Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fault detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

An Integrated Architecture for Aircraft Engine Performance Monitoring and Fault Diagnostics: Engine Test Results

This paper presents a model-based architecture for performance trend monitoring and gas path fault diagnostics designed for analyzing streaming transient aircraft engine measurement data. The technique analyzes residuals between sensed engine outputs and model predicted outputs for fault detection and isolation purposes. Diagnostic results from the application of the approach to test data acquired from an aircraft turbofan engine are presented. The approach is found to avoid false alarms when presented nominal fault-free data. Additionally, the approach is found to successfully detect and isolate gas path seeded-faults under steady-state operating scenarios although some fault misclassifications are noted during engine transients. Recommendations for follow-on maturation and evaluation of the technique are also presented.

propulsion system performance↗

An Integrated Architecture for Aircraft Engine Performance Monitoring and Fault Diagnostics: Engine Test Results

This paper presents a model-based architecture for performance trend monitoring and gas path fault diagnostics designed for analyzing streaming transient aircraft engine measurement data. The technique analyzes residuals between sensed engine outputs and model predicted outputs for fault detection and isolation purposes. Diagnostic results from the application of the approach to test data acquired from an aircraft turbofan engine are presented. The approach is found to avoid false alarms when presented nominal fault-free data. Additionally, the approach is found to successfully detect and isolate gas path seeded-faults under steady-state operating scenarios although some fault misclassifications are noted during engine transients. Recommendations for follow-on maturation and evaluation of the technique are also presented.

systems health monitoring↗

Methodology for measurement of fault latency in a digital avionic miniprocessor

Using a gate level emulation of a typical avionics miniprocessor, fault injection experiments were performed to (1) determine the time to detect a fault by comparison monitoring, (2) forecast a program's ability to detect faults and (3) validate the fault detection coverage of a typical self test program. To estimate time to detect, six programs ranging in complexity from 6 to 147 instructions, were emulated. Each program was executed repetitively in the presence of a single stuck at fault at a gate node or device pin. Detection was assumed to occur whenever the computed outputs differed from the corresponding outputs of the same program executed in a nonfaulted processor. Histograms of faults detected versus number of repetitions to detection were tabulated. Using a simple model of fault detection, which was based in an analog with the selection of balls in an urn, distributions of time to detect were computed and compared with those obtained empirically. A self test program of 2,000 executable instructions was designed expressly for the study. The only requirement imposed on the design was that it should achieve 95% coverage. The program was executed in the presence of a single stuck-at fault at a gate node on device pin. The proportion of detected faults are tabulated. In all experiments faults were selected at random over gate nodes or device pins.

Mcgough, J. C.↗

Diagnostics Tools Identify Faults Prior to Failure

Through the SBIR program, Rochester, New York-based Impact Technologies LLC collaborated with Ames Research Center to commercialize the Center s Hybrid Diagnostic Engine, or HyDE, software. The fault detecting program is now incorporated into a software suite that identifies potential faults early in the design phase of systems ranging from printers to vehicles and robots, saving time and money.

Source record↗

Pilot Study for Determining HVAC Fault Prevalence from Fault Monitoring Data

HVAC faults in U.S. commercial buildings are estimated to waste 0.7 quads of energy annually and many companies have deployed software at scale for fault detection and diagnosis (FDD). Yet the lack of comprehensive published data on fault prevalence makes it difficult for researchers, software developers, and building operators to target the most important types of faults and accelerate the widespread deployment of this technology. A multi-lab effort is underway to quantify the prevalence of commercial building HVAC faults. This paper describes initial analysis conducted on over 2-years of FDD data from 12 campus buildings to inform the methodology and data collection strategy of the full study. The analysis found a large variability in fault prevalence across different buildings, pieces of equipment, and fault types, many duplicate fault alarms, and challenges in validating faults with secondary data sources such as manually entered work order data. This paper also discusses the requirements for a successful full study, which necessitates the acquisition of a large, diverse dataset, from buildings that vary in end-use, climate region, and installed FDD software platform, as well as robust validation data easily linked to the FDD data. It is especially important to perform this analysis on data from multiple FDD providers and building owners to ensure that the results are agnostic to the software methodology used and building-specific settings. Future work will present the results of the full study, which will contain data from several different partner organizations, spanning a large proportion of U.S. climate zones.

