Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heat transfer loop”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Cyclic plastic deformation behaviour of a directionally solidified nickel base superalloy at 850 °C: Damage micromechanisms

Highlights: • Isothermal LCF life of CM 247 DS is reduced using R = 0 instead of R = −1. • Reduction in LCF life is significant at lower values of Δε/2. • Reduction in fatigue life is attributed to the development of sustained mean stress. • Sustained mean stress prevents the slip transfer from γ-channels to γ′-precipitates. • Sustained mean stress promotes dislocation network formation and looping. - Abstract: Dislocation based deformation micromechanisms during low cycle fatigue deformation of nickel base superalloy CM 247 DS LC at 850 °C was investigated by conducting fatigue tests employing constant strain amplitudes for strain ratio (R) values of 0, −1 and carrying out extensive SEM and TEM examinations. Cyclic life of the alloy reduces for all fatigue tests conducted employing R = 0 in comparison with R = −1 owing to sustained mean stress developed during fatigue at R = 0. TEM examinations confirmed that sustained mean stress developed during low strain amplitude fatigue test (Δε/2 = 0.5%) using R = 0 condition prevented slip transfer from γ-channels to γ′-precipitates and resulted in the formation of dislocation substructures such as networks, nodes etc. and also promoted dislocation looping around γ′-precipitates. Lower fatigue life at R = 0 is mainly attributed to the development of these types of substructures, which promotes strain localization in both intra as well intergranular regions. Whereas, in specimen fatigue tested (Δε/2 = 0.5%) using R = −1 condition, shearing of γ′-precipitates by APB coupled dislocation and formation of stacking faults were observed. The formation and nature of stacking faults were analysed using weak beam imaging technique. Stacking fault formed during fatigue tests using R = −1 condition matured to micro-twins when Δε/2 value was increased to 0.8%. The mechanism of formation of these microtwins is discussed in detail. SEM based microstructural and fractographic examinations revealed that mean stress induced creep effect resulted in intergranular crack initiation and grain boundary cavitation during fatigue tests under R = 0 condition and therefore verified the facts revealed in TEM studies.

36 MATERIALS SCIENCE↗

Temperature Control with Two Parallel Small Loop Heat Pipes for GLM Program

The concept of temperature control of an electronic component using a single Loop Heat Pipe (LHP) is well established for Aerospace applications. Using two LHPs is often desirable for redundancy/reliability reasons or for increasing the overall heat source-sink thermal conductance. This effort elaborates on temperature controlling operation of a thermal system that includes two small ammonia LHPs thermally coupled together at the evaporator end as well as at the condenser end and operating "in parallel". A transient model of the LHP system was developed on the Thermal Desktop (TradeMark) platform to understand some fundamental details of such parallel operation of the two LHPs. Extensive thermal-vacuum testing was conducted with two thermally coupled LHPs operating simultaneously as well as with only one LHP operating at a time. This paper outlines the temperature control procedures for two LHPs operating simultaneously with widely varying sink temperatures. The test data obtained during the thermal-vacuum testing, with both LHPs running simultaneously in comparison with only one LHP operating at a time, are presented with detailed explanations.

0000↗

Thermal Analysis of a Uranium Silicide Miniplate Irradiation Experiment

This paper outlines the thermal analysis for the irradiation of high density uranium-silicide (U3Si2 dispersed in an aluminum matrix and clad in aluminum) booster fuel for a Boosted Fast Flux Loop designed to provide fast neutron flux test capability in the ATR. The purpose of this experiment (designated as Gas Test Loop-1 [GTL-1]) is two-fold: (1) to assess the adequacy of the U3Si2/Al dispersion fuel and the aluminum alloy 6061 cladding, and (2) to verify stability of the fuel cladding boehmite pre-treatment at nominal power levels in the 430 to 615 W/cm2 (2.63 to 3.76 Btu/s•in2) range. The GTL-1 experiment relies on a difficult balance between achieving a high heat flux, yet keeping fuel centerline temperature below a specified maximum value throughout an entire operating cycle of the reactor. A detailed finite element model was constructed to calculate temperatures and heat flux levels and to reveal which experiment parameters place constraints on reactor operations. Analyses were performed to determine the bounding lobe power level at which the experiment could be safely irradiated, yet still provide meaningful data under nominal operating conditions. Then, simulations were conducted for nominal and bounding lobe power levels under steady-state and transient conditions with the experiment in the reactor. Reactivity changes due to a loss of commercial power with pump coast-down to emergency flow or a standard in-pile tube pump discharge break were evaluated. The time after shutdown for which the experiment can be adequately cooled by natural convection cooling was determined using a system thermal hydraulic model. An analysis was performed to establish the required in-reactor cooling time prior to removal of the experiment from the reactor. The inclusion of machining tolerances in the numerical model has a large effect on heat transfer.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Experimental investigation of flow distribution in enhanced geothermal systems with deep eutectic solvent

