Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “guide”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Cone Beam CT Image Guidance for Intracranial Stereotactic Treatments: Comparison With a Frame Guided Set-Up

Purpose: An analysis is performed of the setup errors measured by a kV cone beam computed tomography (CBCT) for intracranial stereotactic radiotherapy (SRT) patients immobilized by a thermoplastic mask and a bite-block and positioned using stereotactic coordinates. We evaluated the overall positioning precision and accuracy of the immobilizing and localizing systems. The potential of image-guided radiotherapy to replace stereotactic methods is discussed. Methods and Materials: Fifty-seven patients received brain SRT. After a frame-guided setup, before each fraction (131 fractions), a CBCT was acquired and the detected displacements corrected online. Translational and rotational errors were analyzed calculating overall mean and standard deviation. A separate analysis was performed for bite-block (in conjunction with mask) and for simple thermoplastic mask. Interobserver variability for CBCT three-dimensional registration was assessed. The residual error after correction and intrafractional motion were calculated. Results: The mean module of the three-dimensional displacement vector was 3.0 {+-} 1.4 mm. Setup errors for bite block and mask were smaller (2.9 {+-} 1.3 mm) than those for thermoplastic mask alone (3.2 {+-} 1.5 mm), but statistical significance was not reached (p = 0.15). Interobserver variability was negligible. The maximum margin calculated for residual errors and intra fraction motion was small but not negligible (1.57 mm). Conclusions: Considering the detected setup errors, daily image guidance is essential for the efficacy of SRT treatments when mask immobilization is used, and even when a bite-block is used in conjunction. The frame setup is still used as a starting point for the opportunity of rotational corrections. Residual margins after on-line corrections must be evaluated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Magnetic Resonance Imaging-Guided Intracavitary Brachytherapy for Cancer of the Cervix

Purpose: To determine the feasibility and benefits of optimized magnetic resonance imaging (MRI)-guided brachytherapy (BT) for cancer of the cervix. Methods and Materials: A total of 20 patients with International Federation of Gynecology and Obstetrics Stage IB-IV cervical cancer had an MRI-compatible intrauterine BT applicator inserted after external beam radiotherapy. MRI scans were acquired, and the gross tumor volume at diagnosis and at BT, the high-risk (HR) and intermediate-risk clinical target volume (CTV), and rectal, sigmoid, and bladder walls were delineated. Pulsed-dose-rate BT was planned and delivered in a conventional manner. Optimized MRI-based plans were developed and compared with the conventional plans. Results: The HR CTV and intermediate-risk CTV were adequately treated (the percentage of volume treated to {>=}100% of the intended dose was >95%) in 70% and 85% of the patients with the conventional plans, respectively, and in 75% and 95% of the patients with the optimized plans, respectively. The minimal dose to the contiguous 2 cm{sup 3} of the rectal, sigmoid, and bladder wall volume was 16 {+-} 6.2, 25 {+-} 8.7, and 31 {+-} 9.2 Gy, respectively. With MRI-guided BT optimization, it was possible to maintain coverage of the HR-CTV and reduce the dose to the normal tissues, especially in patients with small tumors at BT. In these patients, the HR percentage of volume treated to {>=}100% of the intended dose approached 100% in all cases, and the minimal dose to the contiguous 2-cm{sup 3} of the rectum, sigmoid, and bladder was 12-32% less than with conventional BT planning. Conclusion: MRI-based BT for cervical cancer has the potential to optimize primary tumor dosimetry and reduce the dose to critical normal tissues, particularly in patients with small tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Role of Seminal Vesicle Motion in Target Margin Assessment for Online Image-Guided Radiotherapy for Prostate Cancer

