Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “graphitization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Safe Electrolytes for Batteries

The demand for reliable and safe lithium-ion batteries (LIBs) for electric vehicles (EVs) and energy storage systems (ESS) necessitates the exploration of nonflammable phosphorus-based electrolytes as alternatives to the traditional flammable carbonate-based ones. However, integrating phosphorus-based electrolyte poses challenges, including capacity fading and compatibility issues with graphite material. Here, a high-throughput (HTP) electrochemical characterization method, similar to PH test paper, is introduced to fast screen compatible phosphorus-based electrolyte for use with graphite. Among 1,740 combinations of phosphorus-based electrolytes and graphite materials, 101 promising combinations are identified for further evaluation. These identified phosphorus-based electrolytes and graphite materials are evaluated and optimized in Li/Graphite half-cells and Graphite/LiFePO 4 (LFP) full-cells using commercial-level electrodes. The desolvation energy of a complex with one Li+ and four solvent molecules of phosphate or carbonate is calculated by density functional theory (DFT). Key parameters such as viscosity, ionic conductivity, and flammability of the electrolytes are thoroughly tested and optimized. The modified phosphate-dominant electrolyte (2 M LiFSI TEP/DME/EC (6/2/2, volume ratio) + 5 wt.% VEC + 5 wt.% FEC) demonstrates excellent thermal stability with lithiated graphite and showcases superior cycling performance in the Graphite/LFP full cell, surpassing prior research findings in phosphate-dominant electrolytes. By the rapid HTP screening and identification of compatible electrolyte-graphite combinations, this approach contributes to expediting the development of safer LIBs for EVs and ESS.

25 ENERGY STORAGE↗

Upcycling Polyethylene Waste to Advanced Carbon Materials for Energy Storage Applications

Polyethylene is notoriously difficult to upcycle because it decomposes into light gases at approximately 350-400 °C which prevents processing it at higher temperatures to convert it into high-value carbon materials, such as graphene or graphite. We address this challenge by using an air-based, thermo-oxidation process, which heats polyethylene (PE) just below the decomposition point to initiate oxidation and cross-linking of PE alkyl chains. These molecular transformations allow PE to be further graphenized or graphitized at higher temperatures without decomposing. The PE-derived graphene has a specific surface area up to 1,800 m 2/g and Raman ID/IG ratio of 0.85, which enables it to be used as an electrode material for a symmetric supercapacitor with the 1 M H2SO4 electrolyte. The PE-derived graphene material has a comparable electrochemical capacitive performance, such as power density, specific capacitance, and long cycle stability, to the commercial state of art porous carbon electrode. The stabilized PE could also be converted into highly crystalline flake graphite via low-temperature catalytic graphitization. The PE-derived graphite is used for the lithium-ion battery anode, which showed comparable electrochemical battery performance, such as reversible rate performance and long-term cyclic stability, to the current use battery-grade graphite, thus providing a scalable method to upcycle PE plastic waste into high-value carbon material.