Geothermal energy has been recognized as a valuable alternative to fossil fuels and nuclear power, as it is renewable and reliable. Enhanced Geothermal Systems (EGSs) have the potential to expand geothermal energy production by enabling access to previously untapped geothermal resources. Geothermal short-circuiting poses a significant challenge to EGS development, leading to reduced heat extraction. Deep Eutectic Solvent (DES) exhibits favorable thermal and rheological properties, making it a candidate for geothermal applications. Here, this paper examines Choline Chloride-Based Deep Eutectic Solvent (DES) as a working fluid in geothermal applications and its potential to mitigate geothermal short-circuiting. Hydraulic experiments using a dual fracture flow loop were conducted at high temperatures. The results showed that DES exhibited higher differential pressure behavior compared to water. Flow distribution results revealed that DES enhances flow allocation within the small fracture, particularly when a temperature difference exists between fractures. Specifically, DES increased flow distribution by an average of 11% when the temperature difference was 85°C, and by 13% when the difference was 45°C, relative to water. These findings suggest that DES responds to thermal fracture differences, making it a potential remedy to address geothermal short-circuiting.

15 GEOTHERMAL ENERGY↗

As-Run Thermal Analysis of the GTL-1 Experiment Irradiated in the ATR South Flux Trap

The GTL-1 experiment was conducted to assess corrosion the performance of the proposed Boosted Fast Flux Loop booster fuel at heat flux levels {approx}30% above the design operating condition. Sixteen miniplates fabricated from 25% enriched, high-density U3Si2/Al dispersion fuel with 6061 aluminum cladding were subjected to peak beginning of cycle (BOC) heat fluxes ranging from 411 W/cm2 to 593 W/cm2. Miniplates fabricated with three different fuel variations (without fines, annealed, and with standard powder) performed equally well, with negligible irradiation-induced swelling and a normal fission density gradient. Both the standard and the modified prefilm procedures produced hydroxide films that adequately protected the miniplates from failure. A detailed finite element model was constructed to calculate temperatures and heat flux for an as-run cycle average effective south lobe power of 25.4 MW(t). Results of the thermal analysis are given at four times during the cycle: BOC at 0 effective full power days (EFPD), middle of cycle (MOC) at 18 EFPD, MOC at 36 EFPD, and end of cycle at 48.9 EFPD. The highest temperatures and heat fluxes occur at the BOC and decrease in a linear manner throughout the cycle. Miniplate heat flux levels and fuel, cladding, hydroxide, and coolant-hydroxide interface temperatures were calculated using the average measured hydroxide thickness on each miniplate. The hydroxide layers are the largest on miniplates nearest to the core midplane, where heat flux and temperature are highest. The hydroxide layer thickness averages 20.4 {mu}m on the six hottest miniplates (B3, B4, C1, C2, C3, and C4). This tends to exacerbate the heating of these miniplates, since a thicker hydroxide layer reduces the heat transfer from the fuel to the coolant. These six hottest miniplates have the following thermal characteristics at BOC: (1) Peak fuel centerline temperature >300 C; (2) Peak cladding temperature >200 C; (3) Peak hydroxide temperature >190 C; (4) Peak hydroxide-water interface temperature >140 C; and (5) Peak heat flux >565 W/cm2.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Performance Analyses of Passive Containment Cooling System for a Concrete Type Containment

