Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “green power”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

The Majorana Demonstrator readout electronics system

The M AJORANA D EMONSTRATOR comprises two arrays of high-purity germanium detectors constructed to search for neutrinoless double-beta decay in 76 Ge and other physics beyond the Standard Model. Its readout electronics were designed to have low electronic noise, and radioactive backgrounds were minimized by using low-mass components and low-radioactivity materials near the detectors. This paper provides a description of all components of the M AJORANA D EMONSTRATOR readout electronics, spanning the front-end electronics and internal cabling, back-end electronics, digitizer, and power supplies, along with the grounding scheme. The spectroscopic performance achieved with these readout electronics is also demonstrated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Stress Tuning of Laser Crystals

The topic of stress tunable laser crystals is addressed in this study with the purpose of determining the piezo-optic coefficients of a new laser material. This data was collected using a quadruple pass birefringence technique because of its high degree of sensitivity relative to the other methods examined including fringe shift analysis using a Mach-Zender interferometer. A green He-Ne laser was passed through a light chopper and Glan-Thompson prism before entering a crystal of Erbium doped Yttrium Aluminum Garnet (Er:YAG) (used in order to validate the experimental technique). The Er:YAG crystal is mounted in a press mechanism and the laser is quadruple passed through test specimen before being returned through the prism and the orthogonally polarized portion of the beam measured with a optical sensor. At a later stage, the Er:YAG crystal was replaced with a new crystal in order to determine the piezo-optic coefficients of this uncharacterized material. The applied load was monitored with the use of a 50 lb. load cell placed in line with the press. Light transmission readings were taken using a lock-in amplifier while load cell measurements were taken with a voltmeter from a 5 volt, 0.5 amp power supply. Despite the fact that an effective crystal press damping system was developed, size limitations precluded the use of the complete system. For this reason, data points were taken only once per full turn so as to minimize the effect of non uniform load application on the collected data. Good correlation was found in the transmission data between the experimentally determined Er:YAG and the previously known peizo-optic constants of non-doped crystal with which it was compared. The variation which was found between the two could be accounted for by the aforementioned presence of Erbium in the experimental sample (for which exact empirical data was not known). The same test procedure was then carried out on a Yttrium Gallium Aluminum garnet (YGAG) for the purpose of establishing values of its unknown piezo-optic constant tensor using experimentally collected transmission data. Significant variation between the piezo-optic constants of YAG and YGAG crystals was found however, the excellent data correlation of separate experimental runs carried out on the YGAG sample demonstrates the validity of these results. The data collected during the stressing of the YGAG was of high quality, however the amount of data collected was somewhat limited by a fracture of YGAG specimen which undoubted altered the crystalline lattice structure and hence precluded any further testing.

Carty, Atherton A.↗

A radiation - tolerant, low - power non - volatile memory based on silicon nanocrystal quantum dots.

Nanocrystal nonvolatile floating-gate memories are a good candidate for space applications - initial results suggest they are fast, more reliable and consume less power than conventional floating gate memories. In the nanocrystal based NVM device, charge is not stored on a continuous polysilicon layer (so-called floating gate), but instead on a layer of discrete nanocrystals. Charge injection and storage in dense arrays of silicon nanocrystals in Si02 is a critical aspect of the performance of potential nanocrystal flash memory structures. The ultimate goal for this class of devices is few- or single-electron storage in a small number of nanocrystal elements. In addition, the nanocrystal layer fabrication technique should be simple, 8-inch wafer compatible and well controlled.

