Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flow testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Development of a multiphase shock tube for energetic materials characterization.

A novel multiphase shock tube to study particle dynamics in gas-solid flows has been constructed and tested. Currently, there is a gap in data for flows having particle volume fractions between the dusty and granular regimes. The primary purpose of this new facility is to fill that gap by providing high quality data of shock-particle interactions in flows having dense gas particle volume fractions. Towards this end, the facility aims to drive a shock into a spatially isotropic field, or curtain, of particles. Through bench-top experimentation, a method emerged for achieving this challenging task that involves the use of a gravity-fed contoured particle seeder. The seeding method is capable of producing fields of spatially isotropic particles having volume fractions of about 1 to 35%. The use of the seeder in combination with the shock tube allows for the testing of the impingement of a planar shock on a dense field of particles. The first experiments in the multiphase shock tube have been conducted and the facility is now operational.

36 MATERIALS SCIENCE↗

Validation of a Hybrid Domain Overlapping Coupling Between SAM and CFD Against the TALL-3D Transients

The System Thermal Hydraulics (STH) code SAM has been coupled to the Computational Fluid Dynamics (CFD) code Simcenter STAR-CCM+ utilizing a hybrid domain overlapping method with an explicit coupling in time. The coupling aims to extend the STH code’s applicability to scenarios where local momentum and energy transfers are important yet difficult for STH codes to capture, such as three-dimensional (3D) mixing. The coupling method’s numerical stability was verified in the past against two closed-loop configurations, and it was validated against a double T-junction experiment with 3D scalar mixing. In the present work, the coupling method is validated against the TALL-3D STH/CFD coupling benchmark facility. TALL-3D is a three-legged, liquid-metal facility with a large, pool-type enclosure (test section) that exhibits 3D flow effects to be modeled by a CFD code. The rest of the system exhibits approximately 1D behavior well-predicted by an STH code. First, the present STAR-CCM+ CFD model of the 3D test section is validated against experimental data. Then, the SAM-STARCCM+ coupled model is validated against six different TALL-3D steady states, including SAM standalone model results for comparison. Lastly, the SAM-STARCCM+ coupled model is validated against two TALL-3D transients, one exhibiting flow reversal in the test section and one exhibiting nonlinear, Limit Cycle Oscillations (LCO). For the first transient, the SAM-STARCCM+ coupled model properly predicts an increase in the test section’s inlet temperature during flow reversal, and this is not predicted by the SAM standalone model. Following flow reversal, the SAM-STARCCM+ coupled model better-predicts the initial flow recovery and following oscillations as the system approaches a final natural circulation state. For the second transient, no true final steady state is observed due to LCO. Neither the SAM-STARCCM+ coupled model nor the SAM standalone model can perfectly capture the experiment’s changing oscillation frequency during the transient. However, the SAM-STARCCM+ coupled model does reproduce the oscillatory feedback observed in the system. This is a significant achievement as the SAM-STARCCM+ coupled model only uses an explicit coupling in time, as opposed to a semi-implicit coupling. In comparison, previous STH/CFD coupling efforts of the TALL-3D facility required semi-implicit coupling to obtain similar results.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Constant pressure high throughput membrane permeation testing system

The disclosure relates to a membrane testing system for individual evaluation of a plurality of planar membranes subjected to a feed gas on one side and a sweep gas on a second side. The membrane testing system provides a pressurized flow of a feed and sweep gas to each membrane testing cell in a plurality of membrane testing cells while a stream of retentate gas from each membrane testing cell is ported by a retentate multiport valve for sampling or venting, and a stream of permeate gas from each membrane testing cell is ported by a permeate multiport valve for sampling or venting. Back pressure regulators and mass flow controllers act to maintain substantially equivalent gas pressures and flow rates on each side of the planar membrane throughout a sampling cycle. A digital controller may be utilized to position the retentate and permeate multiport valves cyclically, allowing for gas sampling of different membrane cells over an extended period of time.