The containment of nuclear power plants is the final barrier to keep the radioactive materials from uncontrolled release to the environment. To keep the containment integrity, pressure and temperature must be controlled by the spray system which relies on active components for PWRs with a concrete containment. To achieve a passive means to keep the containment integrity, therefore, cooling should be achieved by forming a natural circulation loop between internal cooling devices connected to an external heat sink. A system like this is often called Passive Containment Cooling System (PCCS). In the early phase of APR-1400 development, this concept was studied and VVER-1200 is also known to adopt the PCCS. The PCCS consists of a cooling device installed at the inside of the containment which is a tube-bank type heat exchanger where cooling occurs at the exterior of the tubes and a heat sink which is called Passive Containment Cooling Tank (PCCT) located at the outside of the containment on the top of the auxiliary building. In this paper, we introduce performance analysis results, utilizing the GOTHIC computer code. The PCCS performance analysis model was developed for APR-1400 which has a thermal power of 4000 MW and considers PCCS as an option to improve its safety characteristics. The PCCS which is considered in this paper is to cope with both Design Basis and Severe Accidents, considering SBO conditions. The pressure and temperature transients due to the Loss of Coolant Accident (LOCA) were analyzed with and without PCCS together with a normal case using the spray system. And, in particular, limitations of the PCCS in regard to mission time will be discussed. Through this study, it was found that the PCCS being considered as an option to improve the safety of APR-1400 can have almost same capability to control the containment pressure for LBLOCA as the containment spray system does. Although it would depends on the heat removal capacity of a given design such as the size of the heat transfer area, the PCCS could even replace the containment spray system. However, the PCCS may lose its capability after 24 hours as its temperature reaches that of the containment atmosphere. To extend the mission time of PCCS, either cooling or supplementary cold water needs to be provided to the external heat sink of PCCS. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

High operating temperature heat transfer fluids for solar thermal power generation. Final report

This is the final technical report for the DOE MURI project on developing high-operating temperature heat transfer fluids for solar thermal power generation. This project aimed to evaluate liquid metals as a heat-transport fluid and potential energy storage medium for concentrated solar powered (CSP) systems. The project consisted of five phases, starting with fluid selection and screen and ending with potential CSP integration. The initial fluid selection arrived at heavy liquid metals as candidate fluids such as lead bismuth eutectic (LBE) as the prime liquid-alloy candidate to be studied, given the conditions above. Fifty-seven liquid compositions were initially identified with liquidus temperatures lower than 200°C, composed of elements that provide no driving force to the reduction of Cr 2 O 3 or Al 2 O 3 passivation layers in pipe material which is required for corrosion prevention. LBE was identified as the primary candidate fluid after these compositions were compared against computational thermodynamic modeling to screen all of the selected systems that would be compatible with our design objectives. Twenty-eight of these compositions were also investigated with the rapid characterization methods; the accuracies of the liquidus temperature and the specific heats predicted by the computations were better than 3 percent and 9 percent, respectively. We conducted numerus corrosion tests of various Fe-Cr-Al based steels in LBE and its variants at temperate as high as 800°C. It was found that minor additions to the liquid did not provide sufficient corrosion protection to warrant their use in real applications. Furthermore, we investigated the detailed mechanism of corrosion between heavy liquid metal and the pipe material at these very high temperatures. A liquid metal loop was constructed to operate at these high temperatures. The loop construction and operation lead to valuable lessons learned that will be needed for industrial scale loops. Furthermore, we learned that electromagnetic pumps at these extreme temperatures will have to be reengineered and redesigned to be used for CSP applications.