Gao, Yuan↗

AGC-4 Experiment Irradiation Monitoring Data Qualification Final Report

The Graphite Technology Development Program ran a series of six experiments to quantify the effects of irradiation on nuclear grade graphite. This report focuses on the fourth experiment, Advanced Graphite Creep 4 (AGC 4). The Advanced Reactor Development (ARD) Technology Development Office (TDO) Program for research and development activities require documentation of qualified monitoring data to design and license the first high-temperature reactor nuclear plant. Qualified data meets the requirements for use as described in the experiment planning and quality assurance documents. Failed data do not meet the requirements and provide no useable information. Trend data may not meet all requirements but still provide some useable information. Use of Trend data requires assessment of how any deficiencies affect a particular use of the data. AGC-4 began with Advanced Test Reactor (ATR) Cycle 157D on May 30, 2015. After irradiating the graphite for two cycles, the capsule was removed from the reactor after ATR Cycle 158A, which ended on January 2, 2016, due to interference with another experiment. Irradiation was resumed with Cycle 162A on October 7, 2017 after the interfering experiment was removed from the reactor. AGC-4 irradiation completed by the end of Cycle 166B on January 10, 2020. Between Cycles 162A and 166B, AGC-4 capsule was removed from the reactor core during two Powered Axial Locator Mechanism (PALM) Cycles 163A and 165A to avoid overheating. All thermocouples (TCs) have functioned throughout the AGC-4 experiment. A total of 9,256,184 out of all 11,167,213 temperature records (or 82.9%) are Qualified for use by the ARD Program and 1,911,029 missing values are Failed. Argon, helium, and total gas flow data were within expected ranges, except only eight out-of-range values occurred during outages. A total of 21,240,627 out of all 22,288,5103 gas flow rates (or 92.8%) are Qualified for use by the ARD Program and 1,644,476 are Failed records mostly due to missing values. Discharge gas line moisture values were consistently low during full ATR power, except for 162B, when moisture content was increasing to more than 200 ppmv by the end of this cycle. During outages, moisture content reached as high as 700 ppmv. 1,089,941 out of a total of 1,107,331 moisture values (or 98.4%) are within the measurement range of the instrument and are Qualified for use by the ARD Program and 17,390 missing moisture values are Failed. Graphite creep specimens were subjected to one of three loads: 393, 491, or 589 lbf. For a brief period during Cycle 157D between 12:19 on June 2, 2015, and 08:23 on June 11, 2015, the load cells were wired incorrectly, resulting in missing stack load data. Missing stack loads were estimated from measured ram pressures using regression equations developed from the existing data from Cycle 157D. Estimated stack loads during this period are considered to be an accurate representation of actual load applied to the stacks. These loads deviate slightly from the planned loads. This deviation does not prevent the data from being Qualified for use but must be taken into account when analyzing the effect of load on creep. 6,095,728 out of a total of 6,403,985 moisture values (or 95.2%) are within the measurement range of the instrument and are Qualified for use by the ARD Program and 308,257 missing load values are Failed. Stack displacement increased consistently throughout the eight cycles, with total displacement reached highest value of 2.4 in by the end of irradiation. During ATR outages, a set of pneumatic rams raised the stacks of graphite creep specimens to ensure the specimens were not stuck within the test train. This stack raising was performed seven times throughout irradiation. All stacks were raised successfully each time. 4,744,974 out of a total of 6,094,513 displacement values (or 77.9%) are within the measurement range of the instrument and are Qualified for use by the ARD Program and 1,349,539 displacement values are Failed mostly due to missing values. Analyses were conducted on correlations between TCs to look for trends and step changes that might indicate instrument degradation or failure. Correlation analysis was used to identify instances when TCs form short circuits, referred to as virtual junctions, which result in TCs reporting temperatures from some location in the capsule other than the location where they were intended to read. No evidence of virtual junctions was found. Analyses were also conducted on control charts of temperature differences of between two TCs, which are expected to behave consistently throughout the entire irradiation period. Upward or downward trend over time indicates at least one TC in the pair was drifted. Examining control charts for all 66 possible pairs out of twelve TCs installed in the AGC-4 capsules reveal no clear drift failures occurred, except unstable behavior of two TCs in Zone 3, TC-7 and TC-8, over irradiation time. In conclus

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Baseline Characterization Database Verification Report – 2114 Billet A20568

This ECAR provides the results of a validity evaluation of the physical and mechanical property data collected on a billet of nuclear-grade graphite (i.e., 2114 Billet A20568) in support of the ART Baseline Graphite Characterization Program.1,2 Millions of raw data points have been collected during testing and quantification analyses for these billets. The summary scalar property values and supplementary traceability data are collected into comprehensive spreadsheets. Data sets are composed of single billets of graphite for any given grade, organized by mechanical test-specimen type, and further subdivided into individual spreadsheet tabs according to the specific test or evaluation being performed. A direct analysis of properties was not conducted, and this report does not provide information on the validity or performance characteristics of the graphite itself. Rather, this report is intended as a verification of the completeness of actual data collected in accordance with PLN-3467, “Baseline Graphite Characterization Plan: Electromechanical Testing,”3 and their representation of the measurement and test results with sole regard to the graphite billets under evaluation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Direct recycling of lithium-ion battery scraps for manufacturing a new anode

An improved method of recycling lithium-ion battery anode scraps is provided. The method involves isolating an anode scrap including a graphite anode film adhered to a current collector foil with a polyvinylidene fluoride binder. The anode scrap is combined with deionized water to form a first mixture. The graphite anode film is delaminated from the current collector foil to form a second mixture comprising a free collector foil and a free graphite anode film. The free graphite anode film is filtered and dried from the second mixture to recover the free graphite anode film. The free graphite anode film is combined with a solvent comprising N-methyl-2-pyrrolidone (NMP) to form an anode formation slurry. The slurry is coated onto a copper current collector to produce a new anode.

