Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fixed grid”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

642 records · Page 36

Hydrogen Detection Strategies to Support H2@SCALE - The NREL Sensor Laboratory

Hydrogen represents a major pathway to decarbonize and stabilize the national and international energy industry and select manufacturing markets. To facilitate the development of hydrogen markets, the US Department of Energy initiated H2@Scale to bring together stakeholders to advance affordable hydrogen production, transport, storage, and utilization to increase revenue opportunities in multiple energy sectors. One major impediment to hydrogen implementation is cost. To expedite the use of hydrogen in energy and other markets, the United States announced in 2021 the Hydrogen Shot, which seeks to reduce the cost of clean hydrogen by 80% to $1 per 1 kilogram in 1 decade ("1 1 1"). As the cost of hydrogen drops, new applications will emerge that will require unique configurations of existing equipment and infrastructure, and eventually lead to advances in the generation and utilization of hydrogen. As the hydrogen economy expands, sensors and detection methods will need to adapt to changing infrastructure demands to address the primary targets of health & safety, emissions monitoring, and process control. The NREL Sensor Laboratory is playing a pivotal role in advancing the use of hydrogen sensors and detection methodologies in each of these categories to support DOE's mission for safe and efficient utilization in emerging markets. Health & safety monitors are required to ensure that operators and facilities can react to unintended hydrogen releases, either as GH2, LH2, or as a constituent of blends (e.g., natural gas or ammonia). Current detection methodologies focus on safety applications to detect near its lower flammable limit (4 vol %), and typically include point sensors in applications such as fixed or mobile detectors (e.g., personal gas monitors). Methodologies amenable for area detection include acoustic, emerging optical imaging methods, and flame detectors. Comparable detection strategies can be utilized for emissions monitoring and quantization, however few methods can simultaneously cover both low (emissions) and high (health & safety) levels. Deployment of emission level detectors will be required to 1) reduce product loss through small but potentially significant leaks from an environmental or cost perspective, 2) reduce downtime of high demand systems by early identification of eminent system failures (leaks through pump or compressor seals indicative of impending failure), and 3) address potential emission monitoring requirements that may be set by regulating bodies. The first two points should be adopted by industry to reduce the cost-of-goods-sold. The third main category for hydrogen detection relates to process control and may be advantageous for many existing applications. Two main applications are emerging. For example, the purity requirements for hydrogen that is dispensed from refueling systems for hydrogen fuel cell electric vehicles (FCEV) is rigorously regulated by the Standard SAE J2719, which prescribes maximum allowable levels of multiple impurities in the hydrogen fuel and must be verified by a regulatory body. Hydrogen contaminant detectors (HCD) integrated to the fueling station can assure this compliance. HCDs must be able operate in 100% H2 backgrounds and be able to distinguish between multiple contaminants at low ppm to low ppb levels. Secondly, as a strategy to decarbonize the natural gas grid, there are proposals to blend hydrogen with natural gas. This blending will affect transport applications (pipeline infrastructure), stationary combustion systems (turbines), and consumer and commercial appliances. In the short-term, hydrogen levels up to 20% are proposed. Variations in the hydrogen level can have dramatic impact on the combustion process and on the potential response of safety sensors. These mixtures may be regulated so that the concentration at a delivery point must be monitored with high precision. However, routine maintenance may introduce background gases such as ambient air (with water) or maintenance gases (introduced with welding processes or adhesive outgassing.) Therefore, the detection methodology must be robust enough to recover or respond to various contaminants. Several reviews can be found in literature addressing sensing and detection technologies, including their limitations and applications. However, for most applications, limitations can be alleviated by combining various detection techniques either through system integration or implementation of machine learning methods (artificial intelligence). In this presentation, we will discuss several applications, highlight their current approach for hydrogen detection, and suggest detection strategies to supplement their limitations.