14 SOLAR ENERGY↗

Use of DRACS to Enhance HTGRs Passive Safety and Economy

This paper discusses the use of DRACS to Enhance HTGRs Passive Safety and Economy. One of the important requirements for Gen. IV High Temperature Gas Cooled Reactors (HTGR) is passive safety. Currently all the HTGR designs use Reactor Vessel Auxiliary Cooling System (RVACS) for passive decay heat removal. [1] The decay heat first is transferred to core barrel by conduction and radiation, and then to reactor vessel by thermal radiation and convection; finally the decay heat is transferred to natural circulated air or water systems. RVACS can be characterized as a surface based decay heat removal system. Similar concepts have been widely used in sodium cooled fast reactor (SFR) designs, advanced light water reactors like AP1000. The RVACS is especially suitable for smaller power reactors since small systems have relatively larger surface area. RVACS tends to be less expensive. However, it limits the largest achievable power level for modular HTGRs due to the mismatch between the reactor power (proportional to volume) and decay heat removal capability (proportional to surface). When the relative decay heat removal capability is reduced, the peak fuel temperature increases, even close to the design limit. Annual designs with internal reflector can mitigate this effect therefore further increase the power. Another way to increase power is to increase power density. However, it is also limited by the decay heat removal capability. Besides safety, HTGRs also need to be economical in order to compete with other reactor designs. The limit of decay heat removal capability set by using RVACS has affected the economy of HTGRs. Forsberg [2] pointed out other disadvantages of using RVACS such as conflicting functional requirements for the reactor vessel and scaling distortion for integral effect test of the system performance. A potential alternative solution is to use a volume based passive decay removal system, call Direct Reactor Auxiliary Cooling Systems (DRACS), to remove or mitigate the limitation on decay heat removal capability. DRACS has been widely used in SFR designs and in liquid salt cooled high temperature reactors. The containment cooling system in BWR is another example of volume based decay removal systems. DRACS composes of natural circulation loops with two sets of heat exchangers, one in reactor side and another is in environment side. DRACS has the benefits of increasing the power as needed (scalability) and modularity. This paper introduces the concept of using DRACS to enhance HTGRs passive safety and economy.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

FY22 Status Report on the ART-GCR CMVB and CNWG International Collaborations

This work presents the numerical model for the high temperature test reactor (HTTR) loss of forced cooling (LOFC) experiment with the INL codes Griffin, BISON, and RELAP-7, based on the Multiphysics Object-Oriented Simulation Environment (MOOSE) framework. Promising results were obtained, with the overall behavior of the reactor successfully captured. Changes in the heat transfer coupling, as compared to the fiscal year (FY)-21 model, enabled drastic improvement of the steady-state solution, both in terms of computational time and global energy discrepancies. The former was reduced by a factor of roughly 60, whereas the latter decreased from 11% to less than 2%. Furthermore, the discrepancy in the steady-state multiplication factor was improved from +2,300 and +2,900 pcm (for the 30 and 9 MW cases) to -700 and +1,200 pcm, respectively, and now falls well within the large measurement uncertainties stemming from graphite impurities. Validation of the Monte Carlo model used to generate cross sections was also performed against available measurements. Though significant, the discrepancies remain acceptable overall in light of the large uncertainty. Numerous improvements are still needed to better compare with the experiment involving the 9 MW case and to instill greater confidence in the model’s ability to accurately predict the 30 MW behavior. Specifically, the power levels predicted by the 9 MW transient simulation following re-criticality remain low, pointing to an underestimation of the passive cooling of the core. A key aspect of future work will be to better understand the flow pattern during the LOFC event, particularly to determine if natural or forced convection is occurring inside the reactor pressure vessel (RPV). More generally, additional validation data would be immensely useful for further enhancing the numerical model and better matching the experiments. In addition, a more sophisticated thermal-hydraulics model that simulates all the channels as a single system model should be considered to take into account the rest of the primary loop. Finally, even if the results are in better agreement with the experiments, sensitivity analysis and uncertainty quantification will be necessary to evaluate the model uncertainty.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The origin of the solar wind