Newman, Sarah F.↗

Smart connected worker edge platform for smart manufacturing: Part 2—Implementation and on‐site deployment case study

Abstract In this paper, we describe specific deployments of the Smart Connected Worker (SCW) Edge Platform for Smart Manufacturing through implementation of four instructive real‐world use cases that illustrate the role of people in a Smart Manufacturing paradigm through which affordable, scalable, accessible, and portable (ASAP) information technology (IT) acquires and contextualizes data into information for transmission to operation technologies (OT). For case one, the platform captures the relationships between energy consumption and human workflows for improved energy productivity while workers interact with machines during semiconductor manufacturing. The platform utilizes human cognition to identify anomalous machine behavior for root cause analysis of system faults via neural network (NN) that recognize alarm postures of workers with cameras. For case two, a smart assembly line is demonstrated for state monitoring and fault detection. Machine learning (ML) models are used to recognize system states and identify fault scenarios with human intervention. For case three, the platform monitors human–machine interactions to classify manufacturing machine states for proper operations and energy productivity. Internal energy states of individual or collections of manufacturing equipment are determined via NN based algorithms that disaggregate signals associated with smart metering typically deployed at manufacturing facilities. These methods predict the real time energy profile of each machine from the total energy profile of a manufacturing site. For case four, a software defined sensor system built with scientific workflow engines is demonstrated for contextualizing data from laser surface refraction for characterization, and diagnostics in the processing of additively manufactured titanium alloy.

Donovan, Richard P.↗

Modeling of HVAC operational faults in building performance simulation

Operational faults are common in the heating, ventilating, and air conditioning (HVAC) systems of existing buildings, leading to a decrease in energy efficiency and occupant comfort. Various fault detection and diagnostic methods have been developed to identify and analyze HVAC operational faults at the component or subsystem level. However, current methods lack a holistic approach to predicting the overall impacts of faults at the building level—an approach that adequately addresses the coupling between various operational components, the synchronized effect between simultaneous faults, and the dynamic nature of fault severity. This study introduces the novel development of a fault-modeling feature in EnergyPlus which fills in the knowledge gap left by previous studies. This paper presents the design and implementation of the new feature in EnergyPlus and discusses in detail the fault-modeling challenges faced. The new fault-modeling feature enables EnergyPlus to quantify the impacts of faults on building energy use and occupant comfort, thus supporting the decision making of timely fault corrections. Including actual building operational faults in energy models also improves the accuracy of the baseline model, which is critical in the measurement and verification of retrofit or commissioning projects. As an example, EnergyPlus version 8.6 was used to investigate the impacts of a number of typical operational faults in an office building across several U.S. climate zones. Finally, the results demonstrate that the faults have significant impacts on building energy performance as well as on occupant thermal comfort. Finally, the paper introduces future development plans for EnergyPlus fault-modeling capability.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Active Fault Current Limiting Control for Half-Bridge MMC in HVDC Systems

DC faults of MMC can result in a significantly large fault current due to the discharge of submodule capacitors. The fault current not only risks damaging the MMC but also demands a considerable breaking capacity from the dc circuit breaker (DCCBs). This paper introduces two novel active fault current limiting methods (AFCLs), namely virtual impedance-based and energy control-based AFCL. The first method utilizes circulating current feedforward, which introduces a virtual arm impedance to suppress the rate of rise of the fault current. Meanwhile, the second method relies on the control of the internally stored energy of the MMC to automatically minimize the number of submodules that discharge during a dc-side fault. Therefore, both the dc-side current and the MMC arm current can be effectively suppressed after the occurrence of the fault. The proposed methods do not require fault detection and their response is proportional to the rate of rise in the fault current. Simulation case studies are presented to demonstrate the proposed methods.