ENERGY STORAGE,HYDROGEN↗

MODELS FOR METAL-POOR STARS WITH ENHANCED ABUNDANCES OF C, N, O, Ne, Na, Mg, Si, S, Ca, AND Ti, IN TURN, AT CONSTANT HELIUM AND IRON ABUNDANCES

Recent work has shown that most globular clusters have at least two chemically distinct components, as well as cluster-to-cluster differences in the mean [O/Fe], [Mg/Fe], and [Si/Fe] ratios at similar [Fe/H] values. In order to investigate the implications of variations in the abundances of these and other metals for H-R diagrams and predicted ages, grids of evolutionary sequences have been computed for scaled solar and enhanced {alpha}-element metal abundances, and for mixtures in which the assumed [m/Fe] value for each of the metals C, N, O, Ne, Na, Mg, Si, S, Ca, and Ti has been increased, in turn, by 0.4 dex at constant [Fe/H]. These tracks, together with isochrones for ages from Almost-Equal-To 5 to 14 Gyr, have been computed for -3.0 {<=} [Fe/H] {<=}-0.6, with helium abundances Y = 0.25, 0.29, and 0.33 at each [Fe/H] value, using upgraded versions of the Victoria stellar structure program and the Regina interpolation code, respectively. Turnoff luminosity versus age relations from isochrones are found to depend almost entirely on the importance of the CNO cycle, and thereby mainly on the abundance of oxygen. Since C, N, and O, as well as Ne and S, do not contribute significantly to the opacities at low temperatures and densities, variations in their abundances do not impact the predicted T{sub eff} scale of red giants. The latter is a strong function of the abundances of only Mg and Si (and Fe, possibly to a lesser extent) because they are so abundant and because they are strong sources of opacity at low temperatures. For these reasons, Mg and Si also have important effects on the temperatures of main-sequence stars. Due to their low abundances, Na, Ca, and Ti are of little consequence for stellar models. The effects of varying the adopted solar metals mixture and the helium abundance at a fixed [Fe/H] are also briefly discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

Challenges Associated with In-Situ Calibration of Load Cells in Force Limited Vibration Testing

The difference in mounting configuration between flight and test can significantly impact the effectiveness of the test in environmental vibration testing. Many tests are performed with large electrodynamic shakers, which utilize interfaces that seek to replicate a fixed base, such as slip tables and head expanders. This fixed base configuration is rarely seen in flight configurations; rather a more realistic configuration would include a flexible mounting structure with its own compliance and dynamics. This causes significant over and under tests in various frequency bands depending on the differences between the test article and fixture dynamics. The traditional way of avoiding these high loads is to limit the acceleration responses at multiple locations on the test article. However, the effectiveness of this approach is highly dependent upon the validity of the test article’s analytical in order to derive accurate acceleration response limit specifications. Also this technique requires limiting the acceleration responses at many locations throughout the test article, which may not be implementable due to such things as access and cleanliness issues An improved environmental vibration testing technique known as force limiting incorporates measurements of the forces between the test article and shaker system interface and limiting them to a specification that more accurately replicates the interface impedance of the structure the test article will be mounted to in flight. In effect this transforms the high mechanical impedance at the test article to shaker interface to more closely match the mechanical impedance of the flight interface, which avoids producing the unrealistically high interface loads. Typically force gauges or load cells are used to measure these interface forces. However, utilizing load cells can present a multitude of challenges depending upon such things as their installation method, geometric layout, and test fixture setup. Regardless, it is extremely important to perform an in-situ calibration of the load cells prior to vibration testing at any significant levels. This paper will discuss the challenges associated with utilizing load cells during the NASA Evolutionary Xenon Thruster – Commercial (NEXT-C) gridded ion thruster proto-flight vibration test performed at the NASA Glenn Research Center’s Structural Dynamics Laboratory.

Kenneth J Pederson↗

Challenges Associated with In-Situ Calibration of Load Cells in Force Limited Vibration Testing

The difference in mounting configuration between flight and test can significantly impact the effectiveness of the test in environmental vibration testing. Many tests are performed with large electrodynamic shakers, which utilize interfaces that seek to replicate a fixed base, such as slip tables and head expanders. This fixed base configuration is rarely seen in flight configurations; rather a more realistic configuration would include a flexible mounting structure with its own compliance and dynamics. This causes significant over and under tests in various frequency bands depending on the differences between the test article and fixture dynamics. The traditional way of avoiding these high loads is to limit the acceleration responses at multiple locations on the test article. However, the effectiveness of this approach is highly dependent upon the validity of the test article’s analytical in order to derive accurate acceleration response limit specifications. Also this technique requires limiting the acceleration responses at many locations throughout the test article, which may not be implementable due to such things as access and cleanliness issues An improved environmental vibration testing technique known as force limiting incorporates measurements of the forces between the test article and shaker system interface and limiting them to a specification that more accurately replicates the interface impedance of the structure the test article will be mounted to in flight. In effect this transforms the high mechanical impedance at the test article to shaker interface to more closely match the mechanical impedance of the flight interface, which avoids producing the unrealistically high interface loads. Typically force gauges or load cells are used to measure these interface forces. However, utilizing load cells can present a multitude of challenges depending upon such things as their installation method, geometric layout, and test fixture setup. Regardless, it is extremely important to perform an in-situ calibration of the load cells prior to vibration testing at any significant levels. This paper will discuss the challenges associated with utilizing load cells during the NASA Evolutionary Xenon Thruster – Commercial (NEXT-C) gridded ion thruster proto-flight vibration test performed at the NASA Glenn Research Center’s Structural Dynamics Laboratory.

