Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “failure reports”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Wind turbine reliability : a database and analysis approach.

The US wind Industry has experienced remarkable growth since the turn of the century. At the same time, the physical size and electrical generation capabilities of wind turbines has also experienced remarkable growth. As the market continues to expand, and as wind generation continues to gain a significant share of the generation portfolio, the reliability of wind turbine technology becomes increasingly important. This report addresses how operations and maintenance costs are related to unreliability - that is the failures experienced by systems and components. Reliability tools are demonstrated, data needed to understand and catalog failure events is described, and practical wind turbine reliability models are illustrated, including preliminary results. This report also presents a continuing process of how to proceed with controlling industry requirements, needs, and expectations related to Reliability, Availability, Maintainability, and Safety. A simply stated goal of this process is to better understand and to improve the operable reliability of wind turbine installations.

17 WIND ENERGY↗

Extent-of-Condition Review of Electrical Events Fiscal Year 2019

Sandia National Laboratories has experienced a number of electrical events in recent years. A careful examination of data shows that for the third year in a row, two of the three most frequently categorized Occurrence Reporting and Processing System (ORPS)-reportable event types were unexpected or unintended personal contact with a hazardous energy source and a failure to follow a prescribed hazardous energy control process, as defined in the occurrence reporting criteria of DOE Order 232.2A, Occurrence Reporting and Processing of Operations Information, 2D(1) and 2D(2). Sandia policy CA001.2, Identify and Manage Issues, requires an extent-of-condition review for any high-level reportable occurrence, and the analysts were tasked to perform this EOC in light of high-level reportable occurrence NA-SS-SNL-1000-2019- 0007, Contact with Electrical Energy During Marx Capacitor Troubleshooting. This extent of condition not only evaluated the 10 reportable electrical occurrences for Fiscal Year 2019, but also looked at 11 other related events: those involving control of hazardous energy and electrical events associated with less than hazardous energy.1 This Extent-of-Condition report makes several observations, conclusions, and recommendations for improvement.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

NINTH INTERIM STATUS REPORT: MODEL 9975 PCV O-RING FIXTURE LONG-TERM LEAK PERFORMANCE

A series of experiments to monitor the aging performance of Viton® GLT O-rings used in the Model 9975 package has been ongoing since 2004 at the Savannah River National Laboratory. One approach has been to periodically evaluate the leak performance of O-rings being aged in mock-up 9975 Primary Containment Vessels (PCVs) at elevated temperatures. Other methods such as compression-stress relaxation (CSR) tests and field surveillance are also on-going to evaluate O-ring behavior. Seventy tests using PCV mock-ups were assembled and heated to temperatures ranging from 200 to 450 ºF. They were leak-tested initially and have been tested periodically to determine if they continue to meet the leak-tightness criterion defined in ANSI standard N14.5-97. Due to material substitution, fourteen additional tests were initiated in 2008 with GLT-S O-rings heated to temperatures ranging from 200 to 400 ºF. High temperature aging continues for 23 GLT O-ring fixtures at 200 – 270 ºF. Room temperature leak test failures have been experienced in all of the GLT O-ring fixtures aging at 350 ºF and higher temperatures, and in 8 fixtures aging at 300 ºF. The earliest 300 °F GLT O-ring fixture failure was observed at 34 months. The remaining GLT O-ring fixtures aging at 300 ºF have been retired from testing following more than 5 years at temperature without failure. No failures have yet been observed in GLT O-ring fixtures aging at 200 ºF for 72 - 96 months, which bounds O-ring temperatures anticipated during storage in K-Area Complex (KAC). Based on expectations that the 200 ºF fixtures will remain leak-tight for a significant period yet to come, 2 additional fixtures began aging in 2011 at 270 ºF, with hopes that they may reach a failure condition before the 200 ºF fixtures, thus providing additional time to failure data. High temperature aging continues for 6 GLT-S O-ring fixtures at 200 – 300 ºF. Room temperature leak test failures have been experienced in all 8 of the GLT-S O-ring fixtures aging at 350 and 400 ºF. No failures have yet been observed in GLT-S O-ring fixtures aging at 200 - 300 ºF for 54 - 57 months. No additional O-ring failures have been observed since the last interim report was issued. Aging and periodic leak testing will continue for the remaining PCV fixtures. Additional irradiation of several fixtures is recommended to maintain a balance between thermal and radiation exposures similar to that experienced in storage, and to show the degree of consistency of radiation response between GLT and GLT-S O-rings.