42 ENGINEERING↗

SOLAR WAVE-FIELD SIMULATION FOR TESTING PROSPECTS OF HELIOSEISMIC MEASUREMENTS OF DEEP MERIDIONAL FLOWS

The meridional flow in the Sun is an axisymmetric flow that is generally directed poleward at the surface, and is presumed to be of fundamental importance in the generation and transport of magnetic fields. Its true shape and strength, however, are debated. We present a numerical simulation of helioseismic wave propagation in the whole solar interior in the presence of a prescribed, stationary, single-cell, deep meridional circulation serving as synthetic data for helioseismic measurement techniques. A deep-focusing time-distance helioseismology technique is applied to the synthetic data, showing that it can in fact be used to measure the effects of the meridional flow very deep in the solar convection zone. It is shown that the ray approximation that is commonly used for interpretation of helioseismology measurements remains a reasonable approximation even for very long distances between 12 Degree-Sign and 42 Degree-Sign corresponding to depths between 52 and 195 Mm. From the measurement noise, we extrapolate that time-resolved observations on the order of a full solar cycle may be needed to probe the flow all the way to the base of the convection zone.

79 ASTRONOMY AND ASTROPHYSICS↗

Precision Tests of the Nonlinear Mode Coupling of Anisotropic Flow via High-Energy Collisions of Isobars

Valuable information on dynamics of expanding fluids can be inferred from the response of such systems to perturbations in their initial geometry. We apply this technique in high-energy 96 Ru+ 96 Ru and 96 Zr+ 96 Zr collisions to scrutinize the expansion dynamics of the quark-gluon plasma, where the initial geometry perturbations are sourced by the differences in deformations and radial profiles between 96 Ru and 96 Zr, and the collective response is captured by the change in anisotropic flow V n between the two collision systems. Using a transport model, we analyze how the nonlinear coupling between lower-order flow harmonics V 2 and V 3 to the higher-order flow harmonics V 4 and V 5 , expected to scale as V 4 NL = χ 4 V 2 2 and V 5NL = χ 5 V 2 V 3 , gets modified as one moves from 96 Ru+ 96 Ru to 96 Zr+ 96 Zr systems. We find that these scaling relations are valid to high precision: variations of order 20% in V 4NL and V 5NL due to differences in quadrupole deformation, octupole deformation, and nuclear skin modify χ 4 and χ 5 by about 1–2%. Percent-level deviations are however larger than the expected experimental uncertainties and could be measured. Therefore, collisions of isobars with different nuclear structures are a unique tool to isolate subtle nonlinear effects in the expansion of the quark-gluon plasma that would be otherwise impossible to access in a single collision system.

Physics↗

A Computationally Efficient Linear Semi-Lagrangian Scheme for the Advection of Microphysical Variables in Cloud-Resolving Models

An efficient semi-Lagrangian (SL) numerical scheme for the advection of positive-definite microphysical variables in cloud-resolving models is proposed. The scheme is a linear combination of SL schemes of the first and second order. The proposed scheme is compared with two high-order, monotonic, nonlinear Eulerian schemes, in two 2D tests. In the first test, advection of a positive scalar field with large gradients is performed within complicated idealized steering flows. In the second test, a hail storm is simulated using the 2D Hebrew University Cloud Model, describing the interactions between 15 size distributions of different microphysical quantities (each distribution is described by 43 mass bins). The proposed scheme is computationally efficient, has a low numerical diffusion and a high level of mass conservation accuracy, and preserves the sum of multiple advected variables as well as the linear relationships between the advected scalar variables. Although the proposed SL scheme is not exactly positive definite, the negative values and their number, which may appear only in the case of very strong gradients, are negligible. The scheme produces results similar to those of nonlinear Eulerian advection schemes while reducing computation time by approximately a factor of 10.

