Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “energy optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Risks and Benefits of Pressurized Water Reactor Coupling to Energy Storage and Water Desalination

This research explored potential options to improve nuclear pressurized water reactors’ (PWRs) operational flexibility through integration with thermal energy storage (TES) and water desalination technologies. Benefits and challenges of TES technologies were reviewed, which includes sensible heat storage systems, latent heat storage systems, and thermochemical storage systems. Water desalination technologies were reviewed and compared, which includes multi-stage flash, reverse osmosis, and multi-effect distillation. The multi-effect distillation technology was selected to be coupled with a generic PWR. Risk of this cogeneration was quantified using the probabilistic risk assessment (PRA) methodology. Results suggest that nuclear-desalination cogeneration can be done safely because the additional risk to the PWR is trivial, and even in certain cases the PWR risk is decreased. This cogeneration operation is expected to improve efficiency of thermal utilization and the nuclear plant’s revenues. In summary, this study supports the potential of nuclear-desalination cogeneration systems to address water scarcity while optimizing nuclear energy use and managing safety.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Estimating National-Scale Wind Potential Using Spatially Explicit Turbine Layout Optimization

National renewable energy potential assessments play a broad and critical role in analysis of the clean energy transition by providing foundational estimates of developable clean resources. Common to all past wind potential assessments is an assumption that wraps the complexity of wind plant layout (arrangement of turbines) into a single metric known as capacity density, or rated power capacity per unit of land area. Quite often, a singular capacity density or rotor-diameter driven capacity density is used in wind potential assessments across broad geographies despite the complexities of local drivers. Here, we present a new wind technical potential assessment for the United States, leveraging a spatial optimization approach in lieu of the traditional uniform capacity density. The optimization approach is a spatially explicit method for determining the potential locations of individual wind turbines-taking into account the turbine configuration, plant economics and losses, wind resource, and siting considerations. Our approach accounts for the interactions between wind technology design, wind plant layout, and the vast array of regulatory, land use and infrastructure conflicts with wind development. Our results highlight the potential ability of larger turbines to enable increased wind capacity, up to a point, and increased generation when siting turbines in and around spatial constraints; moreover, they demonstrate and capture the LCOE benefit of relatively lower capacity densities and reduced wake losses when land is relatively abundant. These insights provide foundational knowledge for the wind sector as it develops and pursues future turbine models and as wind energy markets expand in zero-carbon futures. Further, when applied in capacity expansion models, supply curves developed by these methods can provide detailed local insights about where wind turbines might be deployed in and among known siting constraints for those regions where wind energy is determined to be economic, providing critical nuance to local decision-makers and stakeholders.

17 WIND ENERGY↗

Optimal scheduling for profit maximization of energy storage merchants considering market impact based on dynamic programming

This paper analyzes how electricity merchants' market impact affects merchants' profit. Energy storage has long been studied for its role in maximizing profit, and merchant decisions are assumed to have no impact on market prices. However, the trading decisions of large-scale energy storage merchants (e.g., pumped storage hydro) will affect the market prices. This paper employs dynamic programming theory to investigate merchants' optimal economic dispatch considering the market impact and physical characteristics of storage systems. Our findings show that the State-of-Charge (SOC) based analytical solution significantly facilitates energy storage merchants' decision-making. The SOC range is segmented into three regions by two optimal SOC reference points, which depend on the available energy in storage, given prices, and market impact. By comparing the current storage SOC with the reference points, the merchant can get the corresponding optimal actions. We analytically show that if the merchant neglects the market impact on the power market, she will exaggerate her expected profit when the price-taker and price-maker merchants have the same generating and pumping upper limits offered to Independent System Operators (ISOs). Furthermore, the profit-maximizing merchant must, therefore, assay to balance the trade-off correctly between the intensity of market impact and the dispatched power. Our findings are verified by numerical simulation, and results demonstrate the ramifications for electricity merchants in energy arbitrage decisions.