42 ENGINEERING↗

Survey of Aging and Monitoring Concerns for Cables and Splices Due to Cable Repair and Replacement

The purpose of this report is to survey aging and monitoring concerns for electrical cable splices in nuclear power plants (NPPs) in long term operation. As portions of existing electrical cable runs in nuclear are replaced over time due to localized events, the total number of splices in NPPs is expected to increase. Relative to cables, the body of knowledge regarding aging of splices and splices in combination with aging cables in nuclear service environments in long-term operations is low. A few reports have considered the aging of cable system components other than cables (Jacobus 1990; Nelson 1998; Villaran and Lofaro 2002), but the nuclear industry has two decades of operating experience since these were published to further enlighten this issue. Herein we discuss electrical cables and splices commonly found in U.S. nuclear power plants, their qualification in safety-related application, and methods for monitoring their health condition. Common environmental stresses that can give rise to cable and splice failure are discussed. The Nuclear Regulatory Commission (NRC) Licensee Event Reports (LER) database was used to identify documented issues of cable and splice failure. The trend in the resultant data over time is considered to see if failures are increasing as plants age. Observations and conclusions of this work include: 1. Cables and splices are highly reliable components. Occurrence rates for events of interest were low and nearly constant over the last 20 years. 2. Common-cause failure for evaluated cable events of interest was observed to primarily be associated with loose connections, which may manifest associated with workmanship issues, thermal cycling, and/or vibration. 3. Replacement of cables is more common than repair, leading to an increase in proportion of new generation cables in the plant over time. 4. Splices on degraded cables have been observed to be problematic. Due to aging NPP infrastructure, including electrical cables, it is expected that such issues will continue to increase. 5. Condition monitoring approaches, while shown to be fruitful for cables, have been shown to be insensitive to degradation of splice sleeves, which are critical to the continued performance of splices. Additional condition monitoring (CM) work is needed to evaluate methods which are sensitive to the degradation of splice components. 6. Extended Material Degradation Assessment (EMDA) knowledge gaps for electrical cables (Bernstein et al. 2014) have not been investigated for splices but may represent similar concerns such as for the accelerated aging process historically used in environmental qualification.

42 ENGINEERING↗

NASA Taxonomies for Searching Problem Reports and FMEAs

Many types of hazard and risk analyses are used during the life cycle of complex systems, including Failure Modes and Effects Analysis (FMEA), Hazard Analysis, Fault Tree and Event Tree Analysis, Probabilistic Risk Assessment, Reliability Analysis and analysis of Problem Reporting and Corrective Action (PRACA) databases. The success of these methods depends on the availability of input data and the analysts knowledge. Standard nomenclature can increase the reusability of hazard, risk and problem data. When nomenclature in the source texts is not standard, taxonomies with mapping words (sets of rough synonyms) can be combined with semantic search to identify items and tag them with metadata based on a rich standard nomenclature. Semantic search uses word meanings in the context of parsed phrases to find matches. The NASA taxonomies provide the word meanings. Spacecraft taxonomies and ontologies (generalization hierarchies with attributes and relationships, based on terms meanings) are being developed for types of subsystems, functions, entities, hazards and failures. The ontologies are broad and general, covering hardware, software and human systems. Semantic search of Space Station texts was used to validate and extend the taxonomies. The taxonomies have also been used to extract system connectivity (interaction) models and functions from requirements text. Now the Reconciler semantic search tool and the taxonomies are being applied to improve search in the Space Shuttle PRACA database, to discover recurring patterns of failure. Usual methods of string search and keyword search fall short because the entries are terse and have numerous shortcuts (irregular abbreviations, nonstandard acronyms, cryptic codes) and modifier words cannot be used in sentence context to refine the search. The limited and fixed FMEA categories associated with the entries do not make the fine distinctions needed in the search. The approach assigns PRACA report titles to problem classes in the taxonomy. Each ontology class includes mapping words - near-synonyms naming different manifestations of that problem class. The mapping words for Problems, Entities and Functions are converted to a canonical form plus any of a small set of modifier words (e.g. non-uniformity NOT + UNIFORM.) The report titles are parsed as sentences if possible, or treated as a flat sequence of word tokens if parsing fails. When canonical forms in the title match mapping words, the PRACA entry is associated with the corresponding Problem, Entity or Function in the ontology. The user can search for types of failures associated with types of equipment, clustering by type of problem (e.g., all bearings found with problems of being uneven: rough, irregular, gritty ). The results could also be used for tagging PRACA report entries with rich metadata. This approach could also be applied to searching and tagging failure modes, failure effects and mitigations in FMEAs. In the pilot work, parsing 52K+ truncated titles (the test cases that were available), has resulted in identification of both a type of equipment and type of problem in about 75% of the cases. The results are displayed in a manner analogous to Google search results. The effort has also led to the enrichment of the taxonomy, adding some new categories and many new mapping words. Further work would make enhancements that have been identified for improving the clustering and further reducing the false alarm rate. (In searching for recurring problems, good clustering is more important than reducing false alarms). Searching complete PRACA reports should lead to immediate improvement.