The high speed solar wind, which is associated with coronal holes and unipolar interplanetary magnetic field, has now been observed in situ beyond 0.3 a.u. and at latitudes up to 80 degrees. Its important characteristics are that it is remarkably steady in terms of flow properties and composition and that the ions, especially minor species, are favored in terms of heating and acceleration. We have proposed that the high speed wind, with its associated coronal holes, forms the basic mode of solar wind flow. In contrast, the low speed wind is inherently non-stationary, filamentary and not in equilibrium with conditions at the coronal base. It is presumably the result of continual reconfigurations of the force-free magnetic field in the low-latitude closed corona which allow trapped plasma to drain away along transiently open flux tubes. Observations of high speed solar wind close to its source are hampered by the essential heterogeneity of the corona, even at sunspot minimum. In particular it is difficult to determine more than limits to the density, temperature and wave amplitude near the coronal base as a result of contamination from fore- and back-ground plasma. We interpret the observations as indicating that the high speed solar wind originates in the chromospheric network, covering only about 1% of the surface of the sun, where the magnetic field is complex and not unipolar. As a result of small-scale reconnection events in this 'furnace', Alfven waves are generated with a flat spectrum covering the approximate range 10 kHz to 10 Hz. The plasma is likely to be produced as a result of downwards thermal conduction and possibly photoionization at the top of the low density chromospheric interface to the furnace, thus controlling the mass flux in the wind. The immediate source of free (magnetic) energy is in the form of granule-sized loops which are continually carried into the network from the sides. The resulting wave spectrum is such that energy can be efficiently transferred to the ions within a few solar radii of the base of the corona, favoring heavy species and creating stable, fast solar wind.

Axford, W. I.↗

Anisotropic electronic screening and damping in magnetars

We calculate the screening of the ion-ion potential due to electrons, in the presence of a large background magnetic field, at densities of relevance to neutron star crusts. Using the standard approach to incorporate electronic screening through the one-loop polarization function, we show that the magnetic field produces important corrections at both short and long distances. In extreme fields, realized in highly magnetized neutron stars called magnetars, electrons occupy only the lowest Landau levels in the relatively low-density region of the crust. Here our results show that the screening length for Coulomb interactions between ions can be smaller than the inter-ion spacing. More interestingly, we find that the screening is anisotropic, and the screened potential between two static charges exhibits long-range Friedel oscillations parallel to the magnetic field. This long-range oscillatory behavior is likely to affect the lattice structure of ions and can possibly create anisotropic structures in the magnetar crusts. We also calculate the imaginary part of the electron polarization function, which determines the spectrum of electron-hole excitations and plays a role in damping lattice phonon excitations. We demonstrate that even for modest magnetic fields this damping is highly anisotropic and will likely lead to anisotropic phonon heat transport in the outer neutron star crust.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

DATA-DRIVEN RADIATIVE HYDRODYNAMIC MODELING OF THE 2014 MARCH 29 X1.0 SOLAR FLARE

Spectroscopic observations of solar flares provide critical diagnostics of the physical conditions in the flaring atmosphere. Some key features in observed spectra have not yet been accounted for in existing flare models. Here we report a data-driven simulation of the well-observed X1.0 flare on 2014 March 29 that can reconcile some well-known spectral discrepancies. We analyzed spectra of the flaring region from the Interface Region Imaging Spectrograph ( IRIS ) in Mg ii h and k, the Interferometric BIdimensional Spectropolarimeter at the Dunn Solar Telescope (DST/IBIS) in H α 6563 Å and Ca ii 8542 Å, and the Reuven Ramaty High Energy Solar Spectroscope Imager ( RHESSI ) in hard X-rays. We constructed a multithreaded flare loop model and used the electron flux inferred from RHESSI data as the input to the radiative hydrodynamic code RADYN to simulate the atmospheric response. We then synthesized various chromospheric emission lines and compared them with the IRIS and IBIS observations. In general, the synthetic intensities agree with the observed ones, especially near the northern footpoint of the flare. The simulated Mg ii line profile has narrower wings than the observed one. This discrepancy can be reduced by using a higher microturbulent velocity (27 km s{sup −1}) in a narrow chromospheric layer. In addition, we found that an increase of electron density in the upper chromosphere within a narrow height range of ≈800 km below the transition region can turn the simulated Mg ii line core into emission and thus reproduce the single peaked profile, which is a common feature in all IRIS flares.