Purpose: For patients with intermediate- and high-risk prostate cancer, the seminal vesicles (SVs) are included in the clinical target volume (CTV). The purposes of this study are to investigate interfraction motion characteristics of the SVs and determine proper margins for online computed tomography image guidance. Methods and Materials: Twenty-four patients, each with 16 daily helical computed tomography scans, were included in this study. A binary image mask was used for image registration to determine daily organ motion. Two online image-guided radiotherapy strategies (prostate only and prostate + SVs) were simulated in a hypofractionated scheme. Three margin designs were studied for both three-dimensional conformal radiotherapy and intensity-modulated radiotherapy (IMRT). In prostate-only guidance, Margin A was uniformly applied to the whole CTV, and Margin B was applied to the SVs with a fixed 3-mm prostate margin. In prostate plus SV guidance, Margin C was uniformly applied to the CTV. The minimum margins were sought to satisfy the criterion that minimum cumulative CTV dose be more than those of the planning target volume in the plan for greater than 95% of patients. Results: The prostate and SVs move significantly more in the anterior-posterior and superior-inferior than right-left directions. The anterior-posterior motion of the prostate and SVs correlated (R{sup 2} = 0.7). The SVs move significantly more than the prostate. The minimum margins found were 2.5 mm for three-dimensional conformal radiotherapy and 4.5, 4.5, and 3.0 mm for Margins A, B, and C for IMRT, respectively. Margins for IMRT were larger, but the irradiated volume and doses to critical structures were smaller. Minimum margins of 4.5 mm to the SVs and 3 mm to the prostate are recommended for IMRT with prostate-only guidance. Conclusions: The SVs move independently from the prostate gland, and additional margins are necessary for image-guided radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hypofractionated Boost With High-Dose-Rate Brachytherapy and Open Magnetic Resonance Imaging-Guided Implants for Locally Aggressive Prostate Cancer: A Sequential Dose-Escalation Pilot Study

Purpose: To evaluate the feasibility, tolerance, and preliminary outcome of an open MRI-guided prostate partial-volume high-dose-rate brachytherapy (HDR-BT) schedule in a group of selected patients with nonmetastatic, locally aggressive prostatic tumors. Methods and Materials: After conventional fractionated three-dimensional conformal external radiotherapy to 64-64.4 Gy, 77 patients with nonmetastatic, locally aggressive (e.g., perineural invasion and/or Gleason score 8-10) prostate cancer were treated from June 2000 to August 2004, with HDR-BT using temporary open MRI-guided {sup 192}Ir implants, to escalate the dose in the boost region. Nineteen, 21, and 37 patients were sequentially treated with 2 fractions of 6 Gy, 7 Gy, and 8 Gy each, respectively. Neoadjuvant androgen deprivation was given to 62 patients for 6-24 months. Acute and late toxicity were scored according to the Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer scoring system. Results: All 77 patients completed treatment as planned. Only 2 patients presented with Grade >=3 acute urinary toxicity. The 3-year probability of Grade >=2 late urinary and low gastrointestinal toxicity-free survival was 91.4% +- 3.4% and 94.4% +- 2.7%, respectively. Rates of 3-year biochemical disease-free survival (bDFS) and disease-specific survival were 87.1% +- 4.1% and 100%, respectively. Conclusions: Boosting a partial volume of the prostate with hypofractionated HDR-BT for aggressive prostate cancer was feasible and showed limited long-term toxicity, which compared favorably with other dose-escalation methods in the literature. Preliminary bDFS was encouraging if one considers the negatively selected population of high-risk patients in this study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Study on Target Positioning Error and Its Impact on Dose Variation in Image-Guided Stereotactic Body Radiotherapy for the Spine