Green, M. L.↗

Advanced Design for the WIQ Magnet With Steering Corrector Function

The Facility for Rare Isotopes Beams (FRIB) delivers heavy-ion primary beams at energies of up to 300 MeV/u at 10 kW of beam power to generate rare isotope beams for experiments and will eventually operate at beam power of 400 kW. The preseprator of the Advanced Rare Isotope Separator (ARIS) is equipped with six warm-iron quadrupole (WIQ) singlets and two dipoles integrated right after the production target. They have a compact structure and operate in a high radiation vacuum environment within a hot cell having remote handling capabilities for installation and maintenance. Due to asymmetry with respect to the quadrupole poles, nested sextupole excitations in WIQs induce vertical dipoles that offset the centroid trajectory; Magnet misalignments also result in trajectory offsets. Such offsets degrade separator performance but can be minimized by changing the current distribution on sextupole and octupole coils. In this work, we show how modifications to the WIQ coil design can allow superimposed dipole fields to be included to the octupole and sextupole windings, as well as addition of dipole components by splitting coil currents over groups with separator power supplies. Adjusting the group currents can cancel the sextupole-induced vertical dipole component which can be as high as 0.012 Tm. Octupole coil changes may superimpose a horizontal dipole integrated strength as high as 0.0332 Tm. Unwanted higher harmonics induced as a side effect of the new design are kept to a minimum such that separator performance is preserved as much as possible.

Accelerator magnets↗

Characterization of kerogen nanopores using 2D NMR relaxation and MD simulations

The characterization of kerogen nanopores is crucial for predicting the geostorage capacity and recoverability of natural gas in unconventional gas shale reservoirs. Towards this end, a powerful technique is presented which integrates 2D NMR T 1 -T 2 relaxation measurements with molecular dynamics (MD) simulations of hydrocarbons confined in the nanopores of kerogen. The integrated NMR-MD technique is demonstrated using T 1 -T 2 measurements of kerogen isolates and organic-rich chalks saturated with heptane, together with MD simulations of heptane completely dissolved in a realistic kerogen model. The NMR-MD results are used to extract the swelling ratio and nanopore size distribution of kerogen as a function of depth in the reservoir. The effects of organic nanoconfinement on the T 1 relaxation dispersion and T 2 residual dipolar coupling of heptane are investigated, as well as the effect of downhole effective stress on the kerogen nanopore size as a function of depth and compaction. Potential applications in partially depleted gas shale reservoirs are discussed, including CO 2 utilization/geostorage, geostorage of green H 2 , and integration of the NMR-MD technique with thermodynamic models for predicting the competitive sorption of gas mixtures in kerogen.

Compaction↗

Surprises from a Deep ASCA Spectrum of the Broad Absorption Line Quasar PHL 5200

We present a deep (approx. 85 ks) ASCA observation of the prototype broad absorption line quasar (BALQSO) PHL 5200. This is the best X-ray spectrum of a BALQSO yet. We find the following: (1) The source is not intrinsically X-ray weak. (2) The line-of-sight absorption is very strong, with N(sub H) = 5 x 10(exp 23)/sq cm. (3) The absorber does not cover the source completely; the covering fraction is approx. 90%. This is consistent with the large optical polarization observed in this source, implying multiple lines of sight. The most surprising result of this observation is that (4) the spectrum of this BALQSO is not exactly similar to other radio-quiet quasars. The hard X-ray spectrum of PHL 5200 is steep, with the power-law spectral index alpha approx. 1.5. This is similar to the steepest hard X-ray slopes observed so far. At low redshifts, such steep slopes are observed in narrow-line Seyfert 1 (NLS1) galaxies, believed to be accreting at a high Eddington rate. This observation strengthens the analogy between BALQSOs and NLS1 galaxies and supports the hypothesis that BALQSOs represent an early evolutionary state of quasars. It is well accepted that the orientation to the line of sight determines the appearance of a quasar: age seems to play a significant role as well.