79 ASTRONOMY AND ASTROPHYSICS↗

Device Scale Modeling of Solvent Absorption using MFIX-TFM

Recent climate change is largely attributed to greenhouse gases (e.g., carbon dioxide, methane) and fossil fuels account for a large majority of global CO 2 emissions. That said, fossil fuels will continue to play a significant role in the generation of power for the foreseeable future. The extent to which CO 2 is emitted needs to be reduced, however, carbon capture and sequestration are also necessary actions to tackle climate change. Different approaches exist for CO 2 capture including both post-combustion and pre-combustion technologies, oxy-fuel combustion and/or chemical looping combustion. The focus of this effort is on post-combustion solvent-absorption technology. To apply CO 2 technologies at commercial scale, the availability and maturity and the potential for scalability of that technology need to be considered. Solvent absorption is a proven technology but not at the scale needed by typical power plant. The scale up and down and design of laboratory and commercial packed bed reactors depends heavily on the specific knowledge of two-phase pressure drop, liquid holdup, the wetting efficiency and mass transfer efficiency as a function of operating conditions. Simple scaling rules often fail to provide proper design. Conventional reactor design modeling approaches will generally characterize complex non-ideal flow and mixing patterns using simplified and/or mechanistic flow assumptions. While there are varying levels of complexity used within these approaches, none of these models resolve the local velocity fields. Consequently, they are unable to account for important design factors such as flow maldistribution and channeling from a fundamental perspective. Ideally design would be aided by development of predictive models based on truer representation of the physical and chemical processes that occur at different scales. Computational fluid dynamic (CFD) models are based on multidimensional flow equations with first principle foundations. CFD models can include a more accurate physical description of flow processes and be modified to include more complex behavior. Wetting performance and spatial liquid distribution inside the absorber are recognized as weak areas of knowledge requiring further investigation. CFD tools offer a possible method to investigating such topics and gaining a better understanding of their influence on reactor performance. This report focuses first on describing a hydrodynamic model for countercurrent gas-liquid flow through a packed column and then on the chemistry, heat and mass transfer specific to CO 2 absorption using monoethanolamine (MEA). The indicated model is implemented in MFIX, a CFD open source software package. The user defined functions needed to build this model are described in detail along with the keywords for the corresponding input file. A test case is outlined along with a few results. The example serves to briefly illustrate the developed CFD tool and its potential capability to investigate solvent absorption.

09 BIOMASS FUELS↗

Impact of central ECCD on steady-state hybrid scenario in DIII-D

“Steady-state” hybrid plasmas in DIII-D with zero surface loop voltage have been maintained for up to two current relaxation times using 3.4 MW of central electron cyclotron current drive (ECCD). In addition to driving ≈0.2 MA of plasma current, central ECCD leads to significant changes in Alfvén eigenmode (AE) activity and thermal transport. For neutral-beam-only heating, strong AE activity is observed that causes a ∼35% degradation in the neutron rate. With central ECCD this AE activity is suppressed, replaced by a bursty energetic particle mode that appears more benign as the neutron rate is closer to the classical value. The electron thermal diffusivity increases by ≈50% for 2.4 MW of ECCD compared to neutral-beam-only cases. Fortunately, the global thermal confinement factor remains the same (H{sub 98y2}=1.4) as the higher thermal transport for P{sub EC}=2.4 MW hybrids is offset by the decreased fast ion transport resulting from AE suppression.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Temperature Oscillation in a Loop Heat Pipe with Gravity Assist

ATLAS Laser Thermal Control System (LTCS) thermal vacuum testing where the condenser-radiator was placed in a vertical position, it was found that the loop heat pipe (LHP) reservoir required much more control heater power than the analytical model had predicted. The required control heater power was also higher than the liquid subcooling entering the reservoir using the measured temperatures and the calculated mass flow rate based on steady state LHP operation. This presentation describes the investigation of the LHP behaviors under a gravity assist mode with a very cold radiator sink temperature and a large thermal mass attached to the evaporator. It is concluded that gravity caused the cold liquid to drop from the condenser-radiator to the reservoir, resulting in a rapid decrease of the reservoir temperature. When the reservoir temperature was increasing, a reverse flow occurred in the liquid line, carrying warm liquid to the condenser-radiator. Both events consumed the reservoir control heater power. The fall and rise of the reservoir temperature also caused the net heat input to the evaporator to vary due to the release and storage of the sensible heat of the thermal mass. The combination of these effects led to a persistent reservoir temperature oscillation and a repeated influx of cold liquid from the condenser. This was the root cause of the extraordinary high control heater power requirement in the LTCS TV test. Without gravity assist, such a persistent temperature oscillation will not be present.