K. J. Pederson↗

Wireless Power Transfer

Wireless Power Transfer is an innovative approach using magnetic resonance coupling of air core transformers designed for today's growing plug-in electric vehicle market. This technology can provide a convenient, safe and flexible means to charge electric vehicles under stationary and dynamic conditions. Plug-in Electric Vehicles (PEV) are burdened by the need for cable and plug charger, galvanic isolation of the on-board electronics, bulk and cost of this charger and the large energy storage system (ESS) packs needed. With a system where you have to physically plug in there are a number of occasions where the owner could very well forget to charge the vehicle. For stationary applications (like charging of a PHEV at home), ORNL's innovative wireless power transfer technology adds a convenience factor compared to actually plugging in which will mean that the vehicle will have a full charge every morning. Electric vehicle charging must be safe, compact and efficient in order to be convenient for customers. By reconfiguring the transformer and altering the resonance frequency, energy is transferred to the battery with lower energy losses and with fewer demands on the primary circuit by the rest of the transformer system. The ORNL discovery shows that sufficient power for the battery can be transferred from the primary to secondary circuits without significant energy losses if the operating frequency is set at 50% to 95% of the resonance frequency of the circuit. The electrical power is then transmitted to the chargeable battery, which is electrically coupled to the secondary circuit through the air core transformer. Some advantages include: Reduced energy losses during transfer of energy to the battery; A charge potential that is relatively unaffected by up to 25% misalignment of vehicle; and Other receiving components draw less power from the primary circuit. These advantages allow wireless power technology applications to expand at the workplace and beyond as the demand for EV rises. For vehicles that operate over a fixed route such as busses and shuttle vehicles, Wireless Power Transfer (WPT) means that a smaller battery pack can be used. In the traditional system, the battery pack is designed to accommodate the needs of the entire route or shift. With WPT the battery can be downsized because it can be charged when the vehicle stops on its route (a rental car shuttle bus, for example, can charge when it waits in the terminal and again when it waits at the rental car place. Thus the battery only needs enough charge to get to the next stop. This decrease in battery size means significant cost savings to electrify the vehicle. This technology enables efficient "opportunity charging stations" for predefined routes and planned stops reducing down time. Charging can occur in minutes. This improvement also eliminates the harmful emissions that occur in garages while buses are at idle during charging. In larger cities, dynamic charging offers an even greater impact utilizing existing infrastructure. As vehicles travel along busy freeways and interstate systems, wireless charging can occur while the vehicle is in motion. With this technology a vehicle essentially has unlimited electric range while using a relatively small battery pack. In-motion charging stations use vehicle sensors to alert the driver. Traveling at normal speeds, sensors establish in-motion charging. WPT transmit pads sequentially energize to the negotiated power level based on vehicle speed and its requested charging energy. Lower power when vehicle speed is slow and much higher power for faster moving vehicles. Vehicle to Infrastructure communications (V2I) coordinates WPT charging level according to on-board battery pack state-of-charge. V2I activates the roadway transmit pads placing them in standby mode and negotiates charging fee based on prevailing grid rate and vehicle energy demand. Dynamic charging would allow electricity to supply a very large fraction of the energy for the transportation sector and reduce greatly petroleum consumption. Previously worrisome traffic delays now provide longer periods of charge while passing over in-motion chargers. Inclement weather such as rain and snow do not affect the charging capability. At ORNL, we are working to develop the robust nature of wireless power technology to provide a convenient, safe and flexible means to charge electric vehicles under stationary and dynamic conditions.

