder gun. These techniques can have velocity limitations, both on the high end and on the low end, very high powder breech pressures, incomplete and inconsistent powder burn and can send unburned powder grains downrange to confound impact data. To try to resolve these issues, it was decided to study the use of the two stage light gas gun operated with a heavier working gas than is normally used. This would have the effect of lowering the usual muzzle velocity range of the two-stage gun using hydrogen to cover the desired low velocity range. Preliminary results are presented from firings with two NASA guns. Twenty-five shots were made with helium and nine shots with argon. Muzzle velocities of 1.1 to 4 km/s were obtained with helium and velocities of 0.7 to 2.7 km/s were obtained with argon. Overall, the heavy gas technique appears quite promising, but more firings are needed to fill out the data base.

Bogdanoff, David W.↗

Summertime Coincident Observations of Ice Water Path in the Visible/Near-IR, Radar, and Microwave Frequencies

Accurate representation of the physical and radiative properties of clouds in climate models continues to be a challenge. At present, both remote sensing observations and modeling of microphysical properties of clouds rely heavily on parameterizations or assumptions on particle size distribution (PSD) and cloud phase. In this study, we compare Ice Water Path (IWP), an important physical and radiative property that provides the amount of ice present in a cloud column, using measurements obtained via three different retrieval strategies. The datasets we use in this study include Visible/Near-IR IWP from the Moderate Resolution Imaging Spectroradiometer (MODIS) instrument flying aboard the Aqua satellite, Radar-only IWP from the CloudSat instrument operating at 94 GHz, and NOAA/NESDIS operational IWP from the 89 and 157 GHz channels of the Microwave Humidity Sounder (MHS) instrument flying aboard the NOAA-18 satellite. In the Visible/Near-IR, IWP is derived from observations of optical thickness and effective radius. CloudSat IWP is determined from measurements of cloud backscatter and assumed PSD. MHS IWP retrievals depend on scattering measurements at two different, non-water absorbing channels, 89 and 157 GHz. In order to compare IWP obtained from these different techniques and collected at different vertical and horizontal resolutions, we examine summertime cases in the tropics (30S - 30N) when all 3 satellites are within 4 minutes of each other (approximately 1500 km). All measurements are then gridded to a common 15 km x 15 km box determined by MHS. In a grid box comparison, we find CloudSat to report the highest IWP followed by MODIS, followed by MHS. In a statistical comparison, probability density distributions show MHS with the highest frequencies at IWP of 100-1000 g/m(exp 2) and CloudSat with the longest tail reporting IWP of several thousands g/m(exp 2). For IWP greater than 30 g/m(exp 2), MODIS is consistently higher than CloudSat, and it is higher at the lower IWPs but lower at the higher IWPs that overlap with MHS. Some of these differences can be attributed to the limitations of the measuring techniques themselves, but some can result from the assumptions made in the algorithms that generate the IWP product. We investigate this issue by creating categories based on various conditions such as cloud type, precipitation presence, underlying liquid water content, and surface type (land vs. ocean) and by comparing the performance of the IWP products under each condition.

Pittman, Jasna V.↗

Wavenumber-frequency deconvolution of aeroacoustic microphone phased array data of arbitrary coherence

Deconvolution of aeroacoustic data acquired with microphone phased arrays is a computationally-challenging task for distributed sources with arbitrary coherence. A new technique for performing such deconvolution is proposed. This technique relies on analysis of the array data in the wavenumber-frequency domain, allowing for fast convolution and reduced storage requirements when compared to traditional coherent deconvolution. A positive semidefinite constraint for the iterative deconvolution procedure is implemented and shows improved behavior in terms of quantifiable convergence metrics when compared to a standalone covariance inequality constraint. A series of simulations validates the method's ability to resolve coherence and phase angle relationships between partially-coherent sources, as well as determines convergence criteria for deconvolution analysis. Simulations for point sources near the microphone phased array show potential for handling such data in the wavenumber-frequency domain. In particular, a physics-based integration boundary calculation is described, and can successfully isolate sources and track the appropriate integration bounds with and without the presence of flow. Magnitude and phase relationships between multiple sources are successfully extracted. Limitations of the deconvolution technique are determined from the simulations, particularly in the context of a simulated acoustic field in a closed test section wind tunnel with strong boundary layer contamination. A final application to a trailing edge noise experiment conducted in an open-jet wind tunnel matches best estimates of acoustic levels from traditional calculation methods and qualitatively assesses the coherence characteristics of the trailing edge noise source.

