Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “humidity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Group 3: Humidity, Temperature and Voltage (Presentation)

This is a summary of the work of Group 3 of the International PV QA Task Force. Group 3 is chartered to develop accelerated stress tests that can be used as comparative predictors of module lifetime versus stresses associated with humidity, temperature and voltage.

14 SOLAR ENERGY↗

IEC Quality Assurance Task Group 5: UV, Temperature, and Humidity (Presentation)

Taskgroup 5 (TG5) is concerned with a comparative aging standard incorporating factors including ultraviolet radiation, temperature, and humidity. Separate experiments are being conducted in support of a test standard via the regional sub-groups in Asia, Europe, and the United States. The authors will describe the objectives and timeline for TG5 as well as providing an update on the experiments in progress.

14 SOLAR ENERGY↗

Challenges to detection: Humidity as a spur to chemical agent change

Detecting chemical agents in outdoor environments such as a battlefield is made challenging by not only the spurious signatures from background chemicals and surfaces (e.g. asphalt, dirt, concrete), but also by the chemical transformation of the actual agents. The change of CW agents to other species can be catalyzed by other chemicals present in the scene, by different substrates, as well as by local weather conditions. Some of the final environmental transformation products are known (e.g. for the G agents methylphosphonic acid), but many of the intermediate chemical states are not, nor are the rates of transformation to the other intermediates or the end products. In this study we have made preliminary optical investigations into the degradation products of a G-agent intermediate, namely methylphosphonic anhydride and its rate of conversion to the more stable methylphosphonic acid. Using infrared and Raman spectroscopies, we have found that the relative humidity (RH) greatly affects the rate of change and we report first results from these studies.

: chemical warfare agent detection, Methylphosphon↗

, Experimental Investigation of Electrically Charged Water Droplets Two-Phase Cross-Flow Interactions with Humid

Electrically charged water droplets can capture water vapor molecules in surrounding moist air and promote vapor condensation. This concept unfolds an alternative to mechanical cooling-based air dehumidification systems that separate sensible and latent cooling loads in HVAC applications. The effect of dielectrophoresis, electro-hydrodynamic, and micro-diffusive flows due to highly electrically charged water droplets traveling through moist air were investigated as new methods to reduce the air’s water vapor content. This paper presents new experimental data on humidification and power consumption for a system consisting of highly energized electrosprays in combination with mist eliminators. Electrosprays produced highly charged water spray cones crossing the air perpendicularly and upwardly. The moist air stream was circulated in a horizontal duct at 22C, 80% relative humidity, and 0.24 ms-1 airspeed. Mist eliminators made of stainless wire clothes of 36 and 25 μm pore diameter were used to screen the droplets growing during their flight trajectory. The mist eliminators blocked some of the largest diameter droplets. Still, they could not prevent re-evaporation of the droplets into the bulk air from the droplets deposited on their wire clothes. The equilibrium between the dielectrophoresis condensation from the electrosprays and the droplets’ re-evaporation phenomena resulted in reduced humidification when compared to conventional-type spray evaporative cooling systems. However, to dehumidify the air, the droplets injected by the electrosprays must be separated entirely and promptly removed from the bulk airflow at the end of their flight trajectory.

Electrostatic droplets, Electrospray, humidificati↗

Variable Refrigerant Flow Performance: Humidity and Efficiency in Multifamily Buildings in New York, NY

Variable refrigerant flow (VRF) systems have become common in large multifamily buildings. The upfront cost is appealing to developers, as a single system can provide all heating and cooling. VRF systems also use no on-site fossil fuels which can help avoid greenhouse gas emissions. However, there have been very few data on how VRF systems actually perform in buildings. Researchers monitored three new, multifamily buildings with a focus on VRF system sizing, humidity control, and energy efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling the Size Distribution and Chemical Composition of Secondary Organic Aerosols during the Reactive Uptake of Isoprene-Derived Epoxydiols under Low-Humidity Condition

Reactive uptake of isoprene epoxydiols (IEPOX), which are isoprene oxidation products, onto acidic sulfate aerosols is recognized to be an important mechanism for the formation of isoprene-derived secondary organic aerosol (SOA). While a mechanistic understanding of IEPOX-SOA formation exists, several processes affecting their formation remain uncertain. Evaluating mechanistic IEPOX-SOA models with controlled laboratory experiments under longer atmospherically relevant timescales is critical. Here, we implement our latest understanding of IEPOX-SOA formation within a box model to simulate the measured reactive uptake of IEPOX on polydisperse ammonium bisulfate seed aerosols within an environmental Teflon chamber. The model is evaluated with single-particle measurements of size distribution, volume, density, and composition of aerosols due to IEPOX-SOA formation at timescales of hours. Additionally, we find that the model can simulate the growth of particles due to IEPOX multiphase chemistry, as reflected in increases of the mean particle size and volume concentrations, and a shift of number size distribution to larger sizes. The model also predicts the observed evolution of particle number mean diameter and total volume concentrations at the end of the experiment. We show that in addition to self-limiting effects of IEPOX-SOA coatings, accounting for the molar balance between inorganic and organic sulfate and mass accommodation coefficient of IEPOX are important parameters governing modeling of IEPOX-SOA formation. Thus, models which do not account for the molar sulfate balance and/or diffusion limitations within IEPOX-SOA coatings are likely to predict too high IEPOX-SOA formation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Influence of Ultraviolet Exposure and Humidity on the Photoluminescence Spectra of Zinc Oxide

The structure and electrical and luminescent properties of arrays of zinc-oxide nanorods grown by the hydrothermal method are studied. It was found that the exposure of samples to ultraviolet light or the presence of water vapor in a gaseous atmosphere significantly change the photoluminescence spectra. The exposure of samples leads to a substantial increase in intrinsic photoluminescence and a decrease in impurity photoluminescence. The presence of water vapor leads to the opposite effect. It is shown that the observed effects are caused by the change in the surface-band bending and the thickness of the depletion region.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Performance of a Heat Pump Water Heater in the Hot-Humid Climate, Windermere, Florida (Fact Sheet)

Over recent years, heat pump water heaters (HPWHs) have become more readily available and more widely adopted in the marketplace. For a 6-month period, the Building America team Consortium for Advanced Residential Buildings monitored the performance of a GE Geospring HPWH in Windermere, Florida. The study found that the HPWH performed 144% more efficiently than a traditional electric resistance water heater, saving approximately 64% on water heating annually. The monitoring showed that the domestic hot water draw was a primary factor affecting the system's operating efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Achieving Challenge Home in Affordable Housing in the Hot-Humid Climate

The Building America Partnership for Improved Residential Construction (BA-PIRC), one of the Building America research team leads, has partnered with two builders as they work through the Challenge Home certification process (now Zero Energy Ready Home) in one test home each. The builder partners participating in this cost-shared research are Southeast Volusia County Habitat for Humanity near Daytona, Florida and Manatee County Habitat for Humanity near Tampa, Florida. Both are affiliates of Habitat for Humanity International, a non-profit affordable housing organization. This research serves to identify viable technical pathways to meeting the CH criteria for other builders in the region. A further objective of this research is to identify gaps and barriers in the marketplace related to product availability, labor force capability, code issues, cost effectiveness, and business case issues that hinder or prevent broader adoption on a production scale.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