Bai, Yaocai↗

HDG-1 Experiment Irradiation Monitoring Data Qualification Final Report

SUMMARY The U.S. Department of Energy (DOE) Advanced Reactor Technologies (ART) Graphite Research and Development (GRD) Program is conducting a series of six experiments to quantify the effects of irradiation on nuclear-grade graphite. This report documents the qualification of irradiation monitoring data for the fifth experiment, High Dose Graphite-1 (HDG-1). Qualified monitoring data are required by the ART program to support the design and licensing of the first high-temperature reactor (HTR) nuclear plant. Data are classified as Qualified if they meet the usage requirements described in the experiment planning and quality assurance (QA) documents, Failed if they do not meet those requirements and provide no usable information, or Trend if they do not fully meet all requirements but still provide useful information subject to an assessment of how any deficiencies may affect a particular use of the data. HDG-1 irradiation began with Advanced Test Reactor (ATR) Cycle 168B on August 24, 2020, and concluded after Cycle 173C on January 27, 2025. The HDG-1 capsule was removed from the reactor core twice—during core internal change (CIC) Cycle 170A and powered axial locator mechanism (PALM) Cycle 172A—to prevent overheating of the graphite specimens during high-power PALM cycles. The capsule was therefore irradiated during a total of seven normal ATR cycles: 168B, 169A, 171A, 171B, 173A, 173B, and 173C. Irradiation monitoring data evaluated in this report include thermocouple (TC) temperature, gas flow rate, gas moisture, gas pressure, specimen load, and graphite stack displacement. Temperature. A total of 14,508,065 TC temperature records were captured. Of these, 13,901,785 (95.8%) are Qualified and 606,280 (4.2%) are Failed. The principal source of failed temperature data was the instrument failure of TC-9 (Zone 2) on June 24, 2024, and TC-10 (Zone 1) on July 5, 2024, near the end of Cycle 173A, which resulted in 595,554 Failed readings. An additional 379 missing values and 10,347 slightly negative values from TC-13 during ATR outages are also Failed. Neither TC-9 nor TC-10 was used as a temperature-control TC, and their failures did not compromise capsule condition monitoring. Correlation analysis of all 13 TCs found no evidence of virtual junction formation. Control chart analysis revealed clear downward drift of approximately 80°C for TC-6 (Zone 3) relative to other stable TCs, and possible downward drift of approximately 60°C for TC-13 relative to the Zone 5 control TC (TC-1), though TC-13 remained consistent with the Zone 2 control TC (TC-12). Gas flow. A total of 20,088,090 gas flow rate records were captured. Of these, 19,941,463 (99.3%) are Qualified and 146,627 (0.7%) are Failed due to missing values. All argon, helium, and total gas flow data were within expected ranges throughout the irradiation. Gas moisture. A total of 1,116,005 outlet gas moisture values were captured. Of these, 1,101,421 (98.7%) are Qualified and 14,584 (1.3%) are Failed, comprising 14,556 out-of-range values and 28 missing values. The out-of-range moisture values exceeded 22,000 ppmv for approximately 1 week at the beginning of Cycle 173A, when accumulated moisture evaporated after the capsule was retrieved from water storage during PALM Cycle 172A and reinserted into the east flux trap. Moisture levels returned to below 25 ppmv for the remaining three cycles, and the transient high-moisture event did not affect the integrity of specimen irradiation. Gas pressure. A total of 7,812,035 gas pressure values were captured. Of these, 6,642,048 (85.0%) are Qualified and 1,169,987 (15.0%) outlet pressure values are Failed, comprising 718,537 zero outlet pressure values due to sensor failure from Cycle 168B through Cycle 171B, 54,550 missing values, and 396,900 too-low outlet pressure values, ranging from 1.1 to 1.6 psia after sensor replacement during Cycle 173A. Load. A total of 6,696,030 load values were captured. Of these, 6,694,580 (99.98%) are Qualified and 1,450 (0.02%) are Failed due to missing values. Applied loads to the six specimen stacks were stable throughout the irradiation. Stack displacement. A total of 6,696,030 displacement values were captured. Of these, 5,713,297 (85.32%) are Qualified and 3,781 (0.06%) are Failed due to missing values. Stack displacement increased consistently throughout the irradiation, reaching approximately 3.08 in. for Channels 5 and 6 by the end of irradiation. 978,952 (14.62%) substantially elevated displacements observed for Channel 6 beginning in Cycle 171A and for Channel 5 beginning in Cycle 173A are assigned Trend status. Raising pressure. A total of 1,115,999 raising pressure values were captured. Of these, 1,115,430 (99.95%) are Qualified and 569 (0.05%) are Failed due to missing values. Ram pressure. A total of 6,696,030 ram pressure values were captured. Of these, 6,692,249 (99.95%) are Qualified and 3,484 (0.05%) are Failed due to missing values. Stack raising was perf