Mathur, Smita↗

Total ozone determination by spectroradiometry in the middle ultraviolet

A method has been developed to determine total ozone from multispectral measurements of the direct solar irradiance. The total ozone is determined by a least squares fit to the spectrum between 290 nm and 380 nm. The aerosol extinction is accounted for by expanding it in a power series in wavelength; use of the linear term proved adequate. A mobile laboratory incorporating a sky scanner has been developed and used to obtain data to verify the method. Sun tracking, wavelength setting of the double monochromator, and data acquisition are under control of a minicomputer. Results obtained at Wallops Island, Virginia, and Palestine, Texas, agree well with simultaneous Dobson and Canterbury spectrometer and balloon ECC ozonesonde values. The wavelength calibration of the monochromator and the values for the normalized ozone absorption are the most important factors in an accurate determination of total ozone.

Garrison, L. M.↗

Fed-batch production of deuterated protein in Escherichia coli for neutron scattering experimentation

Neutron scattering is a powerful technique for determining the structure and dynamics of biological materials in a variety of environmental conditions. A distinguishing property of the neutron is its sensitivity to detecting hydrogen and distinguishing it from its isotope deuterium. This enables unique types of experiments that take advantage of this differential sensitivity called isotopic contrast variation. Using this approach, the chemistry of the system is not changed, but the visibility of individual sample components can be tuned by varying the deuterium content of the system under investigation. Deuterated proteins are commonly produced in bacterial systems that are adapted to growth in D2O minimal media. To maximize the yield of deuterium-labeled protein and efficiently utilize D2O and occasionally the deuterated substrate, fed-batch processes are routinely used to maximize biomass production without compromising cell viability. A step-by-step procedure will be described along with a case study of the production of deuterated green fluorescent protein. Limitations of the process will also be discussed.

Weiss, Kevin L.↗

Comet 81p/Wild 2: The Updated Stardust Coma Dust Fluence Measurement for Smaller (Sub 10-Micrometre) Particles

Micrometre and smaller scale dust within cometary comae can be observed by telescopic remote sensing spectroscopy [1] and the particle size and abundance can be measured by in situ spacecraft impact detectors [2]. Initial interpretation of the samples returned from comet 81P/Wild 2 by the Stardust spacecraft [3] appears to show that very fine dust contributes not only a small fraction of the solid mass, but is also relatively sparse [4], with a low negative power function describing grain size distribution, contrasting with an apparent abundance indicated by the on-board Dust Flux Monitor Instrument (DFMI) [5] operational during the encounter. For particles above 10 m diameter there is good correspondence between results from the DFMI and the particle size inferred from experimental calibration [6] of measured aerogel track and aluminium foil crater dimensions (as seen in Figure 4 of [4]). However, divergence between data-sets becomes apparent at smaller sizes, especially submicrometre, where the returned sample data are based upon location and measurement of tiny craters found by electron microscopy of Al foils. Here effects of detection efficiency tail-off at each search magnification can be seen in the down-scale flattening of each scale component, but are reliably compensated by sensible extrapolation between segments. There is also no evidence of malfunction in the operation of DFMI during passage through the coma (S. Green, personal comm.), so can the two data sets be reconciled?

Price, M. C.↗

MUSTANG: A Workhorse for NASA Spaceflight Avionics

The Modular Unified Space Technology Avionics for Next Generation (MUSTANG) is a small integrated Avionics system including Command and Data Handling (C&DH), Power System Electronics (PSE), Attitude Control System Interfaces (ACS), and Propulsion Electronics. The MUSTANG Avionics Architecture is built upon many years of knowledge capture and lessons learned at the Goddard Space Flight Center. With a motivation towards modularity and keeping board redesign costs to a minimum, MUSTANG offers flexibility in features with a backplane-less design and allows the user to choose the options (cards) needed for their system. It incorporates a distributed power system that provides secondary power to all its subcomponents reducing the number of primary services needed for an Avionics. MUSTANG can be integrated into one system or divided into several smaller components. MUSTANG supports redundancy and cross-strap ability for a more robust and reliable Avionics system. A variation of MUSTANG exists for Instrument Electronics called iMUSTANG and allows the user to select functionality applicable to the instrument electronics. MUSTANG is not meant to replace Avionics for all spacecraft. There are limitations due to its relatively compact size, but the MUSTANG design has proven broadly applicable on many spacecraft and instrument bus avionics architectures.

