Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “error bars”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

In-Space Calibration of a Gyro Quadruplet

This work presents a new approach to gyro calibration where, in addition to being used for computing attitude that is needed in the calibration process, the gyro outputs are also used as measurements in a Kalman filter. This work also presents an algorithm for calibrating a quadruplet rather than the customary triad gyro set. In particular, a new misalignment error model is derived for this case. The new calibration algorithm is applied to the EOS-AQUA satellite gyros. The effectiveness of the new algorithm is demonstrated through simulations.

Bar-Itzhack, Itzhack Y.↗

On computing the evolution of temperature for materials under dynamic loading

Modeling and simulation of the dynamic response of materials is important to many applications including the development of armor systems, understanding the safety of explosives, and assessing the crashworthiness of vehicles. Within such applications it is often critical to accurately compute the evolution of the temperature because it is a state variable that affects the kinetics of competing active processes within the material (e.g., dislocation motion, phase transformation, decomposition). Depending on the selection of an independent state variable, e.g. temperature or entropy, the approach for computing temperature is well understood based on the thermodynamic framework attributed to Coleman and Noll. However, different computational codes used for modeling the dynamic response of materials adopt different independent state variables. In this work, two thermodynamically consistent strategies for computing the temperature of a coupled thermodynamic state are compared and implemented into two different Lagrangian computational codes. The equivalence of these two approaches is established through the numerical solutions of several test problems. Finally, the implication of various approximations made to each of these approaches within the literature are assessed in the context of uniaxial stress conditions (split Hopkinson pressure bar experiments) and uniaxial strain conditions (plate impact experiments). Here, it is shown that the temperature rate or energy partition approaches are equivalent when implemented in their complete forms, but that several common simplifying assumptions, that are warranted in the case of uniaxial stress, lead to significant errors in the resulting Hugoniot state for plate impact.

36 MATERIALS SCIENCE↗

A semiclassical correction for quantum mechanical energy levels

We propose a semiclassical method for correcting molecular energy levels obtained from a quantum mechanical variational calculation. A variational calculation gives the energy level (i.e., eigenvalue) as the expectation value of the molecular Hamiltonian <{phi}|H|{phi}>, where |{phi}> is the trial wave function. The true (i.e., exact) eigenvalue E can thus be expressed as this variational result plus a correction, i.e., E=<{phi}|H|{phi}>+{Delta}E, the correction being due to the lack of exactness of the trial wave function. A formally exact expression for {Delta}E is usually given (via Loewdin partitioning methodology) in terms of the Greens function of the Hamiltonian projected onto the orthogonal complement of |{phi}>. Formal treatment of this expression (using Brillouin-Wigner perturbation theory to infinite order) leads to an expression for {Delta}E that involves matrix elements of the Greens function for the unprojected, i.e., full molecular Hamiltonian, which can then be approximated semiclassically. (Specifically, the Greens function is expressed as the Fourier transform of the quantum mechanical time evolution operator, e{sup -}iHt/({h_bar}/2{pi}), which in turn is approximated by using an initial value representation of semiclassical theory.) Calculations for several test problems (a one dimensional quartic potential, and vibrational energy levels of H{sub 2}O and H{sub 2}CO) clearly support our proposition that the error in the total eigenvalue E arises solely due to the semiclassical error in approximating {Delta}E, which is usually a small fraction of the total energy E itself.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Studies of sigma(e+ e- to hadrons) at BaBar using Initial State Radiation (ISR)

We present a review of BaBar results on e{sup +}e{sup -} {yields} hadrons using the initial state radiation technique. Cross sections over the {radical}s range from threshold to 4-5 GeV, with very small point-to-point systematic errors, are presented for the {pi}{sup +}{pi}{sup -}{pi}{sup 0}, 2({pi}{sup +}{pi}{sup -}), 2(K{sup +}K{sup -}), 3({pi}{sup +}{pi}{sup -}), 2({pi}{sup +}{pi}{sup -})2{pi}{sup 0}, 2({pi}{sup +}{pi}{sup -})K{sup +}K{sup -}, and p{bar p} final states. The preliminary results of e{sup +}e{sup -} {yields} K{sup +}K{sup -}{pi}{sup +}{pi}{sup -} and e{sup +}e{sup -} {yields} K{sup +}K{sup -}{pi}{sup 0}{pi}{sup 0} cross sections are also presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Statistical determination of bulk flow motions