33 ADVANCED PROPULSION SYSTEMS↗

Eastern Renewable Generation Integration Study

The Eastern Interconnection (EI) is one of the largest power systems in the world, and its size and complexity have historically made it difficult to study in high levels of detail in a modeling environment. In order to understand how this system might be impacted by high penetrations (30% of total annual generation) of wind and solar photovoltaic (PV) during steady state operations, the National Renewable Energy Laboratory (NREL) and the U.S. Department of Energy (DOE) conducted the Eastern Renewable Generation Integration Study (ERGIS). This study investigates certain aspects of the reliability and economic efficiency problem faced by power system operators and planners. Specifically, the study models the ability to meet electricity demand at a 5-minute time interval by scheduling resources for known ramping events, while maintaining adequate reserves to meet random variation in supply and demand, and contingency events. To measure the ability to meet these requirements, a unit commitment and economic dispatch (UC&ED) model is employed to simulate power system operations. The economic costs of managing this system are presented using production costs, a traditional UC&ED metric that does not include any consideration of long-term fixed costs. ERGIS simulated one year of power system operations to understand regional and sub-hourly impacts of wind and PV by developing a comprehensive UC&ED model of the EI. In the analysis, it is shown that, under the study assumptions, generation from approximately 400 GW of combined wind and PV capacity can be balanced on the transmission system at a 5-minute level. In order to address the significant computational burdens associated with a model of this detail we apply novel computing techniques to dramatically reduce simulation solve time while simultaneously increasing the resolution and fidelity of the analysis. Our results also indicate that high penetrations of wind and PV (collectively variable generation (VG)), significantly impact the operation of traditional generating resources and cause these resources to be used less frequently and operate across a broader output range because wind and PV have lower operating costs and variable output levels.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Liquid Salt Combined-Cycle Pilot Plant Design

