At least 649 records · Page 36

Tracking the PACE of household energy usage: Energy usage impacts of projects financed through Property Assessed Clean Energy programs in California

This report examines the household-level energy impacts of residential property assessed clean energy (R-PACE) projects using normalized metered energy consumption methods. Our analysis covers projects that occurred through an R-PACE program between 2009 and 2017 and includes more than 25,000 electricity meters and 15,000 gas meters. We employ a comparison group, drawn from other R-PACE households with similar locational and usage characteristics whose projects were implemented at different times, to control for some non-project and non-weather factors that may impact energy use. We find that projects consisting of energy efficiency technologies save, on average, about 3% of household electricity usage and 3.5% of household gas usage. R-PACE financing, however, can be used to install central heating or air conditioning equipment for the first time. These projects would be expected to increase energy consumption. Since our data do not directly indicate which projects are new installations, we develop a simple algorithm for identifying them. Removing these inferred installation projects yields average savings of about 5% for electricity and 6% for gas for those households that remain in the sample. Given the mild California climate and the results of another study of similar California projects using similar methods, these results are in line with expectations. Solar PV projects yield large reductions in grid electricity use, averaging 69% of household consumption. We estimate that, collectively, all R-PACE projects installed in California through 2019 would generate annual reductions in grid-tied electricity consumption of 506 GWh (mostly due to solar PV) and gas consumption reductions of 2 million therms in a normal weather year. These impacts are equivalent to the electricity consumption of about 74,000 California households (including both efficiency and PV generation) and the gas consumption of about 4700 California households.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Exploring Impacts to COVID-19 Herd Immunity Thresholds Under Demographic Heterogeneity that Lowers Vaccine Effectiveness

The COVID-19 pandemic has caused severe health, economic, and societal impacts across the globe. Although highly efficacious vaccines were developed at an unprecedented rate, the heterogeneity in vaccinated populations has reduced the ability to achieve herd immunity. Specifically, as of Spring 2022, the 0–4 year-old population is still unable to be vaccinated and vaccination rates across 5-11 year olds are low. Additionally, vaccine hesitancy for older populations has further stalled efforts to reach herd immunity thresholds. This heterogeneous vaccine landscape increases the challenge of anticipating disease spread in a population. We developed an age-structured Susceptible-InfectiousRecovered-type mathematical model to investigate the impacts of unvaccinated subpopulations on herd immunity. The model considers two types of undervaccination - age-related and behaviorrelated - by incorporating four age groups based on available FDA-approved vaccines. The model accounts for two different types of vaccines, mRNA (e.g., Pfizer, Moderna) and vector (e.g., Johnson and Johnson), as well as their effectiveness. Our goal is to analyze different scenarios to quantify which subpopulations and vaccine characteristics (e.g., rate or efficacy) most impact infection levels in the United States, using the state of New Mexico as an example.

59 BASIC BIOLOGICAL SCIENCES↗

Sensor Impact Evaluation at Different Sensor Locations in a Multi-zone Office Building

FY 2022 Q1 deliverables include the development of an emulator that can evaluate the sensor impacts at different sensor locations (i.e., thermostat locations) in a multizone office building. This report presents the detailed procedure of developing the emulator and using the emulator for preliminary sensor impact analysis. In designing new multizone buildings or retrofitting existing buildings, the room thermostat locations or subzoning design has been often determined by best practices without considering the effects of this design in terms of energy or thermal comfort. In subzoning design, the total number of thermostats is usually smaller than the total number of rooms. As a result, one thermostat in one room often controls the indoor temperature of several other adjacent rooms. For example, five zones might share one thermostat located in one of the zones. Because the demands for thermal load in different zones could be different for the multizone buildings, this subzoning design can compromise control performance and waste building energy consumption. Furthermore, for multizone buildings, subzoning could introduce thermal discomfort for zones. This issue has not be thoroughly investigated in simulation/field studies, and the US Department of Energy’s Oak Ridge National Laboratory explored the impacts of subzoning design through modeling and experimental study.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ASTRO: Facilitating Advancements in Low-Impact Solar Research, Deployment, and Dissemination