25 ENERGY STORAGE↗

Transmission-distribution long-term volt-var planning considering reactive power support capability of distributed PV

High penetration of grid-edge, inverter-based photovoltaic (PV) can cause significant voltage fluctuations not only at the distribution but also at the sub-transmission levels due to PV output intermittency. Traditional reactive power planning approaches do not consider intermittency, nor the possibility of coordinating the control of existing and future volt-ampere reactive resources. This paper proposes a reactive power planning tool for sub-transmission systems to mitigate voltage violations and fluctuations caused by high PV penetration and intermittency with a minimum investment cost. The planning tool coordinates with an optimization-based volt-var operational tool for: a) modeling the coordination of all existing var assets in both sub-transmission and distribution systems to reduce the need of new equipment, and b)selecting a set of scenarios with voltage violations, derived from PV intermittency c) testing the final investment decision. The tool obtains an investment need for each intermittency scenario with a proposed optimal power-flow framework with efficient techniques to handle a high number of discrete variables. Two options are provided for final planning decision: i) a conservative direct combination of investment need solutions and ii) a machine learning-based selection of representative investment needs at most time steps. The final investment decision options are verified using a realistic large-scale sub-transmission system and 5-minute PV and load data. The results show a significant voltage performance improvement with a lower investment cost for additional var equipment compared to conventional approaches.

14 SOLAR ENERGY↗

Release a public version of HERON (HERON 2.0) with improved algorithms for the treatment of energy storage

Integrated energy systems (IESs) are essential for decarbonizing electricity and industrial sectors and fully exploiting these systems requires sophisticated planning, scheduling, and dispatching tools to maximize their socio-economic benefits. The Holistic Energy Resource Optimization Network (HERON) is a generic software plugin for the Risk Analysis Virtual Environment (RAVEN) to perform stochastic technoeconomic analysis of IES with economic drivers. This report summarizes the updates made to HERON 2.0. Particularly, we demonstrate one of the added features, Function-based Control Mechanics, by comparing a price-based dispatch strategy with the original perfect foresight baselines. Our case studies successfully demonstrate that the model is capable to incorporate artificial control algorithm into the dispatch of IES components. In addition, our results from the price-based strategy indicate that the control strategies of IES components are key to the economic and temporal performance of our model; therefore, more sophisticated dispatch strategies are required to improve the model performance.

25 ENERGY STORAGE↗

TEAL Output Visualization

Tool for Economic Analysis (TEAL) is an open-source economics calculation package written and maintained by Idaho National Laboratory (INL). As a plugin of the Risk Analysis Virtual ENvironment (RAVEN), TEAL provides economics analysis models to RAVEN workflow users. In addition, TEAL is used in other RAVEN plugins such as LOGOS and the Holistic Energy Resource Optimization Network (HERON) to complement other analyses with economic calculations. This report documents the efforts in developing the capability of TEAL output visualization for users to better understand and investigate TEAL simulation results. In the past, outputs (e.g., various cash flows) were generated and printed to screen. According to the need and purpose for visualization, users can select various bar charts and donut charts to visualize the cash flows including inflows, outflows, and net cash flows in each year or in a selected time range, in addition to observing data stored in comma-separated value files (CSVs). The visualization capability is flexible and user-friendly by introducing several user-defined parameters, for instance, the start and the end project year of interest and the type of colors to be assigned to the cash flows.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Beyond Price-Taker: Multiscale Optimization of a Wind-Battery Integrated Energy System within the Wholesale Electricity Market

This work presents the optimization of a wind-battery IES using the multiscale optimization framework proposed in our previous work to quantify errors from the price-taker assumption. The framework, built over Prescient (an open-source package for solving production cost models), is applied to the RTS-GMLC dataset, an open-source dataset that is representative of the southwest U.S. wholesale electricity market. The framework provides detailed bidding, market clearing, and control processes of an IES, and it can quantify how the IES interacts with the market. In this work, we use the retrofit of a wind farm with a battery storage system as an example to show the difference in the market outcomes and revenues obtained from both price-taker and multiscale optimization approaches. Our work goes beyond price-taker and deep dives into quantifying IES-market interaction in optimizing IES. This framework enables users to explore how different design and operation decisions of energy systems interact with the market and provides a more accurate evaluation than the price-taker assumption.