active current limiting control↗

Demonstration of a fault impact reduction control module for wind turbines

Abstract. Traditionally, wind turbines in distributed applications make control decisions as isolated systems. They generally provide maximum power output during operation and manage internal faults with little consideration of the rest of the power system. Although fault detection and tolerance schemes are widely researched and implemented, controls to ameliorate such faults are uncommon in research and industry. The rapid shutdown of a wind turbine in a large transmission-connected wind plant will have a minimal impact on a large power system, but in a microgrid or isolated grid context the abrupt loss of a single wind turbine may cause grid instability and high stress on the system. This paper demonstrates a fault impact reduction control (FIRC) module for a wind turbine, which implements wider warning thresholds around fault thresholds. When the turbine crosses a warning threshold, the controller sends its predicted action to the grid controller, which facilitates the grid operator’s response to a potential wind turbine fault and then takes appropriate action to ameliorate the fault. Various test cases demonstrate the controller action under a variety of faults, and various scenarios demonstrate the grid benefit of an FIRC in both microgrid- and grid-connected contexts. The FIRC maximizes wind turbine generation and eases generation transition under a variety of fault scenarios. The FIRC module is easy to integrate with most existing controllers, just requiring derate capability, and can be easily modified to include the various warnings and thresholds that the user desires. This analysis is mainly performed in a MATLAB-Simulink-based research wind turbine model and is also implemented in the existing LabVIEW-based controller of the same research turbine at NREL.

17 WIND ENERGY↗

Critical fault patterns determination in fault-tolerant computer systems

The method proposed tries to enumerate all the critical fault-patterns (successive occurrences of failures) without analyzing every single possible fault. The conditions for the system to be operating in a given mode can be expressed in terms of the static states. Thus, one can find all the system states that correspond to a given critical mode of operation. The next step consists in analyzing the fault-detection mechanisms, the diagnosis algorithm and the process of switch control. From them, one can find all the possible system configurations that can result from a failure occurrence. Thus, one can list all the characteristics, with respect to detection, diagnosis, and switch control, that failures must have to constitute critical fault-patterns. Such an enumeration of the critical fault-patterns can be directly used to evaluate the overall system tolerance to failures. Present research is focused on how to efficiently make use of these system-level characteristics to enumerate all the failures that verify these characteristics.

Mccluskey, E. J.↗

Applying Model-Based Reasoning to the FDIR of the Command and Data Handling Subsystem of the International Space Station

All of the International Space Station (ISS) systems which require computer control depend upon the hardware and software of the Command and Data Handling System (C&DH) system, currently a network of over 30 386-class computers called Multiplexor/Dimultiplexors (MDMs)[18]. The Caution and Warning System (C&W)[7], a set of software tasks that runs on the MDMs, is responsible for detecting, classifying, and reporting errors in all ISS subsystems including the C&DH. Fault Detection, Isolation and Recovery (FDIR) of these errors is typically handled with a combination of automatic and human effort. We are developing an Advanced Diagnostic System (ADS) to augment the C&W system with decision support tools to aid in root cause analysis as well as resolve differing human and machine C&DH state estimates. These tools which draw from sources in model-based reasoning[ 16,291, will improve the speed and accuracy of flight controllers by reducing the uncertainty in C&DH state estimation, allowing for a more complete assessment of risk. We have run tests with ISS telemetry and focus on those C&W events which relate to the C&DH system itself. This paper describes our initial results and subsequent plans.

Robinson, Peter↗

Adaptive Threshold-Based Zonal Isolation of Faults in a Multiterminal DC Using Local Measurements

Fast and accurate methods of fault detection and isolation are a pre-emptive measure in multiterminal dc (MTdc) systems. Zonal isolation of faults is necessary to prevent any misopertation of the dc breakers that can lead to a shutdown of the network. Existing techniques require fast-communication or data synchronization methods have their own disadvantages. This article proposes a method for efficient fault zone isolation without the need of a communication link that prevents any misoperation of the dc breakers in a radial MTdc. This method provides individual local measurement-based control to the hybrid dc circuit breakers (dcCB). Faults created outside the zone of protection for a breaker create a change in the rate of change of current or voltage leading to misoperation. To avoid detection using a fixed threshold, an adaptive threshold based approach is suggested that updates the threshold based on the present operating status. Sensitivity analysis by varying the current limiting inductance and fault location is performed. In conclusion, a three terminal radial model of an MTdc is used for zonal isolation using power system computer aided design/electromagnetic transients including dc.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Monitoring and decision making by people in man machine systems

The analysis of human monitoring and decision making behavior as well as its modeling are described. Classic and optimal control theoretical, monitoring models are surveyed. The relationship between attention allocation and eye movements is discussed. As an example of applications, the evaluation of predictor displays by means of the optimal control model is explained. Fault detection involving continuous signals and decision making behavior of a human operator engaged in fault diagnosis during different operation and maintenance situations are illustrated. Computer aided decision making is considered as a queueing problem. It is shown to what extent computer aids can be based on the state of human activity as measured by psychophysiological quantities. Finally, management information systems for different application areas are mentioned. The possibilities of mathematical modeling of human behavior in complex man machine systems are also critically assessed.