The U.S. Department of Energy's (DOE) InSPIRE project evaluates opportunities for cost reductions and assesses the environmental compatibility of solar energy technologies through low environmental impact designs and approaches. To achieve the project's aim, DOE brings together researchers from the National Renewable Energy Laboratory, Argonne National Laboratory, universities, local governments, environmental groups, and solar industry partners to conduct field-based research complemented by foundational analytical studies. The Agriculture and Solar Together: Research Opportunities (ASTRO) advisory group members come from across the United States and represent leading solar industry partners, state agencies, vegetation management companies, and other organizations focused on research, food and agriculture, and the environment. The ASTRO group of engaged advisors is a complementary combination of organizations creating positive feedback loops that spark and solidify new connections, accelerate information dissemination, and magnify the impact of the InSPIRE project and associated low-impact solar research initiatives.

14 SOLAR ENERGY↗

An Assessment of Current Understanding of the Greenhouse Gas Impacts from H 2 Emissions

With the anticipated growth in hydrogen generation and use as part of a broad shift in energy use away from fossil fuels, concerns have been raised regarding the impact of increased H 2 emissions on global warming. Atmospheric scientists have long recognized that H 2 emissions into the atmosphere do have an indirect impact on global warming, largely because a portion of emitted H 2 is consumed by the hydroxyl radical (OH), which is the primary reactant that removes the potent greenhouse gas methane from the atmosphere. Therefore, increases in H 2 emissions will result in decreases in the average OH concentrations in the atmosphere and an increase in the atmospheric lifetime of methane. Various assessments of the impact of H 2 emissions on global warming have been performed over the past couple of decades. These assessments have yielded significant variability and recognized uncertainty in the magnitude of the warming effect of a given quantity of emitted H 2 , and an even greater uncertainty in the magnitude of H 2 leakage and releases that can be anticipated with an expanded H 2 infrastructure. Consequently, definitive estimates of the magnitude of the warming effect of additional emitted H 2 are lacking. However, given the current understanding of the warming potential of emitted H 2 and given reasonable expectations of the emission rate of an expanded H 2 infrastructure, it is anticipated that warming effects from emitted H 2 will offset no more than 5% of the reduction in warming associated with avoided CO 2 emissions from using clean H 2 . Further, it is highly unlikely that the warming effects from emitted H 2 will offset more than 10% of the benefit from avoided CO 2 emissions, at least as considered over a typical 100-year accounting period. Because of the short atmospheric lifetimes of H 2 and methane, however, the warming effect of emitted H 2 is enhanced over the first few years following increases in H 2 emission.

54 ENVIRONMENTAL SCIENCES↗

Impact of Transport Electrification Demand and Charging Schedules on Electricity Markets and Nuclear Generators

As the U.S. pursues deep decarbonization targets, electric vehicles (EVs) are likely to become a major driver of demand growth and a major determinant of daily demand patterns. This study analyzes a possible future ERCOT-like electricity grid, and examines the impact of different types of EV charging schedules on grid and market outcomes. This analysis demonstrates the significant impact of EV charging patterns on capacity expansion simulations. Even without EVs, the overall daily demand profile in a market can have significant impacts on prices and grid stability in that system, especially if non-dispatchable renewable generators (e.g. wind and solar) make up a significant fraction of the generation mix. EV demand will not necessarily follow this preexisting demand profile, so its daily trends may significantly change what generation portfolio would optimally serve the system. Furthermore, the effects of EV demand can alter the profitability of different types of units, by altering the frequency of market events like extreme-demand hours or zero-price hours. These effects are explored in this study. The EV demand levels were derived from MARKAL simulations of the West-South-Central North American Electric Reliability Corporation (NERC) region for the year 2050, using a carbon tax of $100/ton. The baseline MARKAL simulation forecasted that 23% of the region’s annual electricity demand in 2050 would be attributable to EVs, and broke out demand projections for EV and non-EV end-use in that year. To model lower EV penetration into the system, an additional case was explored which assumed that EVs only achieved 75% of the demand level projected by MARKAL.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Preliminary Sensitivity Analysis for Sensors Impacts on Building Control Performance