Chen, Xinhe↗

Distributed Energy Management for Networked Microgrids with Hardware-in-the-Loop Validation

For the cooperative operation of networked microgrids, a distributed energy management considering network operational objectives and constraints is proposed in this work. Considering various ownership and privacy requirements of microgrids, utility directly interfaced distributed energy resources (DERs) and demand response, a distributed optimization is proposed for obtaining optimal network operational objectives with constraints satisfied through iteratively updated price signals. The alternating direction method of multipliers (ADMM) algorithm is utilized to solve the formulated distributed optimization. The proposed distributed energy management provides microgrids, utility-directly interfaced DERs and responsive demands the opportunity of contributing to better network operational objectives while preserving their privacy and autonomy. Results of numerical simulation using a networked microgrids system consisting of several microgrids, utility directly interfaced DERs and responsive demands validate the soundness and accuracy of the proposed distributed energy management. The proposed method is further tested on a practical two-microgrid system located in Adjuntas, Puerto Rico, and the applicability of the proposed strategy is validated through hardware-in-the-loop (HIL) testing.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Systematic Review and Integrated Approach to Modeling of Aging Utility Scale PV Systems

The growing deployment of utility-scale photovoltaic (PV) systems has increased the importance of techno-economic modeling operational photovoltaic (PV) systems for predicting energy yield, optimizing asset management, and informing financial decisions. Through a systematic review of literature and current industry practices, we review the different common modeling practices of a system's configuration and age, performance and degradation, operation and maintenance (O&M), while also focusing on specific considerations for repowering, revamping, and decommissioning. Building on the synthesis, we develop a structured framework for techno-economic modeling of operating PV systems that integrate performance and degradation analysis, a decommissioning and repowering cost model that estimates the system's end-of-life costs to reduce uncertainty quantifications and improve consistency across the sector. This research contributes to improved modeling methodologies and potentially to reduced financial performance requirements by providing practitioners with input resources and practical approaches to estimate performance, degradation, and costs associated with continued operation, revamping, repowering, or decommissioning decisions.

14 SOLAR ENERGY↗

Field Validation of a Building Operating System Platform

The U.S General Services Administration's (GSA's) Green Proving Ground program, in partnership with the National Renewable Energy Laboratory. completed a large pilot study of an Energy Management Information Systems (EMIS) with Automated System Optimization (ASO). Four test bed facilities, each with different building characteristics and systems, were chosen for the implementation of cloud-based EMIS with ASO. Depending on functionality, this tool can be extremely effective in energy management and energy optimization in buildings. The capabilities evaluated in the pilot ranged from energy savings and energy consumption predictions to evaluations of user acceptance, operability, and ease of installation. This report presents the methodology, lessons learned and best practices, and deployment recommendations for the GSA's portfolio of commercial office space, comprising more than 8,500 properties.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fine‐Tuning Alkyl Chains on Quinoxaline Nonfullerene Acceptors Enables High‐Efficiency Ternary Organic Solar Cells with Optimizing Molecular Stacking and Reducing Energy Loss

Abstract Material design of guest acceptor is always a big challenge for improving the efficiency of ternary organic solar cells (OSCs). Here, a pair of isomeric nonfullerene acceptors based on quinoxaline core, Qx–p‐C 7 H 8 O and Qx–m‐C 7 H 8 O, is designed and synthesized. By moving the alkoxy chain attached on side phenyl frommeta‐position topara‐position, both π–π stacking distance and crystallinity are enhanced simultaneously. They obtain the uplifted lowest unoccupied molecular orbital level. Compared to Qx–m‐C 7 H 8 O, Qx–p‐C 7 H 8 O exhibits wider absorption spectrum and higher extinction coefficient. Using D18‐Cl:N3 as host materials, the addition of guest acceptor Qx–p‐C 7 H 8 O significantly improves the power conversion efficiency (PCE) from 17.61% to 18.49% because of higher open‐circuit voltage (0.875 V) and short‐circuit current density (27.85 mA cm −2 ). This can be attributed to the faster exciton dissociation, more balanced carrier mobility, fine fiber morphology, and lower energy loss in the ternary devices. However, Qx–m‐C 7 H 8 O‐based ternary device achieves relatively low PCE of 17.17% because this device shows extremely low electron mobility. The results indicate that molecular stacking, film morphology, etc., can be effectively modulated by fine‐tuning the side chains of guest materials, which may be an effective design rule for further improving the PCE of OSCs.