The work described in this report is responsive to the Office of Fossil Energy program ‘Energy Storage for Fossil Power Generation.’ This Phase I report has been prepared by Pintail Power LLC, with support from Nexant ECA, Electric Power Research Institute (EPRI) and Southern Company Services as a deliverable for the U.S. Department of Energy for NETL Award DE-FE-00320016. The Liquid Salt Combined Cycle™ (LSCC™) technology provides large-scale energy storage integrated with Fossil Electric Generating Units (FEGUs) to meet critical needs in the energy transition by providing: • the lowest cost large-scale storage for time-shifting of renewable energy, • superior fuel efficiency to reduce GHGs from dispatchable resources, • flexible capacity and ramping to balance variability of wind and solar resources, • essential grid stability services to assure reliability of a low-carbon grid. The LSCC approach: • employs equipment that has already been proven in utility service, • uses safe, non-toxic, non-degrading, perpetual-life storage medium, • leverages and repurposes existing FEGU assets, • expands the value stack of energy storage to reduce market, financing, and commodity risks. Pintail Power has developed the LSCC technology to meet the need for reliable, efficient, and cost-effective integration of Variable Renewable Energy (VRE) into a low-carbon electric grid by coupling proven thermal energy storage with proven gas turbines, steam turbines, and heat transfer equipment. This novel approach is intended to address the key issues facing the grid and operators of renewable and fossil generating units including: • Overgeneration and curtailment of renewables, • Need for fast ramping dispatchable resources, • Improved efficiency and flexibility of fossil units, • Additional peaking capacity to support electrification of transportation and heating, • Provision of reliability services to support high penetration of VRE, especially synchronous inertia and fast frequency response. A Technology Readiness assessment by EPRI confirmed that LSCC technology consists of commercially proven hardware used in industrial and utility applications. Although the novel LSCC approach has not yet been demonstrated as a complete system, interfaces between major components have been conservatively specified. A Phase III pilot is planned to demonstrate equipment integration and operation. The patented innovation is removal of the evaporator section from the exhaust heat recovery system, with the evaporation performed by stored energy in a separate steam generator. This arrangement couples renewable and fossil power generation via long-duration energy storage to deliver cost, performance, and operational synergies, including superior charging and discharging flexibility, reduced fuel consumption and lower CO 2 emissions compared to conventional Combined Cycle Power Plants, and low-cost, large-scale energy storage. The LSCC technology is composed of proven equipment integrated with gas turbine exhaust heat in a novel system. During charging, electric heaters raise the salt temperature as it flows from the Cold Salt Tank to the Hot Salt Tank. During discharging, hot salt produces steam from feedwater that is heated with gas turbine exhaust, which also superheats steam to drive a steam turbine. LSCC technology can be added to any combustion-turbine to integrate renewable energy, provide needed grid services, and increase the value of fossil electric generating units based on the technology’s following attributes: • Long-duration storage enables time-shifting of VRE to avoid curtailment and impairment of renewable assets. • Long storage duration combined with fast-charging capability increases arbitrage opportunities by storing more energy when the price is low and discharging more hours when the price is high. • Long storage duration allows resource adequacy to be supplied across multiple days to increase reliability and reduce risk. • The stored energy reduces fuel heat rate and GHG emissions, and increases merit, so the LSCC dispatches earlier and longer to increase the plant’s capacity factor and asset value. • The stored energy enables pre-heating and startup of the steam cycle, without operating the gas turbine, to enable fast startup and ramping when dispatched for discharge. • The steam turbine can operate without the gas turbine so it can provide valuable synchronous inertia during charging without consuming fuel. • Fast frequency response and regulation services can be provided during charging using solid-state heater and pump controls to vary the charge power input in response to grid signals. • The LSCC system can be configured for resilience including black start, islanded/micro-grid operation, and even self-recharging of storage using either gas turbine power or gas turbine exhaust heat. The commercialization plan is to add LSCC technology to existing simple cycle gas turbine power plants with the 50MW GE LM6000 aero-derivative gas turbine as the reference design basis. A Techno-economic assessment of the reference design evaluated the benefits (Levelized Avoided Cost of Energy) and costs (Levelized Cost of Energy). The plant definition included all major systems and budgetary vendor quotes. Pintail Power and NexantECA developed the overall cost estimate for the LSCC plant up to the total plant cost level, following the DOE-NETL cost estimate guidelines at AACE Class 3 (-20%/+30%). This includes the equipment cost, bulk material, direct and indirect labor costs to arrive at the bare erected cost. Engineering costs are factored from the BEC and added to it to arrive at the EPC cost. Process and project contingencies were then factored from the EPC cost and rolled-up to yield the total plant cost of $\$$184 million for 1746 MWh of discharge electricity. • At $\$$105/kWh, the reference plant costs less than any of the Energy Storage Systems evaluated by PNNL in 2020 for the Energy Storage Grand Challenge. Operations and Maintenance cost estimates were scaled from combined cycle practice, assuming that the LSCC unit was co-located with and sharing some labor expense with other units, to arrive at $\$$2.2 million per year. Plant economics were evaluated using prices from the ERCOT Day-Ahead Market for calendar year 2019 (excluding the market disruptions from the COVID pandemic and the February 2020 deep freeze event). Assuming economic dispatch in the ERCOT Day-Ahead market, the reference plant capacity factor would have discharged for 2777 hours at 91.9 MW, a 31.66% capacity factor, with a marginal cost of $\$$25.59/MWh, and a LACE of $\$$82.41/MWh. Fixed charges were calculated according to EIA guidelines to arrive at an LCOE of $\$$83.48. The benefit-to-cost ratio of 0.99 suggests that the reference plant would have been cost-effective and competitive in the market. EPRI interviewed selected utilities to gauge the need for, applicability of and interest in the LSCC system. Several utilities are currently managing increased load growth along with the inclusion of increasing levels of renewable generation, putting pressure on conventional generation by requiring increased turndown requirements and ultimately lower capacity factors. All of the utilities interviewed have CO 2 reduction targets in the 2030-2050 timeframe that will severely limit the participation of fossil generation and require better utilization of carbon free generation. While there is limited opportunity for storage in the current markets, the utilities interviewed stated that there will be a substantial need for long duration energy storage in the future given the expected trends. Utilizing an energy storage system will generally be preferred over new gas capacity in some cases, with the capabilities of the LSCC system being a potential option for retrofit to existing simple cycle gas turbine units, allowing them to deliver greater participation in the market with lower carbon intensity. A technology gap assessment and technology maturation plan identified a pilot-scale demonstration as the final step before commercialization. Key gaps to be addressed during the Phase II FEED (Front-End Engineering Design) are component selection and design, commissioning procedures, and operational procedures and the control system for LSCC charging and discharging. The project team has been expanded to include Wood Group PLC as EPC. The proposed Phase II work leads to a pilot-scale engineering demonstration (TRL 6) to be conducted at Southern Company’s Plant Rowan, where the prototype system will perform “all the functions that will be required of the operational system.” The proposed pilot will facilitate commercialization (TRL-9) by scale-up to utility-scale systems integrated with peaking GTs or directly to facility scale systems using industrial GTs. The conceptual design for the pilot plant focuses on the novel integration aspects of LSCC technology. A slipstream of gas turbine exhaust will feed a waste heat recovery unit coupled to a molten salt steam generator heated by stored energy. The pilot is intended to demonstrate all key operating modes of the LSCC technology during charging, discharging and standby. The pilot equipment will be approximately one-seventh scale of the LM6000 commercial target and is expected to have commercial off-ramp potential for facility-scale applications.