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Enabling fast-charging of lithium-ion batteries through printed electrodes

It has been well recognized that introducing secondary porous networks (SPNs) into the electrodes can effectively improve the electrochemical performance of lithium-ion batteries (LIBs), especially under fast-charging operations. However, the process complexity and high cost limit the commercial success of advanced electrodes with SPNs. To address this issue, we developed a facile screen-printing process to produce structured graphite electrodes with SPNs. The experimental results demonstrated that, by tuning the diameter and center-to-center (C2C) distance of emulsion dots on the stencil screen, the pore diameters and C2C pore distances of SPNs in screenprinted electrodes can be precisely controlled in the range of 100 mu m to 1 mm and 100 mu m to 3 mm respectively. In addition, the SPNs with hexagonal and square-shape pore alignments have also been imprinted onto the electrode coatings through adjusting the patterns of screen stencils. Used as anodes, the printed graphite electrodes demonstrated significantly reduced overpotential and voltage fluctuation under fast-charging operations from 2C to 6C. Coupled with LiNi 0.6 Mn 0.2 Co 0.2 O 2 (NMC622) cathodes, the full cells with printed graphite anodes exhibited an unprecedently stable performance with almost no capacity decay up to 170 cycles when charged to 80 % SOC at 2C. Observations from electron microscopy showed plated lithium undetectable at the surface of printed graphite electrodes after numerous cycles. The electrochemical analysis on the voltage evolution during the cell rest period indicated the significantly delayed onset of lithium plating in the presence of printed graphite electrodes. In conclusion, all these results suggest that the significantly improved cell performance is associated with the shortened Li-ion diffusion distance, reduced polarization and suppressed Li plating in the printed electrodes with patterned SPNs.

25 ENERGY STORAGE↗

Gradient porosity electrodes for fast charging lithium-ion batteries

The tendency of Li plating at the surface of thick graphite electrodes greatly limits their application in electrical vehicle (EV) batteries for fast charging applications. To address this concern, we proposed an innovative gradient porosity architecture to facilitate mass transport and suppress Li plating in the thick anodes for fast charging applications. This concept was approved through a thick 3-layered graphite electrode with the highest porosity in the top layer and the lowest porosity in the bottom layer, in contact with the current collector. Here, the gradient porosity structure in the 3-layered graphite electrodes was confirmed by electron microscopy and mercury porosimetry measurements. Used as the anodes of lithium-ion batteries, 3-layered graphite electrodes demonstrated unprecedentedly rate capability and durability superior to 1-layered electrodes. The post-mortem analysis on the cycled cells shows that 3-layered electrodes can significantly suppress Li plating at a high rate up to 4C, which might be responsible for the improved performance of the derived cells. The excellent electrochemical behaviors of 3-layered graphite electrodes are associated with the favored mass transport originating from the unique gradient porosity structure. This is consistent with theoretical studies showing that gradient porosity lowers the Li-ion concentration gradient in the electrolyte in the region close to the separator and slows down the process of reaching the Li plating threshold.