Chemistry↗

An encoder–decoder LSTM-based EMPC framework applied to a building HVAC system

Numerous studies have demonstrated the benefit of economic model predictive control (EMPC) applied to building heating, ventilation, and air conditioning (HVAC) systems. However, the construction and training of predictive models for building HVAC systems are widely recognized as a key technological barrier preventing large-scale adoption of EMPC for buildings. In this work, an encoder–decoder long short-term memory-based EMPC framework is developed. The key advantage of the approach is that a model may be automatically generated from a list of inputs and outputs. From the definition of inputs and outputs, the constructed model may be trained and automatically embedded into the EMPC framework for real-time estimation and control. The overall end-to-end EMPC framework from model training to on-line estimation and control are described. To this end, the encoder–decoder model provides a natural framework for state estimation (encoder), which is required to provide an initial condition for the predictive model of EMPC (decoder). Closed-loop simulations using EnergyPlus are performed to demonstrate the approach. The simulated closed-loop system consists of a building zone from a multi-zone building, which is served by an air handling unit-variable air volume HVAC system. For the HVAC example considered, the trained encoder–decoder model can predict the indoor air temperature and HVAC sensible cooling rate of a building zone over a two-day horizon with high accuracy. Overall, we find that considering a time-of-use electric rate structure, the EMPC, which manipulates the zone temperature setpoint, can reduce the HVAC power consumption cost relative to keeping the zone temperature setpoint at its maximum value (i.e., minimum energy approach).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Computational design of isotropic and anisotropic ultralow thermal conductivity polymer foams

Current state-of-the-art commercial polymer thermal insulation foam exhibits a thermal conductivity of 24 mW·m -1 ·K -1 (equivalently thermal resistivity of R-6/in.), similar to that of static air. To further optimize building energy efficiency, achieving even lower thermal conductivity is needed, which is, however, highly challenging. This paper presents computational evidence that demonstrates the feasibility of achieving an ultra-low thermal conductivity of less than 14.4 mW·m -1 ·K -1 (equivalently R-10/in.) using isotropic and anisotropic foam cell designs. For the isotropic design, we have identified analytical effective medium approximation (EMA) models within the accuracy of ±5% as finite element analysis (FEA) in predicting the effective thermal conductivity of foams with various porosities and filler gases. For the anisotropic design, we have developed and validated new EMA models against FEA in predicting the effective thermal conductivity of general anisotropic cuboids and Voronoi foams. For both isotropic and anisotropic designs, the design spaces for 18, 16, and 14.4 mW·m -1 ·K -1 (equivalently R-8, R-9 and R-10/in.) using various filler gases are obtained. It is found that polymer foams can be improved to achieve ultralow thermal conductivity by reducing CO 2 concentration, reducing radiation, increasing porosity, and using anisotropic pore geometry. In conclusion, these findings contribute to the development of highly efficient thermal insulation materials, enhancing building energy efficiency and promoting sustainable construction practices.

42 ENGINEERING↗

Flow Instabilities in boiling channels and their suppression methodologies—A review

Small modular reactors (SMRs) are gaining significant attention as a promising solution for clean and sustainable nuclear-power generation. However, the operation of SMRs is subject to various challenges, including two-phase flow instabilities. Flow instability has the potential to trigger flow-induced vibration and cyclic fluctuations in local thermal stress. These instabilities frequently manifest because of the complex interplay among a multitude of factors, encompassing thermal-hydraulic conditions, the geometric configuration of the steam generator, and operational parameters. These conditions could subsequently lead to premature critical heat flux, equipment malfunctions, and other safety concerns. Here, the endeavor to address steam-generator flow instabilities is of utmost importance in augmenting the sustainability and efficiency of contemporary energy production. This study offers a comprehensive review of instabilities in two-phase flow, with a particular focus on the influential factors impacting the stability of flow boiling. Furthermore, it delves into the processes of identifying, characterizing, and ameliorating these instabilities, emphasizing pivotal findings, methodologies employed, and avenues for prospective research. The primary parameters of concern encompass the efficient transfer of thermal energy, the optimization of mass-flow rates, and the establishment of favorable boundary conditions, all in the context of steam generator design to alleviate instability for water-cooled SMRs. These discernments bear substantial ramifications for enhancing reactor performance and ensuring operational safety.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Automated and efficient local adaptive regression for principal component-based reduced-order modeling of turbulent reacting flows