Malin, Jane T.↗

High-Field Fast-Risetime Pulse Failures in 4H- and 6H-SiC pn Junction Diodes

We report the observation of anomalous reverse breakdown behavior in moderately doped (2-3 x 10(exp 17 cm(exp -3)) small-area micropipe-free 4H- and 6H-SiC pn junction diodes. When measured with a curve tracer, the diodes consistently exhibited very low reverse leakage currents and sharp repeatable breakdown knees in the range of 140-150 V. However, when subjected to single-shot reverse bias pulses (200 ns pulsewidth, 1 ns risetime), the diodes failed catastrophically at pulse voltages of less than 100 V. We propose a possible mechanism for this anomalous reduction in pulsed breakdown voltage relative to dc breakdown voltage. This instability must be removed so that SiC high-field devices can operate with the same high reliability as silicon power devices.

Neudeck, Philip G.↗

From Diagnosis to Action: An Automated Failure Advisor for Human Deep Space Missions

The major goal of current space system development at NASA is to enable human travel to deep space locations such as Mars and asteroids. At that distance, round trip communication with ground operators may take close to an hour, thus it becomes unfeasible to seek ground operator advice for problems that require immediate attention, either for crew safety or for activities that need to be performed at specific times for the attainment of scientific results. To achieve this goal, major reliance will need to be placed on automation systems capable of aiding the crew in detecting and diagnosing failures, assessing consequences of these failures, and providing guidance in repair activities that may be required. We report here on the most current step in the continuing development of such a system, and that is the addition of a Failure Response Advisor. In simple terms, we have a system in place the Advanced Caution and Warning System (ACAWS) to tell us what happened (failure diagnosis) and what happened because that happened (failure effects). The Failure Response Advisor will tell us what to do about it, how long until something must be done and why its important that something be done and will begin to approach the complex reasoning that is generally required for an optimal approach to automated system health management. This advice is based on the criticality and various timing elements, such as durations of activities and of component repairs, failure effects delay, and other factors. The failure advice is provided to operators (crew and mission controllers) together with the diagnostic and effects information. The operators also have the option to drill down for more information about the failure and the reasons for any suggested priorities.

spacecraft health maintenance↗

Identification of Modeling Approaches To Support Common-Cause Failure Analysis

Experience with applying current guidance and practices for common-cause failure (CCF) mitigation to digital instrumentation and control (I&C) systems has proven problematic, and the regulatory environment has been unpredictable. The impact of CCF vulnerability is to inhibit I&C modernization and, thereby, challenge the long-term sustainability of existing plants. For new plants and advanced reactor concepts, the issue of CCF vulnerability for highly integrated digital I&C systems imposes a design burden resulting in higher costs and increased complexity. The regulatory uncertainty regarding which mitigation strategies are acceptable (e.g., what diversity is needed and how much is sufficient) drives designers to adopt complicated, costly solutions devised for existing plants. The conditions that constrain the transition to digital I&C technology by the U.S. nuclear industry require crosscutting research to resolve uncertainty, demonstrate necessary characteristics, and establish an objective basis for qualification of digital technology for usage in Nuclear Power Plant (NPP) I&C applications. To fulfill this research need, Oak Ridge National Laboratory is conducting an investigation into mitigation of CCF vulnerability for nuclear-qualified applications. The outcome of this research is expected to contribute to a fundamentally sound, comprehensive technical basis for establishing the qualification of digital technology for nuclear power applications. This report documents the investigation of modeling approaches for representing failure of I&C systems. Failure models are used when there is a need to analyze how the probability of success (or failure) of a system depends on the success (or failure) of individual elements. If these failure models are extensible to represent CCF, then they can be employed to support analysis of CCF vulnerabilities and mitigation strategies. Specifically, the research findings documented in this report identify modeling approaches that can be adapted to contribute to the basis for developing systematic methods, quantifiable measures, and objective criteria for evaluating CCF vulnerabilities and mitigation strategies.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Comparison of Functional Models for Use in the Function-Failure Design Method