This report describes the preliminary sensitivity analysis for sensor impacts on building control performance through the US Department of Energy’s Oak Ridge National Laboratory’s Flexible Research Platform (FRP-2) building. The rooftop unit system provides cooling and heating to the building. The main heating coil is a gas heating coil. Each zone is served by a variable air volume box with an electricity reheat coil. The rooftop unit and variable air volume box controls adopted the practical control sequences from ASHRAE Guideline 36-2018: High-Performance Sequences of Operation. For sensors, the incipient (time-changing) sensor errors, including bias sensor error and precision sensor error, are the inputs of interest. The outputs are energy consumption and thermal comfort (e.g., the predicted percentage of dissatisfied occupants). The large-scale simulation (3,600 cases) was conducted on a cloud platform by integrating sensor errors and ASHRAE Guideline 36 control sequences into an emulator based on the EnergyPlus simulation program with Python energy management system feature. The surrogate models were developed based on cloud simulation results. The uncertainty analysis showed that the sensor errors substantially affect building energy consumption and thermal comfort. The sensitivity analysis shows a ranking of sensor error impacts for each interested output item (e.g., cooling energy, reheat coil heating energy, predicted percentage of dissatisfied occupants). In FY 2022, sensor locations, types, and costs will be evaluated. The field test in Oak Ridge National Laboratory’s Flexible Research Platform building regarding sensor impacts will also be performed. Finally, a comparative analysis will be conducted based on the field test results and emulator results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluating the Impacts of the Bipartisan Budget Act of 2018 45Q Tax Credit on CCS Network Costs

This study evaluates the impact of the Bipartisan Budget Act of 2018 (BBA)-amended 45Q tax credit on integrated carbon capture and storage (CCS) networks for source types and geologic storage reservoirs common to the north-central U.S. The integrated CCS networks evaluated were chosen to closely replicate those in the forthcoming National Energy Technology Laboratory (NETL) central U.S. CCS cost options study’s Northwest CCS Network Regional Impact Area (Northwest Impact Area).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Impact of Non-Steady State Operation on Cooling Water Consumption at Coal- and Natural Gas-Fired Power Plants

Increased renewable energy penetration in the electricity grid in coming decades will result in more frequent cycling at thermal power plants. Simultaneously, thermal power plants may face water scarcity with declining availability of cooling water. Therefore, to enhance thermal power plants’ resiliency to water shortages it is important to understand how non-steady conditions due to cycling will impact cooling water consumption and withdrawal intensity. Non-steady operation at power plants has been previously shown to decrease power plant thermal efficiency. Energy balance models have also demonstrated that a decrease in thermal efficiency is expected to increase cooling water consumption intensity. Furthermore, past work has used operating hours data to show idling and cycling gaps where cooling systems operate more than corresponding generators. As a result, an increase in cycling behavior may impact cooling water consumption and withdrawal intensity. This study uses data from the Energy Information Administration (EIA) and Environmental Protection Agency (EPA) to quantify the impact of cycling cooling water consumption intensity for recirculating cooling systems and withdrawal intensity for once-through cooling systems using energy balance and statistical approaches. In a novel application of a fixed effects model to study the effect of temperature on cooling water consumption and withdrawal intensity, this study finds temperature was consistently expected to increase consumption intensity and withdrawal intensity. Non-steady state conditions do not increase cooling water consumption intensity with statistical significance across unit types. However, additional validation of cooling water data is required to confirm these observed trends due to the sensitivity of these findings to model form and concerns with data quality of the dependent variables, cooling water consumption and withdrawal.