Purpose: To investigate the amount of target positioning error and evaluate its dosimetric impact during image-guided stereotactic body radiotherapy for single-fraction spine treatment. Methods and Materials: A prescription dose of 15 Gy and five to nine coplanar intensity-modulated beams were used. The patient was immobilized with a custom-fit vacuum mold, and the target was localized with a volumetric cone-beam CT image. A robotic couch with six degrees of freedom was used for target adjustment. For evaluation a cone-beam CT image was obtained at the end of treatment. Both target positioning error and its dosimetric impact were investigated for the first 9 cases. Results: For cases studied, translational errors were 0.9 {+-} 0.5 mm (lateral), 1.2 {+-} 0.9 mm (longitudinal), 0.7 {+-} 0.6 mm (vertical), and 1.8 {+-} 1.0 mm (vector), and rotational errors were 1.6 deg. {+-} 1.3 deg. (pitch), 0.8 deg. {+-} 0.9 deg. (roll), and 0.8 deg. {+-} 0.4{sup o} (yaw). For the clinical target volume, D{sub 95} (dose to 95% of target volume), D{sub 90}, D{sub max}, and D{sub mean} were evaluated. Only 1 case showed significant dose variations, reaching up to 18% in D{sub 95}. The spinal cord dose was evaluated by observing D{sub 0.1} (dose to 0.1 cm{sup 3}), D{sub 0.5}, D{sub 1.0}, and D{sub max}. Although 1 case showed a dose change reaching up to 30% in D{sub max}, cord dose was within the planning tolerance limit in all but 2 cases (3% higher in one and 0.4% higher in the other). Conclusion: The implemented image-guided stereotactic body radiotherapy provides precise target localization. However, despite reasonably precise spatial precision, dosimetric perturbation can be significant because of both extremely steep dose gradients and close distances between the target and the spinal cord.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose Recalculation and the Dose-Guided Radiation Therapy (DGRT) Process Using Megavoltage Cone-Beam CT

Purpose: At University of California San Francisco, daily or weekly three-dimensional images of patients in treatment position are acquired for image-guided radiation therapy. These images can be used for calculating the actual dose delivered to the patient during treatment. In this article, we present the process of performing dose recalculation on megavoltage cone-beam computed tomography images and discuss possible strategies for dose-guided radiation therapy (DGRT). Materials and Methods: A dedicated workstation has been developed to incorporate the necessary elements of DGRT. Patient image correction (cupping, missing data artifacts), calibration, completion, recontouring, and dose recalculation are all implemented in the workstation. Tools for dose comparison are also included. Examples of image correction and dose analysis using 6 head-and-neck and 2 prostate patient datasets are presented to show possible tracking of interfraction dosimetric endpoint variation over the course of treatment. Results: Analysis of the head-and-neck datasets shows that interfraction treatment doses vary compared with the planning dose for the organs at risk, with the mean parotid dose and spinal cord D{sub 1} increasing by as much as 52% and 10%, respectively. Variation of the coverage to the target volumes was small, with an average D{sub 5} dose difference of 1%. The prostate patient datasets revealed accurate dose coverage to the targeted prostate and varying interfraction dose distributions to the organs at risk. Conclusions: An effective workflow for the clinical implementation of DGRT has been established. With these techniques in place, future clinical developments in adaptive radiation therapy through daily or weekly dosimetric measurements of treatment day images are possible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Experience With Image-Guided Radiotherapy in an Accelerated Partial Breast Intensity-Modulated Radiotherapy Protocol

Purpose: To explore the feasibility of fiducial markers for the use of image-guided radiotherapy (IGRT) in an accelerated partial breast intensity modulated radiotherapy protocol. Methods and Materials: Nineteen patients consented to an institutional review board approved protocol of accelerated partial breast intensity-modulated radiotherapy with fiducial marker placement and treatment with IGRT. Patients (1 patient with bilateral breast cancer; 20 total breasts) underwent ultrasound guided implantation of three 1.2- x 3-mm gold markers placed around the surgical cavity. For each patient, table shifts (inferior/superior, right/left lateral, and anterior/posterior) and minimum, maximum, mean error with standard deviation were recorded for each of the 10 BID treatments. The dose contribution of daily orthogonal films was also examined. Results: All IGRT patients underwent successful marker placement. In all, 200 IGRT treatment sessions were performed. The average vector displacement was 4 mm (range, 2-7 mm). The average superior/inferior shift was 2 mm (range, 0-5 mm), the average lateral shift was 2 mm (range, 1-4 mm), and the average anterior/posterior shift was 3 mm (range, 1 5 mm). Conclusions: This study shows that the use of IGRT can be successfully used in an accelerated partial breast intensity-modulated radiotherapy protocol. The authors believe that this technique has increased daily treatment accuracy and permitted reduction in the margin added to the clinical target volume to form the planning target volume.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Toxicity Analysis of Postoperative Image-Guided Intensity-Modulated Radiotherapy for Prostate Cancer

