Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “interferometers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Evaluation of a land-atmosphere coupling metric computed from a ground-based infrared interferometer

Land-atmosphere feedbacks are a critical component of the hydrologic cycle. Vertical profiles of boundary layer temperature and moisture, together with information about the land surface, are used to compute land-atmosphere coupling metrics. Ground based remote sensing platforms, such as the Atmospheric Emitted Radiance Interferometer (AERI), can provide high temporal resolution vertical profiles of temperature and moisture. When co-located with soil moisture, surface flux, and surface meteorological observations, such as at the Atmospheric Radiation Measurement (ARM) Southern Great Plains (SGP) site, it is possible to observe both the terrestrial and atmospheric legs of land-atmosphere feedbacks. In this study, we compare a commonly used coupling metric computed from radiosonde-based data to that obtained from the AERI to characterize the accuracy and uncertainty in the metric derived from the two distinct platforms. This approach demonstrates the AERI’s utility where radiosonde observations are absent in time and/or space. Radiosonde and AERI based observations of the Convective Triggering Potential and Low-Level Humidity Index (CTP-HI low ) were computed during the 1200 UTC observation time and displayed good agreement during both 2017 and 2019 warm seasons. Furthermore, radiosonde and AERI derived metrics diagnosed the same atmospheric preconditioning based upon the CTP-HI low framework a majority of the time. When retrieval uncertainty was considered, even greater agreement was found between radiosonde and AERI derived classification. The AERI’s ability to represent this coupling metric well enabled novel exploration of temporal variability within the overnight period in CTP and HI low . Observations of CTP-HI low computed within a few hours of 1200 UTC were essentially equivalent, however with greater differences in time arose greater differences in CTP and HI low .

54 ENVIRONMENTAL SCIENCES↗

Preliminary Neutronics Analysis of the ITER Toroidal Interferometer and Polarimeter Diagnostic Corner Cube Retroreflectors

ITER is an international project under construction in France that will demonstrate nuclear fusion at a power plant-relevant scale. The Toroidal Interferometer and Polarimeter (TIP) Diagnostic will be used to measure the plasma electron line density along 5 laser-beam chords. This line-averaged density measurement will be input to the ITER feedback-control system. The TIP is considered the primary diagnostic for these measurements, which are needed for basic ITER machine control. Therefore, system reliability & accuracy is a critical element in TIP’s design. There are two major challenges to the reliability of the TIP system. First is the survivability and performance of in-vessel optics and second is maintaining optical alignment over long optical paths and large vessel movements. Both of these issues greatly depend on minimizing the overall distortion due to neutron & gamma heating of the Corner Cube Retroreflectors (CCRs). These are small optical mirrors embedded in five first wall locations around the vacuum vessel, corresponding to certain plasma tangency radii. During the development of the design and location of these CCRs, several iterations of neutronics analyses were performed to determine and minimize the total distortion due to nuclear heating of the CCRs. The CCR corresponding to TIP Channel 2 was chosen for analysis as a good middle-road case, being an average distance from the plasma (of the five channels) and having moderate neutron shielding from its blanket shield housing. Results show that Channel 2 meets the requirements of the TIP Diagnostic, but barely. These results suggest other CCRs might be at risk of exceeding thermal deformation due to nuclear heating.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Distributed phase sensing using two-mode squeezed states in a truncated SU(1,1) interferometer

We demonstrate distributed phase sensing with a truncated SU(1,1) interferometer through the measurement of a linear combination of two phases distributed between the two beams of a two-mode squeezed state. We theoretically analyze the sensitivity enhancement with respect to the corresponding classical strategy and experimentally demonstrate a 2 dB quantum noise reduction in the measurement of a linear combination of two phases.

Hong, Seongjin↗

A Broadband All-Fiber SU(1,1) Interferometer

We describe an SU(1,1) interferometer based on highly nonlinear optical fiber, attaining >97% peak interference visibility and >90% visibility over a 554 GHz optical band.

