At least 649 records · Page 36

Detailed modal testing of a solid rocket motor using a portable test system

Modern analytical techniques have expended the ability to evaluate solid rocket motors used in launch vehicles. As more detailed models of solid rocket motors were developed, testing methods were required to verify the models. Experimental modal analysis (modal testing) of space structures and launch vehicles has been a requirement for model validation for many years. However, previous testing of solid rocket motors has not typically involved dynamic modal testing of full scale motors for verification of solid propellant or system assembly properties. Innovative approaches to the testing of solid rocket motors were developed and modal testing of a full scale, two segment Titan 34D Solid Rocket Motor (SRM) was performed to validate detailed computer modeling. Special modifications were made to convert an existing facility into a temporary modal test facility which would accommodate the test article. The assembly of conventional data acquisition equipment into a multiple channel count portable system has made modal testing in the field feasible. Special purpose hydraulic exciters were configured to apply the dynamic driving forces required. All instrumentation and data collection equipment were installed at the test site for the duration of the test program and removed upon completion. Conversion of an existing test facility into a temporary modal test facility, and use of a multiple channel count portable test data acquisition system allowed all test objectives to be met and resulted in validation of the computer model in a minimum time.

Glozman, Vladimir↗

Evaluation of a Highly Anticlastic Panel with Tow Overlaps

A rectangular, variable-stiffness panel with tow overlaps was manufactured using an advanced tow placement machine. The cured panel had large anticlastic imperfections, with measured amplitudes of over two times the average panel thickness. These imperfections were not due to the overall steered-fiber layup or the tow overlaps, but instead resulted from local asymmetries in the laminate that were caused by a manufacturing oversight. In the nominal panel layup, fiber angles vary linearly from 60 degrees on the panel axial centerline to 30 degrees on the parallel edges. A geometrically nonlinear analysis was performed with a -280 degree Fahrenheit thermal load to simulate the postcure cooldown to room temperature. The predicted geometric imperfections correlated well with the measured panel shape. Unique structural test fixtures were then developed which greatly reduced these imperfections, but they also caused prestresses in the panel. Surface imperfections measured after the panel was installed in the test fixtures were used with nonlinear finite element analyses to predict these fixturing-induced prestresses. These prestresses were also included in structural analyses of panel end compression to failure, and the analytical results compared well with test data when both geometric and material nonlinearities were included.

Wu, K. Chauncey↗

Progress in Development of an Airborne Turbulence Detection System

Aircraft encounters with turbulence are the leading cause of in-flight injuries (Tyrvanas 2003) and have occasionally resulted in passenger and crew fatalities. Most of these injuries are caused by sudden and unexpected encounters with severe turbulence in and around convective activity (Kaplan et al 2005). To alleviate this problem, the Turbulence Prediction and Warning Systems (TPAWS) element of NASA s Aviation Safety program has investigated technologies to detect and warn of hazardous in-flight turbulence. This effort has required the numerical modeling of atmospheric convection: 1) for characterizing convectively induced turbulence (CIT) environments, 2) for defining turbulence hazard metrics, and 3) as a means of providing realistic three-dimensional data sets that can be used to test and evaluate turbulence detection sensors. The data sets are being made available to industry and the FAA for certification of future airborne turbulence-detection systems (ATDS) with warning capability. Early in the TPAWS project, a radar-based ATDS was installed and flight tested on NASA s research aircraft, a B-757. This ATDS utilized new algorithms and hazard metrics that were developed for use with existing airborne predictive windshear radars, thus avoiding the installation of new hardware. This system was designed to detect and warn of hazardous CIT even in regions with weak radar reflectivity (i.e. 5-15 dBz). Results from an initial flight test of the ATDS were discussed in Hamilton and Proctor (2002a; 2002b). In companion papers (Proctor et al 2002a; 2002b), a numerical simulation of the most significant encounter from that flight test was presented. Since the presentation of these papers a second flight test has been conducted providing additional cases for examination. In this paper, we will present results from NASA s flight test and a numerical model simulation of a turbulence environment encountered on 30 April 2002. Progress leading towards FAA certification of industry built ATDS will also be discussed.