01 COAL, LIGNITE, AND PEAT↗

Distributed Energy Resources Coordination over Time-varying Directed Communication Networks

In this paper, we consider an optimal coordination problem for distributed energy resources (DERs) including distributed generators and energy storage devices. We first propose an algorithm based on the push-sum and gradient method to optimally coordinate storage devices and distributed generators in a distributed manner. In the proposed algorithm, each DER only maintains a set of variables and updates them through information exchange with a few neighboring DERs over a time-varying directed communication network. We show that the proposed distributed algorithm with appropriately chosen step-sizes solve the optimal DER coordination problem if the time-varying directed communication network is uniformly jointly strongly connected, which is a mild condition on the connectivity of communication topologies. The proposed distributed algorithm is illustrated and validated by numerical simulations.

Yang, Tao↗

Automated Cache Performance Analysis And Optimization

While there is no lack of performance counter tools for coarse-grained measurement of cache activity, there is a critical lack of tools for relating data layout to cache behavior to application performance. Generally, any nontrivial optimizations are either not done at all, or are done ”by hand” requiring significant time and expertise. To the best of our knowledge no tool available to users measures the latency of memory reference instructions for particular addresses and makes this information available to users in an easy-to-use and intuitive way. In this project, we worked to enable the Open|SpeedShop performance analysis tool to gather memory reference latency information for specific instructions and memory addresses, and to gather and display this information in an easy-to-use and intuitive way to aid performance analysts in identifying problematic data structures in their codes. This tool was primarily designed for use in the supercomputer domain as well as grid, cluster, cloud-based parallel e-commerce, and engineering systems and middleware. Ultimately, we envision a tool to automate optimization of application cache layout and utilization in the Open|SpeedShop performance analysis tool. To commercialize this software, we worked to develop core capabilities for gathering enhanced memory usage performance data from applications and create and apply novel methods for automatic data structure layout optimizations, tailoring the overall approach to support existing supercomputer and cluster programming models and constraints. In this Phase I project, we focused on infrastructure necessary to gather performance data and present it in an intuitive way to users. With the advent of enhanced Precise Event-Based Sampling (PEBS) counters on recent Intel processor architectures and equivalent technology on AMD processors, we are now in a position to access memory reference information for particular addresses. Prior to the introduction of PEBS counters, cache behavior could only be measured reliably in the aggregate across tens or hundreds of thousands of instructions. With the newest iteration of PEBS technology, cache events can be tied to a tuple of instruction pointer, target address (for both loads and stores), memory hierarchy, and observed latency. With this information we can now begin asking questions regarding the efficiency of not only regions of code, but how these regions interact with particular data structures and how these interactions evolve over time. In the short term, this information will be vital for performance analysts understanding and optimizing the behavior of their codes for the memory hierarchy. In the future, we can begin to ask how data layouts might be changed to improve performance and, for a particular application, what the theoretical optimal performance might be. The overall benefit to be produced by this effort was a commercial quality easy-to- use and scalable performance tool that will allow both beginner and experienced parallel programmers to automatically tune their applications for optimal cache usage. Effective use of such a tool can literally save weeks of performance tuning effort. Easy to use. With the proposed innovations, finding and fixing memory performance issues would be more automated and hide most to all of the performance engineer expertise ”under the hood” of the Open|SpeedShop performance tool. One of the biggest public benefits from the proposed innovations is that it makes performance analysis more usable to a larger group of application developers. Intuitive reporting of results. The Open|SpeedShop performance analysis tool has a rich set of intuitive, yet detailed reports for presenting performance results to application developers. Our goal was to leverage this existing technology to present the results from our memory performance addition to Open|SpeedShop. Suitable for experts as well as novices. Application performance is getting more difficult to measure as the hardware platforms they run on become more complicated. This makes life difficult for the application developer, in that they need to know more about the hardware platform, including the memory system hierarchy, in order to understand the performance of their application. Some application developers are comfortable in that sceario, while others want to do their scientific research and not have to understand all the nuances in the hardware platform they are running their application on. Our proposed innovations were aimed to support both experts and novice performance analysts. Useful in many markets. The enhancement to Open|SpeedShop would appeal to a broader market space, as it will be useful in scientific, commercial, and cloud computing environments. Our goal was to use technology developed initially at the and Lawrence Livermore National Laboratory combined with the development and commercial software experience of the Argo Navis Technologies, LLC (ANT) to form a powerful combination to delivery these objectives.

