Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “grid integration study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

A conservative phase-space moving-grid strategy for a 1D-2V Vlasov–Fokker–Planck Solver

In this work, we develop a conservative configuration- and velocity-space (i.e., phase-space) moving-grid strategy for the Vlasov–Fokker–Planck (VFP) equation in a planar geometry. The velocity-space grid is normalized and shifted in terms of the thermal speed and the bulk-fluid velocity, respectively. The configuration-space grid is moved according to a mesh-motion-partial-differential equation (MMPDE), which equidistributes a monitor function that is inversely proportional to the gradient-length scales of the macroscopic plasma quantities. The resulting inertial terms in the transformed VFP equations are discretized to ensure the discrete conservation of mass, momentum, and energy. To satisfy the discrete conservation theorems in the presence of phase-space mesh motion, we employ the method of discrete nonlinear constraints – explored in previous studies – but the underlying symmetries are determined in a much more efficient manner than before. The conservative grid-adaptivity strategy provides an efficient scheme that resolves important physical structures in the phase-space while controlling the computational complexity at all times. We demonstrate the favorable features of the proposed algorithm through a set of test cases of increasing complexity. The problems test independent components of the algorithms, as well as the integrated capability on settings relevant to inertial confinement fusion.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Integrate Latimer Controls' Solution into RTAC (CRADA Final Report, CRD-23-24672)

Latimer Controls, Inc. was awarded two vouchers under the Department of Energy's American-Made Solar Prize Round 6 to conduct collaborative research at a national laboratory. The National Renewable Energy Laboratory (NREL) was selected as a partner to assist Latimer Controls in the performance evaluation of its photovoltaic (PV) control software. This collaboration focuses on developing a hardware-in-the-loop (HIL) testbed at NREL, which will be used to test and validate the Latimer PV control technology in a realistic yet de-risked environment. Both Latimer and NREL teams will work together to analyze the collected test data, derive insights, and disseminate the scientific findings. Recent studies underscore the potential of solar energy as a zero-marginal-cost and zero-emission flexibility resource within the bulk power system, particularly when integrated with advanced control systems. To enhance the performance of such systems, Latimer Controls has developed leading-edge technologies, including machine learning (ML) algorithms and hierarchical inverter set-point allocation methods. These innovations are designed to estimate the operational headroom of large PV plants for grid integration and control. However, comprehensive validation under real-world conditions remains necessary. To address this gap, the concurrent CRADA project proposes the real-world application and validation of the Latimer Control solution within a HIL environment. Initially, the Latimer algorithm was developed and tested within MATLAB Simulink, a platform suitable for research-level simulations and iterative development. However, transitioning this technology to a real solar site as an industry-ready solution necessitates implementation in a format compatible with widely used solar power plant controllers. In this additional CRADA work, the MATLAB Simulink-based logic will be translated into Structured Text, a programming language compliant with IEC 61131 standards, which is commonly used for custom logic implementations in industry-leading programmable logic controllers (PLCs), such as the Schweitzer SEL real-time automation controller (RTAC). This transition will facilitate the deployment of the Latimer Control solution in real-world solar power plants, thereby advancing the technology towards commercialization.

14 SOLAR ENERGY↗

Modeling of Non-Spherical Droplet Dynamics

A two-dimensional time-dependent computer code based on the modified Arbitrary Lagrangian Eulerian (ALE) technique, has been developed to simulate non-spherical droplet dynamics and evaporation under convective flows at real rocket combustion chamber conditions. The equations of mass, momentum, energy and species are simultaneously solved for both liquid and gas phases with an accurate dynamic interface tracking. The jump boundary conditions across the deforming droplet surface are obtained by applying the integral forms of conservation of mass, momentum, and energy. At each time step, the interface geometry and flow properties at the droplet surface are implicitly solved by satisfying the interface boundary conditions. A Lagrangian technique was developed to track the arbitrarily moving interface between the liquid droplet and the external gas. An elliptic grid generator is adopted to dynamically reconstruct grids both inside and outside the droplet surface. This code has been used to study droplet oscillation, droplet deformation/breakup, nonspherical droplet evaporation in both low and high pressure convective flows. This presentation briefly describes the numerical algorithm for modeling of the nonspherical droplet dynamics and demonstrates the representative simulation results of nonspherical droplet evaporation at low and high pressure convective flows. Potential applications of this code to rocket combustor design and performance predictions are discussed.