We present here a new parameterization for the bulk motions of galaxies and clusters (in the linear regime) that can be measured statistically from the shape and amplitude of the two-dimensional two-point correlation function. We further propose the one-dimensional velocity dispersion (v{sub p}) of the bulk flow as a complementary measure of redshift-space distortions, which is model-independent and not dependent on the normalisation method. As a demonstration, we have applied our new methodology to the C4 cluster catalogue constructed from Data Release Three (DR3) of the Sloan Digital Sky Survey. We find v{sub p} = 270{sup +433} km/s (also consistent with v{sub p} = 0) for this cluster sample (at z-bar = 0.1), which is in agreement with that predicted for a WMAP5-normalised ΛCDM model (i.e., v{sub p}(ΛCDM) = 203 km/s). This measurement does not lend support to recent claims of excessive bulk motions ( ≅ 1000 km/s) which appear in conflict with ΛCDM, although our large statistical error cannot rule them out. From the measured coherent evolution of v{sub p}, we develop a technique to re-construct the perturbed potential, as well as estimating the unbiased matter density fluctuations and scale-independent bias.

79 ASTRONOMY AND ASTROPHYSICS↗

Quartz conditioning crystal for X-ray rocking curve topography

A large α-quartz crystal designed to condition the monochromatic beam at beamline 1-BM of the Advanced Photon Source is presented. The purpose of this crystal was to provide a precise match to the Bragg angle of quartz crystals that are commonly used to make analyzers for plasma diagnostics. In order to characterize these analyzers, area detectors need to be positioned at distances from the analyzer at upwards of 1000 mm. As a result of this precise matching, a Bragg-reflected beam from such an analyzer is precisely parallel to the beam incident on the conditioning crystal. This situation alleviates the need to adjust the position of the area detector as the distance between the analyzer and the area detector is varied. That is, there is no need to account for vertical displacement of the diffracted-beam image as a function of this distance. Additionally, verification that the analyzer is set to the correct Bragg reflection is obtained by scanning this distance, because only for a spurious reflection will there be a vertical displacement. This is a very useful check. To commission the conditioning crystal, diffraction from a high-quality flat quartz crystal was mapped using a CCD. Bragg diffraction from the 40$\bar{40}$ reflection at 8.5 keV was studied over an area of 23 × 31 mm. The theoretical Darwin width of the flat sample in this case was 4.7 µrad. An FWHM value near 6 µrad was measured over almost the entire mapped area. These data demonstrate that the resolution function for this four-crystal arrangement is ~4 µrad. Data are also presented for a 0.1 mm-thick α-quartz wafer pressed into a concave form, having a nominal radius of 500 mm and intended for use as an analyzer. Because analyzers are bent crystals, diffraction occurs in narrow bands. When a multiple exposure is made as a function of rocking angle a striped pattern is obtained, which is commonly referred to as a zebra-stripe pattern. A series of zebra stripes from the 30$\bar{33}$ Bragg reflection of the bent wafer over its 25 mm-diameter area were recorded on a CCD. The zebra-stripe pattern was analyzed to show a uniform bending to a radius of 497.0 ± 0.3 mm, in support of the nominal value. An r.m.s. slope error of 7 µrad was also obtained from this analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Atmospheric Calibration for Cassini Radio Science

The signals from the Cassini spacecraft that will be affected by delay fluctuations in the Earth's atmosphere. These fluctuations are dominated by water vapor in the troposphere, and in the case of Gravitaional Wave Experiment (GWE), they are likely to be a limiting error source. A passive remote sensing system, centered around a water vapor radiometer (WVR), has been developed to provide calibrations of water vapor fluctuations during radio science experiments.