Hamilton, David W.↗

Field study of group effects on the pullout capacity of “deep” helical piles in sand

This paper presents the results of a field load test program used to investigate group effects on the pullout capacity of single-helix “deep” helical piles/anchors in sand. The high tensile capacity and silent installation of helical piles has given them serious consideration as an alternative to conventional deep foundations and anchors for offshore renewable energy structures. New offshore applications may consider the use of groups of helical piles to resist structural loads. Group interaction effects are known to occur in helical piles, but there is a scarcity of field data on groups in sands under tensile loading. This study involved the installation and load testing of single-helix 152mm diameter round shaft piles and pile groups embedded in sand to depths of 12 and 18 helix diameters below the ground surface. The study was designed to explore the effects of close pile spacing, group configuration (i.e., number of piles), and soil strength (i.e., friction angle) as interpreted from cone penetration test (CPT) resistance. The results showed group efficiencies ranging from about 0.6 to 1.0 at a horizontal spacing of 2 to 3 times the helix diameter in sands with friction angles of about 39° to 44°. The data from this study may also be useful for validation of numerical models for analysis of helical pile group interactions.

Engineering↗

Estimating the Performance Loss Rate of Photovoltaic Systems Using Time Series Change Point Analysis

The accurate quantification of the performance loss rate of photovoltaic systems is critical for project economics. Following the current research activities in the photovoltaic performance and reliability field, this work presents a comparative assessment between common change point methods for performance loss rate estimation of fielded photovoltaic installations. An extensive testing campaign was thus performed to evaluate time series analysis approaches for performance loss rate evaluation of photovoltaic systems. Historical electrical data from eleven photovoltaic systems installed in Nicosia, Cyprus, and the locations’ meteorological measurements over a period of 8 years were used for this investigation. The application of change point detection algorithms on the constructed monthly photovoltaic performance ratio series revealed that the obtained trend might not always be linear. Specifically, thin film photovoltaic systems showed nonlinear behavior, while nonlinearities were also detected for some crystalline silicon photovoltaic systems. When applying several change point techniques, different numbers and locations of changes were detected, resulting in different performance loss rate values (varying by up to 0.85%/year even for the same number of change points). The results highlighted the importance of the application of nonlinear techniques and the need to extract a robust nonlinear model for detecting significant changes in time series data and estimating accurately the performance loss rate of photovoltaic installations.

photovoltaics↗

Preliminary results of the International Fusion Materials Irradiation Facility deuteron injector

In the framework of the IFMIF-EVEDA project (International Fusion Materials Irradiation Facility-Engineering Validation and Engineering Design Activities), CEA/IRFU is in charge of the design, construction, and characterization of the 140 mA continuous deuteron injector, including the source and the low energy beam line. The electron cyclotron resonance ion source which operates at 2.45 GHz is associated with a 4-electrode extraction system in order to minimize beam divergence at the source exit. Krypton gas injection is foreseen in the 2-solenoid low energy beam line. Such Kr injection will allow reaching a high level of space charge compensation in order to improve the beam matching at the radio frequency quadrupole (RFQ) entrance. The injector construction is now completed on the Saclay site and the first plasma and beam production has been produced in May 2011. This installation will be tested with proton and deuteron beams either in pulsed or continuous mode at Saclay before shipping to Japan. In this paper, after a brief description of the installation, the preliminary results obtained with hydrogen gas injection into the plasma chamber will be reported.

43 PARTICLE ACCELERATORS↗

An Assessment of Open Rotor Noise Prediction Tools

Assess the current capability for predicting the aerodynamic and acoustic performance of open rotors. The testbed is a GE blade set called F31/A31 for which significant amount of aerodynamic and acoustic data was acquired in model scale tests. F31/A31 is a vintage 1990s design with a 12-bladed front rotor and a 10-bladed aft rotor. This blade set was tested in both low-speed regime (representative of approach and takeoff conditions) and high-speed regime (representative of climb and cruise conditions). Uninstalled as well as installed configurations were tested. The focus of this interim presentation is on a subset of the low-speed tests for which the tip speed was varied, but the blade setting angles and tunnel Mach number were held fixed.

Envia, Ed↗

RHIC electron lens test bench diagnostics

An Electron Lens (E-Lens) system will be installed in RHIC to increase luminosity by counteracting the head-on beam-beam interaction. The proton beam collisions at the RHIC experimental locations will introduce a tune spread due to a difference of tune shifts between small and large amplitude particles. A low energy electron beam will be used to improve luminosity and lifetime of the colliding beams by reducing the betatron tune shift and spread. In preparation for the Electron Lens installation next year, a test bench facility will be used to gain experience with many sub-systems. This paper will discuss the diagnostics related to measuring the electron beam parameters.