54 ENVIRONMENTAL SCIENCES↗

Design and Development of a Particle Flow Control Mechanism for Particle-Based CSP System Applications

Within particle-based Concentrated Solar Power Systems (CSP), particles are the heat transfer medium, and therefore, the heat transfer effectiveness of these systems is reliant on their ability to effectively control particle mass flow rate. The vast majority of approaches for particle flow control in high temperature CSP is based on a slide-gate approach where a gate is linearly actuated across a tear-drop shaped opening. The slide-gate mechanism has a sensitivity of 0.354 g/s-mm, which is defined as the mass flow rate over the position of the gate. In the present work, we have designed and tested a new particle flow control mechanism with the potential for faster response times and different sensitivities than a slide gate approach enabling more control of particle flow. The new device enables flow control through moving jaws diagonally to change the outlet area. The new devices sensitivity value follows a quadratic curved as compared to the slide-gate’s linear slope over the same jaw movement. A larger sensitivity value is directly related to a quicker response time when utilizing the same actuator.

14 SOLAR ENERGY↗

Design and Development of a Particle Flow Control Mechanism for Particle-Based CSP System Applications

The submission is a two-page extended abstract. Within particle-based Concentrated Solar Power Systems (CSP), particles are the heat transfer medium, and therefore, the heat transfer effectiveness of these systems is reliant on their ability to effectively control particle mass flow rate. The vast majority of approaches for particle flow control in high temperature CSP is based on a slide-gate approach where a gate is linearly actuated across a tear-drop shaped opening. The slide-gate mechanism has a sensitivity of 0.354 g/s-mm, which is defined as the mass flow rate over the position of the gate. In the present work, we have designed and tested a new particle flow control mechanism with the potential for faster response times and different sensitivities than a slide gate approach enabling more control of particle flow.

14 SOLAR ENERGY↗

Evaluating performance of high efficiency mist eliminators

Processing liquid wastes frequently generates off gas streams with high humidity and liquid aerosols. Droplet laden air streams can be produced from tank mixing or sparging and processes such as reforming or evaporative volume reduction. Unfortunately these wet air streams represent a genuine threat to HEPA filters. High efficiency mist eliminators (HEME) are one option for removal of liquid aerosols with high dissolved or suspended solids content. HEMEs have been used extensively in industrial applications, however they have not seen widespread use in the nuclear industry. Filtering efficiency data along with loading curves are not readily available for these units and data that exist are not easily translated to operational parameters in liquid waste treatment plants. A specialized test stand has been developed to evaluate the performance of HEME elements under use conditions of a US DOE facility. HEME elements were tested at three volumetric flow rates using aerosols produced from an iron-rich waste surrogate. The challenge aerosol included submicron particles produced from Laskin nozzles and super micron particles produced from a hollow cone spray nozzle. Test conditions included ambient temperature and relative humidities greater than 95%. Data collected during testing HEME elements from three different manufacturers included volumetric flow rate, differential temperature across the filter housing, downstream relative humidity, and differential pressure (dP) across the filter element. Filter challenge was discontinued at three intermediate dPs and the filter to allow determining filter efficiency using dioctyl phthalate and then with dry surrogate aerosols. Filtering efficiencies of the clean HEME, the clean HEME loaded with water, and the HEME at maximum dP were also collected using the two test aerosols. Results of the testing included differential pressure vs. time loading curves for the nine elements tested along with the mass of moisture and solid material on each element at final dP. Plots of overall filtering efficiencies for DOP (spherical aerosol) and dry surrogate (aspherical aerosols) at specified dPs were computed for each filter. Filtering efficiencies were determined as a function of particle size. Curves were also generated showing the most penetrating particle size as a function of dP. A preliminary set of tests was conducted to evaluate spray location, duration, pressure, and wash volume for in-place cleaning the interior surface (reducing dP) of the HEME element. A variety of nozzle designs were evaluated and test results demonstrated the potential to overload the HEME (saturate filter medium) resulting in very high dPs and extensive drain times. At least one combination of spray nozzle design, spray location on the surface of the element, and spray time/pressure was successful in achieving extension of operational life. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Experimental investigation of subcooled flow boiling of a 50/50 ethylene glycol/water mixture in finned rectangular aluminum channels