MUSTANG↗

Simultaneous Spectral Temporal Adaptive Raman Spectrometer - SSTARS

Raman spectroscopy is a prime candidate for the next generation of planetary instruments, as it addresses the primary goal of mineralogical analysis, which is structure and composition. However, large fluorescence return from many mineral samples under visible light excitation can render Raman spectra unattainable. Using the described approach, Raman and fluorescence, which occur on different time scales, can be simultaneously obtained from mineral samples using a compact instrument in a planetary environment. This new approach is taken based on the use of time-resolved spectroscopy for removing the fluorescence background from Raman spectra in the laboratory. In the SSTARS instrument, a visible excitation source (a green, pulsed laser) is used to generate Raman and fluorescence signals in a mineral sample. A spectral notch filter eliminates the directly reflected beam. A grating then disperses the signal spectrally, and a streak camera provides temporal resolution. The output of the streak camera is imaged on the CCD (charge-coupled device), and the data are read out electronically. By adjusting the sweep speed of the streak camera, anywhere from picoseconds to milliseconds, it is possible to resolve Raman spectra from numerous fluorescence spectra in the same sample. The key features of SSTARS include a compact streak tube capable of picosecond time resolution for collection of simultaneous spectral and temporal information, adaptive streak tube electronics that can rapidly change from one sweep rate to another over ranges of picoseconds to milliseconds, enabling collection of both Raman and fluorescence signatures versus time and wavelength, and Synchroscan integration that allows for a compact, low-power laser without compromising ultimate sensitivity.

Blacksberg, Jordana↗

Growth Curve Parameterization of Metabolic Activity of Yeast Cells for BioSentinel

The goal of the BioSentinel small satellite payload is to measure the effect of deep space radiation on the growth and metabolic activity of yeast cells. Raw test data is generated by fluidics cards containing yeast cells rehydrated at different periods, with metabolic activity measured by the reduction of alamarBlue. Each card well has a sensor array that measures the amount of red, green, and infrared light transmitted through the yeast culture. This illumination data is then converted to absorbance values, which are further converted into concentrations. The ultimate objective is to convert these concentrations into biologically-relevant metrics that can be compared against one another to determine changes due to differential radiation exposure. Beginning with IR absorbance data (corresponding to cell density) from ground studies, three parameters from a sigmoidal growth curve were extracted and analyzed: 𝜆 (lag phase), 𝜇 (max growth rate), and A (max cell growth). The data was fit to the Gompertz model of microbial growth using non-linear regression (Minitab), as the fit error was reduced compared to the simpler logistic growth curve. Graphs showed that the data contained a discrepancy (drift) in the lag phase that is attributable to a slow, constant loss of moisture. Correcting this discrepancy by fitting the first 25 hours of the data to a power function and subtracting these values from the absorbance readings obtained a better statistical fit to the growth curve in the lag phase. A power fit was selected over a linear fit because it reflected the effects of constant volume loss. This correction to the BioSentinel data analysis pipeline will enable quantitative statistical analysis of the effect of different levels of deep space radiation on yeast cells. Future work includes automation of drift correction and curve modeling to extract these parameters directly from data.

Growth Curve↗

Martian topography and surface properties as seen by radar - The 1971 opposition.

Taking advantage of the favorable opposition of 1971, the Goldstone radar system, operating at 2388 MHz, was used to scan the Martian surface. Measurements of altitude and reflected power were taken approximately every 3 days. Each measurement represents an area 8 km E-W by 80 km N-S, the highest resolution attained to date. Altitude measurements obtained on different observing days were combined to produce altitude profiles for three complete rotations, each at different latitudes. Large-scale variations in altitudes cover a range of 14 km. Altitude changes of 5 in 30 km of longitude were observed. The altitude profiles show the heavy cratering of the surface, and several large craters (50-100 km) 1-2 km deep are easily seen.