Deng, Zheng-Tao↗

Exploring the interplay between distributed wind generators and solar photovoltaic systems

This study investigates the spatial and temporal dynamics of wind and solar energy generation across the continental United States, focusing on energy availability, reliability, variability, and cooperation. Using data from the National Renewable Energy Laboratory, we analyze the performance of wind turbines and photovoltaic systems, revealing distinct patterns in energy production and reliability. The classification of wind and solar zones based on energy availability and reliability provides valuable insights for renewable energy planning and grid integration strategies. Overall, this methodology contributes to understanding wind and solar interactions, which will lead to informing effective renewable energy deployment and grid integration efforts.

14 SOLAR ENERGY↗

Assessment of Electric Grid Transmission System Simulator for Human Factors Research

Over the past decades, various technologies have been developed for electric grid operations to support clean energy, meet rising electricity demands, and address infrastructure concerns. However, the human factors aspect is often overlooked during rapid integration. Questions persist about how these technologies impact human performance. Simulators play a critical role in supporting investigation of human factors design concepts and conducting comprehensive usability testing to evaluate human performance and assess human reliability. This paper aims to address human factors research simulator requirements and conduct a comparative study of six different simulators. A detailed evaluation reveals that the evaluated simulators lack the ability to customize user interfaces. Additionally, their user interface designs do not fulfill the basic human factors design principles, potentially leading to increased response variability and reduced statistical power when conducting controlled experimental research. In the future, it is essential to develop scripting tools to integrate customizable user interfaces and simulation models, ensuring meeting research requirements.

Li, Ruixuan↗

An Overview of Issues Related to IEEE Std 1547-2018 Requirements Regarding Voltage and Reactive Power Control

The revised Institute of Electrical and Electronics Engineers (IEEE) 1547 Standard for Interconnection and Interoperability of Distributed Energy Resources with Associated Electric Power Systems Interfaces (IEEE Std 1547-2018) was published in April 2018. This standard is one of the foundational documents in the United States needed for integrating distributed energy resources (DERs), including solar energy systems, with the electric distribution grid. The revised standard contains 11 chapters (clauses) and 8 annexes that comprise 136 pages. The revision is significantly different from the 2003 version, and it contains new concepts and new technical requirements. Each clause specifies information or requirements that apply to certain aspects important to the interconnection of DERs to the electric power system. Implementing the requirements necessitates a careful study of the underlying technical concept and requires the appropriate information required to calculate relevant settings and configurations. Various stakeholders have different roles in implementing the standard, and portions of the standard are directed toward a specific audience who must possess specialized information and technical training to use and apply the requirements. This document aims to (1) summarize a specific portion of the standard as concisely as possible and (2) provide the reader with introductory knowledge and information to support the utilization of the requirements.

14 SOLAR ENERGY↗

Asynchronous Truncated Multigrid-Reduction-in-Time

In this paper, we present the new “asynchronous truncated multigrid-reduction-in-time” (AT-MGRIT) algorithm for introducing time parallelism to the solution of discretized time-dependent problems. The new algorithm is based on the multigrid-reduction-in-time (MGRIT) approach, which, in certain settings, is equivalent to another common multilevel parallel-in-time method, Parareal. In contrast to Parareal and MGRIT that both consider a global temporal grid over the entire time interval on the coarsest level, the AT-MGRIT algorithm uses truncated local time grids on the coarsest level, each grid covering certain temporal subintervals. Further, these local grids can be solved completely in an independent way from each other, which reduces the sequential part of the algorithm and, thus, increases parallelism in the method. Here, we study the effect of using truncated local coarse grids on the convergence of the algorithm, both theoretically and numerically, and show, using challenging nonlinear problems, that the new algorithm consistently outperforms classical Parareal/MGRIT in terms of time to solution.

97 MATHEMATICS AND COMPUTING↗

National Reactor Innovation Center (NRIC) Grid Connection Roadmap (Rev. 1)

In an effort to define the roadmap for establishing the necessary electrical infrastructure at the Idaho National Laboratory to fully support connection of NRIC reactors, this roadmap serves to identify the current forecasted reactors planned for installation at INL and provide a consolidated list of the identified infrastructure improvements that will be necessary to support testing of NRIC reactors. Additionally, the roadmap will leverage this information to establish an integrated timeline to support detailed planning and execution of system improvements. To drive this planning, requirements, as derived from authoritative sources, will be identified. A clear definition of impacted stakeholders will be established, as well as a list of risks that will need to be managed as the program moves forward.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Observing system simulation experiments related to space-borne Lidar wind profiling. Part 1: Forecast impacts of highly idealized observing systems