Principal Component Analysis can be used to reduce the cost of Computational Fluid Dynamics simulations of turbulent reacting flows by reducing the dimensionality of the transported variables through projection of the thermochemical state onto a lower-dimensional manifold. However, because of the nonlinearity of the principal component source terms, nonlinear regression techniques must be utilized for the source terms in terms of the principal components. Unfortunately, widely available and utilized nonlinear regression techniques can have prohibitive computational requirements and/or accuracy that is highly dependent on user experience in ad hoc tuning of model architecture and hyperparameters. Here, in this work, a new nonlinear regression approach is proposed that is both computationally efficient and automated so does not require any user input. The approach is evaluated through a priori prediction of principal component source terms using data from a Direct Numerical Simulation of a turbulent nonpremixed n-heptane/air jet flame. In particular, the proposed framework consists of local regressions whose complexity is adapted according to the local nonlinearity of the data: local linear regression when accurate enough and local Artificial Neural Networks when nonlinear regression is required. The number of local clusters for local regression is determined automatically using the Davies-Bouldin index. In addition, Bayesian optimization is utilized for model training (i.e., to select the best architectures and hyperparameters of the nonlinear regressions in an unsupervised fashion), eliminating ad hoc hand-tuning and/or expensive grid searches. Overall, compared to a single, global neural network, the new local adaptive regression approach is shown to have comparable accuracy but 69% less training time due to the utilization of local linear regression and faster training of local neural networks.

42 ENGINEERING↗

First-principles DFT modeling of nitrobenzene adsorption on the Ag(111) surface at varying monolayer coverages

Here, the adsorption behavior of nitrobenzene on the Ag(111) surface as a function of coverage is investigated using density functional theory. Adsorption energies and optimized geometries are analyzed together with isolated intermolecular interaction calculations and electronic structure analysis, including Bader charge partitioning and projected density of states, to disentangle the roles of adsorbate–surface bonding and through-space adsorbate–adsorbate interactions. At low and intermediate coverages (θ = 1/9 and θ = 2/9), bidentate adsorption at top sites is favored due to strong adsorbate–surface interactions, with additional stabilization at θ = 2/9 arising from favorable intermolecular separations. At higher coverage (θ = 1/3), bidentate adsorption is destabilized by strong intermolecular repulsion, and monodentate adsorption becomes energetically preferred as rotational freedom allows more favorable intermolecular spacing. Charge density differences, Bader charge, and density of states analyses show that charge transfer from the Ag surface is localized primarily on the nitro group and increases with coverage and adsorption denticity, although this increase does not directly correlate with adsorption strength at high coverage due to competing intermolecular interactions. These results demonstrate that surface coverage can induce a transition in preferred adsorption denticity driven by intermolecular interactions, highlighting the importance of adsorbate packing in organic molecule adsorption at metal interfaces.

36 MATERIALS SCIENCE↗

Microkinetic Modeling: A Tool for Rational Catalyst Design

The design of heterogeneous catalysts relies on understanding the fundamental surface kinetics that controls catalyst performance, and microkinetic modeling is a tool that can help the researcher in streamlining the process of catalyst design. Microkinetic modeling is used to identify critical reaction intermediates and rate-determining elementary reactions, thereby providing vital information for designing an improved catalyst. In this review, we summarize general procedures for developing microkinetic models using reaction kinetics parameters obtained from experimental data, theoretical correlations, and quantum chemical calculations. We examine the methods required to ensure the thermodynamic consistency of the microkinetic model. We describe procedures required for parameter adjustments to account for the heterogeneity of the catalyst and the inherent errors in parameter estimation. We discuss the analysis of microkinetic models to determine the rate determining reactions using the degree of rate control and reversibility of each elementary reaction. We introduce incorporation of Brønsted–Evans–Polanyi relations and scaling relations in microkinetic models and the effects of these relations on catalytic performance and formation of volcano curves. We review the analysis of reaction schemes in terms of the maximum rate of elementary reactions, and we outline a procedure to identify kinetically significant transition states and adsorbed intermediates. Here, we explore the application of generalized rate expressions for the prediction of optimal binding energies of important surface intermediates and to estimate the extent of potential rate improvement. We also explore the application of microkinetic modeling in homogeneous catalysis, electro-catalysis, and transient reaction kinetics. We conclude by highlighting the challenges and opportunities in the application of microkinetic modeling for catalyst design.

42 ENGINEERING↗