Purpose: To report on the acute and late gastrointestinal (GI) and genitourinary (GU) toxicity associated with a unique technique of image-guided radiotherapy (IGRT) in patients undergoing postprostatectomy irradiation. Methods and Materials: Fifty patients were treated with intensity-modulated radiation therapy (IMRT) after radical prostatectomy. Daily image guidance was performed to localize the prostate bed using kilovoltage imaging or cone-beam computed tomography. The median prescription dose was 68 Gy (range, 62-68 Gy). Toxicity was graded every 3 to 6 months according to the Common Terminology Criteria for Adverse Events version 3.0. Results: The median follow-up was 24 months (range, 13-38 months). Grade 2 acute GI and GU events occurred in 4 patients (8%) and 7 patients (14%), respectively. No Grade 3 or higher acute GI or GU toxicities were observed. Late Grade 2 GI and GU events occurred in 1 patient (2%) and 8 patients (16%), respectively. Only a single (2%) Grade 3 or higher late toxicity was observed. Conclusions: Image-guided IMRT in the postprostatectomy setting is associated with a low frequency of acute and late GI/GU toxicity. These results compare more favorably to radiotherapy techniques that do not use in-room image-guidance, suggesting that daily prostate bed localization may reduce the incidence of adverse events in patients undergoing postprostatectomy irradiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Local Response and Impact on Survival After Local Ablation of Liver Metastases From Colorectal Carcinoma by Computed Tomography-Guided High-Dose-Rate Brachytherapy

Purpose: To determine local tumor control after CT-guided brachytherapy at various dose levels and the prognostic impact of extensive cytoreduction in colorectal liver metastases. Methods and Materials: Seventy-three patients were treated on a single-center prospective trial that was initially designed to be randomized to three dose levels of 15 Gy, 20 Gy, or 25 Gy per lesion, delivered in a single fraction. However, because there was a high rate of cross-over of subjects from higher to lower dose levels, this study is better understood as a prospective trial with three dose levels. No upper size limit for the metastases was applied. We assessed time to local progression, progression-free survival, and overall survival. Results: According to safety constraints cross-over was performed. The final assignment was n = 98, n = 68, and n = 33 in the 15-Gy, 20-Gy, and 25-Gy groups, respectively. Median diameter of the largest tumor lesion in each patient was 5 cm (range, 1-13.5 cm). Estimated mean local recurrence-free survival for all lesions was 34 months (median not reached). The group assigned to 15 Gy after cross-over displayed 34 local recurrences out of 98 lesions; 20 Gy, 15 out of 68 lesions; 25 Gy, 1 out of 33 lesions. The difference between the 25-Gy and the 20-Gy or 15-Gy group was significant (p < 0.05). Repeated local tumor ablations were the most prominent factor for increased survival and dominated additional systemic antitumor treatments. Conclusions: Local tumor control after CT-guided brachytherapy of colorectal liver metastases demonstrated a strong dose dependency. The role of extensive minimally invasive tumor ablation in metastatic colorectal cancer needs to be further established.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Results of Image-Guided Deep Inspiration Breath Hold Breast Irradiation