When failure analysis and prevention, guided by historical design knowledge, are coupled with product design at its conception, shorter design cycles are possible. By decreasing the design time of a product in this manner, design costs are reduced and the product will better suit the customer s needs. Prior work indicates that similar failure modes occur with products (or components) with similar functionality. To capitalize on this finding, a knowledge base of historical failure information linked to functionality is assembled for use by designers. One possible use for this knowledge base is within the Elemental Function-Failure Design Method (EFDM). This design methodology and failure analysis tool begins at conceptual design and keeps the designer cognizant of failures that are likely to occur based on the product s functionality. The EFDM offers potential improvement over current failure analysis methods, such as FMEA, FMECA, and Fault Tree Analysis, because it can be implemented hand in hand with other conceptual design steps and carried throughout a product s design cycle. These other failure analysis methods can only truly be effective after a physical design has been completed. The EFDM however is only as good as the knowledge base that it draws from, and therefore it is of utmost importance to develop a knowledge base that will be suitable for use across a wide spectrum of products. One fundamental question that arises in using the EFDM is: At what level of detail should functional descriptions of components be encoded? This paper explores two approaches to populating a knowledge base with actual failure occurrence information from Bell 206 helicopters. Functional models expressed at various levels of detail are investigated to determine the necessary detail for an applicable knowledge base that can be used by designers in both new designs as well as redesigns. High level and more detailed functional descriptions are derived for each failed component based on NTSB accident reports. To best record this data, standardized functional and failure mode vocabularies are used. Two separate function-failure knowledge bases are then created aid compared. Results indicate that encoding failure data using more detailed functional models allows for a more robust knowledge base. Interestingly however, when applying the EFDM, high level descriptions continue to produce useful results when using the knowledge base generated from the detailed functional models.

Stock, Michael E.↗

STRESS AND FAILURE ANALYSIS OF RAPIDLY ROTATING ASTEROID (29075) 1950 DA

Rozitis et al. recently reported that near-Earth asteroid (29075) 1950 DA, whose bulk density ranges from 1.0 g cm{sup –3} to 2.4 g cm{sup –3}, is a rubble pile and requires a cohesive strength of at least 44-76 Pa to keep from failing due to its fast spin period. Since their technique for giving failure conditions required the averaged stress over the whole volume, it discarded information about the asteroid's failure mode and internal stress condition. This paper develops a finite element model and revisits the stress and failure analysis of 1950 DA. For the modeling, we do not consider material hardening and softening. Under the assumption of an associated flow rule and uniform material distribution, we identify the deformation process of 1950 DA when its constant cohesion reaches the lowest value that keeps its current shape. The results show that to avoid structural failure the internal core requires a cohesive strength of at least 75-85 Pa. It suggests that for the failure mode of this body, the internal core first fails structurally, followed by the surface region. This implies that if cohesion is constant over the whole volume, the equatorial ridge of 1950 DA results from a material flow going outward along the equatorial plane in the internal core, but not from a landslide as has been hypothesized. This has additional implications for the likely density of the interior of the body.

79 ASTRONOMY AND ASTROPHYSICS↗

Reliability of CGA/LGA/HDI Package Board/Assembly (Final Report)

Package manufacturers are now offering commercial-off-the-shelf column grid array (COTS CGA) packaging technologies in high-reliability versions. Understanding the process and quality assurance (QA) indicators for reliability are important for low-risk insertion of these advanced electronics packages. The previous reports, released in January of 2012 and January of 2013, presented package test data, assembly information, and reliability evaluation by thermal cycling for CGA packages with 1752, 1517, 1509, and 1272 inputs/outputs (I/Os) and 1-mm pitch. It presented the thermal cycling (-55C either 100C or 125C) test results for up to 200 cycles. This report presents up to 500 thermal cycles with quality assurance and failure analysis evaluation represented by optical photomicrographs, 2D real time X-ray images, dye-and-pry photomicrographs, and optical/scanning electron Microscopy (SEM) cross-sectional images. The report also presents assembly challenge using reflowing by either vapor phase or rework station of CGA and land grid array (LGA) versions of three high I/O packages both ceramic and plastic configuration. A new test vehicle was designed having high density interconnect (HDI) printed circuit board (PCB) with microvia-in-pad to accommodate both LGA packages as well as a large number of fine pitch ball grid arrays (BGAs). The LGAs either were assembled onto HDI PCB as an LGA or were solder paste print and reflow first to form solder dome on pads before assembly. Both plastic BGAs with 1156 I/O and ceramic LGAs were assembled. It also presented the X-ray inspection results as well as failures due to 200 thermal cycles. Lessons learned on assembly of ceramic LGAs are also presented.