phased array↗

Automation of review/approval cycle of MCAUTO CAD/CAM generated drawings and documents

The review/approval of MCAUTO/UNIGRAPHICS CAD/CAM generated drawings and documents is done through routing of hard copies of drawings and memos via mail, a process both time consuming and expensive. It is proposed that a set of procedures and the required software tools be designed for transmission, revision, and signing-off of such documents via electronic data transfer, while maintaining a sufficient degree of data integrity and individual security. A main resistance to such a technique will be the limited size of the display screen (19 inch class) and infrequent layer switching with the attendant time delay during the process of reviewing the drawing. Such opposition should diminish as the users become familiar with the hardwares and its operation. It is suggested that user profiles be set so that the protection class list of the originator of the drawing include at least one common class with each of the individuals who will be involved in the Revision/Approval cycle. In this way the originator will be able to tranfer a file for their review and also be able to copy back the file to make the necessary permanent changes. Individual security is maintained by restricted access to signature files and by restricting the list of individuals who will be authorized to sign off. This is accomplished through two software tools:LAYCOPY and SIGN. It is felt that these proposed procedures and techniques will adequately maintain both the file integrity and individual security during Review/Approval Cycle of MCAUTO generated drawings without the need for hardcopy routing.

Minn, H. S.↗

Mounted Accelerometer Frequency Response of Adhesive Products and Aluminum Frame Quick Mounts

An accelerometer mounting technique has large implications on the frequency range and accuracy of the measurement, with stiffness and the mass relative to the monitored structure as the primary concerns. The International Organization for Standardization (ISO) gives an extensive list in 5348:2021, detailing mounting methods, and provides recommendations for testing mounts that are not specifically defined. In the nuclear industry on the laboratory scale, there is a need for vibration measurements for predictive maintenance and process monitoring that are nondestructive and capable of working in high-temperature environments. Commercial adhesive products with easy application and removal were tested as nondestructive methods, while quick mounts to a commonly used aluminum frame were tested as nondestructive and have potential applicability in high-temperature environments. The sinusoidal excitation method was used, measuring frequencies from 50 Hz to 10 kHz in one-third octave band intervals, utilizing three accelerometers and comparing the results to those obtained with the stud-mounting method. Using the lowest ±3 dB threshold across each accelerometer, foam dots and poster strips were not successful, and foam tapes were accurate up to 2000 Hz, hose clamps and zip ties up to 800 Hz, and a custom 3D printed mount up to 1000 Hz. Knowing the limitations of each mounting technique allows for accurate measurements within the appropriate range.