Johannsen, G.↗

Advanced information processing system: Fault injection study and results

The objective of the AIPS program is to achieve a validated fault tolerant distributed computer system. The goals of the AIPS fault injection study were: (1) to present the fault injection study components addressing the AIPS validation objective; (2) to obtain feedback for fault removal from the design implementation; (3) to obtain statistical data regarding fault detection, isolation, and reconfiguration responses; and (4) to obtain data regarding the effects of faults on system performance. The parameters are described that must be varied to create a comprehensive set of fault injection tests, the subset of test cases selected, the test case measurements, and the test case execution. Both pin level hardware faults using a hardware fault injector and software injected memory mutations were used to test the system. An overview is provided of the hardware fault injector and the associated software used to carry out the experiments. Detailed specifications are given of fault and test results for the I/O Network and the AIPS Fault Tolerant Processor, respectively. The results are summarized and conclusions are given.

Burkhardt, Laura F.↗

NASA Space Flight Vehicle Fault Isolation Challenges

The Space Launch System (SLS) is the new NASA heavy lift launch vehicle and is scheduled for its first mission in 2017. The goal of the first mission, which will be uncrewed, is to demonstrate the integrated system performance of the SLS rocket and spacecraft before a crewed flight in 2021. SLS has many of the same logistics challenges as any other large scale program. Common logistics concerns for SLS include integration of discrete programs geographically separated, multiple prime contractors with distinct and different goals, schedule pressures and funding constraints. However, SLS also faces unique challenges. The new program is a confluence of new hardware and heritage, with heritage hardware constituting seventy-five percent of the program. This unique approach to design makes logistics concerns such as testability of the integrated flight vehicle especially problematic. The cost of fully automated diagnostics can be completely justified for a large fleet, but not so for a single flight vehicle. Fault detection is mandatory to assure the vehicle is capable of a safe launch, but fault isolation is another issue. SLS has considered various methods for fault isolation which can provide a reasonable balance between adequacy, timeliness and cost. This paper will address the analyses and decisions the NASA Logistics engineers are making to mitigate risk while providing a reasonable testability solution for fault isolation.

Bramon, Christopher↗

Enhanced Bank of Kalman Filters Developed and Demonstrated for In-Flight Aircraft Engine Sensor Fault Diagnostics

In-flight sensor fault detection and isolation (FDI) is critical to maintaining reliable engine operation during flight. The aircraft engine control system, which computes control commands on the basis of sensor measurements, operates the propulsion systems at the demanded conditions. Any undetected sensor faults, therefore, may cause the control system to drive the engine into an undesirable operating condition. It is critical to detect and isolate failed sensors as soon as possible so that such scenarios can be avoided. A challenging issue in developing reliable sensor FDI systems is to make them robust to changes in engine operating characteristics due to degradation with usage and other faults that can occur during flight. A sensor FDI system that cannot appropriately account for such scenarios may result in false alarms, missed detections, or misclassifications when such faults do occur. To address this issue, an enhanced bank of Kalman filters was developed, and its performance and robustness were demonstrated in a simulation environment. The bank of filters is composed of m + 1 Kalman filters, where m is the number of sensors being used by the control system and, thus, in need of monitoring. Each Kalman filter is designed on the basis of a unique fault hypothesis so that it will be able to maintain its performance if a particular fault scenario, hypothesized by that particular filter, takes place.

Kobayashi, Takahisa↗

Investigation of the applicability of a functional programming model to fault-tolerant parallel processing for knowledge-based systems

In a fault-tolerant parallel computer, a functional programming model can facilitate distributed checkpointing, error recovery, load balancing, and graceful degradation. Such a model has been implemented on the Draper Fault-Tolerant Parallel Processor (FTPP). When used in conjunction with the FTPP's fault detection and masking capabilities, this implementation results in a graceful degradation of system performance after faults. Three graceful degradation algorithms have been implemented and are presented. A user interface has been implemented which requires minimal cognitive overhead by the application programmer, masking such complexities as the system's redundancy, distributed nature, variable complement of processing resources, load balancing, fault occurrence and recovery. This user interface is described and its use demonstrated. The applicability of the functional programming style to the Activation Framework, a paradigm for intelligent systems, is then briefly described.

Harper, Richard↗