25 ENERGY STORAGE↗

Initial ASME code rule analysis on Simple and Full assessment

ASME & ASTM codes present simple and full assessment methodologies to qualify nuclear grade graphite components. This report explains the theory behind the statistical portion of the codes and describes the issues discussed in a 2020 workshop in the simple assessment, as well as the full assessment. The methodology for the full assessment was developed by Hindley []. He used a validation methodology to match the experimental average failure load of test specimens from several geometries to the calculated 50% POF load to tune the grouping criteria parameters based on an RMSE penalty function. The grouping criteria consists of a minimum volume to satisfy the weakest link theory of the Weibull distribution and a minimum stress range parameter. Hindley’s work found a minimum link volume of 10 times the grain size and a stress range parameter of 7% [satisfy the validation requirements. Several studies found that the link volume of 10 times the grain size was not satisfactory for the volume grouping criteria for graphite grades with fine grains. ASME 2021 code adopted a new volume grouping criteria based on fracture toughness for calculation of the process zone volume. However, errors were found in the ASME 2021 code process zone volume equation and the question is now open as to what volume grouping criteria is satisfactory. This report presents results from sensitivity studies that were done to evaluate the volume grouping criteria effect on the full assessment POF. This report also presents results from sensitivity studies on other aspects of the code that affect the POF, the mesh size and the choice of the Weibull threshold parameter. All three sensitivity studies: the volume grouping criteria, the mesh size, and the threshold parameter choice are found to affect the component qualification decision for components of structural reliability class 1 (SRC-1). The sensitivity analysis results are presented in the body of the report for NBG-18, which is the same grade of graphite as Hindley used in his thesis. Results from NBG-17, IG-110, 2114, and PCEA are presented in the Appendix. For NBG-18, it was found that increasing the threshold increases the POF, finer meshes result in higher POFs, and that smaller link volume requirements lead to higher POFs (which is inconsistent with Hindley’s findings). This report proposes a new validation study similar to Hindley’s []. The purpose of the new validation study is to tune the threshold, mesh size and grouping criteria based on results from multiple grades of graphite, including finer grain graphites T220 (1-3 microns) and NG-CT-50 (5 microns). The test specimens will be broken at 3 labs, such that we can measure between lab measurement variability, with at least 5 test specimens per lab such that the within lab uncertainty can also be measured. Hindley’s validation method tried matching the average experimental load with the median. The future study will attempt to match failures at lower percentiles, which would be closer to the SRC POF limit. We are currently looking into what geometries make sense and the best method to measure multi-axial stress states. These design decisions are still being set.

36 MATERIALS SCIENCE↗

Inkless, dry printing nanographene via in-Situ Coordinated laser ablation and sintering processes

Printing carbon, such as graphene and other carbon structures, for flexible and printed electronics currently relies on either ink-based printing, laser-induced forward transfer (LIFT), or laser-induced graphitization (LIG) to convert carbon-rich precursor materials, such as polymers, to graphene-like carbon structures. Liquid inks contain toxic solvents, surfactants, and stabilizing additives that degrade electrical conductivity and require high-temperature post-processing. On the other hand, LIG is limited by the substrate. Here, this study introduces an additive manufacturing method for dry-printing carbon nanomaterials, ranging from amorphous carbon to crystalline graphene-like structures, on various substrates. The system utilizes laser ablation of a solid graphite target to create pure carbon nanoparticles in situ and on demand. An inert gas carries the nanoparticles onto the substrate, where they can be deposited either as amorphous structures or laser-sintered in real time to form various graphitic structures. The study of laser processing parameters, specifically fluence and pulse repetition frequency, revealed three unique regimes of nanostructure evolution that influence the morphological and electrical properties of these printed structures. Raman spectroscopy confirmed graphitization with a resistivity slightly higher than that of the bulk graphite target. The conductivity/resistivity could be tuned as a function of sintering laser power. Scanning transmission electron microscopy (STEM) revealed that turbostratic nanographene formed with an interlayer spacing of 0.40 nm. Despite ink-based printing methods, such as screen printing, inkjet printing (IJP), and aerosol jet printing (AJP), this eco-friendly and green manufacturing technique could eliminate toxic chemicals, reduce environmental impact, and enable single-step fabrication of carbon-based devices for applications in wearable sensors, energy storage, flexible electronics, and Internet of Things (IoT) devices.