000↗

Basic research in solar physics

This grant, dating back more than 20 years has supported a variety of investigations of the chromospheres and coronae of the Sun and related cool stars by the Principal Investigator, his postdocs and graduate students, and colleagues at other institutions. This work involved studies of radiative transfer and spectral line formation theory, and the application of these techniques to the analysis of spectra obtained from space and ground-based observatories in the optical, ultraviolet, x-ray and radio portions of the spectrum. Space observations have included the analysis of spectra from OSO-7, Skylab, SMM, and the HRTS rocket experiments. Recent work has concentrated on the interaction of magnetic fields, plasma and radiation in the outer atmospheres of the Sun and other magnetically active stars with different fundamental parameters. Our study of phenomena common to the Sun and stars, the 'solar-stellar connection', can elucidate the fundamental physics, because spatially-resolved observations of the Sun provide us with the 'groundtruth,' while interpretation of stellar data permit us to isolate those parameters critical to stellar activity. Recently, we have studied the differences in physical properties between solar regions of high magnetic flux density and the surrounding plasma. High-resolution CN and CO spectroheliograms have been used to model the thermal inhomogeneities driven by unstable CO cooling, and we have analyzed spatially resolved UV spectra from HRTS to model the thermal structure and energy balance of small-scale structures. The study of nonlinear relations between atmospheric radiative losses and the photospheric magnetic flux density has been continued. We have also proposed a new model for the decay of plages by random walk diffusion of magnetic flux. Our analysis of phenomena common to the Sun and stars included the application of available spectroscopic diagnostics, establishing evidence that the atmospheres of the least active stars are heated at a 'basal' rate that is also found in the centers of solar supergranules, and using the Doppler-imaging technique to measure the position, size, and brightness of stellar active regions. We are computing multi-component models for solar and stellar atmospheres, and models for coronal loops and for the transition-region down flows. The study of solar and stellar flares permits us to assess the role of turbulent energy transport, to pinpoint the mechanism behind Type I radio bursts, to determine whether plasma radiation or cyclotron maser is responsible for microwave flares on M dwarfs, and to extend our knowledge of the basic physics pertinent to cyclotron-maser processes operating on the Sun.

Linsky, Jeffrey L.↗

Demonstration of High-Temperature Calcium-Based Thermochemical Energy Storage System for use with Concentrating Solar Power Facilities

Thermochemical energy storage (TCES) systems offer several advantages over sensible heat storage via molten salts for concentrating solar power (CSP) including: energy density, cost, indefinite storage time, and no risk of freezing. SR’s TCES system utilizes a CaO-based carbonation reaction at high temperature in a fixed bed heat exchanger reactor. The SunShot APOLLO project focuses on the validation of the calcium oxide sorbent for capacity, durability, system economics, and demonstration of the system at a small pilot scale, including system control and operation in simulated on-sun conditions, discharging at 720°C. Under phase I SR completed evaluation of the sorbent loaded in a single-channel heat exchanger reactor. The major accomplishments of phase II are: Design, fabrication and commissioning of a 4 kWhth pilot plant (50x capacity increase from previous bench scale) with a closed-loop CO 2 system, and a commercially relevant heat exchange reactor. The heat exchange reactor has been designed with state-of-the-art modeling tools to ensure 1) sufficient lifetime of the Incoloy body and 2) performance of the packed bed reactor will be adequate to meet the milestones. The rest of the pilot system has been designed with off-the shelf components to maximize reliability and cost effectiveness. The system is highly instrumented and capable of time resolved, independent measurements of the heat and mass balances respectively. Major developments in the technoeconomic analysis (TEA) include 1) reduction of the cost of membrane gas storage for the near-term and future systems and 2) integration with liquid metal receivers and particle receivers for higher decarbonation temperatures and pressures which reduced the cost of gas compression and increased system efficiency. The result are three scenarios with costs bases of 21.9 dollars, 14.3 dollars, and 10.9 dollars/kWhth corresponding to a real LCOE of 59, 57, 56 dollars/MWhe, respectively. The basic operations of the energy storage system were demonstrated for carbonation (discharging) and decarbonation (charging) over short time periods. Excellent control of the CO 2 mass balance across the reactor was achieved with mass flow controllers and the basic operation of the level control of the CO 2 gas bladder was achieved. The system was apparently free from leaks and operated continuously for 18 days with no mechanical failures, thus meeting milestone 2.5.5. The major shortcomings of the system had to do with the controls which prevented us from deep cycling and or reaching high cycles. We were unable to decarbonate (charge) the system for more than a few minutes at a time, which was much shorter than the design target of 10 hrs. This issue could not be resolved due to facility availability and contract closure. One major finding is that CaO-based TCES is most cost efficient when charged with HTF (heat transfer fluid) temperatures >850°C to reach the round-trip exergy efficiency and system cost targets which are higher temperatures than those considered for Gen 3 CSP. Many of the balance of plant components do not exist today, however we are encouraged by our findings that in general with more work we are able to reduce the capital cost, for example with the membrane gas storage, which is an innovative component in itself. The CaO-based TCES system has potential to meet the latest SunShot 2030 goals of LCOE at 50 dollars/MWhe with capital costs of <11/kWhth.