Downs, G. S.↗

HIFOGS: Its design, operations and calibration

The High-efficiency, Infrared Faint Object Grating Spectrometer (HIFOGS) provides spectral coverage of selectable portions of the 3 to 18 micron range at resolving powers from 00 to 1000 using 120 Si/Bi detectors. Additional coverage to 30 microns is provided by a bank of 32 Si:P detectors. Selectable apertures, gratings and band-pass filters provide flexibility to this system. Software for operation of HIFOGS and reduction of the data runs on a MacIntosh computer. HIFOGS has been used to establish celestial flux standards using 3 independent approaches: comparison to star models, comparisons to asteroid models and comparisons to laboratory blackbodies. These standards are expected to have wide application in astronomical thermal-infrared spectroscopy.

Witteborn, Fred C.↗

DESI 2024 VII: cosmological constraints from the full-shape modeling of clustering measurements

We present cosmological results from the measurement of clustering of galaxy, quasar and Lyman-α forest tracers from the first year of observations with the Dark Energy Spectroscopic Instrument (DESI Data Release 1). We adopt the full-shape (FS) modeling of the power spectrum, including the effects of redshift-space distortions, in an analysis which has been thoroughly validated in a series of supporting papers as summarised in [1]. We combine the full-shape information with DESI's DR1 constraints from the baryon acoustic oscillations (BAO) of these tracers. In the flat ΛCDM cosmological model, DESI (FS+BAO), combined with a baryon density prior from Big Bang Nucleosynthesis and a weak prior on the scalar spectral index, determines matter density to Ω m = 0.2962 ± 0.0095, and the amplitude of mass fluctuations to σ 8 = 0.842 ± 0.034. The addition of the cosmic microwave background (CMB) data tightens these constraints to Ω m = 0.3056 ± 0.0049 and σ 8 = 0.8121 ± 0.0053, while further addition of the joint clustering and lensing analysis from the Dark Energy Survey Year-3 (DESY3) data further improves these measurements, and leads to a 0.4% determination of the Hubble constant, H 0 = (68.40 ± 0.27) km s -1 Mpc -1 . In models with a time-varying dark energy equation of state parametrised by w 0 and w a , combinations of DESI (FS+BAO) with CMB and type Ia supernovae continue to show the preference, previously found in the DESI DR1 BAO analysis, for w 0 > -1 and w a < 0 with similar levels of significance. DESI data, in combination with the CMB, improve the upper limits on the sum of the neutrino masses relative to the case when only the DR1 BAO was available, giving ∑m ν < 0.071 eV at 95% confidence. We finally constrain deviations from general relativity represented by two modified gravity parameters. DESI (FS+BAO) data alone measure the parameter that controls the clustering of massive particles, μ 0 = 0.11 +0.45 -0.54 , in agreement with the zero value predicted by general relativity. The combination of DESI with the CMB and the clustering and lensing analysis from DESY3 constrains both modified-gravity parameters, giving μ 0 = 0.04 ± 0.22 and Σ 0 = 0.044 ± 0.047, again in agreement with general relativity.

79 ASTRONOMY AND ASTROPHYSICS↗

Application of Spectroscopic Doppler Velocimetry for Measurement of Streamwise Vorticity

A spectroscopic Doppler velocimetry technique has been developed for measuring two transverse components of velocity and hence streamwise vorticity in free jet flows. The nonintrusive optical measurement system uses Mie scattering from a 200 mW green continuous-wave laser interacting with dust and other tracer particulates naturally present in the air flow to measure the velocities. Scattered light is collected in two opposing directions to provide measurements of two orthogonal velocity components. An air-spaced Fabry-Perot interferometer is used for spectral analysis to determine the optical frequency shift between the incident laser light and the Mie scattered light. This frequency shift is directly proportional to the velocity component in the direction of the bisector of the incident and scattered light wave propagation vectors. Data were acquired for jet Mach numbers of 1.73 and 0.99 using a convergent 1.27-cm diameter round nozzle fitted with a single triangular "delta-tab". The velocity components and the streamwise vorticity calculated from the measurements are presented. The results demonstrate the ability of this novel optical system to obtain velocity and vorticity data without any artificial seeding and using a low power laser system.