Additive nanomanufacturing↗

Electrochemical behavior and separation of iodide in molten LiF-NaF-KF melt

This work studied the electrochemical behavior of iodide in molten LiF-NaF-KF mixture and the separation of iodide from the molten salt at 973 K using a graphite working electrode. The cyclic voltammetry (CV) and chronoamperometry (CA) measurements indicated an anodic passivation layer was formed on the graphite electrode in this melt and the layer blocked the charge transfer across the electrolyte/electrode interface. However, the added I- ions could pass through the passivation layer and were oxidized at the graphite electrode. The characterization of the obtained products proved that iodide ions was efficiently oxidized to I2 gas during electrolysis. Furthermore, the graphite anode showed excellent stability without any obvious change in dimensions after electrolysis, which showed the high current efficiency of I2 evolution reaction. Thus, the graphite electrode was possible to be served as an excellent anode to separate other anions (such as Br) from molten fluoride salts.

36 MATERIALS SCIENCE↗

Enhancing isotope mixing in U-10Mo downblend castings with electromagnetic stirring

Uranium alloyed with 10 wt percent molybdenum (U-10Mo) is the proposed fuel for use in the United States’ high-performance research reactors. The U-10Mo fuel is fabricated by a two-step casting process that downblends highly enriched uranium with depleted uranium (DU) and/or natural uranium (NU) and subsequently alloys the resulting high-assay low-enriched uranium (HALEU) with Mo. Currently, a two-step casting process is needed to meet the ingots’ U-235 enrichment homogeneity specifications. This work demonstrates the ability to provide more homogeneous U-235 distributions during downblend casting by using zirconia for crucibles rather than graphite. When graphite is used as a crucible, the electromagnetic field produced by the induction heater couples directly with the graphite. Zirconia is nonconducting in this study, and therefore does not couple with the field. The induction field couples directly with the metal, and causes electromagnetic stirring (EMS) in the molten metal pool. Eight downblend casting experiments were carried out in this work. Four were performed with zirconia crucibles and four with graphite crucibles. The U-235 enrichment was measured at nine discrete points in each casting using laser ablation multi-collector inductively coupled mass spectrometry (LA-MC-ICP-MS). The enrichment homogeneity was approximately eight times better in zirconia crucible castings than in graphite crucible castings as measured by the plate enrichment range and enrichment coefficient of variation. The results show a single casting step could be used to meet USHPRR enrichment specifications if electromagnetic stirring is present during casting. A related investigation was carried out to determine whether it is appropriate to measure enrichment on as-cast ingots or whether heat treated specimens should be used to accurately characterize enrichment. The results show that the as-cast microstructure plays a significant role in enrichment homogeneity. It is recommended that all enrichment measurements be done after the homogenization heat treatment typical of U-10Mo processing.

36 MATERIALS SCIENCE↗

Reversible hydrogen storage in multilayer graphane: Lattice dynamics, compressibility, and heat capacity studies

Multilayer graphane (hydride of graphite) is a crystalline hydrocarbon of composition CH, which can be synthesized from graphite and molecular hydrogen at pressures above 2GPa [V.E. Antonov et al. Carbon 100 (2016) 465]. Using X-ray diffraction, this compound was tentatively identified as the “graphane II” phase of 3D-graphane predicted by ab initio calculations [X.-D. Wen et al. PNAS 108 (2011) 6833] and consisting of layers of 2D-graphane in the “chair” conformation. When heated in a vacuum, the compound does not form any intermediate hydrocarbons and reversibly decomposes back into graphite and hydrogen at 770–920 K. In the present work, almost single-phase samples of graphite hydride and deuteride were synthesized at 7.4 GPa and 870 K. Their investigation by inelastic neutron scattering supplemented by ab initio calculations gave spectra g(E) of the phonon density of states with a gap of about 15 meV at approx. 100 meV, which is a unique identifier for the chair form of graphane. The equation of state V(P) of the hydride was studied at room temperature and hydrogen pressures up to 53 GPa by synchrotron X-ray diffraction in a diamond anvil cell. Further, the graphane II phase did not react with the surrounding hydrogen and did not undergo any phase transformations upon the compression and after heating to 1500 K at 53GPa. The high thermal and pressure stability of this exotic phase makes it an important part of the C–H system. The obtained g(E) spectra of graphite hydride and deuteride were used to calculate temperature dependences of their heat capacity. Measurements of the heat capacity at temperatures 120–673 K confirmed the good accuracy of these calculations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Superior long-term cycling of high-voltage lithium-ion batteries enabled by single-solvent electrolyte