Purpose: To evaluate the feasibility, cardiac dose reduction, and the influence of the setup error on the delivered dose for fluoroscopy-guided deep inspiration breath hold (DIBH) irradiation using a cone-beam CT for irradiation of left-sided breast cancer patients. Methods and Materials: Nineteen patients treated according to the DIBH protocol were evaluated regarding dose to the ipsilateral breast (or thoracic wall), heart, (left ventricle [LV]and left anterior descending artery [LAD]), and lung. The DIBH treatment plan was compared to the free-breathing (FB) treatment planning and to the dose data in which setup error was taken into account (i.e., actual delivered dose). Results: The largest setup variability was observed in the direction perpendicular to the RT field ({mu} = -0.8 mm, {Sigma} = 2.9 mm, {sigma} = 2.0 mm). The mean (D{sub mean}) and maximum (D{sub max}) doses of the DIBH treatment plan was significantly lower compared with the FB treatment plan for the heart (34% and 25%, p < 0.001), LV (71% and 28%, p < 0.001), and LAD (52% and 39.8%, p < 0.001). For some patients, large differences were observed between the heart D{sub max} according to the DIBH treatment plan and the actual delivered dose (up to 71%), although D{sub max} was always smaller than the planned FB dose (mean group reduction = 29%, p < 0.001). Conclusion: The image-guided DIBH treatment protocol is a feasible irradiation method with small setup variability that significantly reduces the dose to the heart, LV, and LAD.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Potentials and Limitations of Guiding Liver Stereotactic Body Radiation Therapy Set-Up on Liver-Implanted Fiducial Markers

Purpose: We investigated the potentials and limitations of guiding liver stereotactic body radiation therapy (SBRT) set-up on liver-implanted fiducial markers. Methods and Materials: Twelve patients undergoing compression-supported SBRT in a stereotactic body frame received fluoroscopy at treatment preparation and before each treatment fraction. In fluoroscopic videos we localized the markers and diaphragm tip at expiration and the spine (measurements on free-breathing and abdominal compression). Day-to-day displacements, rotations (markers only), and deformations were determined. Marker guidance was compared to conventional set-up strategies in treatment set-up simulations. Results: For compression, day-to-day motion of markers with respect to their centers of mass (COM) was {sigma} = 0.9 mm (random error SD), {Sigma} = 0.4 mm (systematic error SD), and <2.1 mm (maximum). Consequently, assuming that markers were closely surrounding spherical tumors, marker COM-guided set-up would have required safety margins of {approx}2 mm. Using marker COM as the gold standard, other set-up methods (using no correction, spine registration, and diaphragm tip craniocaudal registration) resulted in set-up errors of 1.4 mm < {sigma} < 2.8 mm, 2.6 mm < {Sigma} < 5.1 mm, and 6.3 mm < max < 12.4 mm. Day-to-day intermarker motion of <16.7%, 2.2% median, and rotations between 3.5{sup o} and 7.2{sup o} were observed. For markers not surrounding the tumor, e.g., 5 cm between respective COMs, these changes could effect residual tumor set-up errors up to 8.4 mm, 1.1 mm median (deformations), and 3.1 mm to 6.3 mm (rotations). Compression did not systematically contribute to deformations and rotations, since similar results were observed for free-breathing. Conclusions: If markers can be implanted near and around the tumor, residual set-up errors by marker guidance are small compared to those of conventional set-up methods, allowing high-precision tumor radiation set-up. However, substantial errors may result if markers are not implanted precisely, requiring further research to obtain adequate safety margins.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose-Volume Histogram Parameters and Late Side Effects in Magnetic Resonance Image-Guided Adaptive Cervical Cancer Brachytherapy