97 MATHEMATICS AND COMPUTING↗

Economical and Engineering Aspects of Proactive Demand Participation: Centralized versus Bilateral Control Structure

The electric grid of the U.S. is evolving from a system characterized by large and centralized fossil-fueled power plants and passive customers to a network with high penetration of distributed energy resources and proactive customers. This project facilitated the evolution of the U.S. electric power grid by enabling proactive participation of demands in electricity market at the power distribution system level. This project has three major achievements. First, we designed a centralized distribution system operator managed electricity market and developed a three-phase alternating current optimal power flow algorithm to coordinate the operation of large-scale flexible loads and distributed energy resources. Second, we designed a decentralized bilateral coordinate framework for retail electricity market, where each participating customer is capable of making decisions regarding energy production and consumption based on information received from transactive neighbors. Third, the impacts of centralized and decentralized demand-side participation scheme on power system operations were evaluated with both large-scale simulations and hardware-in-the-loop demonstrations. The major activities and specific accomplishments of the technical tasks are summarized in Section II. The detailed design of centralized/hierarchical and decentralized/bilateral retail electricity markets and the comparison between the two markets are described in Section III. The accomplishments and conclusions of the project are presented in Section IV. The major findings of the project falls into three areas, hierarchical distribution system operator managed electricity market, bilateral electricity market and decentralized market coordination, and comparison of centralized and decentralized market coordination mechanisms. In the area of hierarchical distribution system operator managed electricity market design, an integrated wholesale and retail electricity market was shown to be highly effective in extracting the operational flexibility from distributed energy resources to provide services to the wholesale market. A chordal conversion based convex iteration algorithm is not only computationally efficiency but also achieves global optimal solution in coordinating the operations of a large number of heterogeneous distributed energy resources.In the area of decentralized market coordination approach, we showed that bilateral transactions among proactive customers and decentralized transaction clearing mechanism based on simultaneous second-price sealed-bid auction can encourage truthful bidding strategies from the market participations. In addition, the individual customers can rely on a portfolio optimization approach to maximize their returns while minimizing risks. In the area of comparison of centralized and decentralized market coordination mechanisms, we found that the centralized market design results in higher social welfare and lower wholesale market clearing price for electricity. In general, centralized market design favors distributed energy resources and fixed loads. The decentralized market design mostly benefits flexible loads and conventional generators.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Thermochemical Heat Storage for Concentrated Solar Power: Thermochemical System Reactor Design for Thermal Energy Storage