A new single-solvent electrolyte system comprising lithium bis(fluorosuflonyl) imide (LiFSI) and beta-fluorinated sulfone (TFPMS) was designed to enable very stable long-term cycling of high-voltage lithium-ion batteries. Compared to other fluorinated solvents such as alpha-fluorinated sulfone (FMES) and fluorinated carbonate (FEMC), which are prone to reduction on the graphite anode, the LiFSI-TFPMS system displayed outstanding compatibility with graphite. While regular carbonate and sulfone from the LiFSI electrolyte system are compatible with the graphite anode, their high solvating power not only induces severe corrosion on the aluminum cathode current collector at high voltage, but also renders a low aggregation level at a normal salt concentration (about 1.0 M), resulting in the formation of an unstable solid-electrolyte interphase (SEI) on the graphite anode. Owing to the low solvating power of TFPMS, the aggregation level of the LiFSI-TFPMS system is relatively high even at normal salt concentration, which not only facilitates the formation of a robust SEI by the sacrificial decomposition of LiFSI, but also suppresses the aluminum corrosion of the LiFSI electrolyte system at high voltage. Together with the high intrinsic anodic stability of TFPMS, the superior cycling performance of graphite parallel to LiNi 0.6 Co 0.2 Mn 0.2 O 2 cells was achieved by employing the non-flammable LiFSI-TFPMS single-solvent electrolyte system.

25 ENERGY STORAGE↗

Proton-Coupled Electron Transfer Mechanisms for CO 2 Reduction to Methanol Catalyzed by Surface-Immobilized Cobalt Phthalocyanine

Immobilized cobalt phthalocyanine (CoPc) is a highly promising architecture for the six-proton, six-electron reduction of CO 2 to methanol. This electroreduction process relies on proton-coupled electron transfer (PCET) reactions that can occur by sequential or concerted mechanisms. Immobilization on a conductive support such as carbon nanotubes or graphitic flakes can fundamentally alter the PCET mechanisms. We use density functional theory (DFT) calculations of CoPc adsorbed on an explicit graphitic surface model to investigate intermediates in the electroreduction of CO 2 to methanol. Our calculations show that the alignment of the CoPc and graphitic electronic states influences the reductive chemistry. These calculations also distinguish between charging the graphitic surface and reducing the CoPc and adsorbed intermediates as electrons are added to the system. This analysis allows us to identify the chemical transformations that are likely to be concerted PCET, defined for these systems as the mechanism in which protonation of a CO 2 reduction intermediate is accompanied by electron abstraction from the graphitic surface to the adsorbate without thermodynamically stable intermediates. Furthermore, this work establishes a mechanistic pathway for methanol production that is consistent with experimental observations and provides fundamental insight into how immobilization of the CoPc impacts its CO 2 reduction chemistry.

Adsorption↗

Cylindricity Sensitivity Thermal Model of the AGR-5/6/7 Experiment in the Advanced Test Reactor

The AGR-5/6/7 experiment is currently being irradiated in the Advanced Test Reactor (ATR) at the Idaho National Laboratory and is approximately 70% complete. Several fuel and material irradiation experiments have been planned for the U.S. Department of Energy Advanced Gas Reactor Fuel Development and Qualification Program, which supports the development and qualification of tristructural isotropic (TRISO) coated particle fuel for use in high-temperature gas-cooled reactors. The goals of these experiments are to provide irradiation performance data to support fuel process development, qualify fuel for normal operating conditions, support development of fuel performance models and codes, and provide irradiated fuel and materials for post-irradiation examination and safety testing. Originally planned and named as separate fuel experiments, but subsequently combined into a single test train, AGR-5/6/7 is testing low-enriched uranium oxycarbide TRISO fuel. The AGR-5/6/7 test train has 5 capsules with thermocouples and independent gas control mixtures. Unique to this paper is a sensitivity study concerning the cylindricity of the graphite holders containing the fuel compacts and their eccentricity in relation to the stainless-steel capsule walls. Each capsule has small nubs on the outside used for centering the graphite holder inside the stainless-steel capsule with a small gas gap used to control temperature. Due to machining tolerances of these nubs and vibration wearing the nubs down when the experiment is running in the reactor, the possibility exists that the holder may move around radially. Each capsule is equipped with several thermocouples placed at various radii and depths within each graphite holder. This paper will show the sensitivity of offsetting the graphite holder for various radii in 45-degree increments around the circle with the objective of minimizing the difference between the measured thermocouples and the modeled thermocouple temperatures. Separate gas mixtures of helium/neon are introduced into this gas gap between the holder and capsule wall and changed as necessary to maintain the desired thermocouple temperatures to keep the fuel compacts at constant temperature as the nuclear reactor conditions change. The goal of the sensitivity study is to find a radius and an angle to offset the holder from perfectly centered for each of the five capsules separately. The complex thermal model includes fission heating, gamma heating, radiation heat transfer, and heat transfer via conduction and radiation across the control gaps. Subroutines linked to the thermal model offer an easy method to offset the graphite holder from the capsule walls without remeshing the entire model.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Thermal neutron scattering cross sections for amorphous carbon