20 FOSSIL-FUELED POWER PLANTS↗

An Assessment of Potential Dose Impacts from External Contamination on Naval Reactors Facility Waste Canisters (Special Analysis)

This Special Analysis (SA) was performed to address a request by Naval Reactors Facility (NRF) Waste Programs for a permanent exception to limits of removable surface contamination on the exterior of waste canisters shipped to the Remote-Handled Low-Level Waste (RHLLW) Disposal Facility as specified in the waste acceptance criteria (WAC) (PLN-5446). The purpose of this SA is to determine if the NRF-requested levels for removable surface contamination on the exterior of all NRF waste canisters is within the bounds of the current performance assessment (PA). This was done by calculating the groundwater all-pathways dose contribution from surface contamination on the exterior of NRF canisters for the following cases: (1) the exteriors of all NRF waste canisters are contaminated to the 10 CFR 835 Appendix D allowable limits in the current WAC, and (2) the exteriors of all NRF waste canisters are contaminated to the limits requested by NRF Waste Programs. Dose impacts for each case were compared to each other and to the all pathways dose for the PA base case. Dose impacts were also compared to the all pathways dose limit specified in DOE O 435.1. A simple assessment of the potential impacts of the increase in surface contamination using the NRF-requested limits on the biotic, air, and inadvertent intruder pathways was also performed. Based on the results of this SA, the increase in canister exterior contamination limits requested by NRF are well within the bounds of the current PA and will not result in a violation of performance objectives. The results also show the increased limits do not reflect or necessitate a fundamental change to the PA conceptual model, nor a change to the way exterior contamination is not included in PA dose calculations. Therefore, it is recommended the NRF request for an exception to the current limits for external surface contamination be accepted and the revised limits for NRF-generated waste canisters be added to the WAC. The monitoring plan will also be revised to identify external canister contamination as a potential mobile source term that may be detected by monitoring earlier than potential releases from waste. The PA, composite analysis (CA), closure plan, and PA/CA maintenance plan do not require revision. Recommendations are also included for inclusion of NRF procedures used to limit water pool radionuclide variability (and thus canister surface contamination variability) to the waste generator certification process.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Quantifying the Financial Impacts of Electric Vehicles on Utility Ratepayers and Shareholders [Slides]

Widespread electric vehicle (EV) adoption is critical for meeting economy-wide decarbonization goals and, as a result, states are considering enabling policies and rate designs to accelerate EV deployment. EVs can provide possible financial upside to electric utilities and ratepayers in several ways. For example, from the utility perspective, EVs could drive increased electricity sales and new earnings opportunities through increased capital investments. From the ratepayer perspective, increased electric loads from EVs could reduce average all-in retail rates. The degree to which there are net benefits or costs to shareholders and/or ratepayers depends on how EVs are integrated and managed through enabling grid investments and charging strategies. Using Berkeley Lab’s Financial Impacts of Distributed Energy Resources (FINDER) model that mimics the electric utility investment planning and ratemaking processes, we estimate the utility earnings and customer rate impacts of EVs using a bookend approach of “managed” (i.e., best case) and “mismanaged” (i.e., worst case) charging strategies for a generic summer-peaking, investor-owned, and vertically integrated utility. The analysis also examines the sensitivity of results to different assumptions of EV deployment characteristics, EV impacts on retail electricity sales, incremental distribution system costs, EV charging location, and utility EV enablement costs (i.e., utility costs to invest in EV charging, controls, and communication to deliver and administer EV programs). The results are intended to inform EV policies and deployment strategies that maximize utility system benefits and minimize ratepayer costs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The Los Angeles 100% Renewable Energy Study (LA100): Chapter 11. Economic Impacts and Jobs

The City of Los Angeles has set ambitious goals to transform its electricity supply, aiming to achieve a 100% renewable energy power system by 2045, along with aggressive electrification targets for buildings and vehicles. To reach these goals, and assess the implications for jobs, electricity rates, the environment, and environmental justice, the Los Angeles City Council passed a series of motions directing the Los Angeles Department of Water and Power (LADWP) to determine the technical feasibility and investment pathways of a 100% renewable energy portfolio standard. The Los Angeles 100% Renewable Energy Study (LA100) is a first-of-its-kind objective, rigorous, and science-based power systems analysis to determine what investments could be made to achieve these goals. The LA100 final report is presented as a collection of 12 chapters and an executive summary, each of which is available as an individual download. This chapter reviews economic impacts, including local net economic impacts and gross workforce impacts.