Purpose: To evaluate the predictive value of dose-volume histogram (DVH) parameters for late side effects of the rectum, sigmoid colon, and bladder in image-guided brachytherapy for cervix cancer patients. Methods and Materials: A total of 141 patients received external-beam radiotherapy and image-guided brachytherapy with or without chemotherapy. The DVH parameters for the most exposed 2, 1, and 0.1 cm{sup 3} (D{sub 2cc}, D{sub 1cc}, and D{sub 0.1cc}) of the rectum, sigmoid, and bladder, as well as International Commission on Radiation Units and Measurements point doses (D{sub ICRU}) were computed. Total doses were converted to equivalent doses in 2 Gy by applying the linear-quadratic model ({alpha}/{beta} = 3 Gy). Late side effects were prospectively assessed using the Late Effects in Normal Tissues-Subjective, Objective, Management and Analytic score. The following patient groups were defined: Group 1: no side effects (Grade 0); Group 2: side effects (Grade 1-4); Group 3: minor side effects (Grade 0-1); and Group 4: major side effects (Grade 2-4). Results: The median follow-up was 51 months. The overall 5-year actuarial side effect rates were 12% for rectum, 3% for sigmoid, and 23% for bladder. The mean total D{sub 2cc} were 65 {+-} 12 Gy for rectum, 62 {+-} 12 Gy for sigmoid, and 95 {+-} 22 Gy for bladder. For rectum, statistically significant differences were observed between Groups 1 and 2 in all DVH parameters and D{sub ICRU}. Between Groups 3 and 4, no difference was observed for D{sub 0.1cc.} For sigmoid, significant differences were observed for D{sub 2cc} and D{sub 1cc}, but not for D{sub 0.1cc} in all groups. For bladder, significant differences were observed for all DVH parameters only comparing Groups 3 and 4. No differences were observed for D{sub ICRU}. Conclusions: The parameters D{sub 2cc} and D{sub 1cc} have a good predictive value for rectal toxicity. For sigmoid, no prediction could be postulated because of limited data. In bladder, DVH parameters were predictive only for major toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High Dose-Per-Fraction Irradiation of Limited Lung Volumes Using an Image-Guided, Highly Focused Irradiator: Simulating Stereotactic Body Radiotherapy Regimens in a Small-Animal Model

Purpose: To investigate the underlying biology associated with stereotactic body radiotherapy (SBRT), both in vivo models and image-guided, highly focal irradiation systems are necessary. Here, we describe such an irradiation system and use it to examine normal tissue toxicity in a small-animal model at lung volumes similar to those associated with human therapy. Methods and Materials: High-dose radiation was delivered to a small volume of the left lung of C3H/HeJCr mice using a small-animal stereotactic irradiator. The irradiator has a collimation mechanism to produce focal radiation beams, an imaging subsystem consisting of a fluorescent screen coupled to a charge-coupled device camera, and a manual positioning stage. Histopathologic examination and micro-CT were used to evaluate the radiation response. Results: Focal obliteration of the alveoli by fibrous connective tissue, hyperplasia of the bronchiolar epithelium, and presence of a small number of inflammatory cells are the main reactions to low-volume/high-dose irradiation of the mouse lung. The tissue response suggested a radiation dose threshold for early phase fibrosis lying between 40 and 100 Gy. The irradiation system satisfied our requirements of high-dose-rate, small beam diameter, and precise localization and verification. Conclusions: We have established an experimental model and image-guided animal irradiation system for the study of high dose per fraction irradiations such as those used with SBRT at volumes analogous to those used in human beings. It will also allow the targeting of specific anatomical structures of the thorax or ultimately, orthotopic tumors of the lung.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Electromagnetic-Guided Dynamic Multileaf Collimator Tracking Enables Motion Management for Intensity-Modulated Arc Therapy

Purpose: Intensity-modulated arc therapy (IMAT) is attractive because of high-dose conformality and efficient delivery. However, managing intrafraction motion is challenging for IMAT. The purpose of this research was to develop and investigate electromagnetically guided dynamic multileaf collimator (DMLC) tracking as an enabling technology to treat moving targets during IMAT. Methods and Materials: A real-time three-dimensional DMLC-based target tracking system was developed and integrated with a linear accelerator. The DMLC tracking software inputs a real-time electromagnetically measured target position and the IMAT plan, and dynamically creates new leaf positions directed at the moving target. Low- and high-modulation IMAT plans were created for lung and prostate cancer cases. The IMAT plans were delivered to a three-axis motion platform programmed with measured patient motion. Dosimetric measurements were acquired by placing an ion chamber array on the moving platform. Measurements were acquired with tracking, without tracking (current clinical practice), and with the phantom in a static position (reference). Analysis of dose distribution differences from the static reference used a {gamma}-test. Results: On average, 1.6% of dose points for the lung plans and 1.2% of points for the prostate plans failed the 3-mm/3% {gamma}-test with tracking; without tracking, 34% and 14% (respectively) of points failed the {gamma}-test. The delivery time was the same with and without tracking. Conclusions: Electromagnetic-guided DMLC target tracking with IMAT has been investigated for the first time. Dose distributions to moving targets with DMLC tracking were significantly superior to those without tracking. There was no loss of treatment efficiency with DMLC tracking.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Long-Term Results of a Phase II Trial of Ultrasound-Guided Radioactive Implantation of the Prostate for Definitive Management of Localized Adenocarcinoma of the Prostate (RTOG 98-05)