Simulation experiments comparing the relative importance of an idealized LIDAR wind profiling system with idealized temperature and pressure sounding systems on 12 h forecasts are studied for three "nature' fields representing the true evolving atmospheric states. The three fields are obtained respectively from: (1) a long integration of the GLAS 4th Order Model (4 deg lat x 5 deg lon x 9 levels), (2) a continuous sequence of NMC operational analysis and, (3) a long integration of the ECMWF high resolution (1.875 deg 1 lat x 1.875 deg lon x 15 layers) operational forecast model. These fields are interpolated to the grid of the GLAS model and used for simulating the observed global analysed fields of winds, temperature, moisture and surface pressure. The same interpolated fields are also used for verification of forecast impact. The effects of clouds, aerosol concentrations, and instrument accuracies on the simulated observation will be discussed.

Halem, M.↗

Evaluating the design of satellite scanning radiometers for earth radiation budget measurements with system simulations. Part 1: Instantaneous estimates

A set of system simulations was performed to evaluate candidate scanner configurations to fly as a part of the Earth Radiation Budget Instrument (ERBI) on the polar platforms during the 1990's. The simulation is considered of instantaneous sampling (without diurnal averaging) of the longwave and shortwave fluxes at the top of the atmosphere (TOA). After measurement and subsequent inversion to the TOA, the measured fluxes were compared to the reference fluxes for 2.5 deg lat/long resolution targets. The reference fluxes at this resolution are obtained by integrating over the 25 x 25 = 625 grid elements in each target. The differences between each of these two resultant spatially averaged sets of target measurements (errors) are taken and then statistically summarized. Five instruments are considered: (1) the Conically Scanning Radiometer (CSR); (2) the ERBE Cross Track Scanner; (3) the Nimbus-7 Biaxial Scanner; (4) the Clouds and Earth's Radiant Energy System Instrument (CERES-1); and (5) the Active Cavity Array (ACA). Identical studies of instantaneous error were completed for many days, two seasons, and several satellite equator crossing longitudes. The longwave flux errors were found to have the same space and time characteristics as for the shortwave fluxes, but the errors are only about 25 pct. of the shortwave errors.

Stowe, Larry↗

Concept report: Experimental vector magnetograph (EXVM) operational configuration balloon flight assembly

The observational limitations of earth bound solar studies has prompted a great deal of interest in recent months in being able to gain new scientific perspectives through, what should prove to be, relatively low cost flight of the magnetograph system. The ground work done by TBE for the solar balloon missions (originally planned for SOUP and GRID) as well as the rather advanced state of assembly of the EXVM has allowed the quick formulation of a mission concept for the 30 cm system currently being assembled. The flight system operational configuration will be discussed as it is proposed for short duration flight (on the order of one day) over the continental United States. Balloon hardware design requirements used in formulation of the concept are those set by the National Science Balloon Facility (NSBF), the support agency under NASA contract for flight services. The concept assumes that the flight hardware assembly would come together from three development sources: the scientific investigator package, the integration contractor package, and the NSBF support system. The majority of these three separate packages can be independently developed; however, the computer control interfaces and telemetry links would require extensive preplanning and coordination. A special section of this study deals with definition of a dedicated telemetry link to be provided by the integration contractor for video image data for pointing system performance verification. In this study the approach has been to capitalize to the maximum extent possible on existing hardware and system design. This is the most prudent step that can be taken to reduce eventual program cost for long duration flights. By fielding the existing EXVM as quickly as possible, experience could be gained from several short duration flight tests before it became necessary to commit to major upgrades for long duration flights of this system or of the larger 60 cm version being considered for eventual development.

Source record↗

Hawaii Threat Brief

The Digital Energy Transformation is redefining how power systems operate, integrating physical infrastructure with digital technologies to enhance efficiency, visibility, and resilience. For islanded and digitally modernizing systems like Hawai‘i’s, this shift presents both new opportunities and evolving challenges in cybersecurity, supply chain assurance, and environmental resilience. This brief provides an overview of critical infrastructure dependencies and systemic risks associated with increasing digital integration. It summarizes recent energy-sector threat activity and case studies that illustrate adversary tactics and supply chain vulnerabilities, and identifies pathways to strengthen resilience.