Cassini Cassini radio GWE gravity wave experiment ↗

Technical Note: Immunohistochemical evaluation of mouse brain irradiation targeting accuracy with 3D-printed immobilization device

Purpose: Small animal immobilization devices facilitate positioning of animals for reproducible imaging and accurate focal radiation therapy. In this study, the authors demonstrate the use of three-dimensional (3D) printing technology to fabricate a custom-designed mouse head restraint. The authors evaluate the accuracy of this device for the purpose of mouse brain irradiation. Methods: A mouse head holder was designed for a microCT couch using CAD software and printed in an acrylic based material. Ten mice received half-brain radiation while positioned in the 3D-printed head holder. Animal placement was achieved using on-board image guidance and computerized asymmetric collimators. To evaluate the precision of beam localization for half-brain irradiation, mice were sacrificed approximately 30 min after treatment and brain sections were stained for γ-H2AX, a marker for DNA breaks. The distance and angle of the γ-H2AX radiation beam border to longitudinal fissure were measured on histological samples. Animals were monitored for any possible trauma from the device. Results: Visualization of the radiation beam on ex vivo brain sections with γ-H2AX immunohistochemical staining showed a sharp radiation field within the tissue. Measurements showed a mean irradiation targeting error of 0.14 ± 0.09 mm (standard deviation). Rotation between the beam axis and mouse head was 1.2° ± 1.0° (standard deviation). The immobilization device was easily adjusted to accommodate different sizes of mice. No signs of trauma to the mice were observed from the use of tooth block and ear bars. Conclusions: The authors designed and built a novel 3D-printed mouse head holder with many desired features for accurate and reproducible radiation targeting. The 3D printing technology was found to be practical and economical for producing a small animal imaging and radiation restraint device and allows for customization for study specific needs.

60 APPLIED LIFE SCIENCES↗

Precision measurement of the top quark mass in the lepton + jets channel using a matrix element method with Quasi-Monte Carlo integration

This thesis presents a measurement of the top quark mass obtained from p$\bar{p}$ collisions at √s = 1.96 TeV at the Fermilab Tevatron using the CDF II detector. The measurement uses a matrix element integration method to calculate a t$\bar{t}$ likelihood, employing a Quasi-Monte Carlo integration, which enables us to take into account effects due to finite detector angular resolution and quark mass effects. We calculate a t$\bar{t}$ likelihood as a 2-D function of the top pole mass m t and Δ JES , where Δ JES parameterizes the uncertainty in our knowledge of the jet energy scale; it is a shift applied to all jet energies in units of the jet-dependent systematic error. By introducing Δ JES into the likelihood, we can use the information contained in W boson decays to constrain Δ JES and reduce error due to this uncertainty. We use a neural network discriminant to identify events likely to be background, and apply a cut on the peak value of individual event likelihoods to reduce the effect of badly reconstructed events. This measurement uses a total of 4.3 fb -1 of integrated luminosity, requiring events with a lepton, large E T , and exactly four high-energy jets in the pseudorapidity range |η| < 2.0, of which at least one must be tagged as coming from a b quark. In total, we observe 738 events before and 630 events after applying the likelihood cut, and measure m t = 172.6 ± 0.9 (stat.) ± 0.7 (JES) ± 1.1 (syst.) GeV/c 2 , or m t = 172.6 ± 1.6 (tot.) GeV/c 2 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Branching Fraction Measurement of B to omega l nu decays