47 - OTHER INSTRUMENTATION↗

Measurement Capabilities of Single-Pulse Planar Doppler Velocimetry

Preliminary investigations are described of a method that is capable of measuring instantaneous, 3-D, velocity vectors everywhere in a light sheet generated by a pulsed laser. The technique, here called Planar Doppler Velocimetry (PDV), is a variation of a new concept for velocity measurements that was called Doppler Global Velocimetry (DGV) in its original disclosure. The concept relies on the use of a narrowband laser and measurements of the Doppler shift of scattered light from particles moving with a flow. The Doppler shift is recorded as a variation in transmission through a sharp-edged spectral filter provided by iodine vapor in a cell. Entire fields of velocity can be determined by using a solid-state camera to record the intensity variations throughout the field of view. However, the implementation of DGV has been centered principally on the use of high power, continuous-wave, ion lasers and measurement times that are determined by the 30-ms framing times of standard video cameras. Hence, they provide velocity fields that are averaged in time at least over that period. On the other hand, the PDV concept described in this presentation incorporates a high energy, repetitively pulsed, Nd-YAG laser that is injection-seeded to make it narrowband and then frequency-doubled to provide light at frequencies absorbed by the iodine vapor. The duration of each pulse is less than 10 nanoseconds. When used in combination with nonstandard, scientific quality, solid state cameras, a sequence of images can be obtained that provides instantaneous velocity vectors everywhere in the field of view. The investigations described in this paper include an accurate characterization of the iodine cell spectral behavior and its influence on the PDV measurements, a derivation of the PDV signal analysis requirements, and the unique aspects of the pulsed laser behavior related to this application. In addition, PDV measurements are to be demonstrated using data from a rotating wheel target and from the flow of a subsonic jet. Initially, single optical fiber light collection and photomultiplier detectors will be substituted for solid state cameras. Those results will allow the determination of the fundamental limitations of the PDV technique without the complications of image acquisition and processing. They will then be used to provide an analysis of the measurement capabilities of PDV both in small aerodynamic research wind tunnels and in large wind tunnels designed for production airframe and propulsion testing. Future plans include the implementation of solid state cameras and the development of the required image acquisition and processing software. Eventually, the PDV technique will be applied to an aerodynamic research program related to transonic wing flutter.

McKenzie, Robert L.↗

Nuclear Decontamination Evolution and Revolution - 20349

Decontamination, one of the oldest practices in the nuclear industry, is about to change. While no single approach to decontamination is appropriate in all situations, decontamination of highly contaminated surfaces is historically viewed as difficult and/or marginally effective and fixatives and strippable coatings are often called on to manage time sensitive contamination control issues. The deferral of proper decontamination can lead to accumulated concentrations of radioactive material increasing the risk of cross-contamination of workers and equipment while also increasing radiation levels, which further discourages decontamination. The results of the subject testing demonstrate that superior decontamination factors are readily achievable and the ALARA benefit of decontamination is viable through advanced decontamination technologies in conjunction with innovative application techniques. The collateral benefits will save countless radiological man-hours and personnel radiological exposure. The appropriate use of radiological decontamination techniques can prevent or limit the adverse effects of highly radioactive contamination in the work area. High levels of radiological contamination are typically associated with some of the most physically demanding work in the nuclear industry. Additionally, working in highly contaminated environments increases the risk of exposure to elevated levels of airborne radioactivity and radiation from the source term of the contamination, particularly in hard to reach areas or complex equipment. Veolia's Alaron Nuclear Services (Alaron), a fully integrated nuclear facility, has provided the nuclear industry waste treatment, consolidation, repackaging, and broad decontamination services for almost 35 years. In looking at solutions for its customers, as well as for their own facility, Alaron has recently collaborated with Environmental Alternatives, Inc. (EAI), which has provided innovative solutions addressing difficult nuclear decontamination and industrial cleaning challenges since 1989. This broad range of experience along with the products to support the work created an ideal partner for Alaron's needs at their facility. The benefits of collaboration were immediately recognizable to the management of both companies although the decontamination challenge was significant. Due to the nature of the services offered, contamination at the Alaron facility is routine. The recent decontamination experience at Alaron utilized an innovative surfactant process that quickly produces remarkably higher decontamination factors for both removable surface contamination and fixed contamination. Considering the time to decontaminate areas historically designated for high radiological hazard work, the results from this decontamination effort not only reduced contamination levels but also significantly lowered exposure rates in the working environment. The relative ease with which the surfactant is applied, combined with extraordinary decontamination test results, indicates the potential to alter current radiological work processes in a way that improves worker comfort, and removes radiological engineering barriers, allowing Alaron to complete complex radiological tasks more efficiently and effectively. In a series of two simple applications of the decontamination agent to contaminated high bay vertical surfaces, as well as a variety of horizontal and vertical surfaces with variable porousness and surface sealants, there was an overall reduction in removable contamination of approximately 73% with a reduction in area dose of approximately 93%. The results indicate additional reduction in fixed contamination with application of the surfactant. These values are much higher than experienced with more traditional decontamination agents. In conjunction with demonstrating EAI's surfactant on room surfaces, additional studies were conducted on complex geometry equipment including waste processing equipment, tools, and heavily contaminated parts normally handled from Alaron's customers. Evaluations were made with straight application of EAI's surfactant as well as adding additional techniques to the treatment which afforded revolutionary improvements in the levels of contamination removed. Successful decontamination with up to 95% reduction in removable contamination with just one application were demonstrated in several of the trials. This paper outlines the planned approach to use this technology, the variety of surfaces and equipment treated, and the results of the decontamination efforts. Furthermore, this paper discusses options for pretreatment of certain heavily contaminated equipment prior to employees handling and/or working with the equipment. The potential for dose saving and the reduced risk of cross-contamination with the added benefit of lower PPE requirements, produces an enormous potential for cost and time savings. Attendees will benefit from Alaron's experiences and more fully understand the capabilities of EAI's decontamination process. With the variety of contamination agents, forms and surfaces on which the technology was demonstrated, the information will be valuable to a broad cross-section of industry users. The significance of this report demonstrates superior decontamination factors are achievable utilizing the next evolution of decontamination technology and that the ALARA benefits of decontamination are available through advanced and modern decontamination efforts. The collateral benefits will save countless radiological man-hours and valuable personnel radiological exposure. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