Lukens, Joseph↗

Continuously active interferometer stabilization and control for time-bin entanglement distribution

In this study, we describe a new method enabling continuous stabilization and fine-level phase control of time-bin entanglement interferometers. Using this technique we demonstrate entangled photon transmission through 50 km of standard single-mode fiber. This technique reuses the entangled-pair generation pump which is co-propagated with the transmitted entangled photons. In addition, the co-propagating pump adds minimal noise to the entangled photons which are characterized by measuring a two-photon interference fringe.

74 ATOMIC AND MOLECULAR PHYSICS↗

On-fiber plasmonic interferometer for multi-parameter sensing

We demonstrate a novel miniature multi-parameter sensing device based on a plasmonic interferometer fabricated on a fiber facet in the optical communication wavelength range. This device enables the coupling between surface plasmon resonance and plasmonic interference in the structure, which are the two essential mechanisms for multi-parameter sensing. We experimentally show that these two mechanisms have distinctive responses to temperature and refractive index, rendering the device the capability of simultaneous temperature and refractive index measurement on an ultra-miniature form factor. A high refractive index sensitivity of 220 nm per refractive index unit (RIU) and a high temperature sensitivity of –60 pm/ °C is achieved with our device.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Holography with a neutron interferometer

We use a Mach-Zehnder interferometer to perform neutron holography of a spiral phase plate. The object beam passes through a spiral phase plate, acquiring the phase twist characteristic of orbital angular momentum states. The reference beam passes through a fused silica prism, acquiring a linear phase gradient. The resulting hologram is a fork dislocation image, which could be used to reconstruct neutron beams with various orbital angular momenta. This work paves the way for novel applications of neutron holography, diffraction and imaging.

47 OTHER INSTRUMENTATION↗

Single-mode porous silicon waveguide interferometers with unity confinement factors for ultra-sensitive surface adlayer sensing

Guided wave-optics has emerged as a promising platform for label free biosensing. However, device sensitivity toward surface-bound small molecules is directly limited by the evanescent interaction and low confinement factor with the active sensing region. Here, we report a mesoporous silicon waveguide design and inverse fabrication technique that resolves the evanescent field interaction limitation while achieving maximal transverse confinement factors and preserving single-mode operation. The waveguide sensors are characterized in a Fabry-Perot interferometer configuration and the ultra-high sensitivity to small molecule adlayers is demonstrated. We also identify dispersion to be a promising degree of freedom for exceeding the sensitivity limits predicted by the conventional non-dispersive effective medium theory.

47 OTHER INSTRUMENTATION↗

Self referencing attosecond interferometer with zeptosecond precision

In this work we demonstrate the generation of two intense, ultrafast laser pulses that allow a controlled interferometric measurement of higher harmonic generation pulses with 12.8 attoseconds in resolution (half the atomic unit of time) and a precision as low as 680 zeptoseconds (10–21 seconds). We create two replicas of a driving femtosecond pulse which share the same optical path except at the focus where they converge to two foci. An attosecond pulse train emerges from each focus through the process of high harmonic generation. The two attosecond pulse trains from each focus interfere in the far field producing a clear interference pattern in the extreme ultraviolet region. By controlling the relative optical phase (carrier envelope phase for pulsed fields) between the two driving laser pulses we are able to actively influence the delay between the pulses and are able to perform very stable and precise pump-probe experiments. Because of the phase shaping operation occurs homogeneously across the entire spatial profile, we effectively create two indistinguishable intense laser pulses or a common path interferometer for attosecond pulses. Commonality across the two beams means that they are extremely stable to environmental and mechanical fluctuations up to a Rayleigh range from the focus. In our opinion this represents an ideal source for homodyne and heterodyne spectroscopic measurements with sub-attosecond precision.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Slow light Mach-Zehnder interferometer as label-free biosensor with scalable sensitivity

Our design, fabrication, and characterization of a label-free Mach–Zehnder interferometer (MZI) optical biosensor that incorporates a highly dispersive one-dimensional (1D) photonic crystal in one arm are presented. The sensitivity of this slow light MZI-based sensor scales with the length of the slow light photonic crystal region. The numerically simulated sensitivity of a MZI sensor with a 16 μm long slow light region is 115,000 rad/RIU-cm, which is sevenfold higher than traditional MZI biosensors with millimeter-length sensing regions. Moreover, the experimental bulk refractive index detection sensitivity of 84,000 rad/RIU-cm is realized and nucleic acid detection is also demonstrated.