14 SOLAR ENERGY↗

Demonstration of High-Temperature Calcium-Based Thermochemical Energy Storage System for use with Concentrating Solar Power Facilities

Thermochemical energy storage (TCES) systems offer several advantages over sensible heat storage via molten salts for concentrating solar power (CSP) including: energy density, cost, indefinite storage time, and no risk of freezing. SR’s TCES system utilizes a CaO-based carbonation reaction at high temperature in a fixed bed heat exchanger reactor. The SunShot APOLLO project focuses on the validation of the calcium oxide sorbent for capacity, durability, system economics, and demonstration of the system at a small pilot scale, including system control and operation in simulated on-sun conditions, discharging at 720°C. Under phase I SR completed evaluation of the sorbent loaded in a single-channel heat exchanger reactor. The major accomplishments of phase II are: Design, fabrication and commissioning of a 4 kWhth pilot plant (50x capacity increase from previous bench scale) with a closed-loop CO 2 system, and a commercially relevant heat exchange reactor. The heat exchange reactor has been designed with state-of-the-art modeling tools to ensure 1) sufficient lifetime of the Incoloy body and 2) performance of the packed bed reactor will be adequate to meet the milestones. The rest of the pilot system has been designed with off-the shelf components to maximize reliability and cost effectiveness. The system is highly instrumented and capable of time resolved, independent measurements of the heat and mass balances respectively. Major developments in the technoeconomic analysis (TEA) include 1) reduction of the cost of membrane gas storage for the near-term and future systems and 2) integration with liquid metal receivers and particle receivers for higher decarbonation temperatures and pressures which reduced the cost of gas compression and increased system efficiency. The result are three scenarios with costs bases of 21.9 dollars, 14.3 dollars, and 10.9 dollars/kWh th corresponding to a real LCOE of 59, 57, 56 dollars/MW he , respectively. The basic operations of the energy storage system were demonstrated for carbonation (discharging) and decarbonation (charging) over short time periods. Excellent control of the CO 2 mass balance across the reactor was achieved with mass flow controllers and the basic operation of the level control of the CO 2 gas bladder was achieved. The system was apparently free from leaks and operated continuously for 18 days with no mechanical failures, thus meeting milestone 2.5.5. The major shortcomings of the system had to do with the controls which prevented us from deep cycling and or reaching high cycles. We were unable to decarbonate (charge) the system for more than a few minutes at a time, which was much shorter than the design target of 10 hrs. This issue could not be resolved due to facility availability and contract closure. One major finding is that CaO-based TCES is most cost efficient when charged with HTF (heat transfer fluid) temperatures >850°C to reach the round-trip exergy efficiency and system cost targets which are higher temperatures than those considered for Gen 3 CSP. Many of the balance of plant components do not exist today, however we are encouraged by our findings that in general with more work we are able to reduce the capital cost, for example with the membrane gas storage, which is an innovative component in itself. The CaO-based TCES system has potential to meet the latest SunShot 2030 goals of LCOE at 50 $/MW he with capital costs of <11/kWh th .

14 SOLAR ENERGY↗