43 PARTICLE ACCELERATORS↗

Feasibility of Using Conductively Cooled Magnets in Cryomidules of Superconducting Linacs

As part of a search for optimal ways to configure cryomodules of the low-beta section of a high-current, high-power superconducting linac, an option of using conductively cooled superconducting focusing lenses was evaluated. Superconducting magnet was installed inside existing test cryostat, which was modified by adding current feed-throughs and two conductively cooled current leads. Each lead was equipped with heat sinks at the temperatures of liquid nitrogen and liquid helium. The magnet was mounted inside the cryostat on an individual heat sink plate, and thermometers were installed on the leads, heat sinks, and on the magnet. In this report we provide some details of the test setup and analyse results of the temperature measurements.

43 PARTICLE ACCELERATORS↗

Design of a D-Strut and its application results in the JPL, MIT, and LaRC test beds

High damping at very low magnitudes of vibration is provided by an 'Arched Flexure' D-Strut. Five of these devices have been incorporated in JPL's CSI truss structure, and five more in MIT's interferometer test bed. Two were also temporarily installed in the LaRC CSI test structure. Damping factors in the 50 percent category are being provided at vibration motions as small as 50 nm. The 'Arched Flexure' used in the D-Strut maximizes the volumetric stiffness parameter relative to its axial stiffness. In turn, this enables high damping factors, even in a very rigid truss structure. This paper includes a presentation and discussion of both element and system test data taken at JPL, LaRC, and MIT. Also provided is a detailed description of the D-Strut, the dynamic model, and several graphs showing design parameter variations that will make it possible to evaluate the D-Strut for other applications.

Davis, L. P.↗

Challenges and Opportunities for Basic Efficiency Measures in Low-Income Homes: A Southeast Alaska Case Study

Juneau, Alaska is the state's capital city and has a renewable energy goal to reach 80% renewable energy for the space heating and transportation sectors by 2045. In practical terms, this indicates a need to electrify both sectors, to take advantage of the inexpensive hydropower available from the local electric utility, Alaska Energy Light & Power. In an effort to complement and enable electrification, researchers examined the feasibility to deploy storm windows via a case study of installing storm windows in two local low-income homes. Newer models of storm windows provide an extra layer of insulation over existing windows, while preserving operability and views. They can also improve comfort and reduce noise. Researchers worked with the regional housing authority and a local builder to install the storm windows and replace inoperable windows in the two houses in 2021, in addition to conducting pre- and post-installation air leakage tests, energy monitoring, and occupant interviews. The team encountered several challenges, including a lack of egress windows, energy data from a wide variety of heating systems, extremely leaky homes, and installation issues such as windows that were not square. These results point to several barriers to widespread deployment of storm windows in the area, but also open the door to opportunities to design deployment programs that improve safety as well as efficiency.

cold climate↗

Solar energy system performance evaluation: Seasonal report for fern, Tunkhannock, Pennsylvania

The operational and thermal performance of a variety of solar systems installed in operational test sites are described. The analysis is based on instrumented system data monitored and collected for at least one full season of operation. The long-term field performance of the installed system is reported, and technical contributions to the definition of techniques and requirements for solar energy system design are made. The solar energy system was designed to supply space heating and domestic hot water for single-family residences. The system consists of air flat plate collectors, storage tank, pumps, heat exchangers, associated plumbing, and controls.

Source record↗

Solar energy system performance evaluation: Seasonal report for SEMCO, Loxahatchee, Florida

The operational and thermal performance of a variety of solar systems installed in operational test sites are described. The analysis used is based on instrumented system data monitored and collected for at least one full season of operation. The long-term field performance of the installed system and the technical contributions to the definition of techniques and requirements solar energy system design are analyzed. The solar energy system was designed to supply domestic hot water for a family of four, single-family residences. It consists of two liquid flat plate collectors, single tank, controls, and transport lines.

Source record↗

Development of a test rig for a helium twin-screw compressor

A large helium cryogenic system is being developed for use in great science projects, such as the International Thermonuclear Experimental Reactor (ITER), Large Helical Device (LHD), and the Experimental Advanced Superconducting Tokamak (EAST). In this cryogenic system, a twin-screw compressor is a key component. Therefore, it is necessary to obtain the compressor performance. To obtain the performance characteristics, a test rig for the compressor has been built. All the important performance parameters, including adiabatic efficiency, volumetric efficiency, oil injection characteristic, and noise characteristic can be acquired with the rig when sensors are installed in the test system. With the test performance, the helium twin-screw compressor can be evaluated. Using these results, the design of the compressor can be improved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sensitivity analysis of an automated fault detection algorithm for residential air-conditioning systems