We present a measurement of the B{sup +} {yields} {omega}{ell}{sup +}{nu} branching fraction based on a sample of 467 million B{bar B} pairs recorded by the BABAR detector at the SLAC PEP-II e{sup +}e{sup -} collider. We observe 1041 {+-} 133 signal decays, corresponding to a branching fraction of {Beta}(B{sup +} {yields} {omega}{ell}{sup +}{nu}) = (1.15 {+-} 0.15 {+-} 0.12) x 10{sup -4}, where the first error is statistical and the second is systematic. The dependence of the decay rate on q{sup 2}, the momentum transfer squared to the lepton system, is compared to QCD predictions of the form factors based on a quark model and light-cone sum rules.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A measurement of CMB cluster lensing with SPT and DES year 1 data

Clusters of galaxies gravitationally lens the cosmic microwave background (CMB) radiation, resulting in a distinct imprint in the CMB on arcminute scales. Measurement of this effect offers a promising way to constrain the masses of galaxy clusters, particularly those at high redshift. We use CMB maps from the South Pole Telescope Sunyaev-Zel'dovich (SZ) survey to measure the CMB lensing signal around galaxy clusters identified in optical imaging from first year observations of the Dark Energy Survey. The cluster catalog used in this analysis contains 3697 members with mean redshift of $\bar{z} = 0.45$. We detect lensing of the CMB by the galaxy clusters at $8.1\sigma$ significance. Using the measured lensing signal, we constrain the amplitude of the relation between cluster mass and optical richness to roughly $17\%$ precision, finding good agreement with recent constraints obtained with galaxy lensing. The error budget is dominated by statistical noise but includes significant contributions from systematic biases due to the thermal SZ effect and cluster miscentering.

79 ASTRONOMY AND ASTROPHYSICS↗

Observation and study of baryonic B decays: B -> D(*) p pbar, D(*) p pbar pi, and D(*) p pbar pi pi

We present a study of ten B-meson decays to a D{sup (*)}, a proton-antiproton pair, and a system of up to two pions using BABAR's data set of 455 x 10{sup 6} B{bar B} pairs. Four of the modes {bar B}{sup 0} {yields} D{sup 0}p{bar p}, {bar B}{sup 0} {yields} D*{sup 0}p{bar p}, {bar B}{sup 0} {yields} D{sup +}p{bar p}{pi}{sup -}, {bar B}{sup 0} {yields} D{sup ast+}p{bar p}{pi}{sup -} are studied with improved statistics compared to previous measurements; six of the modes (B{sup -} {yields} D{sup 0}p{bar p}{pi}{sup -}, B{sup -} {yields} D*{sup 0}p{bar p}{pi}{sup -}, {bar B}{sup 0} {yields} D{sup 0}p{bar p}{pi}{sup -}{pi}{sup +}, {bar B}{sup 0} {yields} D*{sup 0}p{bar p}{pi}{sup -}{pi}{sup +}, B{sup -} {yields} D{sup +}p{bar p}{pi}{sup -}{pi}{sup -}, B{sup -} {yields} D{sup ast+}p{bar p}{pi}{sup -}{pi}{sup -}) are first observations. The branching fractions for 3- and 5-body decays are suppressed compared to 4-body decays. Kinematic distributions for 3-body decays show non-overlapping threshold enhancements in m(p{bar p}) and m(D{sup (*)0}p) in the Dalitz plots. For 4-body decays, m(p{pi}{sup -}) mass projections show a narrow peak with mass and full width of (1497.4 {+-} 3.0 {+-} 0.9)MeV/c{sup 2} and (47 {+-} 12 {+-} 4)MeV/c{sup 2}, respectively, where the first (second) errors are statistical (systematic). For 5-body decays, mass projections are similar to phase space expectations. All results are preliminary.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SPACE VELOCITIES OF SOUTHERN GLOBULAR CLUSTERS. VII. NGC 6397, NGC 6626 (M28), AND NGC 6656 (M22)