Purpose: To evaluate the long-term effectiveness of transrectal ultrasound-guided permanent radioactive I{sup 125} implantation of the prostate for organ confined adenocarcinoma of the prostate compared with historical data of prostatectomy and external beam radiotherapy within a cooperative group setting. Methods and Materials: Patients accrued to this study had histologically confirmed, locally confined adenocarcinoma of the prostate clinical stage T1b, T1c, or T2a; no nodal or metastatic disease; prostate-specific antigen level of {<=}10 ng/ml; and a Gleason score of {<=}6. All patients underwent transrectal ultrasound-guided radioactive I{sup 125} seed implantation into the prostate. The prescribed dose was 145 Gy to the prostate planning target volume. Results: A total of 101 patients from 27 institutions were accrued to this protocol; by design, no single institution accrued more than 8 patients. There were 94 eligible patients. The median follow up was 8.1 years (range, 0.1-9.2 years). After 8 years, 8 patients had protocol-defined biochemical (prostate-specific antigen) failure (cumulative incidence, 8.0%); 5 patients had local failure (cumulative incidence, 5.5%); and 1 patient had distant failure (cumulative incidence, 1.1%; this patient also had biochemical failure and died of causes not related to prostate cancer). The 8-year overall survival rate was 88%. At last follow-up, no patient had died of prostate cancer or related toxicities. Three patients had maximum late toxicities of Grade 3, all of which were genitourinary. No Grade 4 or 5 toxicities were observed. Conclusions: The long-term results of this clinical trial have demonstrated that this kind of trial can be successfully completed through the RTOG and that results in terms of biochemical failure and toxicity compare very favorably with other brachytherapy published series as well as surgical and external beam radiotherapy series. In addition, the prospective, multicenter design highlights the probable generalizability of the outcomes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Image-Guided Radiotherapy (IGRT) for Prostate Cancer Comparing kV Imaging of Fiducial Markers With Cone Beam Computed Tomography (CBCT)

Purpose: To present our single-institution experience with image-guided radiotherapy comparing fiducial markers and cone-beam computed tomography (CBCT) for daily localization of prostate cancer. Methods and Materials: From April 2007 to October 2008, 36 patients with prostate cancer received intensity-modulated radiotherapy with daily localization by use of implanted fiducials. Orthogonal kilovoltage (kV) portal imaging preceded all 1244 treatments. Cone-beam computed tomography images were also obtained before 286 treatments (23%). Shifts in the anterior-posterior (AP), superior-inferior (SI), and left-right (LR) dimensions were made from kV fiducial imaging. Cone-beam computed tomography shifts based on soft tissues were recorded. Shifts were compared by use of Bland-Altman limits of agreement. Mean and standard deviation of absolute differences were also compared. A difference of 5 mm or less was acceptable. Subsets including start date, body mass index, and prostate size were analyzed. Results: Of 286 treatments, 81 (28%) resulted in a greater than 5.0-mm difference in one or more dimensions. Mean differences in the AP, SI, and LR dimensions were 3.4 {+-} 2.6 mm, 3.1 {+-} 2.7 mm, and 1.3 {+-} 1.6 mm, respectively. Most deviations occurred in the posterior (fiducials, 78%; CBCT, 59%), superior (79%, 61%), and left (57%, 63%) directions. Bland-Altman 95% confidence intervals were -4.0 to 9.3 mm for AP, -9.0 to 5.3 mm for SI, and -4.1 to 3.9 mm for LR. The percentages of shift agreements within {+-}5 mm were 72.4% for AP, 72.7% for SI, and 97.2% for LR. Correlation between imaging techniques was not altered by time, body mass index, or prostate size. Conclusions: Cone-beam computed tomography and kV fiducial imaging are similar; however, more than one-fourth of CBCT and kV shifts differed enough to affect target coverage. This was even more pronounced with smaller margins (3 mm). Fiducial imaging requires less daily physician input, is less time-consuming, and is our preferred method for prostate image-guided radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Magnetic Resonance Lymphography-Guided Selective High-Dose Lymph Node Irradiation in Prostate Cancer