100% Renewable↗

Impacts of LEU+ and HBU Fuel on Decay Heat and Radiation Source Term

Using low-enriched uranium with 235 U enrichment slightly greater than 5.0 wt % (LEU+) fuel is desirable for light water reactors (LWR) because it can enable longer cycles and/or smaller fresh fuel batches. This report analyzes the impact of LEU+ on back-end considerations, such as its impact on the spent fuel pool, and on the thermal and shielding performance of dry storage systems. For both pressurized water reactor (PWR) and boiling water reactor LEU+ fuel, this report concludes that additional cooling time or regionalized loading plans are required to maintain the same level of thermal and shielding performance of dry storage systems loaded with LEU fuel. For PWR fuel, this report concludes that the impact of LEU+ fuel on the time-to-boil of a spent fuel pool (SFP) is minimal and does not require considerable changes in SFP management.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Final Technical Report: Impact of Wildfires on Solar Generation, Reserves, and Energy Prices

This study quantifies the potential impacts of wildfires on the California grid, specifically the impacts under three different wildfire scenarios: a "no wildfire" scenario and two wildfire-specific scenarios, "2020 wildfire" and "enhanced wildfire" (with both wildfire scenarios assuming spatial distribution of the wildfire location the same as the 2020 fires). The study combines each scenario with two solar energy infrastructures: one corresponding to the current solar installation and the other to future (midcentury) solar installation. The analysis is conducted using state-of-the-science modeling tools: primarily WRF-Chem for atmospheric modeling with chemistry to account for impacts of wildfires on solar radiation and PLEXOS for electricity market simulations. The analysis suggests that wildfires can significantly attenuate solar radiation at both short downwind distances as well as far from the emissions sources. Although the study is limited in scope, and the analysis studies only a few of the many factors that can affect photovoltaic generation and electricity markets, it indicates that wildfire smoke is an important factor that needs to be carefully considered and analyzed in planning the future grid.

electricity market↗

Simulations of Hypervelocity Impact Plasmas

The space environment is fraught with complex plasmas spanning a wide range of densities and temperatures. Much of space plasma research has focused on large-scale changes in the ambient plasma and fields from the Sun to the Earth’s atmosphere, driven primarily by the solar wind. Yet one particular type of space plasma, which forms from a hypervelocity impact (HVI), remains poorly understood. Hypervelocity impactors include both meteoroids and space debris. Meteoroids are naturally occurring objects in space that travel between 11 and 72.8 km/s and originate primarily from comets and asteroids. In contrast, space debris are human-made objects with speeds typically < 11 km/s. Hypervelocity impactors routinely hit spacecraft, yet the physics behind the formation of the plasma and the dynamics of its expansion remain largely unknown. The complexity of this phenomenon necessitates a research approach that includes both experimental studies and numerical simulation in order to understand the underlying physical processes that occur upon formation and expansion of the impact plasma. Our research has focused on providing a comprehensive understanding of plasma generated by hypervelocity impacts by meteoroids and space debris on spacecraft in order to characterize the behavior of the expanding plasma and its interactions with the ambient environment. Previously. we conducted experimental campaigns at a dust accelerator facility that can accelerate particles up to 60 km/s, which is representative of meteoroid speeds, and at a light gas gun facility that can accelerate larger projectiles up to 7 km/s, which is representative of orbital debris. The experiments included plasma, optical and radio frequency (RF) sensors in order to understand the dynamics and associated RF emission resulting from hypervelocity plasmas. For this research, we developed and applied machine learning algorithms to identify which type of impactor would produce RF and physics-based models to determine the source of the RF. This was a one-year research program that resulted in 2 refereed journal publications (uploaded separately).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