We have measured the absolute proper motions of globular clusters NGC 6397, NGC 6626 (M22), and NGC 6656 (M28) as part of our ongoing Southern Proper-Motion Program. The reference system is the ICRS via Hipparcos stars for these three low-Galactic-latitude clusters. Formal errors range between {approx}0.3 and 0.7 mas yr{sup -1}. Notable is the result for NGC 6397, which differs by 2.5 mas yr{sup -1} from two Hubble Space Telescope determinations while agreeing with previous ground-based ones. We determine orbits for all three clusters in an axisymmetric and barred model of the Galaxy and discuss these in the context of globular-cluster formation. M22 is a well-known cluster with an iron abundance spread; such clusters are now believed to have formed in massive parent systems that can retain ejecta of core-collapsed supernovae. We find that the five currently accepted globular clusters with iron/calcium abundance spread show orbits unrelated to each other, thus suggesting at least five independent, massive progenitors that have contributed to the build-up of the Milky-Way halo.

79 ASTRONOMY AND ASTROPHYSICS↗

Physical Properties of the Satellites of Neptune

Spectrophotometric studies of Triton suggest a surface covered in part by solid methane. Nitrogen is suspected on the basis of a single spectral band, but this material, if present, must be in a condensed state. Liquid nitrogen covering part of Triton to a depth of a few tens of centimeter can satisfy the spectral data so far available. If condensed nitrogen occurs on Triton, the satellite has an atmosphere largely of N2 (pressure approximately 0.1 bar), with CH4 as a minor constituent. The reddish hue of Triton's surface may result from photochemical derivatives of the methane and nitrogen, as in the case of Titan. The radius of Triton has been determined by indirect means to be 1750 km, but there may be a large systemmatic error in this value. If the mean density is approximately 2-3 g/cubic cm. the mass derived from astrometric observations is in error. There is no information on physical properties of Nereid. A third suspected satellite was not confirmed.

Cruikshank, D. P.↗

Comprehensive evaluation of attitude and orbit estimation using real earth magnetic field data

A single, augmented extended Kalman filter (EKF) which simultaneously and autonomously estimates spacecraft attitude and orbit was developed and tested with simulated and real magnetometer and rate data. Since the earth's magnetic field is a function of time and position, and since time is accurately known, the differences between the computed and measured magnetic field components, as measured by the magnetometers throughout the entire spacecraft's orbit, are a function of orbit and attitude errors. These differences can be used to estimate the orbit and attitude. The test results of the EKF with magnetometer and gyro data from three NASA satellites are presented and evaluated.

Deutschmann, Julie↗

Integration and evaluation of a needle-positioning robot with volumetric microcomputed tomography image guidance for small animal stereotactic interventions

Purpose: Preclinical research protocols often require insertion of needles to specific targets within small animal brains. To target biologically relevant locations in rodent brains more effectively, a robotic device has been developed that is capable of positioning a needle along oblique trajectories through a single burr hole in the skull under volumetric microcomputed tomography (micro-CT) guidance. Methods: An x-ray compatible stereotactic frame secures the head throughout the procedure using a bite bar, nose clamp, and ear bars. CT-to-robot registration enables structures identified in the image to be mapped to physical coordinates in the brain. Registration is accomplished by injecting a barium sulfate contrast agent as the robot withdraws the needle from predefined points in a phantom. Registration accuracy is affected by the robot-positioning error and is assessed by measuring the surface registration error for the fiducial and target needle tracks (FRE and TRE). This system was demonstrated in situ by injecting 200 {mu}m tungsten beads into rat brains along oblique trajectories through a single burr hole on the top of the skull under micro-CT image guidance. Postintervention micro-CT images of each skull were registered with preintervention high-field magnetic resonance images of the brain to infer the anatomical locations of the beads. Results: Registration using four fiducial needle tracks and one target track produced a FRE and a TRE of 96 and 210 {mu}m, respectively. Evaluation with tissue-mimicking gelatin phantoms showed that locations could be targeted with a mean error of 154{+-}113 {mu}m. Conclusions: The integration of a robotic needle-positioning device with volumetric micro-CT image guidance should increase the accuracy and reduce the invasiveness of stereotactic needle interventions in small animals.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Measurement of CP observables in B{sup {+-}{yields}D}{sub CP}K{sup {+-}}decays and constraints on the CKM angle {gamma}