[Compton GRO Cycle 7]

The goals of this project were to use the improved location accuracy of combined BATSE/Ulysses-IPN gamma-ray burst (GRB) data to search for small-angle clustering within the burst population and to search for possible correlations between bursts and catalogs of known astrophysical objects. The research was completed in several phases due to the length of time needed to process the basic BATSE/Ulysses data and to develop the appropriate analysis algorithms. In the first phase, BATSE/Ulysses data were gathered from their respective sources and processed to yield, final BATSE burst catalog locations and final BATSE/Ulysses IPN timing annuli. The final data are published. In the next phase, traditional statistical analysis techniques were used to search a subset of the data for small-angle clustering and. correlations, and to produce upper limits. Next, the unique analysis techniques and software described in the proposal were developed and,applied to the final set of data (corresponding to the 4B catalog). The final search did not find any significant self-clustering or correlations with supernovae, AGN, or near by galaxy clusters. The investigation ruled-out earlier findings that indicated (with marginal significance) such results, and. provided stringent limits on the allowable fraction of bursts that are self-clustered and associated with selected known objects. An added benefit of this research came in 1998 when it was suggested that some gamma-ray bursts may be associated with supernova (SN) explosions. We responded rapidly and applied the tools of this investigation to study this possibility. Using combined BATSE/Ulysses data, we were able to completely rule out any association between bright bursts and known supernovae, thereby questioning the validity of any GRB/SN association. If a GRB/SN association exists, it must be only with a small fraction of weak bursts.

Kippen, R. Marc↗

Additive manufacturing of continuous carbon fiber-reinforced SiC ceramic composite with multiple fiber bundles by an extrusion-based technique

Due to the high cost, complex preparation process and difficulty in structural design, the traditional methods for carbon fiber-reinforced SiC ceramic composite preparation have great limitations. This paper presents a technique for the additive manufacturing multiple continuous carbon fiber bundle-reinforced SiC ceramic composite with core-shell structure using an extrusion-based technique. A conventional nozzle system was modified to print simultaneously a water-based SiC paste with continuous carbon fibers. Different levels of binder contents were investigated to optimize the stickiness, viscosity, thixotropy and viscoelasticity of the paste. After sintering, SiC whiskers were generated on the surface of fiber, which is conjectured to be due to the reaction between SiO and carbon fiber at high temperature. The continuous carbon fiber-reinforced SiC ceramic composite exhibited non-brittle fracture. In conclusion, the flexural strength of the additively manufactured Cf/SiC composites improved from 162 MPa with no fiber bundles to a maximum of 219 MPa with three fiber bundles.

36 MATERIALS SCIENCE↗