Ghaffaroam. Reza↗

Multiscale Failure Analysis of Laminated Composite Panels Subjected to Blast Loading Using FEAMAC/Explicit

This preliminary report demonstrates the capabilities of the recently developed software implementation that links the Generalized Method of Cells to explicit finite element analysis by extending a previous development which tied the generalized method of cells to implicit finite elements. The multiscale framework, which uses explicit finite elements at the global-scale and the generalized method of cells at the microscale is detailed. This implementation is suitable for both dynamic mechanics problems and static problems exhibiting drastic and sudden changes in material properties, which often encounter convergence issues with commercial implicit solvers. Progressive failure analysis of stiffened and un-stiffened fiber-reinforced laminates subjected to normal blast pressure loads was performed and is used to demonstrate the capabilities of this framework. The focus of this report is to document the development of the software implementation; thus, no comparison between the results of the models and experimental data is drawn. However, the validity of the results are assessed qualitatively through the observation of failure paths, stress contours, and the distribution of system energies.

Pineda, Evan J.↗

Radiation portal monitor data file format for comprehensive background radiation monitoring

Radiation portal monitors (RPMs) are widely used at border security checkpoints to detect the presence of radioactive materials in people, vehicles, and cargo. Typically, RPM detection systems consist of two pillars equipped with gamma and neutron detectors. To improve detection efficiency, RPMs employ techniques such as a limited energy window, dynamic alarm thresholds, and lead shielding. However, without continuous monitoring of background radiation, signal interpretation can be compromised, because environmental factors and mechanical failures can cause fluctuations. Here, we introduce a daily file format that logs gamma background and neutron background radiation levels continuously over a 24 h period; this format is different from traditional formats that record data only when the RPM is active or occupied. The approach enables RPM operators and analysts to (1) identify and diagnose malfunctioning components, (2) adjust system settings to account for dynamic environmental factors, and (3) use the recorded data to characterize outer space phenomena. Continuous background reporting is essential for identifying issues such as faulty connections, voltage divider failures, and errors in background updates. Continuous background reporting also enables the detection of external influences, including nearby X-ray scanners, temperature fluctuations, rainfall, cosmic radiation, and lunar phase changes. These data files are designed to be easily evaluated and parsed using common tools, and a quick review by an expert is often sufficient for problem diagnosis. We anticipate that continuous background radiation monitoring and these new strategies will significantly improve the accuracy and reliability of RPM systems, reducing the rate of false alarms and enhancing overall system performance.

Background radiation monitoring↗

Investigating compression failure mechanisms in composite laminates with a transient fiberglass-epoxy birefringent material

An experimental study is reported in which a nondestructive technique involving the use of a transparent fiberglass-epoxy composite birefringent material has been used to investigate compression failure mechanisms in graphite-epoxy laminates. It is shown that the birefringency and transparency of the fiberglass-epoxy material permits regions of high stress to be located and the mechanisms of local failure propagation to be identified within the laminate. The material may also be useful for studying stress fields and for identifying failure initiation and propagation mechanisms in a wide variety of composite-structure problems.

Shuart, M. J.↗

Failure analysis of aluminum alloy components

Analysis of six service failures in aluminum alloy components which failed in aerospace applications is reported. Identification of fracture surface features from fatigue and overload modes was straightforward, though the specimens were not always in a clean, smear-free condition most suitable for failure analysis. The presence of corrosion products and of chemically attacked or mechanically rubbed areas here hindered precise determination of the cause of crack initiation, which was then indirectly inferred from the scanning electron fractography results. In five failures the crack propagation was by fatigue, though in each case the fatigue crack initiated from a different cause. Some of these causes could be eliminated in future components by better process control. In one failure, the cause was determined to be impact during a crash; the features of impact fracture were distinguished from overload fractures by direct comparisons of the received specimens with laboratory-generated failures.

Johari, O.↗