Thermal energy storage (TES) is an integral part of a concentrated solar power (CSP) system. It enables plant operator to generate electricity beyond on sun hours and supply power to the grid to meet peak demand. Current CSP sensible heat storage systems employ molten salts as both the heat transfer fluid and the heat storage media. These systems have an upper operating tempera ture limit of around 400°C. Future TES systems are expected to operate at temperatures between 600°C–1000°C for higher thermal efficiencies which should result in lower electricity cost. To meet future operating temperature and electricity cost requirements, a TES concept utilizing thermochemical cycles (TCs) based on multivalent solid oxides was proposed. The system employs a pair of reduction and oxidation (REDOX) reactions to store and release heat. In the storage step, hot air from the solar receiver is used to reduce the oxidation state of an oxide cation, e.g. Fe 3+ to Fe 2+ . Heat energy is thus stored as chemical bonds and the oxide is “charged”. To discharge the stored energy, the reduced oxide is re-oxidized in air and heat is released. Air is used as both the heat transfer fluid and reactant and no storage of fluid is needed. This project investigated the engineering and economic feasibility of this proposed TES concept. The DOE storage cost and LCOE targets are $\$$15/kWh and $\$$0.09/kWh respectively. Sixteen pure oxides cycles were identified through thermodynamics calculations and literature information. Data showed the kinetics of re-oxidation of the various oxides to be a key barrier to implementing the proposed concept. A down selection was carried out based on operating temperature, materials costs and preliminary laboratory measurements. Cobalt oxide, manganese oxide and barium oxide were selected for developmental studies to improve their REDOX reaction kinetics. A novel approach utilizing mixed oxides to improve the REDOX kinetics of the selected oxides was proposed. It partially replaces some of the primary oxide cations with selected secondary cations. This causes a lattice charge imbalance and increases the anion vacancy density. Such vacancies enhance the ionic mass transport and lead to faster re-oxidation. Re oxidation fraction of Mn 3 O 4 → Mn 2 O 3 and CoO → Co 3 O 4 was improved by up to 16 fold through the addition of a secondary oxide. However, no improvement was obtained in barium based mixed oxides. In addition to enhancing the short term re-oxidation kinetics, it was found that the use of mixed oxides also help to stabilize or even improve the TES properties after long term thermal cycling. Part of this improvement could be attributed to a reduced grain size in the mixed oxides. Based on the measurement results, manganese-iron, cobalt-aluminum and cobalt iron mixed oxides have been proposed for future engineering scale demonstration. Using the cobalt and manganese mixed oxides, we were able to demonstrate charge and discharge of the TES media in both a bench top fixed bed and a rotary kiln-moving bed reactor.

14 SOLAR ENERGY↗

Beamlet based direct aperture optimization for MERT using a photon MLC

Purpose: A beamlet based direct aperture optimization (DAO) for modulated electron radiotherapy (MERT) using photon multileaf collimator (pMLC) shaped electron fields is developed and investigated. Methods: The Swiss Monte Carlo Plan (SMCP) allows the calculation of dose distributions for pMLC shaped electron beams. SMCP is interfaced with the Eclipse TPS (Varian Medical Systems, Palo Alto, CA) which can thus be included into the inverse treatment planning process for MERT. This process starts with the import of a CT-scan into Eclipse, the contouring of the target and the organs at risk (OARs), and the choice of the initial electron beam directions. For each electron beam, the number of apertures, their energy, and initial shape are defined. Furthermore, the DAO requires dose–volume constraints for the structures contoured. In order to carry out the DAO efficiently, the initial electron beams are divided into a grid of beamlets. For each of those, the dose distribution is precalculated using a modified electron beam model, resulting in a dose list for each beamlet and energy. Then the DAO is carried out, leading to a set of optimal apertures and corresponding weights. These optimal apertures are now converted into pMLC shaped segments and the dose calculation for each segment is performed. For these dose distributions, a weight optimization process is launched in order to minimize the differences between the dose distribution using the optimal apertures and the pMLC segments. Finally, a deliverable dose distribution for the MERT plan is obtained and loaded back into Eclipse for evaluation. For an idealized water phantom geometry, a MERT treatment plan is created and compared to the plan obtained using a previously developed forward planning strategy. Further, MERT treatment plans for three clinical situations (breast, chest wall, and parotid metastasis of a squamous cell skin carcinoma) are created using the developed inverse planning strategy. The MERT plans are compared to clinical standard treatment plans using photon beams and the differences between the optimal and the deliverable dose distributions are determined. Results: For the idealized water phantom geometry, the inversely optimized MERT plan is able to obtain the same PTV coverage, but with an improved OAR sparing compared to the forwardly optimized plan. Regarding the right-sided breast case, the MERT plan is able to reduce the lung volume receiving more than 30% of the prescribed dose and the mean lung dose compared to the standard plan. However, the standard plan leads to a better homogeneity within the CTV. The results for the left-sided thorax wall are similar but also the dose to the heart is reduced comparing MERT to the standard treatment plan. For the parotid case, MERT leads to lower doses for almost all OARs but to a less homogeneous dose distribution for the PTV when compared to a standard plan. For all cases, the weight optimization successfully minimized the differences between the optimal and the deliverable dose distribution. Conclusions: A beamlet based DAO using multiple beam angles is implemented and successfully tested for an idealized water phantom geometry and clinical situations.

60 APPLIED LIFE SCIENCES↗