Fagan, Amy↗

Characteristics of U.S. Energy Production using Nuclear Fission

When considering potential energy production technologies for the future, a critical consideration centers on the question of “how green” the technology is. Here, the word “green” implies that the technology has a zero or minimal impact on the public and environment while still providing benefits by way of electricity, heat, and other products such as hydrogen and water. And, these potential impacts must be considered over the lifecycle of the technology deployment, from design, construction, operation, and disposition. Ideally, a green energy technology would be net-zero (i.e., having no to almost negligible contribution) on five key elements: 1. Greenhouse gas emissions, including carbon dioxide (CO 2 ), methane, nitrous oxide, and fluorinated gases such as ozone-depleting gases 2. Water consumption 3. Material resource consumption 4. Disposition of wastes 5. Public, flora, and fauna safety including deaths, health, and environmental impacts. Society would benefit from net-zero impacts of the five elements above while having low-cost energy. As society starts to replace fossil fuels in the energy mix, we need to consider the possible impacts of adopted technologies. We need a production approach that provides large quantities of energy while being safe, reliable, economical, and sustainable. In this report, we describe a variety of characteristics related to the five elements above to provide a fact-supported, science-based depiction of nuclear fission as an energy providing technology. By better understanding how fission power is nearly net-zero in the five elements above, we can position our thinking to align with the overarching goal to provide society with a low-impact energy source.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The Mars Environmental Compatibility Assessment (MECA)

The Mars Environmental Compatibility Assessment (MECA) will evaluate the Martian environment for soil and dust-related hazards to human exploration as part of the Mars Surveyor Program 2001 Lander. Sponsored by the Human Exploration and Development of Space (HEDS) enterprise, MECA's goal is to evaluate potential geochemical and environmental hazards that may confront future martian explorers, and to guide HEDS scientists in the development of high fidelity Mars soil simulants. In addition to objectives related to human exploration, the MECA data set will be rich in information relevant to basic geology, paleoclimate, and exobiology issues. The integrated MECA payload contains a wet-chemistry laboratory, a microscopy station, an electrometer to characterize the electrostatics of the soil and its environment, and arrays of material patches to study the abrasive and adhesive properties of soil grains. MECA is allocated a mass of 10 kg and a peak power usage of 15 W within an enclosure of 35 x 25 x 15 cm (figures I and 2). The Wet Chemistry Laboratory (WCL) consists of four identical cells that will accept samples from surface and subsurface regions accessible to the Lander's robotic arm, mix them with water, and perform extensive analysis of the solution. Using an array of ion-specific electrodes (ISEs), cyclic voltammetry, and electrochemical techniques, the chemistry cells will wet soil samples for measurement of basic soil properties of pH, redox potential, and conductivity. Total dissolved material, as well as targeted ions will be detected to the ppm level, including important exobiological ions such as Na, K+, Ca++, Mg++, NH4+, Cl, S04-, HC03, as well as more toxic ions such as Cu++, Pb++, Cd++, Hg++, and C104-. MECA's microscopy station combines optical and atomic-force microscopy (AFM) to image dust and soil particles from millimeters to nanometers in size. Illumination by red, green, and blue LEDs is augmented by an ultraviolet LED intended to excite fluorescence in the sample. Substrates were chosen to allow experimental study of size distribution, adhesion, abrasion, hardness, color, shape, aggregation, magnetic and other properties. To aid in the detection of potentially dangerous quartz dust, an abrasion tool measures sample hardness relative to quartz and a hard glass (Zerodur).

Meloy, Thomas P.↗