Subcooled flow boiling heat transfer experiments were performed with a 50/50 ethylene glycol/water mixture in a finned aluminum channel. The channel represented a hybrid electric vehicle power electronic cold plate receiving a 50/50 mixture from the radiator at 105 degrees C and 2atmospheres. Experiments used a range of mixture flow rates and both top- and bottom-heating situations. Boiling curves were generated, and subcooled flow boiling heat transfer coefficients were determined including the test channel fin effects. Subcooled flow boiling heat transfer coefficients showed a 25-30% increase compared to single-phase convection.

boiling curve↗

Hanford Waste Treatment Plant Effluent Management Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The Hanford Tank Waste Treatment and Immobilization Plant Effluent Management Facility (EMF) stack monitor location was qualified using a combination of scale model stacks to mitigate the risk of identifying that the sampling location does not meet the qualification criteria on the full-scale stack. The LV-S1 scale model stack was used as a baseline, augmented by the LB-S1 and LV-S2 scale model stacks to address the Direct Feed Low Activity Waste Effluent Management Facility Vessel Vent Process (DVP) injection into the main Active Confinement Ventilation (ACV) system duct. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling locations were geometrically similar to the actual stack, and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. The LV-S1, LB-S1, and LV-S2 scale model stack tests have met the criteria of the ANSI/HPS N13.1-1999 standard to demonstrate the stack sampling locations are well mixed. Verification tests of the EMF stack were performed at normal operating conditions. The minimum 1/6 DV value and the maximum 6 DV value from the scale model testing determine the range of stack flow rates for which the full-scale stack may be operated while remaining in compliance with the stack verification criterion. A practical range for the full-scale stack qualification uses the average DV through 6 DV from the scale model tests to compute the corresponding flow rates. Table S1 lists the operating flow rate along with the average and maximum qualified stack flow rate based on the LV-S1 scale model DV values. The operating flow is below the maximum qualified stack flow, which means that the scale model test results are acceptable for stack qualification. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be ≤20°. Second, the velocity uniformity at the full-scale stack must be ≤20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack test at the EMF. Flow angle results were <5°; all flow angle results were within the ≤20° criterion. The velocity uniformity results for each test condition ranged between 2.2% COV and 4.3% COV, all of which were within the range of the target % COV values from the scale model tests on the LV-S1, LB-S1, and LV S2 scale models. Based on these stack verification test results, the EMF filtered exhaust stack sampling location meets the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all planned fan operating configurations. This includes each combination of ACV fans with DVP exhausters. Further changes to the system configuration or operating conditions that are outside the qualified flow rates described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Thermal Hydraulic Validation Report

The test is a classical example of gas flow in a round pipe. It tests the ability of the code to compute the velocity profiles at different dominantly high Reynolds numbers Reynolds number K-E turbulence models are used and to that extent, the test evaluates the implementation of wall functions in the K-E models.

42 ENGINEERING↗

Optimization of Geological Environments for Carbon Dioxide Disposal in Saline Aquifers in the United States (Part One)