The state of the art of fault detection and diagnosis (FDD) for residential air-conditioning systems is expensive and not yet amenable to widespread implementation. FDD for homes can significantly reduce utility costs, and increase the lifespan of the equipment. The cost barriers currently, however, make FDD for homes economically unviable for large scale implementation. In prior work, we offered a solution to reduce FDD costs by proposing an automated fault detection algorithm to serve as a screening step before more expensive FDD tests can be conducted. The algorithm uses only the home thermostat and local weather information to identify thermodynamic parameters and detect high-impact air-conditioning faults, including those that occur during equipment installation. We had tested the algorithm on a single EnergyPlus™ model of a home in Orlando, Florida. The thermodynamic parameter identification process is highly nonconvex involving several local optimal solutions. In this paper we propose a novel method to select the best model for fault detection from among the list of local optimal solutions to make the algorithm more robust to homes of different construction, without which the fault detection process would be infeasible. Another unique contribution of the paper is implementing the solution on real-world data. We also bring the algorithm closer to market by testing it on real-world data. We implement the algorithm on data obtained from experiments conducted by the Florida Solar Energy Center (FSEC) on a laboratory home equipped with a heat pump where faults were intentionally added for a period of seven months. The algorithm successfully detected an undercharge fault with 70.6% accuracy, concurrent duct leakage and undercharge faults with 85.2% accuracy, and duct leakage faults with 69.1% accuracy. A sensitivity analysis is also performed on EnergyPlus models of nine types of homes that vary in construction to demonstrate the robustness of the algorithm. Finally, the algorithm achieves an average accuracy of 71% for no-fault condition, 77% for 40% undercharge fault, and 76% for duct-leak fault.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Endurance testing of first generation /Block I/ commercial solar cell modules

NASA-LeRC has conducted outdoor endurance tests on modules commercially produced as part of the 46-kW purchase of first generation (Block I) modules by the JPL Low Cost Silicon Solar Array Project. Block I modules from four manufacturers were installed at commercial testing sites in Florida, Puerto Rico, and Arizona and at noncommercial sites in Cleveland, Ohio. The conditions endured by these modules included hot and dry, hot and humid, tropical rain forest, sea-air, urban industrial and urban clean; exposures were for periods up to one year. Test results are presented and discussed.

Anagnostou, E.↗

TAXI Interface Demultiplexes Proprietarily Formatted Data

The 'TAXI Direct-to-Disk' interface is a special purpose interface unit for demultiplexing of data from a Racal Storeplex (or equivalent) multichannel recorder onto one or more hard disks that reside in, and/or are controlled by, a personal computer (PC). The acronym 'TAXI' signifies transparent asynchronous transceiver interface. The TAXI interface was developed for original use in capturing data from instrumentation on a test stand in a NASA rocket testing facility. The installation of the TAXI interface, in conjunction with other modifications, causes the transfer of data to take place in real time, so that the data are immediately available for review during or after the test.

Newnan, Bruce G.↗

Integrated Hydrogen Sensor and Separator for Parabolic Trough Expansion Tanks

The National Renewable Energy Laboratory (NREL) and Acciona Energy USA Global are developing and implementing a process that addresses the issue of hydrogen buildup in parabolic trough power plants. Our method selectively removes hydrogen from the expansion tanks of the power plant to control hydrogen levels in the circulating heat-transfer fluid (HTF). As part of this effort, we developed a sensor that measures hydrogen partial pressure in the expansion-tank headspace gas. During previous work, we demonstrated that our sensor measures hydrogen levels over a wide range of partial pressure from 1.33 mbar down to 0.003 mbar. In this paper, we report our most recent work, in which we conceived and developed an integrated process module that performs both hydrogen sensing and separating functions. The sensor/separator measures hydrogen partial pressure in the headspace gas in the same way as our original sensor design. Additionally, the integrated module separates hydrogen from the headspace gas to reduce hydrogen to the level needed to maintain the performance of receivers in the collector field. Sensor data from the integrated module also provide an estimate of the rate at which hydrogen is being extracted from the headspace gas. We designed and fabricated a laboratory-scale integrated module and determined its performance in our laboratory at NREL. Testing showed that the module performed as expected in both sensing and separating modes. The accuracy of the sensing function was +/-10%. The hydrogen extraction rate for the separating mode was consistent with our modeling predictions. The primary benefit of this module is its simple design, both in terms of function and incorporation into the HTF subsystem of the power plant. The integrated module can be installed close to the HTF expansion tanks, where it draws headspace gas from the tanks, removes hydrogen, and returns the treated gas back to the tanks. We are currently installing a test-scale process at the Nevada Solar One (NSO) power plant to demonstrate this process and determine its operational performance. Results from the test-scale process will be used to specify and design the full-scale process that will be installed at NSO.