Using the entire sample of 467x10{sup 6} {Upsilon}(4S){yields}BB decays collected with the BABAR detector at the PEP-II asymmetric-energy B factory at the SLAC National Accelerator Laboratory, we perform an analysis of B{sup {+-}}{yields}DK{sup {+-}}decays, using decay modes in which the neutral D meson decays to either CP-eigenstates or non-CP-eigenstates. We measure the partial decay rate charge asymmetries for CP-even and CP-odd D final states to be A{sub CP+}=0.25{+-}0.06{+-}0.02 and A{sub CP-}=-0.09{+-}0.07{+-}0.02, respectively, where the first error is the statistical and the second is the systematic uncertainty. The parameter A{sub CP+} is different from zero with a significance of 3.6 standard deviations, constituting evidence for direct CP violation. We also measure the ratios of the charged-averaged B partial decay rates in CP and non-CP decays, R{sub CP+}=1.18{+-}0.09{+-}0.05 and R{sub CP-}=1.07{+-}0.08{+-}0.04. We infer frequentist confidence intervals for the angle {gamma} of the unitarity triangle, for the strong phase difference {delta}{sub B}, and for the amplitude ratio r{sub B}, which are related to the B{sup -}{yields}DK{sup -} decay amplitude by r{sub B}e{sup i({delta}{sub B}-{gamma})}=A(B{sup -}{yields}D{sup 0}K{sup -})/A(B{sup -}{yields}D{sup 0}K{sup -}). Including statistical and systematic uncertainties, we obtain 0.24<r{sub B}<0.45 (0.06<r{sub B}<0.51) and, modulo 180 deg., 11.3 deg. <{gamma}<22.7 deg. or 80.8 deg. <{gamma}<99.2 deg. or 157.3 deg. <{gamma}<168.7 deg. (7.0 deg. <{gamma}<173.0 deg.) at the 68% (95%) confidence level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Hexapod Robot

The project I am working on at NASA-Johnson Space Center in Houston, TX is a hexapod robot. This project was started by various engineers at the Trick Lab. The goal of this project is to have the hexapod track a yellow ball or possibly another object from left to right and up/down. The purpose is to have it track an object like a real creature. The project will consist of using software and hardware. This project started with a hexapod robot which uses a senor bar to track a yellow ball but with a limited field of vision. The sensor bar acts as the robots "head." Two servos will be added to the hexapod to create flexion and extension of the head. The neck and head servos will have to be programmed to be added to the original memory map of the existing servos. I will be using preexisting code. The main programming language that will be used to add to the preexisting code is C++. The trick modeling and simulation software will also be used in the process to improve its tracking and movement. This project will use a trial and error approach, basically seeing what works and what does not. The first step is to initially understand how the hexapod works. To get a general understanding of how the hexapod maneuvers and plan on how to had a neck and head servo which works with the rest of the body. The second step would be configuring the head and neck servos with the leg servos. During this step, limits will be programmed specifically for the each servo. By doing this, the servo is limited to how far it can rotate both clockwise and counterclockwise and this is to prevent hardware damage. The hexapod will have two modes in which it works in. The first mode will be if the sensor bar does not detect an object. If the object it is programmed to look for is not in its view it will automatically scan from left to right 3 times then up and down once. The second mode will be if the sensor bar does detect the object. In this mode the hexapod will track the object from left to right or up and down. The hexapod will eventually be able to track the object moving its head and body in sync with on another and being able to rotate its body at 360 degrees. This is the plans and possible end results for the hexapod robot I will be working on during my summer internship at NASA Johnson Space Center. Since working on the hexapod project I have gained an increase interest in robotics. I enjoy the process of critical thinking. Also will working on this project I was challenged in a way that made more passionate to strive even more to become an engineer. I've learned that asking questions is an important part of the learning process. Also I learn that much more is accomplished when teamwork is applied.

Begody, Ericka↗