47 OTHER INSTRUMENTATION↗

Atmospheric Emitted Radiance Interferometer Optimal Estimation (AERIoe) Value-Added Product Report

The Atmospheric Emitted Radiance Interferometer (AERI) Optimal Estimation (AERIoe) algorithm (Turner and Löhnert 2014, Turner and Blumberg 2019) retrieves profiles of temperature and water vapor mixing ratio, together with cloud properties for a single-layer cloud (i.e., liquid water path [LWP], effective radius), from AERI-observed infrared radiance spectrum and other measurements. The data can be used to characterize the evolution of the planetary boundary layer and boundary-layer clouds.

54 ENVIRONMENTAL SCIENCES↗

Vibration Studies for the CLARA Interferometer

The purpose of the CLARA experiment is to study the nature of undulator radiation emitted by single electrons circulating in the IOTA storage ring. The classical and quantum properties of the radiation are investigated by measuring its coherence length, intensity fluctuations and time correlations. The experiment took data in IOTA Run 4 (2022-2023). The key component of the apparatus is a Mach-Zehnder interferometer (MZI), in which the optical length of one of the arms can be precisely controlled. For some measurements, the fine regulation of the arm length must be smaller than the radiation wavelength. For this reason, the apparatus is particularly sensitive to mechanical vibrations. In this note, we model and measure the effect of vibrations on the performance of the MZI under various conditions. Several improvements of the setup were implemented to minimize systematic distortions of the observed interference patterns. In this report, we present a mathematical model of the effect of mechanical vibrations on observed detector and coincidence rates. We also describe the measurements that were made to estimate the magnitude and spectra of rate fluctuations and their sources in the CLARA MZI under various conditions. Finally, we estimate the magnitude of arm length fluctuations and we deduce the sensitivity to coincidence-rate variations in our apparatus.

43 PARTICLE ACCELERATORS↗

MODELS OF THE η CORVI DEBRIS DISK FROM THE KECK INTERFEROMETER, SPITZER, AND HERSCHEL

Debris disks are signposts of analogs to small-body populations of the solar system, often, however, with much higher masses and dust production rates. The disk associated with the nearby star η Crv is especially striking, as it shows strong mid- and far-infrared excesses despite an age of ∼1.4 Gyr. We undertake constructing a consistent model of the system that can explain a diverse collection of spatial and spectral data. We analyze Keck Interferometer Nuller measurements and revisit Spitzer and additional spectrophotometric data, as well as resolved Herschel images, to determine the dust spatial distribution in the inner exozodi and in the outer belt. We model in detail the two-component disk and the dust properties from the sub-AU scale to the outermost regions by fitting simultaneously all measurements against a large parameter space. The properties of the cold belt are consistent with a collisional cascade in a reservoir of ice-free planetesimals at 133 AU. It shows marginal evidence for asymmetries along the major axis. KIN enables us to establish that the warm dust consists of a ring that peaks between 0.2 and 0.8 AU. To reconcile this location with the ∼400 K dust temperature, very high albedo dust must be invoked, and a distribution of forsterite grains starting from micron sizes satisfies this criterion, while providing an excellent fit to the spectrum. We discuss additional constraints from the LBTI and near-infrared spectra, and we present predictions of what James Webb Space Telescope can unveil about this unusual object and whether it can detect unseen planets.

79 ASTRONOMY AND ASTROPHYSICS↗