Purpose: To demonstrate the feasibility of magnetic resonance lymphography (MRL) -guided delineation of a boost volume and an elective target volume for pelvic lymph node irradiation in patients with prostate cancer. The feasibility of irradiating these volumes with a high-dose boost to the MRL-positive lymph nodes in conjunction with irradiation of the prostate using intensity-modulated radiotherapy (IMRT) was also investigated. Methods and Materials: In 4 prostate cancer patients with a high risk of lymph node involvement but no enlarged lymph nodes on CT and/or MRI, MRL detected pathological lymph nodes in the pelvis. These lymph nodes were identified and delineated on a radiotherapy planning CT to create a boost volume. Based on the location of the MRL-positive lymph nodes, the standard elective pelvic target volume was individualized. An IMRT plan with a simultaneous integrated boost (SIB) was created with dose prescriptions of 42 Gy to the pelvic target volume, a boost to 60 Gy to the MRL-positive lymph nodes, and 72 Gy to the prostate. Results: All MRL-positive lymph nodes could be identified on the planning CT. This information could be used to delineate a boost volume and to individualize the pelvic target volume for elective irradiation. IMRT planning delivered highly acceptable radiotherapy plans with regard to the prescribed dose levels and the dose to the organs at risk (OARs). Conclusion: MRL can be used to select patients with limited lymph node involvement for pelvic radiotherapy. MRL-guided delineation of a boost volume and an elective pelvic target volume for selective high-dose lymph node irradiation with IMRT is feasible. Whether this approach will result in improved outcome for these patients needs to be investigated in further clinical studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Early Outcomes From Three Prospective Trials of Image-Guided Proton Therapy for Prostate Cancer

Purpose: To report early outcomes with image-guided proton therapy for prostate cancer. Methods and Materials: We accrued 211 prostate cancer patients on prospective Institutional Review Board-approved trials of 78 cobalt gray equivalent (CGE) in 39 fractions for low-risk disease, dose escalation from 78 to 82 CGE for intermediate-risk disease, and 78 CGE with concomitant docetaxel followed by androgen deprivation for high-risk disease. Minimum follow-up was 2 years. Results: One intermediate-risk patient and 2 high-risk patients had disease progression. Pretreatment genitourinary (GU) symptom management was required in 38% of patients. A cumulative 88 (42%) patients required posttreatment GU symptom management. Four transient Grade 3 GU toxicities occurred, all among patients requiring pretreatment GU symptom management. Multivariate analysis showed correlation between posttreatment GU 2+ symptoms and pretreatment GU symptom management (p < 0.0001) and age (p = 0.0048). Only 1 Grade 3+ gastrointestinal (GI) symptom occurred. The prevalence of Grade 2+ GI symptoms was 0 (0%), 10 (5%), 12 (6%), and 8 (4%) at 6, 12, 18, and 24 months, with a cumulative incidence of 20 (10%) patients at 2 years after proton therapy. Univariate and multivariate analyses showed significant correlation between Grade 2+ rectal bleeding and proctitis and the percentage of rectal wall (rectum) receiving doses ranging from 40 CGE (10 CGE) to 80 CGE. Conclusions: Early outcomes with image-guided proton therapy suggest high efficacy and minimal toxicity with only 1.9% Grade 3 GU symptoms and <0.5% Grade 3 GI toxicities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