25 - ENERGY STORAGE↗

CFD-Based Design Optimization Tool Developed for Subsonic Inlet

The traditional approach to the design of engine inlets for commercial transport aircraft is a tedious process that ends with a less-than-optimum design. With the advent of high-speed computers and the availability of more accurate and reliable computational fluid dynamics (CFD) solvers, numerical optimization processes can effectively be used to design an aerodynamic inlet lip that enhances engine performance. The designers' experience at Boeing Corporation showed that for a peak Mach number on the inlet surface beyond some upper limit, the performance of the engine degrades excessively. Thus, our objective was to optimize efficiency (minimize the peak Mach number) at maximum cruise without compromising performance at other operating conditions. Using a CFD code NPARC, the NASA Lewis Research Center, in collaboration with Boeing, developed an integrated procedure at Lewis to find the optimum shape of a subsonic inlet lip and a numerical optimization code, ADS. We used a GRAPE-based three-dimensional grid generator to help automate the optimization procedure. The inlet lip shape at the crown and the keel was described as a superellipse, and the superellipse exponents and radii ratios were considered as design variables. Three operating conditions: cruise, takeoff, and rolling takeoff, were considered in this study. Three-dimensional Euler computations were carried out to obtain the flow field. At the initial design, the peak Mach numbers for maximum cruise, takeoff, and rolling takeoff conditions were 0.88, 1.772, and 1.61, respectively. The acceptable upper limits on the takeoff and rolling takeoff Mach numbers were 1.55 and 1.45. Since the initial design provided by Boeing was found to be optimum with respect to the maximum cruise condition, the sum of the peak Mach numbers at takeoff and rolling takeoff were minimized in the current study while the maximum cruise Mach number was constrained to be close to that at the existing design. With this objective, the optimum design satisfied the upper limits at takeoff and rolling takeoff while retaining the desirable cruise performance. Further studies are being conducted to include static and cross-wind operating conditions in the design optimization procedure. This work was carried out in collaboration with Dr. E.S. Reddy of NYMA, Inc.

Source record↗

Performance evaluation of a dynamic wall integrated with active insulation and thermal energy storage systems

Thermal energy storage systems in buildings can store cooling/heating energy during non-peak load hours or when renewable energy sources are available for later use when demanded. Using the building envelope as a thermal battery can help to shave the peak load, reduce the burden in electric grids, and enhance the occupant's thermal comfort. Sensible energy storage on wall systems such as thermally activated building systems can provide an active thermal storage strategy. However, most of the stored energy is used through passive means directed by the thermal lag, which can impede the on-demand release of the stored energy. Integrating active insulation systems with building thermal storage systems can increase the flexibility of charging and discharging time and duration. In this study, a wall system equipped with an active insulation system and thermally activated storage system was designed, and its performance on active cooling energy contribution was studied. The performances of energy storage (charging), release (discharging) of the thermal energy storage energy, and the active insulation system were studied separately and together as an integrated system. Results showed that the thermal properties of the thermal energy storage core material and the pipe spacing of both embedded pipes in the thermal energy storage and hydronic pipes used in the active insulation system affected the wall performance the most out of all the tested wall system parameters. During discharging, the heat flux into the wall was as high as 81.92 W/m 2 . This active insulation system's dynamic R-value varied between less than 1ft 2 •°F•h/BTU (0.18 m 2 •K/W) to 98% of the equally thick foam insulation's R-value.

25 ENERGY STORAGE↗

Optimal Economic Dispatch and Load-Following Strategies for Nuclear Integrated Energy Systems

The need for distributed and adaptable energy resources that can handle the growing unpredictability in both supply and demand is rising as the power system continues to modernize. In order to satisfy those needs and maintain grid resilience, nuclear power plants can dynamically control their output, despite typically being used as baseload generators. By incorporating energy storage and renewable energy sources, nuclear integrated energy systems are designed to satisfy the electrical and thermal demands of different end-user applications while ensuring flexible power operation. These systems generate revenue by participating in both wholesale and ancillary services electricity markets, as well as commodity markets for various byproducts generated from coupled industrial processes. This study addresses the economic dispatch efficiency of a tightly coupled nuclear integrated energy system comprising a gigawatt-scale light water reactor, commercialized in the U.S., a high-temperature steam electrolysis unit, a district heating network, and specified electrical loads. To demonstrate the nuclear power plant’s flexibility within the day-ahead unit commitment and economic dispatch framework, while maintaining equilibrium even during periods of refueling outages, this paper develops a mixed-integer linear programming framework that models the subsystems and components of its nuclear steam supply system. A systematic comparative analysis of flexible versus baseload nuclear power plant operation under varying levels of renewable energy integration indicates that flexible operation enhances system profitability by more than 18% while also increasing energy storage utilization, improving reactor responsiveness to load fluctuations, and allowing for greater participation across numerous electricity markets.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