High permeability sandstones of the Frio Formation east of Houston, Texas, were selected to test the feasibility of using carbon capture and storage (CCS) in geologic formations as a method to reduce atmospheric buildup of greenhouse gases. The Frio Brine pilot study was based on two small-volume and short-duration CO2 injections into two previously unperturbed brine-bearing sandstone beds typical of the region. These injections were designed to answer key questions about CCS using a process of intensive multiphysics monitoring, pre-, syn-, and post-injection monitoring, and then history-matching to test the correctness of numerical models of flow and geochemical changes. The first test, conducted in September 2004, injected about 1,600 tons of CO2 at a depth of 5,050 ft (~1,540 m) below the surface over 10 days and collected observations over 18 months. The second injection, in September 2006, injected more slowly, about 250 tons over 5 days, into thicker sandstone at 5,400 ft (~1,650 m) below surface. The injection period was brief, and the formation was on the flank of a steeply dipping structural compartment, resulting in monitoring over 5 years and lasting well into the post-injection phase of plume stabilization. This provided the experience and measurements of a complete project that will be helpful in predicting performance of large-volume injections potentially decades-long. The site was closed at experiment end in May 2009.

Hovorka, Susan↗

Current cyclical testing for PV electrical connections

Cyclical testing of electrically conductive bonding (ECB) is provided. Cyclical testing comprises high current flows using multiples of max operating currents and monitoring sensors with periods of no current to accelerate testing of electrical connections employing ECBs.

Lin, Yafu↗

Future Opportunities for LWR Irradiations in US Test Reactors

After several years of relatively low activity in the field of Light Water Reactor (LWR) fuel development, the Department of Energy again began to engage in developing new fuel technologies and irradiation performance data prompted by the Fukushima Daichi nuclear accidents. New competencies for irradiation testing in material test reactors in the United States began to be developed at this time using the Advanced Test Reactor (ATR), High Flux Isotope Reactor (HFIR), Massachusetts Institute of Technology Reactor (MITR), and the Transient Reactor Test Facility (TREAT). Capsules for testing fuel and cladding materials in ATR and HFIR were deployed, a Pressurized Water Reactor (PWR) condition loop for testing fuel rods was established in ATR, cladding corrosion studies were performed using a water loop in MITR, and TREAT pulse testing capabilities were commissioned for fuel rods in water capsules. The more recent and unexpected closure of the Halden Boiling Water Reactor (HBWR) also prompted further investments in Loss of Coolant Accident (LOCA) testing capabilities at TREAT. New configurations of these test devices show further potential in enhanced steam condition control and other investigations are building toward a flowing water loop for testing transient to dryout conditions. The closure of HBWR also prompted a major project currently underway to construct additional water loops in ATR where a novel approach is being pursued to enable Boiling Water Reactor (BWR) conditions. A meaningful collaborative project was awarded to MITR which, amidst an unexpected major overhaul of the reactor, has expanded cladding corrosion test capabilities at MITR. New explorations have led to methods for unique experiments at HFIR including channel box irradiations. New device developments are also bridging toward future potential for instrumented capsule irradiation tests in ATR and HFIR. Finally, a new project referred to as the System Physics Advanced Reactor Critical facility (SPARC) is gaining traction towards a large zero-power reactor able to produce physics validation data for LWR fuel bundle designs with increased enrichment and enhanced absorbers for 24-month operation cycles. This paper provides a brief summary of the status of these irradiation testbed capabilities with an emphasis on current efforts toward future capabilities to obtain new data and maximize the performance potential of LWR fuel technologies.

Woolstenhulme, Nicolas [Idaho National Laboratory ↗

Assessment of a Filtration Waste Qualification Method for LAWPS

The Low-Activity Waste Pretreatment System (LAWPS) facility is planned to pretreat Hanford tank waste supernate by filtering solids and processing through ion exchange columns to remove cesium. The filtration process is achieved through cross flow filtration using a stainless steel Mott filter with a 0.1-micron grade. The goal of this effort was to assess whether a batch, or dead end, filtration (DEF) device replicating the LAWPS cross flow filter could be employed to qualify each feed campaign prior to delivery to LAWPS. The objective for filtration feed qualification is to determine whether the cross-flow filters deployed in LAWPS will remove solids while maintaining a de minimus flow rate of permeate. To that end, the DEF was tested with simulants and the results compared with those obtained from cross flow filtration tests.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