Carbon materials are commonly found in both nuclear reactors and experimental systems. Various carbon structures occur in nuclear applications ranging from crystalline and nuclear graphite to the amorphous carbon seen in next-generation advanced reactor designs. Amorphous carbon is based on a randomized graphite-like structure and offers the unique ability to disperse impurities throughout the bulk composition. A graphite-like amorphous carbon system was modeled using the classical molecular dynamics (MD) code LAMMPS (Large-scale Atomic/Molecular Massively Parallel Simulator). An improved version of the temperature-dependent Adaptive Intermolecular Reactive Empirical Bond Order (AIREBO) potential was used to model the carbon-carbon atomic interactions for the temperature at 300 K along with densities 1.60, 1.70, 1.85, and 2.23 g/cm{sup 3}. From the normalized velocity autocorrelation function (VACF), the phonon density of state (DOS) was then calculated as the Fourier transform of the normalized VACF. This DOS was then used as the primary input for the evaluation of the thermal scattering law (TSL, i.e. S(α,β)) and associated neutron thermal scattering cross sections. The TSL was analyzed using the Full Law Analysis Scattering System Hub (FLASSH). The amorphous structure results in shifts of the phonon DOS to lower energy modes than typically displayed for ideal crystalline graphite. This impact on the DOS is directly reflected in the TSL. Furthermore, the typical optical peak at 0.25 eV for the ideal graphite disappears for amorphous carbon, in good agreement with the expected structure. (authors)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A White Paper: Disposition Options for a High-Temperature Gas-Cooled Reactor

The high-temperature gas-cooled reactor (HTGR) is a uranium-fueled, graphite-moderated, gas-cooled nuclear reactor design concept capable of producing very high core outlet temperatures. Both types of HTGR have the tristructural isotropic (TRISO) fuel kernel at the heart of the fuel design. For the prismatic block-type HTGR, the TRISO particles are overcoated with a resinated graphitic matrix and pressed into fuel compacts, which are then heat treated and placed in the fuel channels of the prismatic-block-shaped fuel assemblies. For the pebble-bed-type HTGR, the TRISO particles are dispersed in a graphitic-matrix sphere, which is the basic unit for the reactor core. Despite having very different fuel designs, both types of HTGR are graphite-moderated, gas-cooled, thermal reactors using many of the same materials. As a result, both prismatic-block-type and pebble-bed-type HTGRs have similar radioactive waste streams, all of which require safe and secure storage and eventual disposition. Modern HTGR designs are based on a long and rich operating history of several different graphite-moderated, gas-cooled, thermal reactors. Several of these reactors have been shut down, the fuel has been placed in safe storage, and they have undergone some degree of decommissioning. As such, there is significant experience in the management of the spent nuclear fuel (SNF) and radioactive wastes associated with operating these reactors. This white paper will, (1) identify the definitions and regulations that apply to the safe and secure management, storage, and disposal of radioactive waste; and (2) identify the key radioactive waste streams from HTGRs and their characteristics. Idaho National Laboratory (INL) has significant experience in the management of SNF from HTGR predecessors. This experience should form the basis for the management and disposition efforts of the radioactive waste from any new HTGR-type small modular reactor, or microreactor intended for deployment at the INL site.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