On the Accuracy of CFD-Based Pressure Drop Predictions for Right-Angle Ducts

The predictive capability of computational fluid dynamics (CFD) codes for turbulent flow through curved ducts is of significant importance to the design and performance analysis of modern rocket engine flowpaths. Code calibration and validation studies for this class of flow are desireable to estimate the performance margin and operating range of components designed using Navier-Stokes methods. Parametric experimental studies such as that of Weske (NACA ARR W-39) provided a wealth of performance data for the design of single- and compound elbow configurations with various cross-sections, curvature and aspect ratios at varying Reynolds numbers. In that work, the majority of data is presented in the form of loss coefficients, characterizing pressure losses due to duct curvature, and including losses due to wall friction. Using measured friction coefficients, losses of equivalent straight lengths of duct are subtracted, resulting in performance curves useful for design computations. These data are currently used in a CFD-based parametric study covering a broad range of operating conditions. Of particular interest for the accuracy of CFD predictions are the effects on pressure loss due to inlet boundary layer thickness (dependent on upstream development length), and the wall treatment for the turbulence equations (conventional wall functions vs. wall integration using a two-layer model). The experimental data are reassessed in the form of an error analysis, and are compared with CFD predictions for 18 computational cases. Grid-independence, grid spacing, and convergence requirements of the cases are discussed. Conclusions regarding the relative importance of the parametric variables will be presented.

Brankovic, Andreja↗

Consistency Between Divergent Circulations from Reanalysis Data Sets and Satellite-Derived Precipitation, Radiation, and Surface Fluxes

Large-scale divergent circulations are part of the atmospheric dynamic response to diabatic heating from condensation, radiative processes, and surface heat fluxes. Vertical motion and the associated divergent wind is thus intimately tied to the hydrologic cycle and the global heat balance. Despite its importance, the divergent circulation is too small in comparison to the rotational flow to measure directly with any accuracy. Vertical motions are recovered diagnostically from reanalyses and, as such, are subject to shortcomings in model physics, numerics, and data availability. We use several GEWEX pre-EOS data sets derived from satellite data to assess interannual divergent flow anomalies in the NCEP, GSFC, and GSFC DAO analyse. Among the data sets are monthly, 2.5 degree gridded precipitation (MSU and SSM/I-based), TOA radiative fluxes from ERBS, surface radiative fluxes from the SRB project, and surface latent and sensible flux estimates from SSM/I. Most of these data sets can be considered as independent of the reanalysis fields. We focus largely on the period 1987-1989 encompassing a strong El Nino / la Nina couplet. Consequently we emphasize interannual changes rather than climatological aspects of the reanalyses. In the processes of this study we use simple integral constraints enforced through the satellite-derived data sets to derive corrections to the divergent circulation produced from the reanalyses. We examine the implications of these corrections in describing how perturbations to the tropical heat balance evolve during a warm / cool couplet. In particular the perturbations to the planetary scale water vapor transport, and the resulting changes in TOA and surface radiative fluxes are considered.

Robertson, Franklin R.↗

Social vulnerability and power loss mitigation: A case study of Puerto Rico

The increasing occurrence of extreme weather events urges us to reevaluate the resiliency and vulnerability aspects of our most critical infrastructures — such as power grids — as their failures result in both economic loss and severe human hardship. Seen through the lens of alleviating human suffering, it is crucial to be able to identify critical system components of the infrastructure for targeted hardening given resource constraints. This effort is of particular importance in islanded areas such as Puerto Rico where hurricanes are frequent and resources are limited, and where the spatially diverse effects of power loss on human suffering are all the more severe. Recent studies on evaluating infrastructure networks during extreme weather events have taken a simulation based approach that incorporates a variety of component models, such as weather realizations, topological network models, fragility models, and power flow models to estimate expected loss of service. Here, in this work, we expand such a Component Based Event Simulation (CBES) methodology proposed in the literature and integrate it with a social vulnerability modeling component. This paradigm-advancing approach of synthesizing the cutting edge capability of power network modeling and the social impacts of the power transmission network failure is demonstrated for the island of Puerto Rico. Our work exemplifies the efficacy of this integrated modeling framework in developing a decision metric for targeted transmission line hardening.

24 POWER TRANSMISSION AND DISTRIBUTION↗