How a Large-Scale Deployment of Grid-Forming Inverters May Impact Inter-Area Oscillation Modes: An Investigation in the US Western Interconnection

This report describes work performed to evaluate the impact of high grid-forming (GFM) inverter penetration on the inter-area oscillation mode characteristics of the Western Interconnection. Using simulations, this work analyzes how: a) replacing fossil-fuel-based synchronous generators by GFM inverters will impact properties of the North-South mode, and b) replacing the Colstrip power plant by grid-following (GFL) and GFM inverters will change the characteristics of the Montana mode. Results obtained indicate that high penetration of GFM inverters will significantly alter inter-area oscillation characteristics in interconnections. Low frequency oscillations in the 0.11 Hz range will be predominantly driven by remaining synchronous machines, and hence their relative distribution in the interconnection will impact mode characteristics and observability.

20 FOSSIL-FUELED POWER PLANTS↗

Microbial metabolic dependency and its impacts on the soil carbon cycle (Final Technical Report, DE-SC0016364)

The terrestrial biosphere contains a large fraction of global carbon (C) and nearly 70% of the organic C in terrestrial systems is found in soils. Global changes in atmospheric CO 2 , temperature, precipitation, and ecosystem N inputs, will impact primary production and carbon inputs to soils, but it remains difficult to predict soil responses to these environmental conditions. Our ability to predict C-cycle responses to global change remains limited by unexplained variability within the terrestrial C-cycle. Our difficulty in predicting responses of the soil C-cycle to environmental change suggests a need for a greater understanding of the biotic mechanisms that govern soil C-transformations. Changes in microbial community structure and function have been proposed to impact soil processes, but mechanistic connections between microbial activity and C-cycle transformations remain poorly described. We assembled an interdisciplinary team to conduct cross-scale examination of microbial contributions to C-cycle dynamics and C-fate in soils. We investigated microbial contributions to soil C-transformations using a suite of complementary isotopic techniques including DNA-Stable Isotope Probing (DNA-SIP), metagenomic-SIP, metabolomic-SIP, proteomic-SIP, and microspatial analysis of soil organic C. These techniques were deployed in experiments that tested fundamental assumptions that underlie terrestrial C-cycle models. We characterized the functional characteristics of soil microorganisms responsible for major C-transformations in soil, evaluated the metabolic and ecological interactions that underlie soil C-cycle dynamics, and evaluated the degree to which these interactions impact rates of C mineralization and stabilization in soils.

54 ENVIRONMENTAL SCIENCES↗

Distribution Grid Impacts of Community Solar [Slides]

Community solar (CS) projects often face uncertain interconnection costs and fees associated with distribution grid infrastructure upgrades required to connect the project. These costs can determine the economic viability of a CS project, but they are difficult to assess. Cost uncertainty can discourage new projects and prevent communities from accessing the benefits of community solar projects. At the same time, CS deployment strategies hold potential to defer or avoid some distribution costs due to new loads. To mitigate CS interconnection costs, it is important to find least-cost combinations of distribution system infrastructure solutions (transformer upgrades, reconductoring, voltage regulators, storage), and to understand how location of CS projects within a feeder impact distribution grid upgrade costs. This study aims to quantify CS impacts on the distribution grid and provide policy and regulatory insights and CS deployment strategies to address them. It is the first analysis that has systematically studied the technical impacts of community solar projects on a wide range of distribution feeders using state-of-the-art optimization and power flow tools. The analysis employs Berkeley Lab’s novel Least-cost Optimal Distribution Grid Expansion (LODGE) model, a deterministic version of the REPAIR model, that optimally upgrades hundreds or even thousands of distribution circuits or feeders. This is the first application of the LODGE model. LODGE finds the least-cost portfolio of traditional distribution system upgrades to integrate CS in combination with alternative solutions, such as utility-owned storage and downsizing CS capacity. Working with a set of least-cost solutions per feeder allows us to benchmark, compare and find techno-economic trends in CS interconnection.

14 SOLAR ENERGY↗